Nicholas J. Pastis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nicholas J. Pastis has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
Gerard A. Silvestri
Department of Medicine, Division of Pulmonary and Critical Care, Medical University of South Carolina, Charleston
6 shared publicationsNichole T. Tanner
Division of Pulmonary and Critical Care, Medical University of South Carolina, Charleston, SC
3 shared publications- Brian S. Furukawa
Pulmonary, Critical Care, Allergy and Sleep Medicine †Pathology and Laboratory Medicine, Medical University of South Carolina, Charleston, SC
2 shared publications Charlton B. Strange
2 shared publicationsFrank Schippers
PAION Deutschland GmbH
2 shared publications- Gerard A. Silvestri
Thoracic Oncology Research Group, Division of Pulmonary and Critical Care Medicine, Medical University of South Carolina, Charleston, South Carolina
2 shared publications
Latest Publications
- 8 July 2021
- Published by Wolters Kluwer Health in Journal of Bronchology & Interventional Pulmonology
- Vol. 29 (1) , 54-61
Correlation of Vital Signs and Depth of Sedation by Modified Observer’s Assessment of Alertness and Sedation (MOAA/S) Scale in Bronchoscopy
Background: With complex, lengthy bronchoscopies, there is a need for safe, effective sedation. Most bronchoscopists strive for moderate sedation, though often difficult without compromising vital signs. The Modified Observer’s Assessment of Alertness and Sedation (MOAA/S) scale is a validated 6-point scale assessing responsiveness of patients coinciding with the American Society of Anesthesiologists (ASA) continuum of sedation. It is commonly used in studying bronchoscopic sedation, but depth of sedation by MOAA/S and correlation with vital signs and adverse events has not been determined. Methods: This study was a post hoc analysis of a prospective, double-blind, randomized trial evaluating the safety and efficacy of remimazolam. MOAA/S and corresponding vital signs were used to assess the effect of the level of sedation on vital signs and adverse events. Results: A total of 23,341 MOAA/S scores from 431 patients were recorded. Older and higher ASA class patients spent more time in deeper sedation (MOAA/S 0 to 1) (6% vs. 2%, P=0.01). Oxygen saturation was equal in deep sedation (MOAA/S 0 to 1) (97±3%) compared with moderate sedation (96±3%) (P=0.11). Mean systolic and diastolic blood pressures were significantly lower when comparing MOAA/S 0 to 1 to MOAA/S 5 (systolic blood pressure: 126±19 vs. 147±24 mm Hg, PPP=0.07). Respiratory rate was also comparable with moderate and deep sedation (17±5 vs. 18±6 beats/min, P=0.94). Conclusion: There was no clinically meaningful correlation between vital signs and depth of sedation assessed by MOAA/S. Older and higher ASA class patients spend more time in deeper sedation. However, when in deep sedation, there was no difference in vital signs other than a slightly increased incidence of clinically insignificant hypotension.
- 8 July 2021
- Published by Wolters Kluwer Health in Journal of Bronchology & Interventional Pulmonology
- Vol. 29 (1) , 54-61
Correlation of Vital Signs and Depth of Sedation by Modified Observer’s Assessment of Alertness and Sedation (MOAA/S) Scale in Bronchoscopy
Background: With complex, lengthy bronchoscopies, there is a need for safe, effective sedation. Most bronchoscopists strive for moderate sedation, though often difficult without compromising vital signs. The Modified Observer’s Assessment of Alertness and Sedation (MOAA/S) scale is a validated 6-point scale assessing responsiveness of patients coinciding with the American Society of Anesthesiologists (ASA) continuum of sedation. It is commonly used in studying bronchoscopic sedation, but depth of sedation by MOAA/S and correlation with vital signs and adverse events has not been determined. Methods: This study was a post hoc analysis of a prospective, double-blind, randomized trial evaluating the safety and efficacy of remimazolam. MOAA/S and corresponding vital signs were used to assess the effect of the level of sedation on vital signs and adverse events. Results: A total of 23,341 MOAA/S scores from 431 patients were recorded. Older and higher ASA class patients spent more time in deeper sedation (MOAA/S 0 to 1) (6% vs. 2%, P=0.01). Oxygen saturation was equal in deep sedation (MOAA/S 0 to 1) (97±3%) compared with moderate sedation (96±3%) (P=0.11). Mean systolic and diastolic blood pressures were significantly lower when comparing MOAA/S 0 to 1 to MOAA/S 5 (systolic blood pressure: 126±19 vs. 147±24 mm Hg, PPP=0.07). Respiratory rate was also comparable with moderate and deep sedation (17±5 vs. 18±6 beats/min, P=0.94). Conclusion: There was no clinically meaningful correlation between vital signs and depth of sedation assessed by MOAA/S. Older and higher ASA class patients spend more time in deeper sedation. However, when in deep sedation, there was no difference in vital signs other than a slightly increased incidence of clinically insignificant hypotension.
