Yongmin Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yongmin Kim has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
Ravi Managuli
Univ. of Washington (United States)
6 shared publications- Kirk W. Beach
University of Washington
5 shared publications - Siddhartha Sikdar
Department of Bioengineering, George Mason University, Fairfax, VA 22030, USA
5 shared publications - Kerem Karadayi
Univ. of Washington (United States)
4 shared publications David R. Haynor
Image Computing Systems Laboratory, Departments of Electrical Engineering, Bioengineering, and Radiology, University of Washington, Seattle, WA 98195-2500
3 shared publicationsHyun Wook Park
Univ. of Washington (South Korea)
3 shared publications
Latest Publications
- 1 April 2012
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 198 (4) , 896-901
Interobserver Agreement and Intraobserver Reproducibility in Thyroid Ultrasound Elastography
OBJECTIVE. The objective of this study was to evaluate interobserver agreement and intraobserver reproducibility in thyroid ultrasound elastography. SUBJECTS AND METHODS. Fifty-six patients (56 nodules) were enrolled for this prospective study between December 2010 and March 2011. All patients were scheduled for thyroid surgery because their nodules had been found by fine-needle aspiration biopsies to be malignant, suspicious for malignancy, or follicular/Hürthle cell neoplasm. On each patient, three endocrinologists performed ultrasound elastography examinations using a commercial ultrasound machine. No external compression with the transducer was applied because pulsation from the carotid artery was used. Each endocrinologist repeated an elastography examination on the same thyroid nodule. An elasticity contrast index, which quantifies the local strain contrast within a nodule, was interactively determined after a nodule’s boundary was delineated by the endocrinologist. A large elasticity contrast index...
- 1 April 2012
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 198 (4) , 896-901
Interobserver Agreement and Intraobserver Reproducibility in Thyroid Ultrasound Elastography
OBJECTIVE. The objective of this study was to evaluate interobserver agreement and intraobserver reproducibility in thyroid ultrasound elastography. SUBJECTS AND METHODS. Fifty-six patients (56 nodules) were enrolled for this prospective study between December 2010 and March 2011. All patients were scheduled for thyroid surgery because their nodules had been found by fine-needle aspiration biopsies to be malignant, suspicious for malignancy, or follicular/Hürthle cell neoplasm. On each patient, three endocrinologists performed ultrasound elastography examinations using a commercial ultrasound machine. No external compression with the transducer was applied because pulsation from the carotid artery was used. Each endocrinologist repeated an elastography examination on the same thyroid nodule. An elasticity contrast index, which quantifies the local strain contrast within a nodule, was interactively determined after a nodule’s boundary was delineated by the endocrinologist. A large elasticity contrast index...
- 1 June 2011
- Published by The Endocrine Society
- p. P1-704
Interobserver and Intraobserver Agreement of Thyroid Ultrasound Elastography Using In Vivo Compression
- 1 June 2011
- Published by The Endocrine Society
- p. P1-704
Interobserver and Intraobserver Agreement of Thyroid Ultrasound Elastography Using In Vivo Compression
- 1 May 2011
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 37 (5) , 679-687
Transthoracic Coronary Doppler Vibrometry in the Evaluation of Normal Volunteers and Patients With Coronary Artery Stenosis
- 1 May 2011
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 37 (5) , 679-687
Transthoracic Coronary Doppler Vibrometry in the Evaluation of Normal Volunteers and Patients With Coronary Artery Stenosis
- 1 February 2011
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 1 (1) , 3-4
Message from the advisory editor of ‘Biomedical Engineering Letters’
- 1 February 2011
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 1 (1) , 3-4
Message from the advisory editor of ‘Biomedical Engineering Letters’
- 31 March 2010
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 36 (3) , 480-487
New Adaptive Clutter Rejection for Ultrasound Color Doppler Imaging: In vivo Study
- 31 March 2010
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 36 (3) , 480-487
