Richard M. Kaufman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Richard M. Kaufman has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Claudia I. Chapuy
Dana-Farber Cancer Institute at St Elizabeth's Medical Center, Boston, Massachusetts
2 shared publicationsDarrell J. Triulzi
Department of Pathology Division of Transfusion Medicine University of Pittsburgh Pittsburgh Pennsylvania
2 shared publicationsMaria D. Aguad
Brigham and Women's Hospital, Boston, Massachusetts
2 shared publications- Mark K. Fung
University of Vermont Medical Center Burlington Vermont USA
2 shared publications Parul Doshi
Janssen Research & Development, Springhouse, Pennsylvania
2 shared publicationsRachel T. Nicholson
Massachusetts General Hospital, Boston, Massachusetts
2 shared publications
Latest Publications
- 7 September 2016
- Published by Wiley in Transfusion
- Vol. 56 (12) , 2964-2972
International validation of a dithiothreitol (DTT)‐based method to resolve the daratumumab interference with blood compatibility testing
BACKGROUND: Daratumumab (DARA) consistently interferes with routine blood bank serologic testing by directly binding to CD38 expressed on reagent red blood cells (RBCs). Treating RBCs with dithiothreitol (DTT) eliminates the DARA interference. We conducted an international, multicenter, blinded study aimed at validating the DTT method for use by blood bank laboratories worldwide.STUDY DESIGN AND METHODS: Paired plasma sample unknowns were sent to 25 participating blood bank laboratories. Sample 1 was spiked with DARA only (10 µg/mL), and Sample 2 with DARA plus a clinically significant RBC antibody (anti‐D [n = 6], anti‐Fya [n = 9], or anti‐s [n = 10]). Sites were instructed to perform an antibody screen with and without DTT‐treated RBCs and to use a DTT‐treated RBC panel for antibody identification. Qualitative data about the DTT method were collected by online survey. The primary outcome was the proportion of study sites able to identify the antibody unknown in the presence of DARA.RESULTS: All sites observed the DARA interference with the antibody screen. The DARA interference was seen with all testing methods (gel, tube, or solid phase). Using the DTT method, 25 of 25 sites (100%) successfully identified the antibody unknown in the presence of DARA. Feedback on the DTT method was positive, with 17 of 19 (90%) sites responding to the survey indicating that they planned to use the DTT method to test clinical samples from DARA‐treated patients.CONCLUSION: The DTT method is robust and reproducible and can be implemented by transfusion services worldwide to help provide safe blood products to patients treated with DARA.
- 7 September 2016
- Published by Wiley in Transfusion
- Vol. 56 (12) , 2964-2972
International validation of a dithiothreitol (DTT)‐based method to resolve the daratumumab interference with blood compatibility testing
BACKGROUND: Daratumumab (DARA) consistently interferes with routine blood bank serologic testing by directly binding to CD38 expressed on reagent red blood cells (RBCs). Treating RBCs with dithiothreitol (DTT) eliminates the DARA interference. We conducted an international, multicenter, blinded study aimed at validating the DTT method for use by blood bank laboratories worldwide.STUDY DESIGN AND METHODS: Paired plasma sample unknowns were sent to 25 participating blood bank laboratories. Sample 1 was spiked with DARA only (10 µg/mL), and Sample 2 with DARA plus a clinically significant RBC antibody (anti‐D [n = 6], anti‐Fya [n = 9], or anti‐s [n = 10]). Sites were instructed to perform an antibody screen with and without DTT‐treated RBCs and to use a DTT‐treated RBC panel for antibody identification. Qualitative data about the DTT method were collected by online survey. The primary outcome was the proportion of study sites able to identify the antibody unknown in the presence of DARA.RESULTS: All sites observed the DARA interference with the antibody screen. The DARA interference was seen with all testing methods (gel, tube, or solid phase). Using the DTT method, 25 of 25 sites (100%) successfully identified the antibody unknown in the presence of DARA. Feedback on the DTT method was positive, with 17 of 19 (90%) sites responding to the survey indicating that they planned to use the DTT method to test clinical samples from DARA‐treated patients.CONCLUSION: The DTT method is robust and reproducible and can be implemented by transfusion services worldwide to help provide safe blood products to patients treated with DARA.
