Arne Hothan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Arne Hothan has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Cornelius Weiss
3 shared publications- Gerd Huber
Institute of Biomechanics, Hamburg University of Technology (TUHH), Hamburg, Germany
3 shared publications - Michael M. Morlock
Institute of Biomechanics, Hamburg University of Technology (TUHH), Hamburg, Germany
3 shared publications - Norbert Hoffmann
Hamburg University of Technology
3 shared publications Kathrin Lewerenz
1 shared publicationMichael Morlock
1 shared publication
Latest Publications
- 23 May 2013
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 35 (10) , 1513-1517
Vibration transfer in the ball–stem contact interface of artificial hips
Audible squeaking has put the reputation of ceramic bearings for total hip replacements into question. Inter-articular friction induces vibrations in the ceramic head which are transferred through the head-taper interface to the femoral stem. If excited to sufficient amplitudes, squeaking can be emitted by the stem. Hence, the damping and amplification properties of this interface have a crucial influence on stem vibrations. The aim of this study was to determine the vibration transfer behavior between the head and the taper of a femoral stem and its dependence on the assembly force, in order to assess its influence on the development of audible squeaking. A ceramic head was assembled on a titanium femoral stem taper with high and low forces. Frequency response functions characterizing the head-stem interface were determined experimentally. The interface demonstrated negligible influence on vibration transfer in the squeaking frequency range (1-5 kHz). However its damping effect in lower and higher frequency ranges was significant and some areas of amplification were also found. Although squeaking vibration was not influenced by the particular interface studied, the method established can be utilized to trace taper designs with dynamic properties that decrease the susceptibility to squeaking.
- 23 May 2013
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 35 (10) , 1513-1517
Vibration transfer in the ball–stem contact interface of artificial hips
Audible squeaking has put the reputation of ceramic bearings for total hip replacements into question. Inter-articular friction induces vibrations in the ceramic head which are transferred through the head-taper interface to the femoral stem. If excited to sufficient amplitudes, squeaking can be emitted by the stem. Hence, the damping and amplification properties of this interface have a crucial influence on stem vibrations. The aim of this study was to determine the vibration transfer behavior between the head and the taper of a femoral stem and its dependence on the assembly force, in order to assess its influence on the development of audible squeaking. A ceramic head was assembled on a titanium femoral stem taper with high and low forces. Frequency response functions characterizing the head-stem interface were determined experimentally. The interface demonstrated negligible influence on vibration transfer in the squeaking frequency range (1-5 kHz). However its damping effect in lower and higher frequency ranges was significant and some areas of amplification were also found. Although squeaking vibration was not influenced by the particular interface studied, the method established can be utilized to trace taper designs with dynamic properties that decrease the susceptibility to squeaking.
- 1 July 2012
- Published by Elsevier in Journal of Biomechanics
- Vol. 45, S330
FRICTION SENSITIVITY OF MATERIALS IN ARTIFICIAL HIPS TO LUBRICATION SITUATION
- 1 July 2012
- Published by Elsevier in Journal of Biomechanics
- Vol. 45, S330
FRICTION SENSITIVITY OF MATERIALS IN ARTIFICIAL HIPS TO LUBRICATION SITUATION
- 1 March 2011
- Published by Elsevier in Journal of Biomechanics
- Vol. 44 (5) , 837-841
The influence of component design, bearing clearance and axial load on the squeaking characteristics of ceramic hip articulations
- 1 March 2011
- Published by Elsevier in Journal of Biomechanics
- Vol. 44 (5) , 837-841
The influence of component design, bearing clearance and axial load on the squeaking characteristics of ceramic hip articulations
- 1 January 2011
- Published by Elsevier in Clinical Biomechanics
- Vol. 26 (1) , 46-51
Deformation characteristics and eigenfrequencies of press-fit acetabular cups
- 1 January 2011
- Published by Elsevier in Clinical Biomechanics
- Vol. 26 (1) , 46-51
Deformation characteristics and eigenfrequencies of press-fit acetabular cups