Panagiota Karava
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Panagiota Karava has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Ilias Bilionis
Center for High Performance Buildings, Ray W. Herrick Laboratories, Purdue University, West Lafayette, IN, USA
4 shared publicationsJames Braun
Center for High Performance Buildings, Ray W. Herrick Laboratories, Purdue University, West Lafayette, IN, USA
3 shared publicationsSang Woo Ham
School of Civil Engineering, Purdue University, West Lafayette, IN, USA
3 shared publicationsAthanasios Tzempelikos
Lyles School of Civil Engineering, Purdue University, 550 Stadium Mall Dr., West Lafayette, IN 47907, USA
1 shared publication- Athanasios Tzempelikos
Purdue University
1 shared publication Jaewan Joe
Lyles School of Civil Engineering, Purdue University, 550 Stadium Mall Dr., West Lafayette, IN 47907, USA; Center for High Performance Buildings, Ray W. Herrick Laboratories, 140 S. Martin Jischke Dr., West Lafayette, IN 47907, USA
1 shared publication
Latest Publications
- 7 February 2022
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 15 (2) , 251-267
A scalable and practical method for disaggregating heating and cooling electrical usage using smart thermostat and smart metre data
We present a scalable and practical method for disaggregating electrical usage for heat pump heating and cooling (HC) that uses low-resolution data from existing smart energy metres and smart thermostats. The disaggregation model is based on a Bayesian approach to account for the skewed characteristics of HC and non-HC energy consumption and adopts sequential Bayesian update to enable reliable predictions without long-term data. The modelling approach is demonstrated using disaggregated electricity consumption and thermostat operation signal data in two multi-family residential communities located in two different cities in Indiana, U.S. The results show that the model successfully disaggregated HC electricity consumption for various housing units by using 15-minute interval data with less than 12% error for a weekly time interval. Finally, seasonal parameters of the model were updated when a new HC operation signal was observed resulting in good predictions for different seasons.
- 7 February 2022
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 15 (2) , 251-267
A scalable and practical method for disaggregating heating and cooling electrical usage using smart thermostat and smart metre data
We present a scalable and practical method for disaggregating electrical usage for heat pump heating and cooling (HC) that uses low-resolution data from existing smart energy metres and smart thermostats. The disaggregation model is based on a Bayesian approach to account for the skewed characteristics of HC and non-HC energy consumption and adopts sequential Bayesian update to enable reliable predictions without long-term data. The modelling approach is demonstrated using disaggregated electricity consumption and thermostat operation signal data in two multi-family residential communities located in two different cities in Indiana, U.S. The results show that the model successfully disaggregated HC electricity consumption for various housing units by using 15-minute interval data with less than 12% error for a weekly time interval. Finally, seasonal parameters of the model were updated when a new HC operation signal was observed resulting in good predictions for different seasons.
- 4 July 2021
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 14 (4) , 420-445
Real-time model for unit-level heating and cooling energy prediction in multi-family residential housing
In this paper, we introduce a real-time modelling approach to predict the heating and cooling energy consumption of each housing unit in multi-family residential buildings. We first present measured yearly heating and cooling energy use data from an actual building and introduce the eco-feedback design and associated modelling challenges. Subsequently, we present a real-time parameter learning-based modelling approach. The model has a state-space structure while state filtering and parameter estimation are simultaneously executed through particle filter with sequential Bayesian update. The housing unit-level model is coupled with a probabilistic model of the heating and cooling system by using thermostat, power metre, and mechanical system catalogue data through a Bayesian approach. The results show that the median power prediction of the model deviates less than 3.1% from measurements while the model learns seasonal parameters such as the cooling efficiency coefficient through sequential Bayesian update.
- 4 July 2021
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 14 (4) , 420-445
Real-time model for unit-level heating and cooling energy prediction in multi-family residential housing
In this paper, we introduce a real-time modelling approach to predict the heating and cooling energy consumption of each housing unit in multi-family residential buildings. We first present measured yearly heating and cooling energy use data from an actual building and introduce the eco-feedback design and associated modelling challenges. Subsequently, we present a real-time parameter learning-based modelling approach. The model has a state-space structure while state filtering and parameter estimation are simultaneously executed through particle filter with sequential Bayesian update. The housing unit-level model is coupled with a probabilistic model of the heating and cooling system by using thermostat, power metre, and mechanical system catalogue data through a Bayesian approach. The results show that the median power prediction of the model deviates less than 3.1% from measurements while the model learns seasonal parameters such as the cooling efficiency coefficient through sequential Bayesian update.
