MWMoritz Wagner

Moritz Wagner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Moritz Wagner has a total of 113 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Deep-Learning-Based Reconstruction of Single-Breath-Hold 3 mm HASTE Improves Abdominal Image Quality and Reduces Acquisition Time: A Quantitative Analysis

    by Felix Kubicka, Qinxuan Tan, Tom Meyer, Dominik Nickel, Elisabeth Weiland, Moritz Wagner, Stephan Rodrigo Marticorena Garcia

    Purpose: Breath-hold T2-weighted half-Fourier acquisition single-shot turbo spin echo (HASTE) magnetic resonance imaging (MRI) of the upper abdomen with a slice thickness below 5 mm suffers from high image noise and blurring. The purpose of this prospective study was to improve image quality and accelerate imaging acquisition by using single-breath-hold T2-weighted HASTE with deep learning (DL) reconstruction (DL-HASTE) with a 3 mm slice thickness. Method: MRI of the upper abdomen with DL-HASTE was performed in 35 participants (5 healthy volunteers and 30 patients) at 3 Tesla. In a subgroup of five healthy participants, signal-to-noise ratio (SNR) analysis was used after DL reconstruction to identify the smallest possible layer thickness (1, 2, 3, 4, 5 mm). DL-HASTE was acquired with a 3 mm slice thickness (DL-HASTE-3 mm) in 30 patients and compared with 5 mm DL-HASTE (DL-HASTE-5 mm) and with standard HASTE (standard-HASTE-5 mm). Image quality and motion artifacts were assessed quantitatively using Laplacian variance and semi-quantitatively by two radiologists using five-point Likert scales. Results: In the five healthy participants, DL-HASTE-3 mm was identified as the optimal slice (SNR 23.227 ± 3.901). Both DL-HASTE-3 mm and DL-HASTE-5 mm were assigned significantly higher overall image quality scores than standard-HASTE-5 mm (Laplacian variance, both p < 0.001; Likert scale, p < 0.001). Compared with DL-HASTE-5 mm (1.10 × 10−5 ± 6.93 × 10−6), DL-HASTE-3 mm (1.56 × 10−5 ± 8.69 × 10−6) provided a significantly higher SNR Laplacian variance (p < 0.001) and sharpness sub-scores for the intestinal tract, adrenal glands, and small anatomic structures (bile ducts, pancreatic ducts, and vessels; p < 0.05). Lesion detectability was rated excellent for both DL-HASTE-3 mm and DL-HASTE-5 mm (both: 5 [IQR4–5]) and was assigned higher scores than standard-HASTE-5 mm (4 [IQR4–5]; p < 0.001). DL-HASTE reduced the acquisition time by 63–69% compared with standard-HASTE-5 mm (p < 0.001). Conclusions: DL-HASTE is a robust abdominal MRI technique that improves image quality while at the same time reducing acquisition time compared with the routine clinical HASTE sequence. Using ultra-thin DL-HASTE-3 mm results in an even greater improvement with a similar SNR.


  • Open Access

    Deep learning enabled near-isotropic CAIPIRINHA VIBE in the nephrogenic phase improves image quality and renal lesion conspicuity

    by Qinxuan Tan, Jingyu Miao, Leila Nitschke, Marcel Dominik Nickel, Markus Herbert Lerchbaumer, Tobias Penzkofer, Sebastian Hofbauer, Robert Peters, Bernd Hamm, Dominik Geisel, et al.


  • Differentiation of Predominantly Osteoblastic and Osteolytic Spine Metastases by Using Susceptibility-weighted MRI

    by Sarah M. Böker, Lisa C. Adams, Yvonne Y. Bender, Ute L. Fahlenkamp, Moritz Wagner, Bernd Hamm, Marcus R. Makowski

    Susceptibility-weighted MRI enables the differentiation between predominantly osteoblastic and osteolytic spine metastases with a higher sensitivity and specificity than standard MRI sequences. PurposeTo evaluate the use of susceptibility-weighted MRI for the differentiation of predominantly osteoblastic and osteolytic spine metastases.Materials and MethodsFor this prospective study, 53 study participants (mean age, 54.5 years ± 14.3 [range, 22–88 years]; 27 men with a mean age of 55.3 years ± 12.7 [range, 22–72 years] and 26 women with a mean age of 53.8 years ± 15.7 [range, 23–88 years]) with clinically suspected spine metastases underwent imaging with standard MRI sequences, susceptibility-weighted MRI, and CT. Sensitivities and specificities of MRI sequences for the detection of predominantly osteoblastic and osteolytic metastases were determined by using CT as the reference standard. The metastases-to–vertebral body signal intensity ratio (MVR) was calculated to compare modalities. Phantom measurements were obtained to correlate bone densities between MRI sequences and CT.ResultsA total of 64 metastases (38 predominantly osteoblastic, 26 predominantly osteolytic) were detected. Susceptibili...


