Celal Ferdi Gökçay
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Celal Ferdi Gökçay has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Basak K. Taseli
The Authority for the Protection of Special Areas, Alparslan Türkeş Cad., 31.Sok., No: 10, Beştepe, Ankara, Turkey
2 shared publications Filiz B. Dilek
Middle East Technical University, Environmental Engineering Department, 06531, Ankara, Turkey
2 shared publications- Melis Muz
UFZ - Helmholtz Centre for Environmental Research, Department of Exposure Science, Permoserstraße 15, 04318, Leipzig, Germany
2 shared publications A. Gürol
Middle East Technical University
1 shared publicationFiliz B Dilek
Department of Environmental Engineering, Middle East Technical University, 06531 Ankara, Turkey
1 shared publicationM. Selcen Ak
Department of Environmental Engineering , Middle East Technical University , 06531 , Ankara , Turkey
1 shared publication
Latest Publications
- Open Access
- 2 January 2014
- Published by Taylor & Francis in Ozone: Science & Engineering
- Vol. 36 (1) , 57-64
Intermittent Ozone Application in Aerobic Sludge Digestion
Excess biological sludge, WAS, produced during activated sludge process is a growing problem for the utilities owing to the stringent regulations now imposed worldwide. One method of handling the excess sludge is to digest it, to reduce its amount and to stabilize it. Aerobic digestion is particularly suitable for nutrient treating plants as sludge should not be exposed to anaerobiosis since this will lead to release of accumulated phosphorus. A novel and patented ozone-assisted aerobic sludge digestion process (PCT/TR2010/000213) is shown to appreciably shorten the 15–30-day aerobic digestion period and the extent of solids destroyed. WAS samples were ozonated for different periods in Erlenmeyer flasks, once a day, on each of four consecutive days. Flasks were continuously aerated between ozone applications. The MLVSS, MLSS, COD and OUR parameters were measured routinely during the course of four days of digestion in order to optimize the process. As a result 22.6%, 40%, 75% and 84% MLVSS reductions were obtained at total ozone applications of 0.42, 0.64, 0.85 and 1.27 mg O3 g−1 MLSS, at the end of the fourth day. Hence, it became possible to save on contact time as well as achieving a bio-solids digestion far exceeding the standard aerobic process, which is 40–50% in 15–30 days, at the expense of a minimum of ozone dose. The developed process is deemed superior over side-stream ozonation where ozone is applied to the return activated sludge, RAS, line; in that it does not cause any reduction in active biomass amount maintained in the aeration tank. Conversely, reduction in active biomass concentration results in reduced treatment efficiency.
- 2 January 2014
- Published by Taylor & Francis in Ozone: Science & Engineering
- Vol. 36 (1) , 57-64
Open AccessIntermittent Ozone Application in Aerobic Sludge Digestion
Excess biological sludge, WAS, produced during activated sludge process is a growing problem for the utilities owing to the stringent regulations now imposed worldwide. One method of handling the excess sludge is to digest it, to reduce its amount and to stabilize it. Aerobic digestion is particularly suitable for nutrient treating plants as sludge should not be exposed to anaerobiosis since this will lead to release of accumulated phosphorus. A novel and patented ozone-assisted aerobic sludge digestion process (PCT/TR2010/000213) is shown to appreciably shorten the 15–30-day aerobic digestion period and the extent of solids destroyed. WAS samples were ozonated for different periods in Erlenmeyer flasks, once a day, on each of four consecutive days. Flasks were continuously aerated between ozone applications. The MLVSS, MLSS, COD and OUR parameters were measured routinely during the course of four days of digestion in order to optimize the process. As a result 22.6%, 40%, 75% and 84% MLVSS reductions were obtained at total ozone applications of 0.42, 0.64, 0.85 and 1.27 mg O3 g−1 MLSS, at the end of the fourth day. Hence, it became possible to save on contact time as well as achieving a bio-solids digestion far exceeding the standard aerobic process, which is 40–50% in 15–30 days, at the expense of a minimum of ozone dose. The developed process is deemed superior over side-stream ozonation where ozone is applied to the return activated sludge, RAS, line; in that it does not cause any reduction in active biomass amount maintained in the aeration tank. Conversely, reduction in active biomass concentration results in reduced treatment efficiency.
