Jacoba van der Kooy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jacoba van der Kooy has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Eric. A. P. Steegers
Obstetrics and Gynecology, Erasmus MC Sophia Children's Hospital, University Medical Center Rotterdam, Rotterdam, Netherlands
4 shared publications - Erwin Birnie
Department of Obstetrics and Gynecology, Academic Collaborative Maternity Care, University Medical Center Utrecht, Utrecht, The Netherlands
3 shared publications - Johanna P. de Graaf
Department of Obstetrics and Gynaecology, Division of Obstetrics and Prenatal Medicine, Erasmus MC, University Medical Centre Rotterdam, Rotterdam, The Netherlands
3 shared publications - Semiha Denktaş
Division of Obstetrics & Prenatal Medicine, Department of Obstetrics and Gynaecology, Erasmus MC, PO Box 2040, 3000 CA, Rotterdam, The Netherlands
3 shared publications - Gouke J. Bonsel
Department of Orthopaedics and Sports Medicine, Erasmus MC, Rotterdam, The Netherlands.
2 shared publications - Nicole Valentine
Social Determinants of Health, World Health Organization (WHO), Geneva, Switzerland
2 shared publications
Latest Publications
- Open Access
- 31 July 2019
- Published by Springer Nature in Journal of Ovarian Research
- Vol. 12 (1) , 1-3
Effectiveness and safety of the PlasmaJet® Device in advanced stage ovarian carcinoma: a systematic review
About 80 % of all women affected by ovarian cancer present with advanced stage disease at the time of diagnosis. Achieving complete cytoreduction is complicated when many small tumor spots are found. Yet, complete cytoreduction is the most important determinant of survival. Application of a thermal plasma energy device to standard surgical instruments may help achieve complete cytoreduction. The ‘PlasmaJet® Device’ (Plasma Surgical, Inc., Roswell, GA, USA) is an electrically neutral device which emits a high–energy jet of argon plasma for direct tissue effects. We performed a literature review to investigate whether the use of the ‘PlasmaJet® Device’ in surgery of advanced stage ovarian carcinoma (FIGO IIIB-IV) is effective and safe. The primary outcome was the proportion of complete cytoreductions. The secondary outcomes were: complication rate, proportion of colostomies applied, histological findings, disease-free survival and overall survival. Five case series or reports were found, including a total of 77 patients with FIGO stage IIIC-IV ovarian cancer in whom the PlasmaJet® device was used for primary or interval debulking. Complete cytoreduction was obtained in 79% of the patients. Apart from one pneumothorax after extensive surgery, but no harm or additional complications related to the use of the PlasmaJet® Device were reported. Data on disease-free survival or overall survival were not reported. These findings suggest that the PlasmaJet® Device is an efficient and safe innovative surgical device for debulking surgery with encouraging results. We have proposed an RCT in which we will compare feasibility, safety and effectiveness aspects of the use of the PlasmaJet® versus conventional electrosurgery in advanced stage epithelial ovarian cancer (FIGO IIIB-IV).
- 31 July 2019
- Published by Springer Nature in Journal of Ovarian Research
- Vol. 12 (1) , 1-3
Open AccessEffectiveness and safety of the PlasmaJet® Device in advanced stage ovarian carcinoma: a systematic review
About 80 % of all women affected by ovarian cancer present with advanced stage disease at the time of diagnosis. Achieving complete cytoreduction is complicated when many small tumor spots are found. Yet, complete cytoreduction is the most important determinant of survival. Application of a thermal plasma energy device to standard surgical instruments may help achieve complete cytoreduction. The ‘PlasmaJet® Device’ (Plasma Surgical, Inc., Roswell, GA, USA) is an electrically neutral device which emits a high–energy jet of argon plasma for direct tissue effects. We performed a literature review to investigate whether the use of the ‘PlasmaJet® Device’ in surgery of advanced stage ovarian carcinoma (FIGO IIIB-IV) is effective and safe. The primary outcome was the proportion of complete cytoreductions. The secondary outcomes were: complication rate, proportion of colostomies applied, histological findings, disease-free survival and overall survival. Five case series or reports were found, including a total of 77 patients with FIGO stage IIIC-IV ovarian cancer in whom the PlasmaJet® device was used for primary or interval debulking. Complete cytoreduction was obtained in 79% of the patients. Apart from one pneumothorax after extensive surgery, but no harm or additional complications related to the use of the PlasmaJet® Device were reported. Data on disease-free survival or overall survival were not reported. These findings suggest that the PlasmaJet® Device is an efficient and safe innovative surgical device for debulking surgery with encouraging results. We have proposed an RCT in which we will compare feasibility, safety and effectiveness aspects of the use of the PlasmaJet® versus conventional electrosurgery in advanced stage epithelial ovarian cancer (FIGO IIIB-IV).