  • Detection of vessel wall calcifications in vertebral arteries using susceptibility weighted imaging

    by Lisa C. Adams, Sarah M. Böker, Yvonne Y. Bender, Eva M. Fallenberg, Moritz Wagner, Thomas Liebig, Bernd Hamm, Marcus R. Makowski

    Purpose Calcification of the brain supplying arteries has been linked to an increased risk for cerebrovascular disease. The purpose of this study was to test the potential of susceptibility weighted MR imaging (SWMR) for the detection of vertebral artery calcifications, based on CT as a reference standard. Methods Four hundred seventy-four patients, who had received head CT and 1.5 T MR scans with SWMR, including the distal vertebral artery, between January 2014 and December 2016, were retrospectively evaluated and 389 patients were included. Sensitivity and specificity for the detection of focal calcifications and intra- and interobserver agreement were calculated for SWMR and standard MRI, using CT as a standard of reference. The diameter of vertebral artery calcifications was used to assess correlations between imaging modalities. Furthermore, the degree of vessel stenosis was determined in 30 patients, who had received an additional angiography. Results On CT scans, 40 patients showed a total of 52 vertebral artery calcifications. While SWMR reached a sensitivity of 94% (95% CI 84–99%) and a specificity of 97% (95% CI 94–98%), standard MRI yielded a sensitivity of 33% (95% CI 20–46%), and a specificity of 93% (95% CI 90–96%). Linear regression analysis of size measurements confirmed a close correlation between SWMR and CT measurements (R 2 = 0.74, p < 0.001). Compared to standard MRI (ICC = 0.52; CI 0.45–0.59), SWMR showed a higher interobserver agreement for calcification measurements (ICC = 0.84; CI 0.81–0.87). Conclusions For detection of distal vertebral artery calcifications, SWMR demonstrates a performance comparable to CT and considerably higher than conventional MRI.


  • Evaluation of sclerosis in Modic changes of the spine using susceptibility-weighted magnetic resonance imaging

    by Sarah M. Böker, Yvonne Y. Bender, Lisa C. Adams, Eva M. Fallenberg, Moritz Wagner, Bernd Hamm, Marcus R. Makowski


  • Nonenhanced magnetic resonance angiography (MRA) of the calf arteries at 3 Tesla: intraindividual comparison of 3D flow-dependent subtractive MRA and 2D flow-independent non-subtractive MRA

    by Gesine Knobloch, Marie-Teres Lauff, Sebastian Hirsch, Carsten Schwenke, Bernd Hamm, Moritz Wagner

    To prospectively compare 3D flow-dependent subtractive MRA vs. 2D flow-independent non-subtractive MRA for assessment of the calf arteries at 3 Tesla. Forty-two patients with peripheral arterial occlusive disease underwent nonenhanced MRA of calf arteries at 3 Tesla with 3D flow-dependent subtractive MRA (fast spin echo sequence; 3D-FSE-MRA) and 2D flow-independent non-subtractive MRA (balanced steady-state-free-precession sequence; 2D-bSSFP-MRA). Moreover, all patients underwent contrast-enhanced MRA (CE-MRA) as standard-of-reference. Two readers performed a per-segment evaluation for image quality (4 = excellent to 0 = non-diagnostic) and severity of stenosis. Image quality scores of 2D-bSSFP-MRA were significantly higher compared to 3D-FSE-MRA (medians across readers: 4 vs. 3; p < 0.0001) with lower rates of non-diagnostic vessel segments on 2D-bSSFP-MRA (reader 1: <1 % vs. 15 %; reader 2: 1 % vs. 29 %; p < 0.05). Diagnostic performance of 2D-bSSFP-MRA and 3D-FSE-MRA across readers showed sensitivities of 89 % (214/240) vs. 70 % (168/240), p = 0.0153; specificities: 91 % (840/926) vs. 63 % (585/926), p < 0.0001; and diagnostic accuracies of 90 % (1054/1166) vs. 65 % (753/1166), p < 0.0001. 2D flow-independent non-subtractive MRA (2D-bSSFP-MRA) is a robust nonenhanced MRA technique for assessment of the calf arteries at 3 Tesla with significantly higher image quality and diagnostic accuracy compared to 3D flow-dependent subtractive MRA (3D-FSE-MRA). • 2D flow-independent non-subtractive MRA (2D-bSSFP-MRA) is a robust NE-MRA technique at 3T • 2D-bSSFP-MRA outperforms 3D flow-dependent subtractive MRA (3D-FSE-MRA) as NE-MRA of calf arteries • 2D-bSSFP-MRA is a promising alternative to CE-MRA for calf PAOD evaluation.