- 18 February 2016
- Published by Elsevier in The Lancet Haematology
- Vol. 3 (3) , e105-6
A propensity to bleed.
- 18 February 2016
- Published by Elsevier in The Lancet Haematology
- Vol. 3 (3) , e105-6
A propensity to bleed.
- 1 February 2016
- Published by Wiley in Transfusion Medicine
- Vol. 26 (1) , 5-7
Platelet transfusions: where do we go from here?
- 1 February 2016
- Published by Wiley in Transfusion Medicine
- Vol. 26 (1) , 5-7
Platelet transfusions: where do we go from here?
- 14 July 2015
- Published by Wiley in Transfusion
- Vol. 55 (7) , 1822
In reply
- Open Access
- 12 March 2015
- Published by Wiley in Transfusion
- Vol. 55 (6pt2) , 1545-1554
Resolving the daratumumab interference with blood compatibility testing
BACKGROUND: Daratumumab (DARA), a promising novel therapy for multiple myeloma, is an IgG1κ monoclonal antibody that recognizes CD38 on myeloma cells. During routine compatibility testing, we observed that the plasma of five of five DARA‐treated patients demonstrated a positive antibody screen and panreactivity on red blood cell (RBC) panel testing. We hypothesized that the observed panreactivity reflected DARA binding to CD38 on reagent RBCs, and we investigated methods to prevent this binding.STUDY DESIGN AND METHODS: DARA binding to CD38+ or CD38– HL60 cells was assessed by flow cytometry. To remove cell surface CD38, cells were incubated with dithiothreitol (DTT) or trypsin. Soluble CD38 or anti‐DARA was used to neutralize DARA in solution. Routine blood bank serologic methods were used to test samples from DARA‐treated patients and normal plasma samples spiked with DARA and/or alloantibodies.RESULTS: Normal plasma samples spiked with DARA (0.1‐10 µg/mL) and incubated with reagent RBCs recapitulated the interference observed with samples from DARA‐treated patients. Flow cytometry experiments confirmed DARA binding to CD38+ HL60 cells, but not to CD38– controls. DTT treatment of CD38+ HL60 cells reduced DARA binding by 92% by denaturing cell surface CD38. Treating DARA‐containing plasma with soluble CD38 or anti‐DARA idiotype also inhibited DARA binding.CONCLUSION: DARA causes panreactivity in vitro by binding to CD38 on reagent RBCs. Treating reagent RBCs with DTT is a robust method to negate the DARA interference, enabling the safe provision of blood to DARA‐treated patients. Because DTT denatures Kell antigens, K– units are provided to these patients.
- 12 March 2015
- Published by Wiley in Transfusion
- Vol. 55 (6pt2) , 1545-1554
Open AccessResolving the daratumumab interference with blood compatibility testing
BACKGROUND: Daratumumab (DARA), a promising novel therapy for multiple myeloma, is an IgG1κ monoclonal antibody that recognizes CD38 on myeloma cells. During routine compatibility testing, we observed that the plasma of five of five DARA‐treated patients demonstrated a positive antibody screen and panreactivity on red blood cell (RBC) panel testing. We hypothesized that the observed panreactivity reflected DARA binding to CD38 on reagent RBCs, and we investigated methods to prevent this binding.STUDY DESIGN AND METHODS: DARA binding to CD38+ or CD38– HL60 cells was assessed by flow cytometry. To remove cell surface CD38, cells were incubated with dithiothreitol (DTT) or trypsin. Soluble CD38 or anti‐DARA was used to neutralize DARA in solution. Routine blood bank serologic methods were used to test samples from DARA‐treated patients and normal plasma samples spiked with DARA and/or alloantibodies.RESULTS: Normal plasma samples spiked with DARA (0.1‐10 µg/mL) and incubated with reagent RBCs recapitulated the interference observed with samples from DARA‐treated patients. Flow cytometry experiments confirmed DARA binding to CD38+ HL60 cells, but not to CD38– controls. DTT treatment of CD38+ HL60 cells reduced DARA binding by 92% by denaturing cell surface CD38. Treating DARA‐containing plasma with soluble CD38 or anti‐DARA idiotype also inhibited DARA binding.CONCLUSION: DARA causes panreactivity in vitro by binding to CD38 on reagent RBCs. Treating reagent RBCs with DTT is a robust method to negate the DARA interference, enabling the safe provision of blood to DARA‐treated patients. Because DTT denatures Kell antigens, K– units are provided to these patients.
