SGStefanie Girst

Stefanie Girst

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Stefanie Girst has a total of 33 co-authors. Here are the top co-authors by number of shared publications:

  • Christian Siebenwirth

    Institut für Angewandte Physik und Messtechnik (LRT2), Universität der Bundeswehr München, Neubiberg, Germany; Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, Munich, Germany

    3 shared publications
  • Christoph Greubel

    Institut für Angewandte Physik und Messtechnik (LRT2), Universität der Bundeswehr München, Neubiberg, Germany

    3 shared publications
  • Günther Dollinger

    Institut für Angewandte Physik und Messtechnik (LRT2), Universität der Bundeswehr München, Neubiberg, Germany

    3 shared publications
  • Günther Dollinger

    Institute for Applied Physics and Measurement Technology, University of the Bundeswehr Munich, 85579 Munich, Germany

    3 shared publications
  • Olga Zlobinskaya

    Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, Munich, Germany

    3 shared publications
  • Thomas Ernst Schmid

    Institute of Radiation Medicine (IRM), Department of Radiation Sciences (DRS), Helmholtz Zentrum München, 85764 Neuherberg, Germany

    3 shared publications

Latest Publications

  • Open Access

    Improving Fabrication and Performance of Additively Manufactured RF Cavities by Employing Co-Printed Support Structures and Their Subsequent Removal

    by Michael Mayerhofer, Stefan Brenner, Michael Doppler, Luis Catarino, Stefanie Girst, Vesna Nedeljkovic-Groha, Günther Dollinger

    The enormous potential of additive manufacturing (AM), particularly laser powder bed fusion (L-PBF), to produce radiofrequency cavities (cavities) has already been demonstrated. However, the required geometrical accuracy for GHz TM010 cavities is currently only achieved by (a) avoiding downskin angles <40∘, which in turn leads to a cavity geometry with reduced performance, or (b) co-printed support structures, which are difficult to remove for small GHz cavities. We have developed an L-PBF-based manufacturing routine to overcome this limitation. To enable arbitrary geometries, co-printed support structures are used that are designed in such a way that they can be removed after printing by electrochemical post-processing, which simultaneously reduces the surface roughness and thus maximizes the quality factor Q0. The manufacturing approach is evaluated on two TM010 single cavities printed entirely from high-purity copper. Both cavities achieve the desired resonance frequency and a Q0 of approximately 8300.


  • Open Access

    Longitudinally Heterogeneous Tumor Dose Optimizes Proton Broadbeam, Interlaced Minibeam, and FLASH Therapy

    by Matthias Sammer, Aikaterini Rousseti, Stefanie Girst, Judith Reindl, Günther Dollinger

    The prerequisite of any radiation therapy modality (X-ray, electron, proton, and heavy ion) is meant to meet at least a minimum prescribed dose at any location in the tumor for the best tumor control. In addition, there is also an upper dose limit within the tumor according to the International Commission on Radiation Units (ICRU) recommendations in order to spare healthy tissue as well as possible. However, healthy tissue may profit from the lower side effects when waving this upper dose limit and allowing a larger heterogeneous dose deposition in the tumor, but maintaining the prescribed minimum dose level, particularly in proton minibeam therapy. Methods: Three different longitudinally heterogeneous proton irradiation modes and a standard spread-out Bragg peak (SOBP) irradiation mode are simulated for their depth-dose curves under the constraint of maintaining a minimum prescribed dose anywhere in the tumor region. Symmetric dose distributions of two opposing directions are overlaid in a 25 cm-thick water phantom containing a 5 cm-thick tumor region. Interlaced planar minibeam dose distributions are compared to those of a broadbeam using the same longitudinal dose profiles. Results and Conclusion: All longitudinally heterogeneous proton irradiation modes show a dose reduction in the healthy tissue compared to the common SOBP mode in the case of broad proton beams. The proton minibeam cases show eventually a much larger mean cell survival and thus a further reduced equivalent uniform dose (EUD) in the healthy tissue than any broadbeam case. In fact, the irradiation mode using only one proton energy from each side shows better sparing capabilities in the healthy tissue than the common spread-out Bragg peak irradiation mode with the option of a better dose fall-off at the tumor edges and an easier technical realization, particularly in view of proton minibeam irradiation at ultra-high dose rates larger than ~10 Gy/s (so-called FLASH irradiation modes).


