DPDouglas L. Packer

Douglas L. Packer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Douglas L. Packer has a total of 38 co-authors. Here are the top co-authors by number of shared publications:

  • T. Jared Bunch

    Division of Cardiovascular Diseases, Department of Internal Medicine, Mayo Clinic, Rochester, Minnesota, USA

    5 shared publications
  • Kristi H. Monahan

    Division of Cardiovascular Diseases, Department of Internal Medicine, Mayo Clinic and College of Medicine, Rochester, Minnesota

    4 shared publications
  • Susan B. Johnson

    Cardiac Translational Electrophysiology Laboratory , Saint Marys Hospital Complex, Mayo Clinic and Foundation , 2-416 Alfred Building, Rochester, MN 55902 , USA

    4 shared publications
  • Benhur D. Henz

    Cardiac Translational Electrophysiology Laboratory , Saint Marys Hospital Complex, Mayo Clinic and Foundation , 2-416 Alfred Building, Rochester, MN 55902 , USA

    3 shared publications
  • David O. Hodge

    Department of Health Sciences Research, Mayo Clinic and College of Medicine, Rochester, Minnesota

    3 shared publications
  • Yasuo Okumura

    Cardiac Translational Electrophysiology Laboratory , Saint Marys Hospital Complex, Mayo Clinic and Foundation , 2-416 Alfred Building, Rochester, MN 55902 , USA

    3 shared publications

Latest Publications

  • Contributors Toward Pulmonary Vein Restenosis Following Successful Intervention

    by R. Jay Widmer, Erin A. Fender, David O. Hodge, Kristi H. Monahan, Lauri A. Peterson, David R. Holmes, Douglas L. Packer


  • Severe Pulmonary Vein Stenosis Resulting From Ablation for Atrial Fibrillation

    by Erin A. Fender, R. Jay Widmer, David O. Hodge, George M. Cooper, Kristi H. Monahan, Laurie A. Peterson, David R. Holmes, Douglas L. Packer

    Background: The frequency of pulmonary vein stenosis (PVS) after ablation for atrial fibrillation has decreased, but it remains a highly morbid condition. Although treatment strategies including pulmonary vein dilation and stenting have been described, the long-term impacts of these interventions are unknown. We evaluated the presentation of severe PVS, and examined the risk for restenosis after intervention using either balloon angioplasty (BA) alone or BA with stenting. Methods: This was a prospective, observational study of 124 patients with severe PVS evaluated between 2000 and 2014. Results: All 124 patients were identified as having severe PVS by computed tomography in 219 veins. One hundred two patients (82%) were symptomatic at diagnosis. The most common symptoms were dyspnea (67%), cough (45%), fatigue (45%), and decreased exercise tolerance (45%). Twenty-seven percent of patients experienced hemoptysis. Ninety-two veins were treated with BA, 86 were treated with stenting, and 41 veins were not treated. A 94% acute procedural success rate was observed and did not differ by initial management. Major procedural complications occurred in 4 of the 113 patients (3.5%) who underwent invasive assessment, and minor complications occurred in 15 patients (13.3%). Overall, 42% of veins developed restenosis including 27% of veins (n=23) treated with stenting and 57% of veins (n=52) treated with BA. The 3-year overall rate of restenosis was 37%, with 49% of BA-treated veins and 25% of stented veins developing restenosis (hazard ratio, 2.77; 95% confidence interval, 1.72–4.45; P P <0.001). Conclusions: The diagnosis of PVS is challenging because of nonspecific symptoms and the need for dedicated pulmonary vein imaging. There is no difference in acute success by type of initial intervention; however, stenting significantly reduces the risk of subsequent pulmonary vein restenosis in comparison with BA.


  • Open Access

    New generation of electro-anatomic mapping: full intracardiac ultrasound image integration

    by Douglas L. Packer, Susan B. Johnson, Mark W. Kolasa, Thomas J. Bunch, Benhur D. Henz, Yasuo Okumura

    Surrogate electro-anatomic-derived geometries are used as the three-dimensional (3D) basis for mapping of cardiac arrhythmias. While merged computed tomography (CT) imaging may provide stellar pulmonary vein (PV) and left atrial (LA) anatomy, the applied scans must be obtained prior to ablation, and may not reflect physiologic conditions at the time of intervention. Patient-specific, ultrasound-derived 3D imaging has been developed as an alternative basis for new generation electro-anatomic mapping. An electro-anatomic sensor positioned at the tip of the phased-array intracardiac ultrasound catheter, provides the means to specify both location and orientation of each image as the ‘context’ for creating the 3D volumes for co-registration with electro-anatomic mapping. Specific anatomic details such as the pulmonary veins, membranous fossa, papillary muscles, or valve structures derived from real-time imaging can also be integrated into each segmented volume. This presentation reviews the basis and methods for this novel multi-modality image fusion for the creation of robust, nearly real-time anatomic images for guiding electro-anatomic mapping and ablation without requiring pre-acquired CT image sets, with accompanying limitations.


