RVRodrigo Antunes de Vasconcelos

Rodrigo Antunes de Vasconcelos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rodrigo Antunes de Vasconcelos has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Confiabilidade e validade de um dinamômetro isométrico modificado na avaliação do desempenho muscular em indivíduos com reconstrução do ligamento cruzado anterior

    by Rodrigo Antunes de Vasconcelos, Débora Bevilaqua-Grossi, Antonio Carlos Shimano, Cleber Jansen Paccola, Tânia Fátima Salvini, Christiane Lanatovits Prado, Wilson A. Mello Junior

    OBJETIVO: Analisar a confiabilidade e validade de um dinamômetro isométrico modificado (DIM) na avaliação dos déficits no desempenho muscular dos extensores e flexores do joelho em indivíduos normais e com reconstrução do LCA. MÉTODOS: Foram convidados 60 voluntários do sexo masculino a participar do estudo, divididos em três grupos de 20 indivíduos: grupo controle (GC), grupo com reconstrução do LCA com tendão patelar (GTP) e grupo com reconstrução do LCA com tendões flexores (GTF). Todos os indivíduos realizaram teste isométrico dos extensores e flexores do joelho no DIM; os déficits de força muscular coletados foram comparados posteriormente com os testes realizados no Biodex System 3 operando no modo isométrico e isocinético nas velocidades de 60º/s e 180º /s. Foram realizados cálculos de correlação intraclasse ICC para avaliar a confiabilidade do DIM, cálculos da especificidade, sensibilidade e coeficiente de concordância Kappa, respectivamente, para avaliar a validade do DIM em detectar déficits musculares e comparações intragrupos e intergrupos na realização dos quatro testes de força utilizando-se do método ANOVA. RESULTADOS: O DIM demonstrou excelente confiabilidade teste-reteste e validade na avaliação do desempenho muscular dos extensores e flexores do joelho. Na comparação intergrupos. o GTP demonstrou déficits significativamente maiores dos extensores comparados com os grupos GC e GTF. CONCLUSÃO: Dinamômetros isométricos conectados em equipamentos de mecanoterapia podem ser uma alternativa para coletar dados referentes a déficits no desempenho muscular dos extensores e flexores do joelho em indivíduos com reconstrução do LCA.OBJECTIVES: The aim of this study was to evaluate the reliability and validity of a modified isometric dynamometer (MID) in performance deficits of the knee extensor and flexor muscles in normal individuals and in those with ACL reconstructions. METHODS: Sixty male subjects were invited to participate of the study, being divided into three groups with 20 subjects each: control group (GC), group of individuals with ACL reconstruction with patellar tendon graft (GTP, and group of individuals with ACL reconstruction with hamstrings graft (GTF). All individuals performed isometric tests in the MID, muscular strength deficits collected were subsequently compared to the tests performed on the Biodex System 3 operating in the isometric and isokinetic mode at speeds of 60º/s and 180o/s. Intraclass ICC correlation calculations were done in order to assess MID reliability, specificity, sensitivity and Kappa's consistency coefficient calculations, respectively, for assessing the MID's validity in detecting muscular deficits and intra-and intergroup comparisons when performing the four strength tests using the ANOVA method. RESULTS: The modified isometric dynamometer (MID) showed excellent reliability and good validity in the assessment of the performance of the knee extensor and flexor muscles groups. In the comparison between groups, the GTP showed significantly greater deficits as compared to the GTF and GC groups. CONCLUSION: Isometric dynamometers connected to mechanotherapy equipments could be an alternative option to collect data concerning performance deficits of the extensor and flexor muscles groups of the knee in subjects with ACL reconstruction


  • Análise da correlação entre pico de torque, desempenho funcional e frouxidão ligamentar em indivíduos normais e com reconstrução do ligamento cruzado anterior

    by Rodrigo Antunes de Vasconcelos, Débora Bevilaqua-Grossi, Antonio Carlos Shimano, Cleber Antonio Jansen Paccola, Tânia Fátima Salvini, Christiane Lanatovits Prado, Wilson A. Mello Junior

    It is not recommendable to use only one measurement instrument for the functional evaluation of ACL-reconstructed patients, because significant correlation between peak torque, subject's functional score, knee laxity and hop tests were not observed in all groups.