- 1 January 2021
- Published by Wolters Kluwer Health in Journal of Bronchology & Interventional Pulmonology
- Vol. 28 (1) , 3-5
In Search of the Holy Grail Improving the Diagnostic Yield in Navigational Bronchoscopy
- 1 January 2021
- Published by Wolters Kluwer Health in Journal of Bronchology & Interventional Pulmonology
- Vol. 28 (1) , 3-5
In Search of the Holy Grail Improving the Diagnostic Yield in Navigational Bronchoscopy
- Open Access
- 1 January 2019
- Published by SAGE Publications in Journal of Medical Education and Curricular Development
- Vol. 6
A Pilot Study of Simulation Training in Difficult Bag Mask Ventilation Using a Computerized Patient Simulator
Bag mask ventilation (BMV) is fundamental to airway management. Simulation is effective in airway management training, but its effectiveness for difficult BMV training is less clear. We evaluated the difference between type of training (simulation vs on patients) and the pass rate on a post-test on patients. A single center pilot study was performed with 32 medical students randomized to participate in difficult BMV training on simulators or patients. Pre- and post-training tests on the simulator and on patients were recorded. Surveys of trainee confidence level were collected. The primary goal was to estimate the difference between type of training (simulation vs on patients) and the pass rate on the post-test on patients with an improvement of 10% or more in passing rate considered as a meaningful improvement. Secondary outcomes included whether or not participants passed the simulator post-test, post-test on patient confidence, and pre- and post-test confidence. Participants trained on the simulator had 13% higher passing rate on the post-test on patients compared to participants trained on patients (88% vs 75%). In addition, subjects that passed the simulator post-test had 11 times the odds of passing a post-test on patients relative to subjects that did not pass the simulator post-test (P = 0.023, odds ratio = 11.0, 95% confidence interval [CI] = 1.48-81.6). Post-training confidence levels were higher among those who passed the simulator pre-test and post-test and received simulator training. Simulation training for difficult BMV led to a higher passing rate on a post-test on patients compared to those trained on patients. This finding will need to be confirmed in larger randomized controlled trials. Successfully completing difficult BMV training on a simulator with a passing grade correlated with passing a test on difficult BMV on patients.
- 1 January 2019
- Published by SAGE Publications in Journal of Medical Education and Curricular Development
- Vol. 6
Open AccessA Pilot Study of Simulation Training in Difficult Bag Mask Ventilation Using a Computerized Patient Simulator
Bag mask ventilation (BMV) is fundamental to airway management. Simulation is effective in airway management training, but its effectiveness for difficult BMV training is less clear. We evaluated the difference between type of training (simulation vs on patients) and the pass rate on a post-test on patients. A single center pilot study was performed with 32 medical students randomized to participate in difficult BMV training on simulators or patients. Pre- and post-training tests on the simulator and on patients were recorded. Surveys of trainee confidence level were collected. The primary goal was to estimate the difference between type of training (simulation vs on patients) and the pass rate on the post-test on patients with an improvement of 10% or more in passing rate considered as a meaningful improvement. Secondary outcomes included whether or not participants passed the simulator post-test, post-test on patient confidence, and pre- and post-test confidence. Participants trained on the simulator had 13% higher passing rate on the post-test on patients compared to participants trained on patients (88% vs 75%). In addition, subjects that passed the simulator post-test had 11 times the odds of passing a post-test on patients relative to subjects that did not pass the simulator post-test (P = 0.023, odds ratio = 11.0, 95% confidence interval [CI] = 1.48-81.6). Post-training confidence levels were higher among those who passed the simulator pre-test and post-test and received simulator training. Simulation training for difficult BMV led to a higher passing rate on a post-test on patients compared to those trained on patients. This finding will need to be confirmed in larger randomized controlled trials. Successfully completing difficult BMV training on a simulator with a passing grade correlated with passing a test on difficult BMV on patients.
