BTBenjamin Ka Thomson

Benjamin Ka Thomson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Benjamin Ka Thomson has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Clinical Effects of Personalized Dialysate Sodium in Conventional, Quotidian, and Nocturnal Home Hemodialysis Patients: A Randomized Crossover Trial

    by Benjamin Ka Thomson, Lihua Li, Robert M Lindsay

    Background: In thrice weekly conventional haemodialysis patients, higher dialysate sodium concentrations may associate with adverse clinical outcomes. Whether increased frequency and duration of haemodialysis in quotidian and nocturnal patients alters these clinical outcomes is unknown. Methods: A randomized crossover study was performed in conventional, quotidian and nocturnal haemodialysis patients. Dialysate sodium (Dial-Na+) was personalized 3 mmol/L above (DIALHighSOD) or below (DIALLowSOD) the pre-dialysis plasma sodium set point (SP), with 100 days for each crossover study period. Results: Interdialytic weight gain (IDWG)(2.15 vs. 1.90 L, p=0.002), IDWG as % of target weight (IDWG%)(2.78 vs. 2.39%, p=0.002), pre-dialysis systolic (143.3 vs. 138.3 mm Hg, p=0.001), diastolic (78.6 vs. 75.6 mm Hg, p=0.008) and mean arterial pressure (100.2 vs. 96.5 mm Hg, p=0.003), post-dialysis systolic (135.4 vs. 130.0 mm Hg, p=0.04), diastolic (75.8 vs. 72.4 mm Hg, p=0.006) and mean arterial pressure (95.7 vs. 91.6 mm Hg, p=0.009) were higher in DIALHighSOD than DIALLowSOD. Haemodialysis frequency was associated with decreased (R=-0.295, slope=-0.002, p=0.034) IDWG%, while the opposite was seen with haemodialysis duration (R=0.507, slope=0.002, p<0.001). Haemodialysis duration increased intradialytic change in diastolic blood pressure (R=0.280, slope=1.127, p=0.044), while haemodialysis frequency increased post-dialysis diastolic blood pressure (R=0.366, slope=3.464, p=0.008). Conclusions: These results confirm that dialysate sodium concentration alters clinical outcomes in quotidian and nocturnal haemodialysis patients, and that dialysis frequency and duration correlate in opposing fashions in IDWG. Further studies are required to determine the effect of dialysate sodium on cardiovascular outcomes. This trial is registered at UMIN000026102.


  • Open Access

    Maternal, pregnancy and fetal outcomes in de novo anti-glomerular basement membrane antibody disease in pregnancy: a systematic review

    by Benjamin Thomson, Geena Joseph, William F. Clark, Michelle Hladunewich, Amit Patel, Peter Blake, Genevieve Eastabrook, Doreen Matsui, Ajay Sharma, Andrew House

    Outside of pregnancy, anti-glomerular basement membrane (GBM) antibody disease is associated with significant morbidity and mortality. However, there is limited knowledge regarding de novo anti-GBM disease in pregnancy. A systematic review was performed to identify maternal, pregnancy and fetal outcomes in de novo anti-GBM disease in pregnancy. Studies were selected from PubMed, EMBASE, Cochrane Library databases and conference proceedings, without language restriction. Data from eight patients were derived from seven case reports and one unpublished case. Most (6/8) patients presented after the first trimester. During pregnancy, acute kidney injury (5/8), anemia (5/8), hematuria (8/8) and proteinuria (8/8) were common. When hemodialysis was required antepartum (5/8), renal function recovery to independence of renal replacement was unlikely (2/5). While pulmonary involvement was common (5/8), no permanent damage was reported (0/8). The majority of cases ended in live births (6/8) although prematurity (6/6), intrauterine growth restriction (2/6), small for gestational age (4/6) and complications of prematurity (1/6) were common. When anti-GBM levels were tested in the living newborn, they were detectable (2/5), but no newborn renal or lung disease was reported (0/6). Complications in pregnancy included gestational diabetes (3/8), hyperemesis gravidarum (2/8) and preeclampsia (2/8). Live births can be achieved in de novo anti-GBM disease in pregnancy, but are commonly associated with adverse maternal, pregnancy and fetal outcomes. Only with awareness of common presentations, and management strategies can outcomes be optimized.


