Jacques Cazaux
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jacques Cazaux has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
K. Sato
1 shared publicationN. Kuwano
1 shared publication
Latest Publications
- 1 December 2013
- Published by Elsevier in Ultramicroscopy
- Vol. 135, 43-49
Backscattered electron imaging at low emerging angles: A physical approach to contrast in LVSEM
- 1 December 2013
- Published by Elsevier in Ultramicroscopy
- Vol. 135, 43-49
Backscattered electron imaging at low emerging angles: A physical approach to contrast in LVSEM
- 7 August 2012
- Published by Oxford University Press (OUP) in Journal of Electron Microscopy
- Vol. 61 (5) , 261-284
From the physics of secondary electron emission to image contrasts in scanning electron microscopy
Image formation in scanning electron microscopy (SEM) is a combination of physical processes, electron emissions from the sample, and of a technical process related to the detection of a fraction of these electrons. For the present survey of image contrasts in SEM, simplified considerations in the physics of the secondary electron emission yield, δ, are combined with the effects of a partial collection of the emitted secondary electrons. Although some consideration is initially given to the architecture of modern SEM, the main attention is devoted to the material contrasts with the respective roles of the sub-surface and surface compositions of the sample, as well as with the roles of the field effects in the vacuum gap. The recent trends of energy filtering in normal SEM and the reduction of the incident energy to a few electron volts in very low-energy electron microscopy are also considered. For an understanding by the SEM community, the mathematical expressions are explained with simple physical arguments.
- 7 August 2012
- Published by Oxford University Press (OUP) in Journal of Electron Microscopy
- Vol. 61 (5) , 261-284
From the physics of secondary electron emission to image contrasts in scanning electron microscopy
Image formation in scanning electron microscopy (SEM) is a combination of physical processes, electron emissions from the sample, and of a technical process related to the detection of a fraction of these electrons. For the present survey of image contrasts in SEM, simplified considerations in the physics of the secondary electron emission yield, δ, are combined with the effects of a partial collection of the emitted secondary electrons. Although some consideration is initially given to the architecture of modern SEM, the main attention is devoted to the material contrasts with the respective roles of the sub-surface and surface compositions of the sample, as well as with the roles of the field effects in the vacuum gap. The recent trends of energy filtering in normal SEM and the reduction of the incident energy to a few electron volts in very low-energy electron microscopy are also considered. For an understanding by the SEM community, the mathematical expressions are explained with simple physical arguments.
- 15 March 2012
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 111 (6) , 064903
Reflectivity of very low energy electrons (< 10 eV) from solid surfaces: Physical and instrumental aspects
The impact of very low energy electrons (VLEE) on solid surfaces plays an important role in various fields of modern technology. Plasma physics, space research and particle-accelerators and progress in these fields are based partly on investigation of VLEE emission and reflection properties as obtained from laboratory measurements. Here the influence of the material composition and of the angle of incidence on the reflectivity, R, of VLEE is derived by the use of simple quantum mechanical arguments showing a rapid decrease of R from 100% when the incident energy of electrons increases from 0 eV while the surface sensitivity increases. The measurements depend significantly on the potential referencing between the electron source, the sample, and the detector, as well as of the energy spread of the incident electrons. VLEE thin film transmission is briefly considered and various practical consequences of the contrasts (crystalline, topographic, doping) as reported in scanning low energy electron microscopy (SLEEM) are discussed. The present developments may be transposed easily to any kind of solid sample and the possibility of imaging the local vacuum level (or work function) change with a minimum of radiation damage is suggested.
- 15 March 2012
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 111 (6) , 064903
Reflectivity of very low energy electrons (< 10 eV) from solid surfaces: Physical and instrumental aspects
The impact of very low energy electrons (VLEE) on solid surfaces plays an important role in various fields of modern technology. Plasma physics, space research and particle-accelerators and progress in these fields are based partly on investigation of VLEE emission and reflection properties as obtained from laboratory measurements. Here the influence of the material composition and of the angle of incidence on the reflectivity, R, of VLEE is derived by the use of simple quantum mechanical arguments showing a rapid decrease of R from 100% when the incident energy of electrons increases from 0 eV while the surface sensitivity increases. The measurements depend significantly on the potential referencing between the electron source, the sample, and the detector, as well as of the energy spread of the incident electrons. VLEE thin film transmission is briefly considered and various practical consequences of the contrasts (crystalline, topographic, doping) as reported in scanning low energy electron microscopy (SLEEM) are discussed. The present developments may be transposed easily to any kind of solid sample and the possibility of imaging the local vacuum level (or work function) change with a minimum of radiation damage is suggested.