  • Substrate and Procedural Predictors of Outcomes After Catheter Ablation for Atrial Fibrillation in Patients with Hypertrophic Cardiomyopathy

    by T. Jared Bunch, Thomas M Munger, Paul A Friedman, Samuel J Asirvatham, Peter A Brady, Yong‐Mei Cha, Robert F Rea, Win‐Kuang Shen, Brian D Powell, Steve R Ommen, et al.

    Background: Hypertrophic cardiomyopathy (HCM) is often accompanied by atrial fibrillation (AF) due to diastolic dysfunction, elevated left atrial pressure, and enlargement. Although catheter ablation for drug‐refractory AF is an effective treatment, the efficacy in HCM remains to be established. Methods: Thirty‐three consecutive patients (25 male, age 51 ± 11 years) with HCM underwent pulmonary vein (PV) isolation (n = 8) or wide area circumferential ablation with additional linear ablation (n = 25) for drug‐refractory AF. Twelve‐lead and 24‐hour ambulating ECGs, echocardiograms, event monitor strips, and SF 36 quality of life (QOL) surveys were obtained before ablation and for routine follow‐up. Results: Twenty‐one (64%) patients had paroxysmal AF and 12 (36%) had persistent/permanent AF for 6.2 ± 5.2 years. The average ejection fraction was 0.63 ± 0.12. The average left atrial volume index was 70 ± 24 mL/m2. Over a follow‐up of 1.5 ± 1.2 years, 1‐year survival with AF elimination was 62%(Confidence Interval [CI]: 66‐84) and with AF control was 75%(CI: 66‐84). AF control was less likely in patients with a persistent/chronic AF, larger left atrial volumes, and more advanced diastolic disease. Additional linear ablation may improve outcomes in patient with severe left atrial enlargement and more advanced diastolic dysfunction. Two patients had a periprocedureal TIA, one PV stenosis, and one died after mitral valve replacement from prosthetic valve thrombosis. QOL scores improved from baseline at 3 and 12 months. Conclusion: Outcomes after AF ablation in patients with HCM are favorable. Diastolic dysfunction, left atrial enlargement, and AF subtype influence outcomes. Future studies of rhythm management approaches in HCM patients are required to clarify the optimal clinical approach.


  • Mechanism of Tissue Heating During High Intensity Focused Ultrasound Pulmonary Vein Isolation: Implications for Atrial Fibrillation Ablation Efficacy and Phrenic Nerve Protection

    by Yasuo Okumura, Mark W. Kolasa, Susan B. Johnson, T. Jared Bunch, Benhur D. Henz, Christine J. O'BRien, Dylan V. Miller, Douglas L. Packer

    Introduction: The purpose of this study was to examine tissue temperatures around pulmonary veins (PVs) during high intensity focused ultrasound (HIFU) balloon ablation for atrial fibrillation. The thermodynamics and extent of PV and phrenic nerve (PN) heating during HIFU ablation have not been established. Methods and Results: Tissue temperatures were recorded from epicardial thermocouples at right superior (RS) PV orifice and PN in eight dogs undergoing 51 RSPV HIFU ablations (40 seconds, 40 W). Maximum tissue temperatures, reflected by 288 recording profiles, were negatively correlated with distance from balloon surface (r =–0.79, P < 0.001). Average maximum RSPV temperature was 56.8 ± 16.8 °C (distance: 6.6 ± 4.1 mm), resulting in full‐thickness, circumferential PV isolation in 7 of 8 animals. Direct local mechanical heating restricted to the focused ultrasound zone showed temperature rise to ≥50°C within 10 seconds to a maximum temperature of 82.6 ± 8.9°C (n = 31). Apparent conductive heating showed gradual heating patterns ( Conclusions: HIFU ablation is highly effective in generating temperatures needed for full‐thickness, circumferential ablation through rapid direct mechanical heating. Gradual heating of surrounding tissue supports the presence of conductive heating. This study also discloses direct HIFU effects as the mechanism of PN injury occurring within 4–7 mm from balloon surface.