- Top Cited Papers
- 3 February 2015
- Published by American College of Physicians in Annals of Internal Medicine
- Vol. 162 (3) , 205-213
Platelet Transfusion: A Clinical Practice Guideline From the AABB
The AABB (formerly, the American Association of Blood Banks) developed this guideline on appropriate use of platelet transfusion in adult patients. These guidelines are based on a systematic review of randomized, clinical trials and observational studies (1900 to September 2014) that reported clinical outcomes on patients receiving prophylactic or therapeutic platelet transfusions. An expert panel reviewed the data and developed recommendations using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework. The AABB recommends that platelets should be transfused prophylactically to reduce the risk for spontaneous bleeding in hospitalized adult patients with therapy-induced hypoproliferative thrombocytopenia. The AABB recommends transfusing hospitalized adult patients with a platelet count of 10 × 109 cells/L or less to reduce the risk for spontaneous bleeding. The AABB recommends transfusing up to a single apheresis unit or equivalent. Greater doses are not more effective, and lower doses equal to one half of a standard apheresis unit are equally effective. (Grade: strong recommendation; moderate-quality evidence) The AABB suggests prophylactic platelet transfusion for patients having elective central venous catheter placement with a platelet count less than 20 × 109 cells/L. (Grade: weak recommendation; low-quality evidence) The AABB suggests prophylactic platelet transfusion for patients having elective diagnostic lumbar puncture with a platelet count less than 50 × 109 cells/L. (Grade: weak recommendation; very-low-quality evidence) The AABB suggests prophylactic platelet transfusion for patients having major elective nonneuraxial surgery with a platelet count less than 50 × 109 cells/L. (Grade: weak recommendation; very-low-quality evidence) The AABB recommends against routine prophylactic platelet transfusion for patients who are nonthrombocytopenic and have cardiac surgery with cardiopulmonary bypass. The AABB suggests platelet transfusion for patients having bypass who exhibit perioperative bleeding with thrombocytopenia and/or evidence of platelet dysfunction. (Grade: weak recommendation; very-low-quality evidence) The AABB cannot recommend for or against platelet transfusion for patients receiving antiplatelet therapy who have intracranial hemorrhage (traumatic or spontaneous). (Grade: uncertain recommendation; very-low-quality evidence)
- 3 February 2015
- Published by American College of Physicians in Annals of Internal Medicine
- Vol. 162 (3) , 205-213
Top Cited PapersPlatelet Transfusion: A Clinical Practice Guideline From the AABB
The AABB (formerly, the American Association of Blood Banks) developed this guideline on appropriate use of platelet transfusion in adult patients. These guidelines are based on a systematic review of randomized, clinical trials and observational studies (1900 to September 2014) that reported clinical outcomes on patients receiving prophylactic or therapeutic platelet transfusions. An expert panel reviewed the data and developed recommendations using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework. The AABB recommends that platelets should be transfused prophylactically to reduce the risk for spontaneous bleeding in hospitalized adult patients with therapy-induced hypoproliferative thrombocytopenia. The AABB recommends transfusing hospitalized adult patients with a platelet count of 10 × 109 cells/L or less to reduce the risk for spontaneous bleeding. The AABB recommends transfusing up to a single apheresis unit or equivalent. Greater doses are not more effective, and lower doses equal to one half of a standard apheresis unit are equally effective. (Grade: strong recommendation; moderate-quality evidence) The AABB suggests prophylactic platelet transfusion for patients having elective central venous catheter placement with a platelet count less than 20 × 109 cells/L. (Grade: weak recommendation; low-quality evidence) The AABB suggests prophylactic platelet transfusion for patients having elective diagnostic lumbar puncture with a platelet count less than 50 × 109 cells/L. (Grade: weak recommendation; very-low-quality evidence) The AABB suggests prophylactic platelet transfusion for patients having major elective nonneuraxial surgery with a platelet count less than 50 × 109 cells/L. (Grade: weak recommendation; very-low-quality evidence) The AABB recommends against routine prophylactic platelet transfusion for patients who are nonthrombocytopenic and have cardiac surgery with cardiopulmonary bypass. The AABB suggests platelet transfusion for patients having bypass who exhibit perioperative bleeding with thrombocytopenia and/or evidence of platelet dysfunction. (Grade: weak recommendation; very-low-quality evidence) The AABB cannot recommend for or against platelet transfusion for patients receiving antiplatelet therapy who have intracranial hemorrhage (traumatic or spontaneous). (Grade: uncertain recommendation; very-low-quality evidence)
