Raj Das
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Raj Das has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Anna-Maria Belli
St George’s Hospital
3 shared publications Anna-Maria Belli
St George’s Healthcare NHS Trust, Blackshaw
2 shared publications- Haofan Wang
St George’s Hospital
1 shared publication Ioannis Vlahos
St George’s Healthcare NHS Trust, Blackshaw
1 shared publicationIssac Manyonda
St George’s Healthcare NHS Trust
1 shared publication- Jane Daniels
Nottingham Clinical Trials Unit, University of Nottingham, Nottingham, UK
1 shared publication
Latest Publications
- 1 August 2015
- Published by Oxford University Press (OUP)
- p. 179-186
Postpartum haemorrhage: what is the role of occlusion balloons?
Post-partum haemorrhage remains a significant cause of maternal morbidity and mortality in childbirth, and interventional radiology now has a crucial role in improving patient outcomes and survival. The prevalence of abnormal placentation is increasing, and with improved ultrasound and MRI detection an increasing number of cases at high risk of post-partum haemorrhage from placenta accreta and percreta are being identified that can benefit from the ’electiveʼ use of prophylactic internal iliac artery occlusion balloons. Prophylactic occlusion balloons in high-risk pregnancies can reduce haemorrhage and promote uterine-conserving surgical techniques. We discuss the technique of occlusion balloon placement, indications, potential complications, and evidence base.
- 1 August 2015
- Published by Oxford University Press (OUP)
- p. 179-186
Postpartum haemorrhage: what is the role of occlusion balloons?
Post-partum haemorrhage remains a significant cause of maternal morbidity and mortality in childbirth, and interventional radiology now has a crucial role in improving patient outcomes and survival. The prevalence of abnormal placentation is increasing, and with improved ultrasound and MRI detection an increasing number of cases at high risk of post-partum haemorrhage from placenta accreta and percreta are being identified that can benefit from the ’electiveʼ use of prophylactic internal iliac artery occlusion balloons. Prophylactic occlusion balloons in high-risk pregnancies can reduce haemorrhage and promote uterine-conserving surgical techniques. We discuss the technique of occlusion balloon placement, indications, potential complications, and evidence base.
- 19 December 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (4) , 871-877
Identifying the Learning Curve for Uterine Artery Embolisation in an Interventional Radiological Training Unit
A clear understanding of operator experience is important in improving technical success whilst minimising patient risk undergoing endovascular procedures, and there is the need to ensure that trainees have the appropriate skills as primary operators. The aim of the study is to retrospectively analyse uterine artery embolisation (UAE) procedures performed by interventional radiology (IR) trainees at an IR training unit analysing fluoroscopy times and radiation dose as surrogate markers of technical skill. Ten IR fellows were primary operator in 200 UAE procedures over a 5-year period. We compared fluoroscopy times, radiation dose and complications, after having them categorised according to three groups: Group 1, initial five, Group 2, >5 procedures and Group 3, penultimate five UAE procedures. We documented factors that may affect screening time (number of vials employed and use of microcatheters). Mean fluoroscopy time was 18.4 (±8.1), 17.3 (±9.0), 16.3 (±8.4) min in Groups 1, 2 and 3, respectively. There was no statistically significant difference between these groups (p > 0.05) with respect to fluoroscopy time or radiation dose. Analysis after correction for confounding factors showed no statistical significance (p > 0.05). All procedures were technically successful, and total complication rate was 4 %. UAE was chosen as a highly standardised procedure followed by IR practitioners. Although there is a non-significant trend for shorter screening times with experience, technical success and safety were not compromised with appropriate Consultant supervision, which illustrates a safe construct for IR training. This is important and reassuring information for patients undergoing a procedure in a training unit.
- 19 December 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (4) , 871-877
Identifying the Learning Curve for Uterine Artery Embolisation in an Interventional Radiological Training Unit
A clear understanding of operator experience is important in improving technical success whilst minimising patient risk undergoing endovascular procedures, and there is the need to ensure that trainees have the appropriate skills as primary operators. The aim of the study is to retrospectively analyse uterine artery embolisation (UAE) procedures performed by interventional radiology (IR) trainees at an IR training unit analysing fluoroscopy times and radiation dose as surrogate markers of technical skill. Ten IR fellows were primary operator in 200 UAE procedures over a 5-year period. We compared fluoroscopy times, radiation dose and complications, after having them categorised according to three groups: Group 1, initial five, Group 2, >5 procedures and Group 3, penultimate five UAE procedures. We documented factors that may affect screening time (number of vials employed and use of microcatheters). Mean fluoroscopy time was 18.4 (±8.1), 17.3 (±9.0), 16.3 (±8.4) min in Groups 1, 2 and 3, respectively. There was no statistically significant difference between these groups (p > 0.05) with respect to fluoroscopy time or radiation dose. Analysis after correction for confounding factors showed no statistical significance (p > 0.05). All procedures were technically successful, and total complication rate was 4 %. UAE was chosen as a highly standardised procedure followed by IR practitioners. Although there is a non-significant trend for shorter screening times with experience, technical success and safety were not compromised with appropriate Consultant supervision, which illustrates a safe construct for IR training. This is important and reassuring information for patients undergoing a procedure in a training unit.