- 1 February 2010
- Published by Elsevier in Ultramicroscopy
- Vol. 110 (3) , 242-253
Material contrast in SEM: Fermi energy and work function effects
- 1 February 2010
- Published by Elsevier in Ultramicroscopy
- Vol. 110 (3) , 242-253
Material contrast in SEM: Fermi energy and work function effects
- 1 November 2008
- Published by Elsevier in Ultramicroscopy
- Vol. 108 (12) , 1645-1652
On some contrast reversals in SEM: Application to metal/insulator systems
- 1 November 2008
- Published by Elsevier in Ultramicroscopy
- Vol. 108 (12) , 1645-1652
On some contrast reversals in SEM: Application to metal/insulator systems
- 31 January 2008
- Published by Elsevier in Journal of Electron Spectroscopy and Related Phenomena
- Vol. 162 (1) , 36-43
About the secondary electron emission from solid hydrogens: H2, HD, D2 and T2
- 31 January 2008
- Published by Elsevier in Journal of Electron Spectroscopy and Related Phenomena
- Vol. 162 (1) , 36-43
About the secondary electron emission from solid hydrogens: H2, HD, D2 and T2
- 30 November 2007
- Published by Elsevier in Journal of Electrostatics
- Vol. 65 (12) , 764-774
Critical thicknesses of electrostatic powder coatings from inside
- 30 November 2007
- Published by Elsevier in Journal of Electrostatics
- Vol. 65 (12) , 764-774
Critical thicknesses of electrostatic powder coatings from inside
- 12 January 2005
- Published by Wiley in Journal of Microscopy
- Vol. 217 (1) , 16-35
Recent developments and new strategies in scanning electron microscopy*
Summary: In addition to improvements in lateral resolution in scanning electron microscopy, recent developments of interest here concern extension of the incident beam energy, E0, over two decades, from ≈ 20 keV to ≈ 0.1–0.5 keV and the possibility of changing the take‐off emission, α, of detected secondary electrons. These two degrees of freedom for image acquisition permit a series of images of the same field of view of a specimen to be obtained, each image of the series differing from the others in some aspect. The origins of these differences are explored in detail and they are tentatively interpreted in terms of the change in the secondary electron emission yield δ vs. E0, δ = f(E0), and also of the change in δ vs. α, ∂δ/∂α. Various origins for the chemical contrast and topographic contrast have been identified. Illustrated by correlating a secondary electron image and a backscattered electron image, use of the scatter diagram technique facilitates image comparison. The difference between the lateral resolution and the size of the minimum detectable detail is outlined to avoid possible errors in nanometrology. Some aspects related to charging are also considered and possible causes of contrast reversal are suggested. Finally, the suggested strategy consists of the acquisition of various images of a given specimen by changing one parameter: primary beam energy and take‐off angle for conductive specimens; working distance or beam intensity for high‐resolution experiments; scanning frequency for insulating specimens.
- 12 January 2005
- Published by Wiley in Journal of Microscopy
- Vol. 217 (1) , 16-35
Recent developments and new strategies in scanning electron microscopy*
Summary: In addition to improvements in lateral resolution in scanning electron microscopy, recent developments of interest here concern extension of the incident beam energy, E0, over two decades, from ≈ 20 keV to ≈ 0.1–0.5 keV and the possibility of changing the take‐off emission, α, of detected secondary electrons. These two degrees of freedom for image acquisition permit a series of images of the same field of view of a specimen to be obtained, each image of the series differing from the others in some aspect. The origins of these differences are explored in detail and they are tentatively interpreted in terms of the change in the secondary electron emission yield δ vs. E0, δ = f(E0), and also of the change in δ vs. α, ∂δ/∂α. Various origins for the chemical contrast and topographic contrast have been identified. Illustrated by correlating a secondary electron image and a backscattered electron image, use of the scatter diagram technique facilitates image comparison. The difference between the lateral resolution and the size of the minimum detectable detail is outlined to avoid possible errors in nanometrology. Some aspects related to charging are also considered and possible causes of contrast reversal are suggested. Finally, the suggested strategy consists of the acquisition of various images of a given specimen by changing one parameter: primary beam energy and take‐off angle for conductive specimens; working distance or beam intensity for high‐resolution experiments; scanning frequency for insulating specimens.