- 29 May 2021
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 14 (4) , 343-365
A data-driven model for building energy normalization to enable eco-feedback in multi-family residential buildings with smart and connected technology
In this paper, we present a new unit-level data-driven modelling approach to normalize heating and cooling (HC) energy usage in multi-family residential buildings based on easily accessible data from smart thermostats and WiFi-enabled power metres. Our physics-informed approach starts from a heat balance equation to derive a linear regression model and uses a Bayesian mixture model to identify groups of units that have similar regression coefficients. Our model captures the effect of behaviour on HC energy consumption by normalizing the effect of building characteristics and accounting for the inter-unit heat transfer and unobserved variables. Our probabilistic approach incorporates unit- and season-specific prior information and sequential Bayesian updating of model parameters when new data become available. Using yearly data collected in a multi-family building, our model identifies distinct normalized HC energy use groups in different seasons and provides more accurate rankings compared to the case without normalization.
- 29 May 2021
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 14 (4) , 343-365
A data-driven model for building energy normalization to enable eco-feedback in multi-family residential buildings with smart and connected technology
In this paper, we present a new unit-level data-driven modelling approach to normalize heating and cooling (HC) energy usage in multi-family residential buildings based on easily accessible data from smart thermostats and WiFi-enabled power metres. Our physics-informed approach starts from a heat balance equation to derive a linear regression model and uses a Bayesian mixture model to identify groups of units that have similar regression coefficients. Our model captures the effect of behaviour on HC energy consumption by normalizing the effect of building characteristics and accounting for the inter-unit heat transfer and unobserved variables. Our probabilistic approach incorporates unit- and season-specific prior information and sequential Bayesian updating of model parameters when new data become available. Using yearly data collected in a multi-family building, our model identifies distinct normalized HC energy use groups in different seasons and provides more accurate rankings compared to the case without normalization.
- Open Access
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1343 (1) , 012138
Integrating occupants’ voluntary thermal preference responses into personalized thermal control in office buildings
A Bayesian modeling approach which allows incorporating voluntary feedback data (comfort-related responses), collected via participatory interfaces, along with requested feedback data, into a thermal preference learning framework. This is achieved by explicitly considering occupant participation, a type of behavior, in the model. Experiments with human subjects were conducted to collect thermal preference datasets, with both participatory and requested setups, which were used to train personalized thermal preference models. The proposed approach allows using the participatory setup without distorting the thermal preference predictive probabilities. In addition, we propose a concept of smart occupant feedback request algorithm, that determines whether and when to request feedback based on the quantified value of the request. This work will lead to smarter, user-interactive comfort delivery systems that will be continuously updated through interactions with their occupants, and will provide customized indoor environments tailored to individual preferences.
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1343 (1) , 012138
Open AccessIntegrating occupants’ voluntary thermal preference responses into personalized thermal control in office buildings
A Bayesian modeling approach which allows incorporating voluntary feedback data (comfort-related responses), collected via participatory interfaces, along with requested feedback data, into a thermal preference learning framework. This is achieved by explicitly considering occupant participation, a type of behavior, in the model. Experiments with human subjects were conducted to collect thermal preference datasets, with both participatory and requested setups, which were used to train personalized thermal preference models. The proposed approach allows using the participatory setup without distorting the thermal preference predictive probabilities. In addition, we propose a concept of smart occupant feedback request algorithm, that determines whether and when to request feedback based on the quantified value of the request. This work will lead to smarter, user-interactive comfort delivery systems that will be continuously updated through interactions with their occupants, and will provide customized indoor environments tailored to individual preferences.
- 29 July 2016
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 10 (2) , 183-204
Agent-based system identification for control-oriented building models
The paper presents a general agent-based system identification framework as potential solution for data-driven models of building systems that can be developed and integrated with improved efficiency, flexibility and scalability, compared to centralized approaches. The proposed method introduces building sub-system agents, which are optimized independently, by solving locally a maximum likelihood estimation problem. Several models are considered for the sub-system agents and a systematic selection approach is established considering the root mean square error, the parameter sensitivity to output trajectory and the parameter correlation. The final model is integrated from selected models for each agent. Two different approaches are developed for the integration; the negotiated-shared parameter model, which is a distributed method, and the free-shared parameter model based on a decentralized method. The results from a case-study for a high performance building indicate that the model prediction accuracy of the new approach is fairly good for implementation in predictive control.