  • Plasma Sodium Setpoint

    by Benjamin K.A. Thomson, Shih-Han S. Huang, Christopher T. Chan, Andrew A. House, Robert M. Lindsay

    Stability of predialysis sodium "setpoint" has not been validated in quotidian dialysis patients. We performed a retrospective review of our home hemodialysis program, to determine the effect of transitioning from conventional thrice weekly to home hemodialysis modalities differing in dialysis duration and frequency (n = 87). Mean sodium setpoint remained constant in patients who went home on intermittent hemodialysis, but decreased by 100 days in frequent nocturnal home hemodialysis (FNHD) (140.5-137.1 mM, p = 0.001) and short hours daily hemodialysis (SHD) (140.2-138.7 mM, p = 0.019) patients with a pretransition setpoint greater than dialysate sodium of 140 mM. Slope of predialysis sodium concentration within the first 100 days post-transition (M100) was less than zero in SHD (95% confidence interval [CI], -0.0081 to -0.0351 mM/day) and FNHD (95% CI, -0.0209 to -0.0695 mM/day) patients who started with a pretransition setpoint greater than dialysate sodium concentration of 140 mM. Change in sodium setpoint (SP) was predicted by dialysis frequency and the difference between dialysate sodium concentration and the pretransition predialysis sodium concentration (R = 35.4%, adjusted R = 33.8%, p < 0.001). Thus, personalizing dialysate sodium concentrations may be associated with a decrease in SP, which is independently associated with increased mortality. Further research is required to determine whether intentional increases in the SP could improve cardiovascular and all-cause mortality.


  • Open Access

    Warfarin use in hemodialysis patients with atrial fibrillation: decisions based on uncertainty

    by Salina Juma, Benjamin Ka Thomson, Charmaine E Lok, Catherine M Clase, Peter G Blake, Louise Moist

    Background: Warfarin prescribing patterns for hemodialysis patients with atrial fibrillation vary widely amongst nephrologists. This may be due to a paucity of guiding evidence, but also due to concerns of increased risks of warfarin use in this population. The literature lacks clarity on the balance of warfarin therapy between prevention of thrombotic strokes and the increased risks of bleeding in hemodialysis patients with atrial fibrillation. Methods: We performed a survey of Canadian Nephrologists, assessing warfarin prescribing practice, and measured the certainty in making these choices. Results: Respondents were consistently uncertain about warfarin use for atrial fibrillation. This uncertainty increased with a history of falls or starting hemodialysis, even when a high CHADS2 or CHA2DS2VASc score was present. The majority of respondents agreed that clinical equipoise existed about the use of oral anticoagulation in hemodialysis patients with atrial fibrillation (72.2%) and that the results of a randomized controlled trial would be relevant to their practice (98.2%). Conclusions: A randomized controlled trial of warfarin use in hemodialysis patients with atrial fibrillation would clarify the risks and benefits of warfarin use in this population.


  • Open Access

    Evaluation of an electronic warfarin nomogram for anticoagulation of hemodialysis patients

    by Benjamin Ka Thomson, Jennifer M MacRae, Lianne Barnieh, Jianguo Zhang, Elizabeth MacKay, Megan A Manning, Brenda R Hemmelgarn

    Background: Warfarin nomograms to guide dosing have been shown to improve control of the international normalized ratio (INR) in the general outpatient setting. However, the effectiveness of these nomograms in hemodialysis patients is unknown. We evaluated the effectiveness of anticoagulation using an electronic warfarin nomogram administered by nurses in outpatient hemodialysis patients, compared to physician directed therapy. Methods: Hemodialysis patients at any of the six outpatient clinics in Calgary, Alberta, treated with warfarin anticoagulation were included. Two five-month time periods were compared: prior to and post implementation of the nomogram. The primary endpoint was adequacy of anticoagulation (proportion of INR measurements within range ± 0.5 units). Results: Overall, 67 patients were included in the pre- and 55 in the post-period (with 40 patients in both periods). Using generalized linear mixed models, the adequacy of INR control was similar in both periods for all range INR levels: in detail, range INR 1.5 to 2.5 (pre 93.6% (95% CI: 88.6% - 96.5%); post 95.6% (95% CI: 89.4% - 98.3%); p = 0.95); INR 2.0 to 3.0 (pre 82.2% (95% CI: 77.9% - 85.8%); post 77.4% (95% CI: 72.0% - 82.0%); p = 0.20); and, INR 2.5 to 3.5 (pre 84.3% (95% CI: 59.4% - 95.1%); post 66.8% (95% CI: 39.9% - 86.0%); p = 0.29). The mean number of INR measurements per patient decreased significantly between the pre- (30.5, 95% CI: 27.0 - 34.0) and post- (22.3, 95% CI: 18.4 - 26.1) (p = 0.003) period. There were 3 bleeding events in each of the periods. Conclusions: An electronic warfarin anticoagulation nomogram administered by nurses achieved INR control similar to that of physician directed therapy among hemodialysis patients in an outpatient setting, with a significant reduction in frequency of testing. Future controlled trials are required to confirm the efficacy of this nomogram.