  • Novel Dynamic Hepatic Magnetic Resonance Imaging Strategy Using Advanced Parallel Acquisition, Rhythmic Breath-Hold Technique, and Gadoxetate Disodium Enhancement

    by Ute Lina Fahlenkamp, Moritz Wagner, Dominik Nickel, Ulrich Adam, Karsten Krueger, Matthias Taupitz, Carsten Schwenke, Alexander Huppertz

    Objective The aim of the study was to evaluate image quality of a dynamic hepatic magnetic resonance (MR) imaging strategy based on advanced parallel acquisition combined with rhythmic breath-hold and gadoxetate disodium enhancement. Materials and Methods Twenty-seven patients (21 male/6 female; mean age, 57.3 years) were enrolled in this institutional review board–approved study and underwent MR imaging at 3 T. The sequence (T1 3-dimensional gradient-recalled echo; acceleration factor, 4; reconstruction mode; controlled aliasing in parallel imaging resulting in higher acceleration factors; acquisition time, 10.4 seconds) was repeated at 8 fixed time points within the 3 minutes after contrast agent injection. Image quality was evaluated on a 5-point scale (1, excellent; 5, nondiagnostic). Dynamic sequences were classified according to perfusion phases and contrast characteristics. Artifacts and position of the liver in the z axis were recorded and analyzed. Results Overall image quality was found to be 1.44 (95% confidence interval, 1.18–1.71). Contrast was scored as excellent in 25 of 27 patients for central vessels and 22 of 27 patients for peripheral vessels. Adequate-quality arterial-phase images were obtained in all 27 patients. Double arterial and single arterial phases were acquired in 13 of 27 and 14 of 27 patients (n = 6 arterial dominant, n = 8 early arterial phases), respectively. In 1 (3.7%) of 27 patients, severe respiratory artifacts were seen during an early arterial phase. Artifacts were observed in 21 of 27 patients and rated as mild in 19 of these. Compromised quality was related to receiver coils (17 of 29), parallel imaging (6 of 29), breathing (3 of 29), and other causes (3 of 29). The position of the liver throughout the dynamic phases was highly constant, with a greatest mean shift of +2.9 mm throughout the first dynamic acquisition. Conclusions Advanced parallel acquisition with rhythmic breath-hold and gadoxetate injection allows arterial phase imaging without breathing artifacts; a decelerated yet normal breathing pattern results in very robust breath-hold depth.


  • Nonenhanced peripheral MR-angiography (MRA) at 3 Tesla: evaluation of quiescent-interval single-shot MRA in patients undergoing digital subtraction angiography

    by Moritz Wagner, Gesine Knobloch, Martin Gielen, Marie-Teres Lauff, Valentina Romano, Bernd Hamm, Thomas Kröncke

    Quiescent-interval single-shot MRA (QISS-MRA) is a promising nonenhanced imaging technique for assessment of peripheral arterial disease (PAD). Previous studies at 3 Tesla included only very limited numbers of patients for correlation of QISS-MRA with digital subtraction angiography (DSA) as standard of reference (SOR). The aim of this prospective institutional review board-approved study was to compare QISS-MRA at 3 Tesla with DSA in a larger patient group. Our study included 32 consecutive patients who underwent QISS-MRA, contrast-enhanced MRA (CE-MRA), and DSA. Two readers independently performed a per-segment evaluation of QISS-MRA and CE-MRA for image quality and identification of non-significant stenosis (p = 0.80; specificity: 93.9 % (741/789) versus 95.7 % (755/789), p = 0.25; and diagnostic accuracy: 92.4 % (852/922) versus 93.8 % (865/922), p = 0.35. In conclusion, using DSA as SOR, QISS-MRA and CE-MRA at 3 Tesla showed similar diagnostic accuracy in the assessment of PAD. A limitation of QISS-MRA was the lower rate of assessable vessel segments compared to CE-MRA.