- 1 August 2013
- Published by Elsevier in Chemical Engineering Journal
- Vol. 230, 499-505
Enhancement of bio-gas production and xenobiotics degradation during anaerobic sludge digestion by ozone treated feed sludge
- 1 August 2013
- Published by Elsevier in Chemical Engineering Journal
- Vol. 230, 499-505
Enhancement of bio-gas production and xenobiotics degradation during anaerobic sludge digestion by ozone treated feed sludge
- 10 May 2013
- Published by Taylor & Francis in Environmental Technology
- Vol. 35 (5) , 645-652
Investigation of sludge viscosity and its effects on the performance of a vacuum rotation membrane bioreactor
Sludge characteristics of a full-scale vacuum rotation membrane (VRM) bioreactor having plate-type membranes with 0.038 μm nominal pore size and 540 m2 surface area were investigated. The VRM plant is composed of an aeration tank and a filtration chamber. The sludge floc size distribution, as determined microscopically, was mainly between 0 and 100 μm in the filter chamber with very little difference in size distribution between summer (20–25°C) and winter (10–15°C) seasons. Small floc size encountered in the filtration chamber was evident due to excessive shear administered by the rotation action and vigorous agitation by the scouring air. The mixed liquor suspended solids (MLSS) was variable between 5.23 and 14.10 g/L in the VRM tank and sludge behaved plastic. Viscosity ranged between 2.39 and 30 cP in the VRM tank in relation with MLSS concentration and temperature. Above 20 cP inter-plate spaces rapidly clogged leading to major clean-up.
- 10 May 2013
- Published by Taylor & Francis in Environmental Technology
- Vol. 35 (5) , 645-652
Investigation of sludge viscosity and its effects on the performance of a vacuum rotation membrane bioreactor
Sludge characteristics of a full-scale vacuum rotation membrane (VRM) bioreactor having plate-type membranes with 0.038 μm nominal pore size and 540 m2 surface area were investigated. The VRM plant is composed of an aeration tank and a filtration chamber. The sludge floc size distribution, as determined microscopically, was mainly between 0 and 100 μm in the filter chamber with very little difference in size distribution between summer (20–25°C) and winter (10–15°C) seasons. Small floc size encountered in the filtration chamber was evident due to excessive shear administered by the rotation action and vigorous agitation by the scouring air. The mixed liquor suspended solids (MLSS) was variable between 5.23 and 14.10 g/L in the VRM tank and sludge behaved plastic. Viscosity ranged between 2.39 and 30 cP in the VRM tank in relation with MLSS concentration and temperature. Above 20 cP inter-plate spaces rapidly clogged leading to major clean-up.
- 3 June 2008
- Published by Oxford University Press (OUP) in Journal of Industrial Microbiology and Biotechnology
- Vol. 35 (9) , 1033-1039
Influence of nickel (II) and chromium (VI) on the laboratory scale rotating biological contactor
High concentration of heavy metals is toxic for most microorganisms and cause strict damage in wastewater treatment operations and often a physico-chemical pretreatment prior to biological treatment is considered necessary. However, in this study it has been shown that biological systems can adapt to Ni (II) and Cr (VI) when their concentration is below 10 and 20 mg/L, respectively. The aim of this study was to evaluate the effect of Ni (II) and Cr (VI) on the lab-scale rotating biological contactor process. It was found that, addition of Ni (II) up to 10 mg/L did not reduce the chemical oxygen demand removal efficiency and on the contrary concentrations below 10 mg/L improved the performance. The influent Ni (II) concentration of 1 mg/L was the concentration where the treatment efficiency produced a maximum COD removal of 86.5%. Moreover, Ni (II) concentration above 10 mg/L was relatively toxic to the system and produced lower treatment efficiencies than the baseline study without Ni (II). Turbidity and suspended solids removals were not stimulated to a great extent with nickel. Addition of Ni (II) did not seem to affect the pH of the system during treatment. The dissolved oxygen concentration did not drop below 4 mg/L at all concentrations of Ni (II) indicating aerobic conditions prevailed in the system. Experiments conducted with Cr (VI) revealed that addition of Cr (VI) up to 20 mg/L did not reduce the COD removal efficiency and on the contrary concentrations below 20 mg/L improved the performance. The influent Cr (VI) concentration of 1 mg/L was the concentration where the treatment efficiency produced a maximum COD removal of 88%. Turbidity and SS removals were more efficient at 5 mg/L Cr (VI) concentration, rather than 1 mg/L, which lead to the conclusion that 5 mg/L Cr (VI) concentration is the optimum concentration, in terms of COD, turbidity and SS removals. Similar with Ni (II) experiments, addition of Cr (VI) did not significantly affect the pH value of the effluent. The DO concentration remained above 5 mg/L.
