    Light intensity distribution in images from rigid endoscopes used in minimal access sinus surgery

    by Eric W. Abel, Nikolaos Fotiadis, Paul S. White

    Objectives/Hypothesis: To investigate the pattern of intensity levels in images generated by the two most commonly used rigid endoscopes angulations in sinus surgery: 0° and 30°.Methods: An enclosed light box containing an optical square grid, under endoscope illumination set just below saturation level, was used for measuring light distribution levels across test images. Endoscopes with 0° and 30° angulations were tested at 10 mm from the grid, typical for sinus surgery. The grid was set perpendicular to the axis of the shaft of the endoscope. The grayscale light intensity (GLI) levels (0 = black, 255 = white) in each of the grid squares were quantified from the digitized images.Results: Light intensity was highly non‐uniform for both endoscopes. The brightest area of the field of view was at the center for the 0° endoscope and at about 20% of the image diameter proximally from the center for the 30° endoscope. For the 0° endoscope with a maximum value of about 230 GLI (90% of white saturation) at the center the minimum value was about 100 GLI at the periphery. The 30° endoscope with a similar maximum GLI value of 226 had a minimum of under 50 GLI at the most distant periphery, too dark for clear grid line definition.Conclusion: There are wide variations in light intensity across the image circle and much reduced illumination of the field edge. Surgeons should be aware of this fact so that accommodation can be made when surgical manipulation is performed away from the center of the endoscope field. This is especially relevant in angled cavities such as the frontal sinus recess, where the degree of angulation necessitates “edge of field” surgery.


  • Defining optical distortion in rigid endoscopes

    by Eric Abel, Nikolaos Fotiadis, Mohammed Miah, Paul White

    Objectives/Hypothesis To describe lens and perspective distortion using new measures that have practical meaning to the surgeon, and to apply these measures to show the extent of optical distortion in rigid endoscopes used in endoscopic sinus surgery. Study Design Laboratory measurements on rigid endoscopes. Methods Barrel and perspective distortion were measured in 4-mm diameter 0°, 30°, 45°, and 70° rigid sinus endoscopes. Images of square grids were obtained with the endoscopes aligned in a specially constructed test rig. The terms relative size (RS) and relative distance (RD) were introduced to describe size and distance errors; and the term relative angle (RA) was used for assessing perspective errors. Results All the endoscopes exhibited similar barrel distortion. RS of the image at the periphery was 52%; RD was 80%. For RA values of 30°, 45°, and 70°, RS values were 77%, 58%, and 32%, respectively. Objects at the edge of the surgical field appear significantly more distant than suggested by their screen position. Perspective distortion occurs, unless RA = 0°. Barrel distortion of the lens helped to offset the effects of perspective distortion. Conclusion Optical distortion can be quantified and understood using straightforward definitions. High levels of distortion are common, particularly due to perspective distortion, which is dependent on RA but independent of barrel distortion and the viewing angle of the endoscope. Level of Evidence N/A. Laryngoscope, 125:561–566, 2015


  • Automatic glare removal in endoscopic imaging

    by Eric W. Abel, Yuan Zhuo, Peter D. Ross, Paul S. White

    Glare from surgical instruments and tissue surfaces often occurs during endoscopic procedures and can be disturbing to the operator. The brightness level of the light source can be reduced, but at the expense of overall image clarity, so alternative solutions are needed for removing glare. Digital image-processing methods offer the opportunity to lessen or eliminate glare by reducing the intensity of the affected parts of the image. This study investigated a new automated method for glare reduction that uses two different intensity thresholds as a basis for applying glare reduction processes and it also reduces unpleasant artifacts at the glare region boundaries. The new glare-reduction method was compared with a previous method. Three variants of each method, each with different color biases in the glare regions, were applied to a 20-s surgical recording containing substantial amounts of glare. The six versions and the original recording were evaluated subjectively by a group of 10 experienced surgeons using a paired-comparisons method, in which each version was compared for preference with all the other versions. The new double-threshold intensity-subtraction method scored significantly higher than the previously developed glare-reduction method (p < 0.05). It also scored higher than the original (unprocessed) version, but not significantly. The color bias was important, with combinations of pink and grey performing better than yellow tints. The findings show the new method to be a significant improvement in automatic glare reduction compared with earlier methods. The method is not computationally demanding, so it can in the future be evaluated clinically in high-definition endoscopic imaging systems and developed further in this environment.