- 1 August 2004
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 10 (6) , 670-684
About the Mechanisms of Charging in EPMA, SEM, and ESEM with Their Time Evolution
The physical mechanisms involved in electron irradiation of insulating specimens are investigated by combining some simple considerations of solid-state physics (trapping mechanisms of electrons and secondary electron emission) with basic equations of electrostatics. To facilitate the understanding of the involved mechanisms only widely irradiated samples having a uniform distribution of trapping sites are considered. This starting hypothesis allows development of simple models for the trapped charge distributions in ground-coated specimens as investigated in electron probe microanalysis (EPMA) as well as for the bare specimens investigated in scanning electron microscopy (SEM) and environmental SEM (ESEM). Governed by self-regulation processes, the evolution of the electric parameters during the irradiation are also considered for the first time and practical consequences in EPMA, SEM, and ESEM are deduced. In particular, the widespread idea that the noncharging condition of SEM is obtained at a critical energyE2(where δ + η = 1 with δ and η yields obtained in noncharging experiments) is critically discussed.
- 1 August 2004
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 10 (6) , 670-684
About the Mechanisms of Charging in EPMA, SEM, and ESEM with Their Time Evolution
The physical mechanisms involved in electron irradiation of insulating specimens are investigated by combining some simple considerations of solid-state physics (trapping mechanisms of electrons and secondary electron emission) with basic equations of electrostatics. To facilitate the understanding of the involved mechanisms only widely irradiated samples having a uniform distribution of trapping sites are considered. This starting hypothesis allows development of simple models for the trapped charge distributions in ground-coated specimens as investigated in electron probe microanalysis (EPMA) as well as for the bare specimens investigated in scanning electron microscopy (SEM) and environmental SEM (ESEM). Governed by self-regulation processes, the evolution of the electric parameters during the irradiation are also considered for the first time and practical consequences in EPMA, SEM, and ESEM are deduced. In particular, the widespread idea that the noncharging condition of SEM is obtained at a critical energyE2(where δ + η = 1 with δ and η yields obtained in noncharging experiments) is critically discussed.
Charging in scanning electron microscopy “from inside and outside”
This paper is an attempt to analyse most of the complicated mechanisms involved in charging and discharging of insulators investigated by scanning electron microscopy (SEM). Fundamental concepts on the secondary electron emission (SEE) yield from insulators combined with electrostatics arguments permit to reconsider, first, the widespread opinion following which charging is minimized when the incident beam energy E0 is chosen to be equal to the critical energy E°2, where the nominal total yield δ°+η°=1. For bare insulators submitted to a defocused irradiation, it is suggested here that the critical energy under permanent irradiation EC2 corresponds to a range of primary electrons, R, and nearly equals the maximum escape depth of the secondary electrons, r. This suggestion is supported by a comparison between published data of the SEE yield δ° of insulators (short pulse experiments) and experimental results obtained from a permanent irradiation for EC2. New SEE effects are also predicted at the early beginning of irradiation when finely focused probes are used. Practical considerations are also developed, with specific attention given to the role of a contamination layer where a negative charging may occur at any beam energy. The role of the various time constants involved in charging and discharging is also investigated, with special attention given to the dielectric time constant, which explains the dose rate‐dependent effects on the effective landing energy in the steady state. Numerical applications permit to give orders of magnitude of various effects, and several other practical consequences are deduced and illustrated. Some new mechanisms for the contrast reversal during irradiation or with the change of the primary electron (PE) energy are also suggested.
Charging in scanning electron microscopy “from inside and outside”
This paper is an attempt to analyse most of the complicated mechanisms involved in charging and discharging of insulators investigated by scanning electron microscopy (SEM). Fundamental concepts on the secondary electron emission (SEE) yield from insulators combined with electrostatics arguments permit to reconsider, first, the widespread opinion following which charging is minimized when the incident beam energy E0 is chosen to be equal to the critical energy E°2, where the nominal total yield δ°+η°=1. For bare insulators submitted to a defocused irradiation, it is suggested here that the critical energy under permanent irradiation EC2 corresponds to a range of primary electrons, R, and nearly equals the maximum escape depth of the secondary electrons, r. This suggestion is supported by a comparison between published data of the SEE yield δ° of insulators (short pulse experiments) and experimental results obtained from a permanent irradiation for EC2. New SEE effects are also predicted at the early beginning of irradiation when finely focused probes are used. Practical considerations are also developed, with specific attention given to the role of a contamination layer where a negative charging may occur at any beam energy. The role of the various time constants involved in charging and discharging is also investigated, with special attention given to the dielectric time constant, which explains the dose rate‐dependent effects on the effective landing energy in the steady state. Numerical applications permit to give orders of magnitude of various effects, and several other practical consequences are deduced and illustrated. Some new mechanisms for the contrast reversal during irradiation or with the change of the primary electron (PE) energy are also suggested.