- 3 June 2008
- Published by Oxford University Press (OUP) in Journal of Industrial Microbiology and Biotechnology
- Vol. 35 (9) , 1033-1039
Influence of nickel (II) and chromium (VI) on the laboratory scale rotating biological contactor
High concentration of heavy metals is toxic for most microorganisms and cause strict damage in wastewater treatment operations and often a physico-chemical pretreatment prior to biological treatment is considered necessary. However, in this study it has been shown that biological systems can adapt to Ni (II) and Cr (VI) when their concentration is below 10 and 20 mg/L, respectively. The aim of this study was to evaluate the effect of Ni (II) and Cr (VI) on the lab-scale rotating biological contactor process. It was found that, addition of Ni (II) up to 10 mg/L did not reduce the chemical oxygen demand removal efficiency and on the contrary concentrations below 10 mg/L improved the performance. The influent Ni (II) concentration of 1 mg/L was the concentration where the treatment efficiency produced a maximum COD removal of 86.5%. Moreover, Ni (II) concentration above 10 mg/L was relatively toxic to the system and produced lower treatment efficiencies than the baseline study without Ni (II). Turbidity and suspended solids removals were not stimulated to a great extent with nickel. Addition of Ni (II) did not seem to affect the pH of the system during treatment. The dissolved oxygen concentration did not drop below 4 mg/L at all concentrations of Ni (II) indicating aerobic conditions prevailed in the system. Experiments conducted with Cr (VI) revealed that addition of Cr (VI) up to 20 mg/L did not reduce the COD removal efficiency and on the contrary concentrations below 20 mg/L improved the performance. The influent Cr (VI) concentration of 1 mg/L was the concentration where the treatment efficiency produced a maximum COD removal of 88%. Turbidity and SS removals were more efficient at 5 mg/L Cr (VI) concentration, rather than 1 mg/L, which lead to the conclusion that 5 mg/L Cr (VI) concentration is the optimum concentration, in terms of COD, turbidity and SS removals. Similar with Ni (II) experiments, addition of Cr (VI) did not significantly affect the pH value of the effluent. The DO concentration remained above 5 mg/L.
- 1 February 2005
- Published by Elsevier in Process Biochemistry
- Vol. 40 (2) , 917-923
Degradation of chlorinated compounds by Penicillium camemberti in batch and up-flow column reactors
- 1 February 2005
- Published by Elsevier in Process Biochemistry
- Vol. 40 (2) , 917-923
Degradation of chlorinated compounds by Penicillium camemberti in batch and up-flow column reactors
- 1 September 1996
- Published by IWA Publishing in Water Science & Technology
- Vol. 34 (5-6) , 183-191
Microbiology of activated sludge treating wastewater containing Ni(II) and Cr(VI)
The species of microorganisms dominating a laboratory-scale once-through activated sludge unit treating simulated wastewater with different influent strengths (650 and 1300 mgl−1 COD) and containing 5 to 10 mgl−1 Ni(II) and 1 to 50 mgl−1 Cr(VI) were identified by standard biochemical tests. Within this framework, combinations of metals and influent COD concentrations were tried. Organisms, namely Proteus rettgeri, Acinetobacter sp., Flavobacterium lutescens, Bacillus cereus var. albolactis, Klebsiella sp., Arthrobacter simplex, and Pseudomonas mendocina, were identified at different stages of the experiments.
- 1 September 1996
- Published by IWA Publishing in Water Science & Technology
- Vol. 34 (5-6) , 183-191
Microbiology of activated sludge treating wastewater containing Ni(II) and Cr(VI)
The species of microorganisms dominating a laboratory-scale once-through activated sludge unit treating simulated wastewater with different influent strengths (650 and 1300 mgl−1 COD) and containing 5 to 10 mgl−1 Ni(II) and 1 to 50 mgl−1 Cr(VI) were identified by standard biochemical tests. Within this framework, combinations of metals and influent COD concentrations were tried. Organisms, namely Proteus rettgeri, Acinetobacter sp., Flavobacterium lutescens, Bacillus cereus var. albolactis, Klebsiella sp., Arthrobacter simplex, and Pseudomonas mendocina, were identified at different stages of the experiments.
- 1 November 1991
- Published by Taylor & Francis in Environmental Technology
- Vol. 12 (11) , 1007-1016
Effects of CU (II) on a chemostat containing activated sludge
The purpose of this study was to evaluate the toxic effects of Cu(II) on a chemostat containing activated sludge. Different concentrations of Cu(II) (0.5, 1.0, 5.0, and 10.0mgL‐1) were maintained in a laboratory‐scale completely mixed activated sludge unit, without recycle, treating simulated wastewater. The feed solution contained 650 mgL‐1 protein (corresponding to 1300 mgL‐1 COD) as a source of carbon. Experimental results indicated that the treatment efficiency was not adversely effected by the presence of Cu(II) up to the concentration of 10.0 mgL‐1. Moreover, some stimulatory effects of Cu(II) on the biokinetic parameters were observed.
- 1 November 1991
- Published by Taylor & Francis in Environmental Technology
- Vol. 12 (11) , 1007-1016
Effects of CU (II) on a chemostat containing activated sludge
The purpose of this study was to evaluate the toxic effects of Cu(II) on a chemostat containing activated sludge. Different concentrations of Cu(II) (0.5, 1.0, 5.0, and 10.0mgL‐1) were maintained in a laboratory‐scale completely mixed activated sludge unit, without recycle, treating simulated wastewater. The feed solution contained 650 mgL‐1 protein (corresponding to 1300 mgL‐1 COD) as a source of carbon. Experimental results indicated that the treatment efficiency was not adversely effected by the presence of Cu(II) up to the concentration of 10.0 mgL‐1. Moreover, some stimulatory effects of Cu(II) on the biokinetic parameters were observed.