- 29 July 2016
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 10 (2) , 183-204
Agent-based system identification for control-oriented building models
The paper presents a general agent-based system identification framework as potential solution for data-driven models of building systems that can be developed and integrated with improved efficiency, flexibility and scalability, compared to centralized approaches. The proposed method introduces building sub-system agents, which are optimized independently, by solving locally a maximum likelihood estimation problem. Several models are considered for the sub-system agents and a systematic selection approach is established considering the root mean square error, the parameter sensitivity to output trajectory and the parameter correlation. The final model is integrated from selected models for each agent. Two different approaches are developed for the integration; the negotiated-shared parameter model, which is a distributed method, and the free-shared parameter model based on a decentralized method. The results from a case-study for a high performance building indicate that the model prediction accuracy of the new approach is fairly good for implementation in predictive control.
- Open Access
- 18 March 2015
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 21 (6) , 719-720
EDITORIAL: Predictive controls, modeling and technology assessment for high performance buildings
- 18 March 2015
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 21 (6) , 719-720
Open AccessEDITORIAL: Predictive controls, modeling and technology assessment for high performance buildings
- 5 April 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 276-285
Modeling and Predictive Control of Mixed-Mode Buildings with MatLab/GenOpt
The paper presents a transient multi-zone thermal model and anticipatory control strategies for a building with mixed-mode cooling. The model is based on the thermal network representation with advective heat transfer for modeling the heat exchange due to air flow between thermal zones. It is developed in Matlab, which is coupled with GenOpt as an optimizer. The paper presents results of simulations which model the performance of night cooling using "offline" predictive control strategies. Results show that the cooling load can be efficiently reduced by following the sequences based on anticipatory control techniques. The impact of building design parameters on the development of model-predictive control (MPC) strategies and the decisions made by the MPC controller are also discussed.
- 5 April 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 276-285
Modeling and Predictive Control of Mixed-Mode Buildings with MatLab/GenOpt
The paper presents a transient multi-zone thermal model and anticipatory control strategies for a building with mixed-mode cooling. The model is based on the thermal network representation with advective heat transfer for modeling the heat exchange due to air flow between thermal zones. It is developed in Matlab, which is coupled with GenOpt as an optimizer. The paper presents results of simulations which model the performance of night cooling using "offline" predictive control strategies. Results show that the cooling load can be efficiently reduced by following the sequences based on anticipatory control techniques. The impact of building design parameters on the development of model-predictive control (MPC) strategies and the decisions made by the MPC controller are also discussed.
- 1 April 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Engineering Mechanics
- Vol. 138 (4) , 358-370
Wind-Induced Internal Pressures in Buildings with Large Façade Openings
The paper presents the results of a study that investigated the effects of wall porosity, inlet-to-outlet-ratio, opening location, and blockage on internal pressure in buildings with large façade openings located on opposite or adjacent walls considering data from simultaneous measurements on multiple internal pressure taps. The study found that the internal airflow field has a significant effect on mean and peak values of internal pressure, which is not uniform for configurations with wall porosity higher than 10% and openings located on adjacent walls. Peak internal pressure coefficients were found to exceed (1) the recommended ASCE 7-10 value for all configurations tested with inlets located above the midheight of the building and particularly those with inlet-to-outlet-ratios equal to 1 and (2) the recommended design value for building category 3 for configurations with openings located above the midheight of the building, leeward wall outlets, and inlet-to-outlet-ratios greater than 2.
- 1 April 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Engineering Mechanics
- Vol. 138 (4) , 358-370
Wind-Induced Internal Pressures in Buildings with Large Façade Openings
The paper presents the results of a study that investigated the effects of wall porosity, inlet-to-outlet-ratio, opening location, and blockage on internal pressure in buildings with large façade openings located on opposite or adjacent walls considering data from simultaneous measurements on multiple internal pressure taps. The study found that the internal airflow field has a significant effect on mean and peak values of internal pressure, which is not uniform for configurations with wall porosity higher than 10% and openings located on adjacent walls. Peak internal pressure coefficients were found to exceed (1) the recommended ASCE 7-10 value for all configurations tested with inlets located above the midheight of the building and particularly those with inlet-to-outlet-ratios equal to 1 and (2) the recommended design value for building category 3 for configurations with openings located above the midheight of the building, leeward wall outlets, and inlet-to-outlet-ratios greater than 2.