- Open Access
- 29 September 2017
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 17 (1) , 1-11
Quality of perinatal care services from the user’s perspective: a Dutch study applies the World Health Organization’s responsiveness concept
The concept of responsiveness was introduced by the World Health Organization (WHO) to address non-clinical aspects of service quality in an internationally comparable way. Responsiveness is defined as aspects of the way individuals are treated and the environment in which they are treated during health system interactions. The aim of this study is to assess responsiveness outcomes, their importance and factors influencing responsiveness outcomes during the antenatal and delivery phases of perinatal care. The Responsiveness in Perinatal and Obstetric Health Care Questionnaire was developed in 2009/10 based on the eight-domain WHO concept and the World Health Survey questionnaire. After ethical approval, a total of 171 women, who were 2 weeks postpartum, were recruited from three primary care midwifery practices in Rotterdam, the Netherlands, using face-to-face interviews. We dichotomized the original five ordinal response categories for responsiveness attainment as ‘poor’ and good responsiveness and analyzed the ranking of the domain performance and importance according to frequency scores. We used a series of independent variables related to health services and users’ personal background characteristics in multiple logistic regression analyses to explain responsiveness. Poor responsiveness outcomes ranged from 5.9% to 31.7% for the antenatal phase and from 9.7% to 27.1% for the delivery phase. Overall for both phases, ‘respect for persons’ (Autonomy, Dignity, Communication and Confidentiality) domains performed better and were judged to be more important than ‘client orientation’ domains (Choice and Continuity, Prompt Attention, Quality of Basic Amenities, Social Consideration). On the whole, responsiveness was explained more by health-care and health related issues than personal characteristics. To improve responsiveness outcomes caregivers should focus on domains in the category ‘client orientation’.
- 29 September 2017
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 17 (1) , 1-11
Open AccessQuality of perinatal care services from the user’s perspective: a Dutch study applies the World Health Organization’s responsiveness concept
The concept of responsiveness was introduced by the World Health Organization (WHO) to address non-clinical aspects of service quality in an internationally comparable way. Responsiveness is defined as aspects of the way individuals are treated and the environment in which they are treated during health system interactions. The aim of this study is to assess responsiveness outcomes, their importance and factors influencing responsiveness outcomes during the antenatal and delivery phases of perinatal care. The Responsiveness in Perinatal and Obstetric Health Care Questionnaire was developed in 2009/10 based on the eight-domain WHO concept and the World Health Survey questionnaire. After ethical approval, a total of 171 women, who were 2 weeks postpartum, were recruited from three primary care midwifery practices in Rotterdam, the Netherlands, using face-to-face interviews. We dichotomized the original five ordinal response categories for responsiveness attainment as ‘poor’ and good responsiveness and analyzed the ranking of the domain performance and importance according to frequency scores. We used a series of independent variables related to health services and users’ personal background characteristics in multiple logistic regression analyses to explain responsiveness. Poor responsiveness outcomes ranged from 5.9% to 31.7% for the antenatal phase and from 9.7% to 27.1% for the delivery phase. Overall for both phases, ‘respect for persons’ (Autonomy, Dignity, Communication and Confidentiality) domains performed better and were judged to be more important than ‘client orientation’ domains (Choice and Continuity, Prompt Attention, Quality of Basic Amenities, Social Consideration). On the whole, responsiveness was explained more by health-care and health related issues than personal characteristics. To improve responsiveness outcomes caregivers should focus on domains in the category ‘client orientation’.