- 3 December 2013
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 37 (5) , 1179-1190
Comparison of Embolic Agents Used in Uterine Artery Embolisation: A Systematic Review and Meta-Analysis
This study was designed to undertake systematic review and meta-analysis of published comparative trials comparing embolic agents used in uterine artery embolisation (UAE) for uterine leiomyomata. Systematic literature searches were performed in MEDLINE, Embase, PubMed, and Cochrane Central databases from database inception to July 2012. Randomised and nonrandomised trials comparing two or more embolic agents used in UAE were included. Assessment included five widely used embolic agents: nonspherical polyvinyl alcohol (PVA) (Contour PVA, Boston Scientific or PVA Cook Medical); spherical PVA (Contour SE, Boston Scientific); acrylamido PVA (Beadblock, Biocompatibles, Terumo); tris-acryl gelatin microspheres (TAGM) (Embospheres, Merit Medical Inc); and polyzene-F hydrogel microspheres (Embozenes, CeloNova Biosciences). Outcomes assessed included: quality of life (QOL), assessment, magnetic resonance imaging (MRI), uterine and fibroid volumes and degrees of MRI fibroid enhancement and devascularisation. A total of 262 citations were reviewed with 5 randomised, controlled trials involving 295 women and 5 non-RCTs involving 617 women included. No evidence of superiority of any embolic agent was demonstrated. Meta-analysis was performed between TAGM (Embospheres) and spherical PVA microspheres. Two RCTs found a trend toward greater uterine and dominant fibroid volume reductions with Embospheres but the combined differences were not statistically significant (p = 0.78 and p = 0.94 respectively). Embospheres demonstrated greater percentage fibroid devascularisation than spherical PVA (p = 0.039). This study confirms that the current evidence demonstrates superiority of Embospheres over spherical PVA but no reported differences in outcomes between any of the other agents. Comparison of embolic agents was limited by lack of RCT data and further research is warranted.
- 3 December 2013
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 37 (5) , 1179-1190
Comparison of Embolic Agents Used in Uterine Artery Embolisation: A Systematic Review and Meta-Analysis
This study was designed to undertake systematic review and meta-analysis of published comparative trials comparing embolic agents used in uterine artery embolisation (UAE) for uterine leiomyomata. Systematic literature searches were performed in MEDLINE, Embase, PubMed, and Cochrane Central databases from database inception to July 2012. Randomised and nonrandomised trials comparing two or more embolic agents used in UAE were included. Assessment included five widely used embolic agents: nonspherical polyvinyl alcohol (PVA) (Contour PVA, Boston Scientific or PVA Cook Medical); spherical PVA (Contour SE, Boston Scientific); acrylamido PVA (Beadblock, Biocompatibles, Terumo); tris-acryl gelatin microspheres (TAGM) (Embospheres, Merit Medical Inc); and polyzene-F hydrogel microspheres (Embozenes, CeloNova Biosciences). Outcomes assessed included: quality of life (QOL), assessment, magnetic resonance imaging (MRI), uterine and fibroid volumes and degrees of MRI fibroid enhancement and devascularisation. A total of 262 citations were reviewed with 5 randomised, controlled trials involving 295 women and 5 non-RCTs involving 617 women included. No evidence of superiority of any embolic agent was demonstrated. Meta-analysis was performed between TAGM (Embospheres) and spherical PVA microspheres. Two RCTs found a trend toward greater uterine and dominant fibroid volume reductions with Embospheres but the combined differences were not statistically significant (p = 0.78 and p = 0.94 respectively). Embospheres demonstrated greater percentage fibroid devascularisation than spherical PVA (p = 0.039). This study confirms that the current evidence demonstrates superiority of Embospheres over spherical PVA but no reported differences in outcomes between any of the other agents. Comparison of embolic agents was limited by lack of RCT data and further research is warranted.