  • Open Access

    Proton Minibeam Radiation Therapy Reduces Side Effects in an In Vivo Mouse Ear Model

    by Stefanie Girst, Christoph Greubel, Judith Reindl, Christian Siebenwirth, Olga Zlobinskaya, Dietrich W.M. Walsh, Katarina Ilicic, Michaela Aichler, Axel Walch, Jan J. Wilkens, et al.


  • The influence of the channel size on the reduction of side effects in microchannel proton therapy

    by Stefanie Girst, Christoph Greubel, Judith Reindl, Christian Siebenwirth, Olga Zlobinskaya, Günther Dollinger, Thomas E. Schmid


  • Open Access

    Live cell imaging at the Munich ion microbeam SNAKE – a status report

    by Guido A Drexler, Christian Siebenwirth, Sophie E Drexler, Stefanie Girst, Christoph Greubel, Günther Dollinger, Anna A Friedl

    Ion microbeams are important tools in radiobiological research. Still, the worldwide number of ion microbeam facilities where biological experiments can be performed is limited. Even fewer facilities combine ion microirradiation with live-cell imaging to allow microscopic observation of cellular response reactions starting very fast after irradiation and continuing for many hours. At SNAKE, the ion microbeam facility at the Munich 14 MV tandem accelerator, a large variety of biological experiments are performed on a regular basis. Here, recent developments and ongoing research projects at the ion microbeam SNAKE are presented with specific emphasis on live-cell imaging experiments. An overview of the technical details of the setup is given, including examples of suitable biological samples. By ion beam focusing to submicrometer beam spot size and single ion detection it is possible to target subcellular structures with defined numbers of ions. Focusing of high numbers of ions to single spots allows studying the influence of high local damage density on recruitment of damage response proteins.


  • Open Access

    Subdiffusion Supports Joining Of Correct Ends During Repair Of DNA Double-Strand Breaks

    by S. Girst, V. Hable, G. A. Drexler, C. Greubel, C. Siebenwirth, M. Haum, A. A. Friedl, G. Dollinger

    The mobility of damaged chromatin regions in the nucleus may affect the probability of mis-repair. In this work, live-cell observation and distance tracking of GFP-tagged DNA damage response protein MDC1 was used to study the random-walk behaviour of chromatin domains containing radiation-induced DNA double-strand breaks (DSB). Our measurements indicate a subdiffusion-type random walk process with similar time dependence for isolated and clustered DSBs that were induced by 20 MeV proton or 43 MeV carbon ion micro-irradiation. As compared to normal diffusion, subdiffusion enhances the probability that both ends of a DSB meet, thus promoting high efficiency DNA repair. It also limits their probability of long-range movements and thus lowers the probability of mis-rejoining and chromosome aberrations.


  • Reduced side effects by proton microchannel radiotherapy: study in a human skin model

    by Olga Zlobinskaya, Stefanie Girst, Christoph Greubel, Volker Hable, Christian Siebenwirth, Dietrich W. M. Walsh, Gabriele Multhoff, Jan J. Wilkens, Thomas E. Schmid, Günther Dollinger

    The application of a microchannel proton irradiation was compared to homogeneous irradiation in a three-dimensional human skin model. The goal is to minimize the risk of normal tissue damage by microchannel irradiation, while preserving local tumor control through a homogeneous irradiation of the tumor that is achieved because of beam widening with increasing track length. 20 MeV protons were administered to the skin models in 10- or 50-μm-wide irradiation channels on a quadratic raster with distances of 500 μm between each channel (center to center) applying an average dose of 2 Gy. For comparison, other samples were irradiated homogeneously at the same average dose. Normal tissue viability was significantly enhanced after microchannel proton irradiation compared to homogeneous irradiation. Levels of inflammatory parameters, such as Interleukin-6, TGF-Beta, and Pro-MMP1, were significantly lower in the supernatant of the human skin tissue after microchannel irradiation than after homogeneous irradiation. The genetic damage as determined by the measurement of micronuclei in keratinocytes also differed significantly. This difference was quantified via dose modification factors (DMF) describing the effect of each irradiation mode relative to homogeneous X-ray irradiation, so that the DMF of 1.21 ± 0.20 after homogeneous proton irradiation was reduced to 0.23 ± 0.11 and 0.40 ± 0.12 after microchannel irradiation using 10- and 50-μm-wide channels, respectively. Our data indicate that proton microchannel irradiation maintains cell viability while significantly reducing inflammatory responses and genetic damage compared to homogeneous irradiation, and thus might improve protection of normal tissue after irradiation.