David A. Palanzo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David A. Palanzo has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Shigang Wang
Penn State Hershey Pediatric Cardiovascular Research Center, Department of Pediatrics, Penn State Milton S. Hershey Medical Center, Penn State Hershey College of Medicine, Penn State Hershey Children's Hospital, Hershey, PA, USA
3 shared publications - Akif Ündar
Penn State College of Medicine
2 shared publications Allen R. Kunselman
Department of Pediatrics, Pediatric Cardiovascular Research Center, Penn State College of Medicine, Penn State Health Children's Hospital, Hershey, PA, USA
2 shared publicationsAly El‐Banayosy
Heart and Vascular Institute, Penn State Milton S. Hershey Medical Center Penn State Hershey College of Medicine, Penn State Hershey Children's Hospital Hershey PA USA
2 shared publications- John L. Myers
Department of Pediatrics, Pediatric Cardiovascular Research Center, Penn State College of Medicine, Penn State Health Children's Hospital, Hershey, PA, USA
2 shared publications - Joseph B. Clark
Department of Pediatrics, Penn State Hershey, Hershey, Pennsylvania 17033, USA
2 shared publications
Latest Publications
- Open Access
- 9 March 2017
- Published by Wiley in Artificial Organs
- Vol. 41 (3) , 218-223
Impact of Translational Research on Optimization of Neonatal Cardiopulmonary Bypass Circuits and Techniques-The Penn State Health Approach
- 9 March 2017
- Published by Wiley in Artificial Organs
- Vol. 41 (3) , 218-223
Open AccessImpact of Translational Research on Optimization of Neonatal Cardiopulmonary Bypass Circuits and Techniques-The Penn State Health Approach
- 18 January 2016
- Published by Wiley in Artificial Organs
- Vol. 40 (1) , 14-18
Impact of Pulsatile Flow on Vital Organ Recovery During Cardiopulmonary Bypass in Neonates and Infants
- 18 January 2016
- Published by Wiley in Artificial Organs
- Vol. 40 (1) , 14-18
Impact of Pulsatile Flow on Vital Organ Recovery During Cardiopulmonary Bypass in Neonates and Infants
- 17 November 2014
- Published by Wiley in Artificial Organs
- Vol. 38 (11) , 909-913
Impact of the 2013/2014 Influenza Season on Extracorporeal Membrane Oxygenation Programs in the United States
- 17 November 2014
- Published by Wiley in Artificial Organs
- Vol. 38 (11) , 909-913
Impact of the 2013/2014 Influenza Season on Extracorporeal Membrane Oxygenation Programs in the United States
- 6 January 2014
- Published by Wiley in Artificial Organs
- Vol. 38 (1) , 1-4
Choosing a Pump for Extracorporeal Membrane Oxygenation in the USA
- 6 January 2014
- Published by Wiley in Artificial Organs
- Vol. 38 (1) , 1-4
Choosing a Pump for Extracorporeal Membrane Oxygenation in the USA
- 27 August 2013
- Published by Wiley in Artificial Organs
- Vol. 37 (9) , E162-E166
Comparison of Hemolysis Between CentriMag and RotaFlow Rotary Blood Pumps During Extracorporeal Membrane Oxygenation
The purpose of this investigation was to compare the hemolysis levels for patients on extracorporeal membrane oxygenation (ECMO) incorporating two different rotary blood pumps (CentriMag [CMAG] and RotaFlow [RF]) in identical circuits otherwise. The difference between the two pumps is the cost. One is 20–30 times less expensive than the other. A retrospective analysis of all patients placed on ECMO from June 2008 through May 2012 was done to evaluate hemolysis. Daily plasma hemoglobin (pHb), lactate dehydrogenase (LDH), and lactate levels were collected on all patients. Values were compared between those patients who received a CMAG and those who received an RF. Patients had to be on ECMO for more than 2 days to be included in the study. Linear mixed effects models were fit to the data to assess differences over time for each continuous outcome. Forty patients were placed on ECMO incorporating CMAG, whereas 40 patients received an RF. There were no significant statistical differences between CMAG and RF groups when comparing days on support (8.7 ± 5.0; 8.4 ± 5.7), age (44.8 ± 18.3; 46.1 ± 16.0), body surface area (2.03 ± 0.36; 1.96 ± 0.31), gender (male: 58%, female: 42%; male: 55%, female: 45%), etiology, type of support (veno‐arterial [VA)]: 78%, veno‐venous [VV)]: 22%; VA: 82%, VV: 18%) and pre‐ECMO LDH levels (4004.0 ± 3583.2; 3603.7 ± 3354.1). There were also no significant differences between the CMAG and RF groups when comparing the mean values for daily pHb levels (5.7 ± 3.6; 5.7 ± 4.2), lactate levels (2.8 ± 1.9; 3.0 ± 2.1), and LDH levels (2656.3 ± 1606.8; 2688.6 ± 1726.1) or daily lactate, LDH, and pHb levels for the first 10 days of support. From our investigation, there is no difference between the CMAG and the RF blood pumps in regard to the creation of hemolysis during ECMO. The difference in cost of the devices does not correlate with the performance and outcomes.
