Toshiaki Hattori
Toshiaki Hattori has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Ryo Kato
Cooperative Research Facility Center, Toyohashi University of Technology
6 shared publicationsKazuaki Sawada
Department of Electrical and Electronic Information Engineering
3 shared publications- Kazuaki Sawada
Department of Electrical and Electronic Information Engineering, Toyohashi University of Technology, Toyohashi, Aichi 441-8580, Japan
3 shared publications Daichi Miyamoto
Department of Materials Science, Toyohashi University of Technology, Toyohashi, Aichi 441‐8580, Japan
1 shared publication- Fumihiro Dasai
Department of Electrical and Electronic Information Engineering, Toyohashi University of Technology, Hibarigaoka 1-1, Tenpaku, Toyohashi 441-8580, Japan
1 shared publication Fumiya Nakamura
Department of Electrical and Electronic Information Engineering, Toyohashi University of Technology, 1-1 Hibarigaoka, Tenpaku, Toyohashi, Aichi 441-8580 , Japan
1 shared publication
Latest Publications
- 5 April 2021
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 70 (4.5) , 283-288
Evaluation of Ca2+ Adsorption Property for a Single Grain of Strongly Acidic Cation-exchange Resin Using a Ca2+ Image Sensor and Its Simulation with Concentration Diffusion
Ion exchange resins are widely used to product pure water and in the purification and measurement of substances in various fields. The physical and chemical properties of resins are generally evaluated by a batch method and/or a column method using a lot of resins. In this study, however, the dynamic behavior of ion-exchanging Ca2+ for a single grain of strongly acidic cation-exchange resin was evaluated using a multi-pixels array type Ca+ image sensor and a micromanipulator. It was found that the Ca2+ adsorption occurred in two steps. The dynamic behavior was also simulated by Matlab with a forward difference method based on the experimental model. By comparing the practical measurement and the simulation, the Ca2+ adsorption behavior by ion-exchange resin was fully characterized. This method using an ion-image sensor and the Matlab simulation is very useful to evaluate the dynamic properties of sub-millimeter particles.
- 5 April 2021
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 70 (4.5) , 283-288
Evaluation of Ca2+ Adsorption Property for a Single Grain of Strongly Acidic Cation-exchange Resin Using a Ca2+ Image Sensor and Its Simulation with Concentration Diffusion
Ion exchange resins are widely used to product pure water and in the purification and measurement of substances in various fields. The physical and chemical properties of resins are generally evaluated by a batch method and/or a column method using a lot of resins. In this study, however, the dynamic behavior of ion-exchanging Ca2+ for a single grain of strongly acidic cation-exchange resin was evaluated using a multi-pixels array type Ca+ image sensor and a micromanipulator. It was found that the Ca2+ adsorption occurred in two steps. The dynamic behavior was also simulated by Matlab with a forward difference method based on the experimental model. By comparing the practical measurement and the simulation, the Ca2+ adsorption behavior by ion-exchange resin was fully characterized. This method using an ion-image sensor and the Matlab simulation is very useful to evaluate the dynamic properties of sub-millimeter particles.
- 14 March 2020
- Published by Oxford University Press (OUP) in Bulletin of the Chemical Society of Japan
- Vol. 93 (5) , 655-662
Characterization of Calcium Ion Release from a Polymer-Coated Electrode with a Plasticized PVC Membrane Containing Calcium Salts, and Its Contraction Examination of Vorticella Convallaria
Up to now several bio-imaging methods have taken a very good pictures and/or recordings. With the bio-imaging growing, a micro-stimulation method to limit in a fine region is required. A conventional chemical stimulation method is hard to response its requirement, however, an electrochemical device is potential to response the issue. This paper reports on the fabrication and the use of an electrochemical Ca2+-releasing device. The device consists of a three-layer electrode, including two transducers, a PVC membrane, PEDOT layer, and gold or carbon. The dynamic behavior of Ca2+ released from the device is evaluated by a two-dimensional 16K pixels array Ca2+ image sensor, and is simulated using a diffusion model of Ca2+. Both experimental and calculated time and distance dependent profiles are almost agreed when the PVC membrane is thin. As its biological application, a permeabilized Vorticella convallaria was set at a distance of ca. 0.1 mm from the Ca2+-releasing device. There was no response for some time just after the switching-on, and then it gradually contracted. The gradual contraction after the interval proved that the Ca2+-releasing device can be used a soft insertion based on the concentration diffusion.