- Open Access
- 8 June 2017
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 17 (1) , 1-11
Planned home compared with planned hospital births: mode of delivery and Perinatal mortality rates, an observational study
To compare the mode of delivery between planned home versus planned hospital births and to determine if differences in intervention rates could be interpreted as over- or undertreatment. Intervention and perinatal mortality rates were obtained for 679,952 low-risk women from the Dutch Perinatal Registry (2000–2007). Intervention was defined as operative vaginal delivery and/or caesarean section. Perinatal mortality was defined as the intrapartum and early neonatal mortality rate up to 7 days postpartum. Besides adjustment for maternal and care factors, we included for additional casemix adjustment: presence of congenital abnormality, small for gestational age, preterm birth, or low Apgar score. The techniques used were nested multiple stepwise logistic regression, and stratified analysis for separate risk groups. An intention-to-treat like analysis was performed. The intervention rate was lower in planned home compared to planned hospital births (10.9% 95% CI 10.8–11.0 vs. 13.8% 95% CI 13.6–13.9). Intended place of birth had significant impact on the likelihood to intervene after adjustment (planned homebirth (OR 0.77 95% CI. 0.75–0.78)). The mortality rate was lower in planned home births (0.15% vs. 0.18%). After adjustment, the interaction term home- intervention was significant (OR1.51 95% CI 1.25–1.84). In risk groups, a higher perinatal mortality rate was observed in planned home births. The potential presence of over- or under treatment as expressed by adjusted perinatal mortality differs per risk group. In planned home births especially multiparous women showed universally lower intervention rates. However, the benefit of substantially fewer interventions in the planned home group seems to be counterbalanced by substantially increased mortality if intervention occurs.
- 8 June 2017
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 17 (1) , 1-11
Open AccessPlanned home compared with planned hospital births: mode of delivery and Perinatal mortality rates, an observational study
To compare the mode of delivery between planned home versus planned hospital births and to determine if differences in intervention rates could be interpreted as over- or undertreatment. Intervention and perinatal mortality rates were obtained for 679,952 low-risk women from the Dutch Perinatal Registry (2000–2007). Intervention was defined as operative vaginal delivery and/or caesarean section. Perinatal mortality was defined as the intrapartum and early neonatal mortality rate up to 7 days postpartum. Besides adjustment for maternal and care factors, we included for additional casemix adjustment: presence of congenital abnormality, small for gestational age, preterm birth, or low Apgar score. The techniques used were nested multiple stepwise logistic regression, and stratified analysis for separate risk groups. An intention-to-treat like analysis was performed. The intervention rate was lower in planned home compared to planned hospital births (10.9% 95% CI 10.8–11.0 vs. 13.8% 95% CI 13.6–13.9). Intended place of birth had significant impact on the likelihood to intervene after adjustment (planned homebirth (OR 0.77 95% CI. 0.75–0.78)). The mortality rate was lower in planned home births (0.15% vs. 0.18%). After adjustment, the interaction term home- intervention was significant (OR1.51 95% CI 1.25–1.84). In risk groups, a higher perinatal mortality rate was observed in planned home births. The potential presence of over- or under treatment as expressed by adjusted perinatal mortality differs per risk group. In planned home births especially multiparous women showed universally lower intervention rates. However, the benefit of substantially fewer interventions in the planned home group seems to be counterbalanced by substantially increased mortality if intervention occurs.
- Open Access
- 18 June 2016
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 786
Different settings of place of midwife-led birth: evaluation of a midwife-led birth centre.
- 18 June 2016
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 786
Open AccessDifferent settings of place of midwife-led birth: evaluation of a midwife-led birth centre.
- Open Access
- 3 December 2014
- Published by Springer Nature in BMC Health Services Research
- Vol. 14 (1) , 622
Validity of a questionnaire measuring the world health organization concept of health system responsiveness with respect to perinatal services in the dutch obstetric care system
The concept of responsiveness, introduced by the World Health Organization (WHO), addresses non-clinical aspects of health service quality that are relevant regardless of provider, country, health system or health condition. Responsiveness refers to “aspects related to the way individuals are treated and the environment in which they are treated” during health system interactions. This paper assesses the psychometric properties of a newly developed responsiveness questionnaire dedicated to evaluating maternal experiences of perinatal care services, called the Responsiveness in Perinatal and Obstetric Health Care Questionnaire (ReproQ), using the eight-domain WHO concept. The ReproQ was developed between October 2009 and February 2010 by adapting the WHO Responsiveness Questionnaire items to the perinatal care context. The psychometric properties of feasibility, construct validity, and discriminative validity were empirically assessed in a sample of Dutch women two weeks post partum. A total of 171 women consented to participation. Feasibility: the interviews lasted between 20 and 40 minutes and the overall missing rate was 8%. Construct validity: mean Cronbach’s alphas for the antenatal, birth and postpartum phase were: 0.73 (range 0.57-0.82), 0.84 (range 0.66-0.92), and 0.87 (range 0.62-0.95) respectively. The item-own scale correlations within all phases were considerably higher than most of the item-other scale correlations. Within the antenatal care, birth care and post partum phases, the eight factors explained 69%, 69%, and 76% of variance respectively. Discriminative validity: overall responsiveness mean sum scores were higher for women whose children were not admitted. This confirmed the hypothesis that dissatisfaction with health outcomes is transferred to their judgement on responsiveness of the perinatal services. The ReproQ interview-based questionnaire demonstrated satisfactory psychometric properties to describe the quality of perinatal care in the Netherlands, with the potential to discriminate between different levels of quality of care. In view of the relatively small sample, further testing and research is recommended.