  • Three-Dimensional Ultrasound for Image-Guided Mapping and Intervention

    by Yasuo Okumura, Benhur D. Henz, Susan B. Johnson, T. Jared Bunch, Christine J. O’bRien, David O. Hodge, Andres Altman, Assaf Govari, Douglas L. Packer

    Multiple factors create discrepancies between electroanatomic maps and merged, preacquired computed tomographic images used in guiding atrial fibrillation ablation. Therefore, a Carto-based 3D ultrasound image system (Biosense Webster Inc) was validated in an animal model and tested in 15 atrial fibrillation patients. Twelve dogs underwent evaluation using a newly developed Carto-based 3D ultrasound system. After fiducial clip markers were percutaneously implanted at critical locations in each cardiac chamber, 3D ultrasound geometries, derived from a family of 2D intracardiac echocardiographic images, were constructed. Point-source error of 3D ultrasound-derived geometries, assessed by actual real-time 2D intracardiac echocardiographic clip sites, was 2.1+/-1.1 mm for atrial and 2.4+/-1.2 mm for ventricular sites. These errors were significantly less than the variance on CartoMerge computed tomographic images (atria: 3.3+/-1.6 mm; ventricles: 4.8+/-2.0 mm; P<0.001 for both). Target ablation at each clip, guided only by 3D ultrasound-derived geometry, resulted in lesions within 1.1+/-1.1 mm of the actual clips. Pulmonary vein ablation guided by 3D ultrasound-derived geometry resulted in circumferential ablative lesions. Mapping in 15 patients produced modestly smaller 3D ultrasound versus electroanatomic map left atrial volumes (98+/-24 cm(3) versus 109+/-25 cm(3), P<0.05). Three-dimensional ultrasound-guided pulmonary vein isolation and linear ablation in these patients were successfully performed with confirmation of pulmonary vein entrance/exit block. These data demonstrate that 3D ultrasound images seamlessly yield anatomically accurate chamber geometries. Image volumes from the ultrasound system are more accurate than possible with CartoMerge computed tomographic imaging. This clinical study also demonstrates the initial feasibility of this guidance system for ablation in patients with atrial fibrillation.


  • Outcomes After Cardiac Perforation During Radiofrequency Ablation of the Atrium

    by T. Jared Bunch, Samuel J. Asirvatham, Paul A. Friedman, Kristi H. Monahan, Thomas M. Munger, Robert F. Rea, Lawrence J. Sinak, Douglas L. Packer

    Background: Perforation during catheter procedures in either the atrium or ventricle is relatively uncommon, but potentially fatal if tamponade ensues. This study analyzes the occurrence and outcomes of cardiac perforation during catheter‐based radiofrequency ablation procedures in the left atrium. Methods: All patients with a periprocedure perforation who have undergone radiofrequency ablation for atrial fibrillation (AF) or tachycardia were included. Results: Of 632 procedures performed from January 1999 to October 2004, 15 (2.4%) were complicated by perforation requiring pericardiocentesis. The perforation site was left atrium in 9 (60.0%), right atrium in 1 (6.7%), and right ventricle in 5 (33.3%). Intracardiac echocardiography was used in 13 (86.7%) and revealed an effusion before overt instability in 11 (73.3%). Thirteen (86.7%) patients developed a blood pressure Conclusion: The incidence of perforation during ablation of the left atrium is low. Most perforations occur in the left atrium; however, few require surgical closure. Although less than with uncomplicated procedures, the majority of patients with complete ablations achieve long‐term elimination of AF.


  • Analysis of Catheter-Tip (8-mm) and Actual Tissue Temperatures Achieved During Radiofrequency Ablation at the Orifice of the Pulmonary Vein

    by T. Jared Bunch, G. Keith Bruce, Susan B. Johnson, Alvaro Sarabanda, Mark A. Milton, Douglas L. Packer

    Background— Many ablative approaches in or near the orifice of the pulmonary vein (PV) have demonstrated success in eliminating atrial fibrillation. Despite current practice, there are no data regarding the in vivo efficacy and safety of an 8-mm catheter tip for ablation at the PV orifice. Methods and Results— Ten mongrel dogs were studied. Thermocouples were implanted in the atrial muscle of the PV orifice. Intracardiac echocardiography monitored catheter position, tip/tissue orientation, and microbubble formation. Ninety-four ablations were performed for 120 seconds. A temperature discrepancy >10°C between the catheter tip and tissue occurred during 47 (50%) of the ablations. Despite termination of energy delivery, the average tissue temperature remained within 1°C of the achieved steady state for 9 seconds. A temperature discrepancy >10°C was more common in the right superior PV, with oblique catheter positioning, when tissue temperatures were >60°C or 80°C, and with type 1 or type 2 microbubble formation. However, microbubbles were not present in 7 (13%, type 1) and 10 (40%, type 2) ablations with tissue temperatures >80°C. The maximum tissue temperature achieved with non–full-thickness lesions was 47.3±7.4°C vs 75.9±11.7°C ( P Conclusions— Marked discrepancies between catheter-tip and tissue temperatures occurred with higher temperatures, prolonged ablation times, and unfavorable catheter thermistor–tissue contact. Also, these data suggest a conservative approach to atrial ablation, because full-thickness lesions were obtained when tissue temperatures reached 50°C to 60°C and the tissue retained high heat levels despite termination of radiofrequency energy. Finally, microbubbles are inconsistent markers of tissue overheating.


  • Progress in Nonpharmacologic Therapy of Atrial Fibrillation

    by Douglas L. Packer, Sam Asirvatham, Thomas M. Munger