- 14 March 2020
- Published by Oxford University Press (OUP) in Bulletin of the Chemical Society of Japan
- Vol. 93 (5) , 655-662
Characterization of Calcium Ion Release from a Polymer-Coated Electrode with a Plasticized PVC Membrane Containing Calcium Salts, and Its Contraction Examination of Vorticella Convallaria
Up to now several bio-imaging methods have taken a very good pictures and/or recordings. With the bio-imaging growing, a micro-stimulation method to limit in a fine region is required. A conventional chemical stimulation method is hard to response its requirement, however, an electrochemical device is potential to response the issue. This paper reports on the fabrication and the use of an electrochemical Ca2+-releasing device. The device consists of a three-layer electrode, including two transducers, a PVC membrane, PEDOT layer, and gold or carbon. The dynamic behavior of Ca2+ released from the device is evaluated by a two-dimensional 16K pixels array Ca2+ image sensor, and is simulated using a diffusion model of Ca2+. Both experimental and calculated time and distance dependent profiles are almost agreed when the PVC membrane is thin. As its biological application, a permeabilized Vorticella convallaria was set at a distance of ca. 0.1 mm from the Ca2+-releasing device. There was no response for some time just after the switching-on, and then it gradually contracted. The gradual contraction after the interval proved that the Ca2+-releasing device can be used a soft insertion based on the concentration diffusion.
- Open Access
CCD Multi-Ion Image Sensor with Four 128 × 128 Pixels Array
A semiconductor array pH image sensor consisting of four separated blocks was fabricated using charged coupled device (CCD) and complementary metal oxide semiconductor (CMOS) technologies. The sensing surface of one of the four blocks was Si3N4 and this block responded to H+. The surfaces of the other three blocks were respectively covered with cation sensitive membranes, which were separately printed with plasticized poly (vinyl chloride) solutions including Na+, K+, and Ca2+ ionophores by using an ink-jet printing method. In addition, each block of the image sensor with 128 × 128 pixels could have a calibration curve generated in each independent measurement condition. The present sensor could measure the concentration image of four kinds of ions (H+, K+, Na +, Ca2+) simultaneously at 8.3 frames per second (fps) in separated regions on a chip.
Open AccessCCD Multi-Ion Image Sensor with Four 128 × 128 Pixels Array
A semiconductor array pH image sensor consisting of four separated blocks was fabricated using charged coupled device (CCD) and complementary metal oxide semiconductor (CMOS) technologies. The sensing surface of one of the four blocks was Si3N4 and this block responded to H+. The surfaces of the other three blocks were respectively covered with cation sensitive membranes, which were separately printed with plasticized poly (vinyl chloride) solutions including Na+, K+, and Ca2+ ionophores by using an ink-jet printing method. In addition, each block of the image sensor with 128 × 128 pixels could have a calibration curve generated in each independent measurement condition. The present sensor could measure the concentration image of four kinds of ions (H+, K+, Na +, Ca2+) simultaneously at 8.3 frames per second (fps) in separated regions on a chip.
- Open Access
- 1 January 2016
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 65 (11) , 637-644
Fabrication and Evaluation of Calcium Ion Releasing Electrochemical Device Using a Ternary Complex
- 1 January 2016
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 65 (11) , 637-644
Open AccessFabrication and Evaluation of Calcium Ion Releasing Electrochemical Device Using a Ternary Complex
- 11 January 2013
- Published by Springer Nature
- Vol. 984, 61-66
Separation of Chitooligosaccharides in Acidic Solution by Capillary Electrophoresis
Capillary electrophoresis (CE) of chitooligosaccharides (COS) in aqueous solution is effective for their separation from other saccharides. However, COS easily adsorb on negatively charged surfaces, such as fused silica capillaries in acidic solutions. Conventional photometric detection cannot be applied directly because saccharides do not absorb ultraviolet or visible light. Here, we describe a simple CE of COS in an acidic solution using a positively charged capillary coated with N-trimethoxypropyl-N,N,N-trimethylammonium chloride and indirect photometric detection with crystal violet nitrate background solution.