New Adaptive Clutter Rejection for Ultrasound Color Doppler Imaging: In vivo Study
- 4 March 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7629, 762903
Reconstruction error in 3D ultrasound imaging with mechanical probes
Three-dimensional (3D) ultrasound data are acquired mostly using a dedicated mechanical probe that houses a 1D array transducer. This 1D transducer swivels back and forth continuously in the elevation direction (continuous scanning) for fast acquisition. When 3D ultrasound data are acquired via continuous scanning but the continuous motion of a transducer is not taken into account during reconstruction, the reconstructed volume contains error. In this study, we systematically analyzed this error, which is a complex function of many parameters. The error increases when the transducer angular speed (ω) increases. Also, it varies depending on the voxel location inside an acquired volume. The mean error is calculated by averaging the errors at all acquired voxel locations. With a 60-degree volume angle, a 60-degree sector angle, 12-cm scan depth and 48 transmit beams per slice, the mean error is 5.3 mm when ω is 0.6 degrees/ms. When ω is reduced to 0.1 degrees/ms, the mean error decreases to 0.81 mm. We also assessed the impact of this error on the reconstructed images of a 3D phantom using simulation. At high angular speeds, the error in reconstructed images becomes noticeable and results in missing parts, geometric distortion and lowered image quality.
- 4 March 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7629, 762903
Reconstruction error in 3D ultrasound imaging with mechanical probes
Three-dimensional (3D) ultrasound data are acquired mostly using a dedicated mechanical probe that houses a 1D array transducer. This 1D transducer swivels back and forth continuously in the elevation direction (continuous scanning) for fast acquisition. When 3D ultrasound data are acquired via continuous scanning but the continuous motion of a transducer is not taken into account during reconstruction, the reconstructed volume contains error. In this study, we systematically analyzed this error, which is a complex function of many parameters. The error increases when the transducer angular speed (ω) increases. Also, it varies depending on the voxel location inside an acquired volume. The mean error is calculated by averaging the errors at all acquired voxel locations. With a 60-degree volume angle, a 60-degree sector angle, 12-cm scan depth and 48 transmit beams per slice, the mean error is 5.3 mm when ω is 0.6 degrees/ms. When ω is reduced to 0.1 degrees/ms, the mean error decreases to 0.81 mm. We also assessed the impact of this error on the reconstructed images of a 3D phantom using simulation. At high angular speeds, the error in reconstructed images becomes noticeable and results in missing parts, geometric distortion and lowered image quality.
- Open Access
- 27 October 2009
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 11 (4) , e44
Challenges to Using an Electronic Personal Health Record by a Low-Income Elderly Population
Challenges to Using an Electronic Personal Health Record by a Low-income Elderly Population
- 27 October 2009
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 11 (4) , e44
Open AccessChallenges to Using an Electronic Personal Health Record by a Low-Income Elderly Population
Challenges to Using an Electronic Personal Health Record by a Low-income Elderly Population
- 30 September 2009
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 20 (9) , 1157-1163
Doppler Vibrometry: Assessment of Arterial Stenosis by Using Perivascular Tissue Vibrations without Lumen Visualization
- 30 September 2009
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 20 (9) , 1157-1163
Doppler Vibrometry: Assessment of Arterial Stenosis by Using Perivascular Tissue Vibrations without Lumen Visualization
- 1 September 2008
- Published by Elsevier in Ultrasonics
- Vol. 48 (5) , 384-393
Adaptive field-of-view imaging for efficient receive beamforming in medical ultrasound imaging systems
- 1 September 2008
- Published by Elsevier in Ultrasonics
- Vol. 48 (5) , 384-393
Adaptive field-of-view imaging for efficient receive beamforming in medical ultrasound imaging systems
- 1 July 2008
- Published by Elsevier in Ultrasonics
- Vol. 48 (3) , 159-168
Research interface on a programmable ultrasound scanner
- 1 July 2008
- Published by Elsevier in Ultrasonics
- Vol. 48 (3) , 159-168
Research interface on a programmable ultrasound scanner