- Top Cited Papers
Safety and Efficacy of Remimazolam Compared With Placebo and Midazolam for Moderate Sedation During Bronchoscopy
- 1 March 2017
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 14 (3) , 309-310
Chronic Obstructive Pulmonary Disease as a Lung Cancer Risk: Worth Its Weight in “GOLD”
- 1 March 2017
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 14 (3) , 309-310
Chronic Obstructive Pulmonary Disease as a Lung Cancer Risk: Worth Its Weight in “GOLD”
- 1 October 2016
- Published by Wolters Kluwer Health in Journal of Bronchology & Interventional Pulmonology
- Vol. 23 (4) , 336-339
Diagnosing Hodgkin Lymphoma From an Endobronchial Ultrasound Core Needle Biopsy
Hodgkin lymphoma (HL) commonly presents as isolated mediastinal adenopathy. Although there is evidence to support minimally invasive techniques such as endobronchial ultrasound (EBUS) fine-needle aspiration as the initial diagnostic test for suspected lymphoma involving the mediastinum, it consistently performs the poorest at definitively diagnosing HL for a variety of reasons, and therefore histology specimens are usually required. We present a case of HL presenting as isolated mediastinal adenopathy that was definitively diagnosed on EBUS using a 22 G coring needle in which cellular and histologic specimens were obtained, allowing the core biopsy to be fixed in formalin and treated as a surgical specimen. The patient started treatment soon after the procedure without requiring any further invasive tests. Although it seems intuitive that a coring EBUS needle would be advantageous in diseases such as HL, further studies are needed before definitive recommendations can be made.
- 1 October 2016
- Published by Wolters Kluwer Health in Journal of Bronchology & Interventional Pulmonology
- Vol. 23 (4) , 336-339
Diagnosing Hodgkin Lymphoma From an Endobronchial Ultrasound Core Needle Biopsy
Hodgkin lymphoma (HL) commonly presents as isolated mediastinal adenopathy. Although there is evidence to support minimally invasive techniques such as endobronchial ultrasound (EBUS) fine-needle aspiration as the initial diagnostic test for suspected lymphoma involving the mediastinum, it consistently performs the poorest at definitively diagnosing HL for a variety of reasons, and therefore histology specimens are usually required. We present a case of HL presenting as isolated mediastinal adenopathy that was definitively diagnosed on EBUS using a 22 G coring needle in which cellular and histologic specimens were obtained, allowing the core biopsy to be fixed in formalin and treated as a surgical specimen. The patient started treatment soon after the procedure without requiring any further invasive tests. Although it seems intuitive that a coring EBUS needle would be advantageous in diseases such as HL, further studies are needed before definitive recommendations can be made.
- Open Access
- 1 January 2016
- Published by Touch Medical Media, Ltd. in touchREVIEWS in Respiratory & Pulmonary Diseases
- Vol. 01 (01)
Evaluation of a Steerable Tube Thoracostomy System Compatible with a Flexible Bronchoscope
Tube thoracostomy is effective at draining the pleural space; however, when fluid or air is loculated, drainage may be compromised. For this reason, a steerable chest tube with a redirecting stylet was developed. This tube also allows use of a flexible bronchoscope in the pleural space without significant limitations in mobility as seen in prior studies. Methods: We tested the ability of a steerable tube thoracostomy system in a porcine subject to change position, drain fluid, and utilize a flexible bronchoscope in the pleural space. Fiducial markers were implanted into the parietal pleura to demonstrate maneuverability of the bronchoscope and the ability to take forceps biopsies. Results: Bronchoscope positions in the pleural space were confirmed fluoroscopically: apical, medial, lateral, anterior diaphragm, and posterior diaphragm. All fiducial markers and tissue along the parietal pleura were located and biopsied via flexible forceps with the bronchoscope. The tube was repositioned into all dependent areas where fluid collected. Conclusions: This steerable tube and a flexible bronchoscope can access and visualize the pleural space, locate and biopsy implanted markers on the parietal pleural surface, and drain fluid from the pleural space. Further studies will be needed to evaluate the usefulness of this procedure in the clinical setting.
- 1 January 2016
- Published by Touch Medical Media, Ltd. in touchREVIEWS in Respiratory & Pulmonary Diseases
- Vol. 01 (01)
Open AccessEvaluation of a Steerable Tube Thoracostomy System Compatible with a Flexible Bronchoscope
Tube thoracostomy is effective at draining the pleural space; however, when fluid or air is loculated, drainage may be compromised. For this reason, a steerable chest tube with a redirecting stylet was developed. This tube also allows use of a flexible bronchoscope in the pleural space without significant limitations in mobility as seen in prior studies. Methods: We tested the ability of a steerable tube thoracostomy system in a porcine subject to change position, drain fluid, and utilize a flexible bronchoscope in the pleural space. Fiducial markers were implanted into the parietal pleura to demonstrate maneuverability of the bronchoscope and the ability to take forceps biopsies. Results: Bronchoscope positions in the pleural space were confirmed fluoroscopically: apical, medial, lateral, anterior diaphragm, and posterior diaphragm. All fiducial markers and tissue along the parietal pleura were located and biopsied via flexible forceps with the bronchoscope. The tube was repositioned into all dependent areas where fluid collected. Conclusions: This steerable tube and a flexible bronchoscope can access and visualize the pleural space, locate and biopsy implanted markers on the parietal pleural surface, and drain fluid from the pleural space. Further studies will be needed to evaluate the usefulness of this procedure in the clinical setting.