- 3 December 2014
- Published by Springer Nature in BMC Health Services Research
- Vol. 14 (1) , 622
Open AccessValidity of a questionnaire measuring the world health organization concept of health system responsiveness with respect to perinatal services in the dutch obstetric care system
The concept of responsiveness, introduced by the World Health Organization (WHO), addresses non-clinical aspects of health service quality that are relevant regardless of provider, country, health system or health condition. Responsiveness refers to “aspects related to the way individuals are treated and the environment in which they are treated” during health system interactions. This paper assesses the psychometric properties of a newly developed responsiveness questionnaire dedicated to evaluating maternal experiences of perinatal care services, called the Responsiveness in Perinatal and Obstetric Health Care Questionnaire (ReproQ), using the eight-domain WHO concept. The ReproQ was developed between October 2009 and February 2010 by adapting the WHO Responsiveness Questionnaire items to the perinatal care context. The psychometric properties of feasibility, construct validity, and discriminative validity were empirically assessed in a sample of Dutch women two weeks post partum. A total of 171 women consented to participation. Feasibility: the interviews lasted between 20 and 40 minutes and the overall missing rate was 8%. Construct validity: mean Cronbach’s alphas for the antenatal, birth and postpartum phase were: 0.73 (range 0.57-0.82), 0.84 (range 0.66-0.92), and 0.87 (range 0.62-0.95) respectively. The item-own scale correlations within all phases were considerably higher than most of the item-other scale correlations. Within the antenatal care, birth care and post partum phases, the eight factors explained 69%, 69%, and 76% of variance respectively. Discriminative validity: overall responsiveness mean sum scores were higher for women whose children were not admitted. This confirmed the hypothesis that dissatisfaction with health outcomes is transferred to their judgement on responsiveness of the perinatal services. The ReproQ interview-based questionnaire demonstrated satisfactory psychometric properties to describe the quality of perinatal care in the Netherlands, with the potential to discriminate between different levels of quality of care. In view of the relatively small sample, further testing and research is recommended.
- 7 March 2012
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 56 (7) , 920-925
A newly developed scavenging system for administration of nitrous oxide during labour: safe occupational use
Objective: Nitrous oxide (N2O) is routinely used as an analgesic in obstetrics during labour. Epidemiological studies have linked chronic occupational exposure to N2O to specific health problems, including reproductive risks. Occupational exposure limits (OELs) allow the use of N2O once appropriate preventive and safety measures have been taken. We assessed the effectiveness of a scavenger system (Anevac P‐system®, Medicvent Heinen & Löwestein Benelux, Barneveld, the Netherlands) applied in N2O administration during labour in a midwifery‐led birthing centre in the Netherlands.Methods: After informed consent, non‐pregnant midwives were trained to administer N2O. N2O was delivered as a 50 : 50 mixture with oxygen and was self administered by the patient. The scavenging device, containing a double mask and a chin mask, was connected to the local evacuation system vented outside the building. Data on the 8‐h time‐weighted average (8‐h TWA) as well as the 15‐min TWA (15‐min TWA) were obtained.Results: Thirteen patients were included. Six patients were included in the first study period. In this period the 8‐h TWA was not exceeded, however, in all patients, the 15‐min TWA occasionally exceeded the OELs. After four additional measures, seven patients were included. After implementation of these measures, the 8‐h TWA and 15‐min TWA never exceeded the OELs. System leakage was not observed during both study periods.Conclusion: The Anevac P‐scavenging system during N2O analgesia in labour prevents exceeding OELs in professional workers. The scavenging system appeared acceptable and effective, and can be considered in hospital settings that use N2O as analgesic during labour.