- 1 January 2015
- Published by Elsevier in Transfusion Medicine Reviews
- Vol. 29 (1) , 14-23
The Impact of Electronic Decision Support on Transfusion Practice: A Systematic Review
- 1 January 2015
- Published by Elsevier in Transfusion Medicine Reviews
- Vol. 29 (1) , 14-23
The Impact of Electronic Decision Support on Transfusion Practice: A Systematic Review
- 28 July 2014
- Published by Wiley in Transfusion
- Vol. 55 (1) , 144-153
Transfusion‐related adverse events in the Platelet Dose study
Background: How platelet (PLT) product characteristics such as dose, source (whole blood derived [WBD] vs. apheresis), storage duration, and ABO matching status affect the risks of transfusion‐related adverse events (TRAEs) is unclear. Similarly, more information is needed to define how recipient characteristics affect the frequency of TRAEs after PLT transfusion.Study Design and Methods: In the multicenter Platelet Dose (“PLADO”) study, pediatric and adult hematology‐oncology patients with hypoproliferative thrombocytopenia were randomized to receive low‐dose (LD), medium‐dose (MD), or high‐dose (HD) PLT prophylaxis for a pretransfusion PLT count of not more than 10 × 109/L. All PLT units (apheresis or WBD) were leukoreduced. Post hoc analyses of PLADO data were performed using multipredictor models.Results: A total of 5034 PLT transfusions to 1102 patients were analyzed. A TRAE occurred with 501 PLT transfusions (10.0%). The most common TRAEs were fever (6.6% of transfusions), allergic or hypersensitivity reactions (1.9%), and sinus tachycardia (1.8%). Patients assigned HD PLTs were more likely than LD or MD patients to experience any TRAE (odds ratio for HD vs. MD, 1.50; 95% confidence interval, 1.10‐2.05; three‐group comparison p = 0.02). PLT source and ABO matching status were not significantly related to overall TRAE risk. Compared to a patient's first PLT transfusion, subsequent PLT transfusions were less likely to have a TRAE reported, primarily due to a lower risk of allergic or hypersensitivity reactions.Conclusion: The most important PLT unit characteristic associated with TRAEs was PLT dose per transfusion. HD PLTs may increase the risk of TRAEs, and LD PLTs may reduce the risk.
- 28 July 2014
- Published by Wiley in Transfusion
- Vol. 55 (1) , 144-153
Transfusion‐related adverse events in the Platelet Dose study
Background: How platelet (PLT) product characteristics such as dose, source (whole blood derived [WBD] vs. apheresis), storage duration, and ABO matching status affect the risks of transfusion‐related adverse events (TRAEs) is unclear. Similarly, more information is needed to define how recipient characteristics affect the frequency of TRAEs after PLT transfusion.Study Design and Methods: In the multicenter Platelet Dose (“PLADO”) study, pediatric and adult hematology‐oncology patients with hypoproliferative thrombocytopenia were randomized to receive low‐dose (LD), medium‐dose (MD), or high‐dose (HD) PLT prophylaxis for a pretransfusion PLT count of not more than 10 × 109/L. All PLT units (apheresis or WBD) were leukoreduced. Post hoc analyses of PLADO data were performed using multipredictor models.Results: A total of 5034 PLT transfusions to 1102 patients were analyzed. A TRAE occurred with 501 PLT transfusions (10.0%). The most common TRAEs were fever (6.6% of transfusions), allergic or hypersensitivity reactions (1.9%), and sinus tachycardia (1.8%). Patients assigned HD PLTs were more likely than LD or MD patients to experience any TRAE (odds ratio for HD vs. MD, 1.50; 95% confidence interval, 1.10‐2.05; three‐group comparison p = 0.02). PLT source and ABO matching status were not significantly related to overall TRAE risk. Compared to a patient's first PLT transfusion, subsequent PLT transfusions were less likely to have a TRAE reported, primarily due to a lower risk of allergic or hypersensitivity reactions.Conclusion: The most important PLT unit characteristic associated with TRAEs was PLT dose per transfusion. HD PLTs may increase the risk of TRAEs, and LD PLTs may reduce the risk.
