GLGöran Lidén

Göran Lidén

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Göran Lidén has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Secondary Lip Flow in a Cyclone Separator

    by Dzmitry Misiulia, Göran Lidén, Sergiy Antonyuk

    Three secondary flows, namely the inward radial flow along the cyclone lid, the downward axial flow along the external surface of the vortex finder, and the radial inward flow below the vortex finder (lip flow) have been studied at a wide range of flow rate 0.22–7.54 LPM using the LES simulations. To evaluate these flows the corresponding methods were originally proposed. The highly significant effect of the Reynolds number on these secondary flows has been described by equations. The main finding is that the magnitude of all secondary flows decrease with increasing Reynolds number. The secondary inward radial flow along the cyclone lid is not constant and reaches its maximum value at the central radial position between the vortex finder external wall and the cyclone wall. The secondary downward axial flow along the external surface of the vortex finder significantly increases at the lowest part of the vortex finder and it is much larger than the secondary flow along the cyclone lid. The lip flow is much larger than the secondary inward radial flow along the cyclone lid, which was assumed in cyclone models to be equal to the lip flow, and the ratio of these two secondary flows is practically independent of the Reynolds number.


  • Inter-comparison of personal monitors for nanoparticles exposure at workplaces and in the environment

    by Ana Maria Todea, Stefanie Beckmann, Heinz Kaminski, Delphine Bard, Sébastien Bau, Simon Clavaguera, Dirk Dahmann, Hélène Dozol, Nico Dziurowitz, Karine Elihn, et al.


  • Open Access

    The European Commission Tries to Define Nanomaterials

    by GöRan LidéN

    In 2010, the European Commission held a short consultation on a proposed definition for nanomaterials, to be used in European Union legislation and programmes. This was in response to a European Parliament resolution, and the definition followed a proposal by one of the Commission’s scientific committees. The definition has three parts: on size distribution, size of internal structural elements, and surface area; a material caught by any of these parts meets the definition. There are a number of problems. The definition seems to be written with engineered nanomaterials in mind but as written applies to non-supplied materials, such as smokes. The structural element component seems to capture items such as sunscreen and tennis rackets, which include nanomaterials. Use of the definition will require some international standards, which have yet to be written and which will involve some difficult decisions. It is understandable why there are both size and surface area requirements, but they are not wholly consistent. The Commission plans a further consultation in 2012, but it might be better to delay this until after the standardisation work.


  • Open Access

    Respirable dust measurements in the brick manufacturing industry.

    by GÖRan LidÉN

    I have with great interest read the paper by de Vocht et al. (2009), which compared respirable dust samples collected in the brick-manufacturing industry using both a Higgins–Dewell type cyclone and a dual-fraction IOM sampler. The size separation in the dual-fraction IOM sampler is carried out by a foam inserted into the nozzle of the IOM sampler. I would like to comment on some of the regression analyses presented and, what I consider to be, a lack of analysis of their data.

  • Open Access

    A Headset-Mounted Mini Sampler for Measuring Exposure to Welding Aerosol in the Breathing Zone

    by Göran Lidén, Jouni Surakka

    There is a need for a small personal aerosol sampler for measuring occupational exposure to airborne particles in the breathing zone. Existing aerosol samplers are too large to be mounted inside modern welder's protective equipment without disturbing the worker. A headset-mounted mini sampler has been developed to fill this gap with focus on manganese exposure. This mini sampler is easy to use and can be mounted inside modern, slimline welder's face shield. The mini sampler is based on a commercially available 13-mm filter holder that has been modified to incorporate an inlet nozzle made of aluminium. The nominal flow rate of the mini sampler is 0.75 l min−1. The mini sampler is to be worn mounted on a headset, modified from professional microphone headsets. Several aspects related to using the mini sampler have been tested by personal and static sampling at five workplaces and in the laboratory. Four headset models were tested for their suitability as a sampler holder, of which three models were accepted by the welders. The sampling bias of the mini sampler versus the IOM sampler and the open-face 25-mm filter holder, respectively, depends on the size distribution of the sampled aerosol. At the lowest encountered mass concentration ratio of the open-face 25-mm filter holder to the IOM sampler (0.65), the sampling bias of the mini sampler versus the IOM sampler is approximately −26% and versus the open-face 25-mm filter holder is approximately +12%. For manganese, the negative root mean square (RMS) sampling bias of the mini sampler versus the IOM sampler is −0.046 and versus the open-face 25-mm filter holder is non-significant. Both these biases are statistically non-significant. The mini sampler can therefore be employed for determining welders’ occupational exposure to manganese. The pressure drop across the filter can become excessive due to the small filtration area. Compared to the Casella Apex pump, the SKC AirChek2000 pump was generally found to be able to keep its flow rate constant within ±5% at higher concentrations and for longer sampling times. Our results indicate that the inhalable fraction of the welding aerosol mass at the visited plants only consisted of 25–55% welding fume particles (agglomerates of coagulated particles generated by nucleation/condensation). The rest of the mass is made up of particles from spattering and grinding. More than 65% of manganese is generally found in the fume particles. The weighing precision of 13-mm filters is 2.2 μg. The RMS sample loss due to transport when loaded samples are shipped by mail in padded envelopes is 6 μg. Both figures are very low in comparison to the mass expected to be collected by personal sampling, generally exceeding 200 μg. The headset-mounted mini sampler is user-friendly, easy to adjust individually, does not disturb the welder during sampling and allows sampling inside personal protective equipment. The headset mounting arrangement improves personal sampling as it maintains the sampler close to the nose/mouth during the whole sampling period. This study shows that the developed headset-mounted mini sampler is suitable for assessing exposure to manganese in welding aerosol.


  • Open Access

    A Simple Theoretical Model for the Air Flow and Particle Penetration in a Modified Horizontal Elutriator with Plates of Unequal Lengths

    by Göran Lidén, Anders Jansson

    A simple theoretical model is presented for the distribution of air speeds in a modified horizontal elutriator consisting of groups of plates with different lengths. Equations are presented for calculating the particle penetration both in channels of shortended plate lengths, as downstream the end of a shortended plate.


  • Open Access

    Dustiness Testing of Materials Handled at Workplaces

    by Göran Lidén

    Occupational hygiene for airborne chemicals and other materials has mainly focused on the world as it is rather than how it might be changed. We have described as scientifically as possible workers' exposure and its determinants, and the effectiveness of control equipment and control strategies. This has led to a long string of good tools such as occupational exposure limits, sampling strategies and devices, check-lists, product information sheets, communication to employers and employed, and more cost-effective control equipment. All these tools have been continuously sharpened, and we have seen a very significant lowering of the exposure in the past 30–40 years.