- 6 February 2013
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 36 (5) , 1280-1287
MRI Assessment of Uterine Artery Patency and Fibroid Infarction Rates 6 Months after Uterine Artery Embolization with Nonspherical Polyvinyl Alcohol
We have observed significant rates of uterine artery patency after uterine artery embolization (UAE) with nonspherical polyvinyl alcohol (nsPVA) on 6 month follow-up MR scanning. The study aim was to quantitatively assess uterine artery patency after UAE with nsPVA and to assess the effect of continued uterine artery patency on outcomes. A single centre, retrospective study of 50 patients undergoing bilateral UAE for uterine leiomyomata was undertaken. Pelvic MRI was performed before and 6 months after UAE. All embolizations were performed with nsPVA. Outcome measures included uterine artery patency, uterine and dominant fibroid volume, dominant fibroid percentage infarction, presence of ovarian arterial collaterals, and symptom scores assessed by the Uterine Fibroid Symptom and Quality of Life questionnaire (UFS-QOL). Magnetic resonance angiographic evidence of uterine artery recanalization was demonstrated in 90 % of the patients (64 % bilateral, 26 % unilateral) at 6 months. Eighty percent of all dominant fibroids demonstrated >90 % infarction. The mean percentage reduction in dominant fibroid volume was 35 %. No significant difference was identified between nonpatent, unilateral, and bilateral recanalization of the uterine arteries with regard to percentage dominant fibroid infarction or dominant fibroid volume reduction. The presence of bilaterally or unilaterally patent uterine arteries was not associated with inferior clinical outcomes (symptom score or UFS-QOL scores) at 6 months. The high rates of uterine artery patency challenge the current paradigm that nsPVA is a permanent embolic agent and that permanent uterine artery occlusion is necessary to optimally treat uterine fibroids. Despite high rates of uterine artery recanalization in this cohort, satisfactory fibroid infarction rates and UFS-QOL scores were achieved.
- 6 February 2013
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 36 (5) , 1280-1287
MRI Assessment of Uterine Artery Patency and Fibroid Infarction Rates 6 Months after Uterine Artery Embolization with Nonspherical Polyvinyl Alcohol
We have observed significant rates of uterine artery patency after uterine artery embolization (UAE) with nonspherical polyvinyl alcohol (nsPVA) on 6 month follow-up MR scanning. The study aim was to quantitatively assess uterine artery patency after UAE with nsPVA and to assess the effect of continued uterine artery patency on outcomes. A single centre, retrospective study of 50 patients undergoing bilateral UAE for uterine leiomyomata was undertaken. Pelvic MRI was performed before and 6 months after UAE. All embolizations were performed with nsPVA. Outcome measures included uterine artery patency, uterine and dominant fibroid volume, dominant fibroid percentage infarction, presence of ovarian arterial collaterals, and symptom scores assessed by the Uterine Fibroid Symptom and Quality of Life questionnaire (UFS-QOL). Magnetic resonance angiographic evidence of uterine artery recanalization was demonstrated in 90 % of the patients (64 % bilateral, 26 % unilateral) at 6 months. Eighty percent of all dominant fibroids demonstrated >90 % infarction. The mean percentage reduction in dominant fibroid volume was 35 %. No significant difference was identified between nonpatent, unilateral, and bilateral recanalization of the uterine arteries with regard to percentage dominant fibroid infarction or dominant fibroid volume reduction. The presence of bilaterally or unilaterally patent uterine arteries was not associated with inferior clinical outcomes (symptom score or UFS-QOL scores) at 6 months. The high rates of uterine artery patency challenge the current paradigm that nsPVA is a permanent embolic agent and that permanent uterine artery occlusion is necessary to optimally treat uterine fibroids. Despite high rates of uterine artery recanalization in this cohort, satisfactory fibroid infarction rates and UFS-QOL scores were achieved.
- 29 October 2010
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (4) , 723-738
Arterial Closure Devices Versus Manual Compression for Femoral Haemostasis in Interventional Radiological Procedures: A Systematic Review and Meta-Analysis
The use of arterial closure devices (ACDs) in interventional radiology (IR) procedures has not yet been validated by large-scale randomised controlled trials or meta-analysis. Improved haemostasis and early mobilisation are publicised advantages; however, anecdotal evidence of haemorrhagic and ischaemic complications with ACDs is also apparent. Meta-analysis from interventional cardiology cannot be directly extrapolated for IR patients.
- 29 October 2010
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (4) , 723-738
Arterial Closure Devices Versus Manual Compression for Femoral Haemostasis in Interventional Radiological Procedures: A Systematic Review and Meta-Analysis
The use of arterial closure devices (ACDs) in interventional radiology (IR) procedures has not yet been validated by large-scale randomised controlled trials or meta-analysis. Improved haemostasis and early mobilisation are publicised advantages; however, anecdotal evidence of haemorrhagic and ischaemic complications with ACDs is also apparent. Meta-analysis from interventional cardiology cannot be directly extrapolated for IR patients.