- 14 July 2014
- Published by Wiley in Transfusion
- Vol. 54 (7) , 1704
Staphylococcus aureus sepsis from one cocomponent of a “triple” apheresis platelet donation
- 14 July 2014
- Published by Wiley in Transfusion
- Vol. 54 (7) , 1704
Staphylococcus aureus sepsis from one cocomponent of a “triple” apheresis platelet donation
- 17 December 2012
- Published by Wiley in Transfusion
- Vol. 53 (9) , 2069-2077
Does Rh immune globulin suppress HLA sensitization in pregnancy?
Background How Rh immune globulin (RhIG) prevents sensitization to D antigen is unclear. If RhIG Fc delivers a nonspecific immunosuppressive signal, then RhIG may inhibit sensitization to antigens other than D. HLA antibody prevalence was compared in previously pregnant D– versus D+ women to investigate whether RhIG suppresses HLA sensitization. Study Design and Methods In the Leukocyte Antibody Prevalence Study (LAPS), 7920 volunteer blood donors were screened for anti‐HLA and surveyed about prior pregnancies and transfusions. A secondary analysis of the LAPS database was performed. Results D– women not more than 40 years old (presumed to have received antenatal with or without postpartum RhIG in all pregnancies) had a significantly lower HLA sensitization rate than D+ women (relative risk, 0.58; 95% confidence interval [CI], 0.40‐0.83). When stratified by deliveries (one, two, three, or four or more), D– women not older than 40 were HLA sensitized less often than D+ women in every case. In contrast, a clear relationship between D type and HLA sensitization was not seen in older previously pregnant women whose childbearing years are presumed to have preceded the use of routine RhIG prophylaxis. In a multivariable logistic regression model, D– women not more than 40 years old remained significantly less likely to be HLA sensitized compared with D+ women after adjusting for parity, time from last pregnancy, lost pregnancies, and transfusions (odds ratio [OR], 0.55; 95% CI, 0.34‐0.88). Conclusion Consistent with a nonspecific immunosuppressive effect of RhIG, younger previously pregnant D– women were less likely than previously pregnant D+ women to be HLA sensitized.
- 17 December 2012
- Published by Wiley in Transfusion
- Vol. 53 (9) , 2069-2077
Does Rh immune globulin suppress HLA sensitization in pregnancy?
Background How Rh immune globulin (RhIG) prevents sensitization to D antigen is unclear. If RhIG Fc delivers a nonspecific immunosuppressive signal, then RhIG may inhibit sensitization to antigens other than D. HLA antibody prevalence was compared in previously pregnant D– versus D+ women to investigate whether RhIG suppresses HLA sensitization. Study Design and Methods In the Leukocyte Antibody Prevalence Study (LAPS), 7920 volunteer blood donors were screened for anti‐HLA and surveyed about prior pregnancies and transfusions. A secondary analysis of the LAPS database was performed. Results D– women not more than 40 years old (presumed to have received antenatal with or without postpartum RhIG in all pregnancies) had a significantly lower HLA sensitization rate than D+ women (relative risk, 0.58; 95% confidence interval [CI], 0.40‐0.83). When stratified by deliveries (one, two, three, or four or more), D– women not older than 40 were HLA sensitized less often than D+ women in every case. In contrast, a clear relationship between D type and HLA sensitization was not seen in older previously pregnant women whose childbearing years are presumed to have preceded the use of routine RhIG prophylaxis. In a multivariable logistic regression model, D– women not more than 40 years old remained significantly less likely to be HLA sensitized compared with D+ women after adjusting for parity, time from last pregnancy, lost pregnancies, and transfusions (odds ratio [OR], 0.55; 95% CI, 0.34‐0.88). Conclusion Consistent with a nonspecific immunosuppressive effect of RhIG, younger previously pregnant D– women were less likely than previously pregnant D+ women to be HLA sensitized.