  • Open Access

    FUNCTIONAL PERFORMANCE AND KNEE LAXITY IN NORMAL INDIVIDUALS AND IN INDIVIDUALS SUBMITTED TO ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION

    by Rodrigo Antunes de Vasconcelos, Débora Bevilaqua-Grossi, Antonio Carlos Shimano, Cleber Antonio Jansen Paccola, Tânia Fátima Salvini, Christiane Lanatovits Prado, Wilson A. Mello Junior

    The aim of this study was to analyze the correlation between deficits in the isokinetic peak torque of the knee extensors and flexors with hop tests, postoperative knee laxity and functional scores in normal and ACL- reconstructed subjects with patellar tendon and hamstring tendon autografts. Sixty male subjects were enrolled and subdivided into three groups: Twenty subjects without knee injuries (GC group) and two groups of 20 subjects submitted to ACL reconstruction with patellar tendon (GTP group) and hamstrings autograft (GTF group). The results showed significant correlation between knee extensors peak torque and performance in the hop tests for GTF and GC groups. There are no significantly correlations between post op knee laxity and Lysholm score compared with the hop tests and peak torque deficits. Concerning the differences between groups, the GTP group showed greater peak torque deficits in knee extensors, worst Lysholm scores and higher percentage of individuals with lower limb symmetry index (ISM) < 90% in both hop tests when compared to the other two groups. It is not recommendable to use only one measurement instrument for the functional evaluation of ACL-reconstructed patients, because significant correlation between peak torque, subject's functional score, knee laxity and hop tests were not observed in all groups.


  • Open Access

    RELIABILITY AND VALIDITY OF A MODIFIED ISOMETRIC DYNAMOMETER IN THE ASSESSMENT OF MUSCULAR PERFORMANCE IN INDIVIDUALS WITH ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION

    by Rodrigo Antunes de Vasconcelos, Débora Bevilaqua-Grossi, Antonio Carlos Shimano, Cleber Jansen Paccola, Tânia Fátima Salvini, Christiane Lanatovits Prado, Wilson A. Mello Junior

    Objectives: The aim of this study was to evaluate the reliability and validity of a modified isometric dynamometer (MID) in performance deficits of the knee extensor and flexor muscles in normal individuals and in those with ACL reconstructions. Methods: Sixty male subjects were invited to participate of the study, being divided into three groups with 20 subjects each: control group (GC), group of individuals with ACL reconstruction with patellar tendon graft (GTP, and group of individuals with ACL reconstruction with hamstrings graft (GTF). All individuals performed isometric tests in the MID, muscular strength deficits collected were subsequently compared to the tests performed on the Biodex System 3 operating in the isometric and isokinetic mode at speeds of 60°/s and 180o/s. Intraclass ICC correlation calculations were done in order to assess MID reliability, specificity, sensitivity and Kappa's consistency coefficient calculations, respectively, for assessing the MID's validity in detecting muscular deficits and intra- and intergroup comparisons when performing the four strength tests using the ANOVA method. Results: The modified isometric dynamometer (MID) showed excellent reliability and good validity in the assessment of the performance of the knee extensor and flexor muscles groups. In the comparison between groups, the GTP showed significantly greater deficits as compared to the GTF and GC groups. Conclusion: Isometric dynamometers connected to mechanotherapy equipments could be an alternative option to collect data concerning performance deficits of the extensor and flexor muscles groups of the knee in subjects with ACL reconstruction.


  • Open Access

    The effect of hip abduction on the EMG activity of vastus medialis obliquus, vastus lateralis longus and vastus lateralis obliquus in healthy subjects

    by Débora Bevilaqua-Grossi, Vanessa Monteiro-Pedro, Rodrigo Antunes de Vasconcelos, Juliano Coelho Arakaki, Fausto Bérzin

    Study design Controlled laboratory study. Objectives The purposes of this paper were to investigate (d) whether vastus medialis obliquus (VMO), vastus lateralis longus (VLL) and vastus lateralis obliquus (VLO) EMG activity can be influenced by hip abduction performed by healthy subjects. Background Some clinicians contraindicate hip abduction for patellofemoral patients (with) based on the premise that hip abduction could facilitate the VLL muscle activation leading to a VLL and VMO imbalance Methods and measures Twenty-one clinically healthy subjects were involved in the study, 10 women and 11 men (aged X = 23.3 ± 2.9). The EMG signals were collected using a computerized EMG VIKING II, with 8 channels and three pairs of surface electrodes. EMG activity was obtained from MVIC knee extension at 90° of flexion in a seated position and MVIC hip abduction at 0° and 30° with patients in side-lying position with the knee in full extension. The data were normalized in the MVIC knee extension at 50° of flexion in a seated position, and were submitted to ANOVA test with subsequent application of the Bonferroni multiple comparisons analysis test. The level of significance was defined as p ≤ 0.05. Results The VLO muscle demonstrated a similar pattern to the VMO muscle showing higher EMG activity in MVIC knee extension at 90° of flexion compared with MVIC hip abduction at 0° and 30° of abduction for male (p < 0.0007) and MVIC hip abduction at 0° of abduction for female subjects (p < 0.02196). There were no statistically significant differences in the VLL EMG activity among the three sets of exercises tested. Conclusion The results showed that no selective EMG activation was observed when comparison was made between the VMO, VLL and VLO muscles while performing MVIC hip abduction at 0° and 30° of abduction and MVIC knee extension at 90° of flexion in both male and female subjects. Our findings demonstrate that hip abduction do not facilitated VLL and VLO activity in relation to the VMO, however, this study included only healthy subjects performing maximum voluntary isometric contraction contractions, therefore much remains to be discovered by future research