- 11 January 2013
- Published by Springer Nature
- Vol. 984, 61-66
Separation of Chitooligosaccharides in Acidic Solution by Capillary Electrophoresis
Capillary electrophoresis (CE) of chitooligosaccharides (COS) in aqueous solution is effective for their separation from other saccharides. However, COS easily adsorb on negatively charged surfaces, such as fused silica capillaries in acidic solutions. Conventional photometric detection cannot be applied directly because saccharides do not absorb ultraviolet or visible light. Here, we describe a simple CE of COS in an acidic solution using a positively charged capillary coated with N-trimethoxypropyl-N,N,N-trimethylammonium chloride and indirect photometric detection with crystal violet nitrate background solution.
- 13 December 2011
- Published by Wiley in Electroanalysis
- Vol. 24 (1) , 114-120
CCD‐Type Sodium Ion Image Sensor: Dynamic Observation of Ion‐Exchange Reactions of a Single Na‐Type Cation‐Exchange Resin Bead
- 13 December 2011
- Published by Wiley in Electroanalysis
- Vol. 24 (1) , 114-120
CCD‐Type Sodium Ion Image Sensor: Dynamic Observation of Ion‐Exchange Reactions of a Single Na‐Type Cation‐Exchange Resin Bead
- Open Access
- 10 October 2010
- Published by Springer Nature in Analytical Sciences
- Vol. 26 (10) , 1039-1045
Real-Time Two-Dimensional Imaging of Potassium Ion Distribution Using an Ion Semiconductor Sensor with Charged Coupled Device Technology
Two-dimensional real-time observation of potassium ion distributions was achieved using an ion imaging device based on charge-coupled device (CCD) and metal-oxide semiconductor technologies, and an ion selective membrane. The CCD potassium ion image sensor was equipped with an array of 32 × 32 pixels (1024 pixels). It could record five frames per second with an area of 4.16 × 4.16 mm2. Potassium ion images were produced instantly. The leaching of potassium ion from a 3.3 M KCl Ag/AgCl reference electrode was dynamically monitored in aqueous solution. The potassium ion selective membrane on the semiconductor consisted of plasticized poly(vinyl chloride) (PVC) with bis(benzo-15-crown-5). The addition of a polyhedral oligomeric silsesquioxane to the plasticized PVC membrane greatly improved adhesion of the membrane onto Si3N4 of the semiconductor surface, and the potential response was stabilized. The potential response was linear from 10−2 to 10−5 M logarithmic concentration of potassium ion. The selectivity coefficients were KK+,Li+pot = 10−2.85, KK+,Na+pot = 10−2.30, KK+,Rb+pot =10−1.16, and KK+,Cs+pot = 10−2.05.
- 10 October 2010
- Published by Springer Nature in Analytical Sciences
- Vol. 26 (10) , 1039-1045
Open AccessReal-Time Two-Dimensional Imaging of Potassium Ion Distribution Using an Ion Semiconductor Sensor with Charged Coupled Device Technology
Two-dimensional real-time observation of potassium ion distributions was achieved using an ion imaging device based on charge-coupled device (CCD) and metal-oxide semiconductor technologies, and an ion selective membrane. The CCD potassium ion image sensor was equipped with an array of 32 × 32 pixels (1024 pixels). It could record five frames per second with an area of 4.16 × 4.16 mm2. Potassium ion images were produced instantly. The leaching of potassium ion from a 3.3 M KCl Ag/AgCl reference electrode was dynamically monitored in aqueous solution. The potassium ion selective membrane on the semiconductor consisted of plasticized poly(vinyl chloride) (PVC) with bis(benzo-15-crown-5). The addition of a polyhedral oligomeric silsesquioxane to the plasticized PVC membrane greatly improved adhesion of the membrane onto Si3N4 of the semiconductor surface, and the potential response was stabilized. The potential response was linear from 10−2 to 10−5 M logarithmic concentration of potassium ion. The selectivity coefficients were KK+,Li+pot = 10−2.85, KK+,Na+pot = 10−2.30, KK+,Rb+pot =10−1.16, and KK+,Cs+pot = 10−2.05.