- 27 August 2013
- Published by Wiley in Artificial Organs
- Vol. 37 (9) , E162-E166
Comparison of Hemolysis Between CentriMag and RotaFlow Rotary Blood Pumps During Extracorporeal Membrane Oxygenation
The purpose of this investigation was to compare the hemolysis levels for patients on extracorporeal membrane oxygenation (ECMO) incorporating two different rotary blood pumps (CentriMag [CMAG] and RotaFlow [RF]) in identical circuits otherwise. The difference between the two pumps is the cost. One is 20–30 times less expensive than the other. A retrospective analysis of all patients placed on ECMO from June 2008 through May 2012 was done to evaluate hemolysis. Daily plasma hemoglobin (pHb), lactate dehydrogenase (LDH), and lactate levels were collected on all patients. Values were compared between those patients who received a CMAG and those who received an RF. Patients had to be on ECMO for more than 2 days to be included in the study. Linear mixed effects models were fit to the data to assess differences over time for each continuous outcome. Forty patients were placed on ECMO incorporating CMAG, whereas 40 patients received an RF. There were no significant statistical differences between CMAG and RF groups when comparing days on support (8.7 ± 5.0; 8.4 ± 5.7), age (44.8 ± 18.3; 46.1 ± 16.0), body surface area (2.03 ± 0.36; 1.96 ± 0.31), gender (male: 58%, female: 42%; male: 55%, female: 45%), etiology, type of support (veno‐arterial [VA)]: 78%, veno‐venous [VV)]: 22%; VA: 82%, VV: 18%) and pre‐ECMO LDH levels (4004.0 ± 3583.2; 3603.7 ± 3354.1). There were also no significant differences between the CMAG and RF groups when comparing the mean values for daily pHb levels (5.7 ± 3.6; 5.7 ± 4.2), lactate levels (2.8 ± 1.9; 3.0 ± 2.1), and LDH levels (2656.3 ± 1606.8; 2688.6 ± 1726.1) or daily lactate, LDH, and pHb levels for the first 10 days of support. From our investigation, there is no difference between the CMAG and the RF blood pumps in regard to the creation of hemolysis during ECMO. The difference in cost of the devices does not correlate with the performance and outcomes.
- 1 March 2009
- Published by SAGE Publications in Perfusion
- Vol. 24 (2) , 75-79
Successful treatment of peripartum cardiomyopathy with extracorporeal membrane oxygenation
A 24-year-old female developed heart failure within four months of delivering her first child. Echocardiogram revealed a moderately dilated left ventricle with severely reduced systolic function. She continued to decompensate, requiring intubation and inotropic support. When the use of an intra-aortic balloon pump failed to stabilize the patient, the decision was made to place her on ECMO. The circuit consisted of a Quadrox D membrane oxygenator and a CentriMag® centrifugal pump. After 11 days of support, the patient met the weaning criteria and was successfully removed from ECMO. She was discharged one month after her admission. The new technology available allows for ECMO to be considered as an earlier option for the treatment and management of these patients as a bridge to recovery.
- 1 March 2009
- Published by SAGE Publications in Perfusion
- Vol. 24 (2) , 75-79
Successful treatment of peripartum cardiomyopathy with extracorporeal membrane oxygenation
A 24-year-old female developed heart failure within four months of delivering her first child. Echocardiogram revealed a moderately dilated left ventricle with severely reduced systolic function. She continued to decompensate, requiring intubation and inotropic support. When the use of an intra-aortic balloon pump failed to stabilize the patient, the decision was made to place her on ECMO. The circuit consisted of a Quadrox D membrane oxygenator and a CentriMag® centrifugal pump. After 11 days of support, the patient met the weaning criteria and was successfully removed from ECMO. She was discharged one month after her admission. The new technology available allows for ECMO to be considered as an earlier option for the treatment and management of these patients as a bridge to recovery.
- 1 March 2009
- Published by SAGE Publications in Perfusion
- Vol. 24 (2) , 81-82
Commentary on: Successful treatment of peripartum cardiomyopathy with extracorporeal membrane oxygenation
- 1 March 2009
- Published by SAGE Publications in Perfusion
- Vol. 24 (2) , 81-82
Commentary on: Successful treatment of peripartum cardiomyopathy with extracorporeal membrane oxygenation