- 7 March 2012
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 56 (7) , 920-925
A newly developed scavenging system for administration of nitrous oxide during labour: safe occupational use
Objective: Nitrous oxide (N2O) is routinely used as an analgesic in obstetrics during labour. Epidemiological studies have linked chronic occupational exposure to N2O to specific health problems, including reproductive risks. Occupational exposure limits (OELs) allow the use of N2O once appropriate preventive and safety measures have been taken. We assessed the effectiveness of a scavenger system (Anevac P‐system®, Medicvent Heinen & Löwestein Benelux, Barneveld, the Netherlands) applied in N2O administration during labour in a midwifery‐led birthing centre in the Netherlands.Methods: After informed consent, non‐pregnant midwives were trained to administer N2O. N2O was delivered as a 50 : 50 mixture with oxygen and was self administered by the patient. The scavenging device, containing a double mask and a chin mask, was connected to the local evacuation system vented outside the building. Data on the 8‐h time‐weighted average (8‐h TWA) as well as the 15‐min TWA (15‐min TWA) were obtained.Results: Thirteen patients were included. Six patients were included in the first study period. In this period the 8‐h TWA was not exceeded, however, in all patients, the 15‐min TWA occasionally exceeded the OELs. After four additional measures, seven patients were included. After implementation of these measures, the 8‐h TWA and 15‐min TWA never exceeded the OELs. System leakage was not observed during both study periods.Conclusion: The Anevac P‐scavenging system during N2O analgesia in labour prevents exceeding OELs in professional workers. The scavenging system appeared acceptable and effective, and can be considered in hospital settings that use N2O as analgesic during labour.
- 1 November 2011
- Published by Wolters Kluwer Health in Obstetrics & Gynecology
- Vol. 118 (5) , 1037-1046
Planned Home Compared With Planned Hospital Births in The Netherlands
The purpose of our study was to compare the intrapartum and early neonatal mortality rate of planned home birth with planned hospital birth in community midwife-led deliveries after case mix adjustment. The perinatal outcome of 679,952 low-risk women was obtained from the Netherlands Perinatal Registry (2000-2007). This group represents all women who had a choice between home and hospital birth. Two different analyses were performed: natural prospective approach (intention-to-treat-like analysis) and perfect guideline approach (per-protocol-like analysis). Unadjusted and adjusted odds ratios (ORs) were calculated. Case mix was based on the presence of at least one of the following: congenital abnormalities, small for gestational age, preterm birth, or low Apgar score. We also investigated the potential risk role of intended place of birth. Multivariate stepwise logistic regression was used to investigate the potential risk role of intended place of birth. Intrapartum and neonatal death at 0-7 days was observed in 0.15% of planned home compared with 0.18% in planned hospital births (crude relative risk 0.80, 95% confidence interval [CI] 0.71-0.91). After case mix adjustment, the relation is reversed, showing nonsignificant increased mortality risk of home birth (OR 1.05, 95% CI 0.91-1.21). In certain subgroups, additional mortality may arise at home if risk conditions emerge at birth (up to 20% increase). Home birth, under routine conditions, is generally not associated with increased intrapartum and early neonatal death, yet in subgroups, additional risk cannot be excluded.
- 1 November 2011
- Published by Wolters Kluwer Health in Obstetrics & Gynecology
- Vol. 118 (5) , 1037-1046
Planned Home Compared With Planned Hospital Births in The Netherlands
The purpose of our study was to compare the intrapartum and early neonatal mortality rate of planned home birth with planned hospital birth in community midwife-led deliveries after case mix adjustment. The perinatal outcome of 679,952 low-risk women was obtained from the Netherlands Perinatal Registry (2000-2007). This group represents all women who had a choice between home and hospital birth. Two different analyses were performed: natural prospective approach (intention-to-treat-like analysis) and perfect guideline approach (per-protocol-like analysis). Unadjusted and adjusted odds ratios (ORs) were calculated. Case mix was based on the presence of at least one of the following: congenital abnormalities, small for gestational age, preterm birth, or low Apgar score. We also investigated the potential risk role of intended place of birth. Multivariate stepwise logistic regression was used to investigate the potential risk role of intended place of birth. Intrapartum and neonatal death at 0-7 days was observed in 0.15% of planned home compared with 0.18% in planned hospital births (crude relative risk 0.80, 95% confidence interval [CI] 0.71-0.91). After case mix adjustment, the relation is reversed, showing nonsignificant increased mortality risk of home birth (OR 1.05, 95% CI 0.91-1.21). In certain subgroups, additional mortality may arise at home if risk conditions emerge at birth (up to 20% increase). Home birth, under routine conditions, is generally not associated with increased intrapartum and early neonatal death, yet in subgroups, additional risk cannot be excluded.