  • Open Access

    Doped diamond-like carbon coatings for surgical instruments reduce protein and prion-amyloid biofouling and improve subsequent cleaning

    by T.J. Secker, R. Hervé, Q. Zhao, K.B. Borisenko, E.W. Abel, C.W. Keevil

    Doped diamond-like carbon (DLC) coatings offer potential antifouling surfaces against microbial and protein attachment. In particular, stainless steel surgical instruments are subject to tissue protein and resilient prion protein attachment, making decontamination methods used in sterile service departments ineffective, potentially increasing the risk of iatrogenic Creutzfeldt-Jakob disease during surgical procedures. This study examined the adsorption of proteins and prion-associated amyloid to doped DLC surfaces and the efficacy of commercial cleaning chemistries applied to these spiked surfaces, compared to titanium nitride coating and stainless steel. Surfaces inoculated with ME7-infected brain homogenate were visualised using SYPRO Ruby/Thioflavin T staining and modified epi-fluorescence microscopy before and after cleaning. Reduced protein and prion amyloid contamination was observed on the modified surfaces and subsequent decontamination efficacy improved. This highlights the potential for a new generation of coatings for surgical instruments to reduce the risk of iatrogenic CJD infection.


  • Methods for removing glare in digital endoscope images

    by Eric Abel, Wei Xi, Paul White

    Images produced by rod-lens telescopes used in minimally invasive surgery are brightest in the central region and darker at the periphery. To enable a clear view of the darker regions of the image, the intensity of light from the source usually is set to a high level. This often causes substantial reflection and glare from surgical tools and some tissue surfaces, which can be disturbing for the surgeon. This study investigated digital image processing methods in an attempt to reduce glare without introducing other adverse qualities into the images. Two methods of reducing glare in local high-brightness regions of the image were evaluated. The first method reduced intensity by a fixed amount while also optionally introducing a slight color. The second method combined a proportion of the original intensity value with a proportion of a lower intensity value, again with an optional color bias. Two surgical video clips were modified with each of 13 different glare-reduction variants using these methods. These and the original sequence were played to a group of 10 experienced surgeons for subjective assessment. The pixel-based methods both showed statistically significant improvements over the original version. The incorporation of a slight yellow bias was preferred to a straightforward gray-level reduction. The simple approach of using a lower level of brightness alone was found to be unacceptable. Both new methods work in real time at normal video speeds. Antiglare methods have been found that reduce the perception of glare and are otherwise unobtrusive. This encourages further work to refine the preferred methods and to test them with a larger group over a wider range of video sequences. Clinical trials then will follow.


  • Adhesion of protein residues to substituted (111) diamond surfaces: An insight from density functional theory and classical molecular dynamics simulations

    by Konstantin B. Borisenko, Helen J. Reavy, Qi Zhao, Eric W. Abel

    Protein-repellent diamond coatings have great potential value for surface coatings on implants and surgical instruments. The design of these coatings relies on a fundamental understanding of the intermolecular interactions involved in the adhesion of proteins to surfaces. To get insight into these interactions, adhesion energies of glycine to pure and Si and N-doped (111) diamond surfaces represented as clusters were calculated in the gas phase, using density functional theory (DFT) at the B3LYP/6-31G* level. The computed adhesion energies indicated that adhesion of glycine to diamond surface may be modified by introducing additional elements into the surface. The adhesion was also found to induce considerable change in the conformation of glycine when compared with the lowest-energy conformer of the free molecule. In the Si and N-substituted diamond clusters, notable changes in the structures involving the substituents atoms when compared with smaller parent molecules, such as 1-methyl-1-silaadamantane and 1-azaadamantane, were detected. Adhesion free energy differences were estimated for a series of representative peptides (hydrophobic Phe-Gly-Phe, amphiphilic Arg-Gly-Phe, and hydrophilic Arg-Gly-Arg) to a (111) diamond surface substituted with different amounts of N, Si, or F, using molecular dynamics simulations in an explicit water environment employing a Dreiding force field. The calculations were in agreement with the DFT results in that adsorption of the studied peptides to diamond surface is influenced by introducing additional elements to the surface. It has been shown that, in general, substitution will enhance electrostatic interactions between a surface and surrounding water, leading to a weaker adhesion of the studied peptides. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res 86A: 1113–1121, 2008


  • An anatomically shaped incus prosthesis for reconstruction of the ossicular chain

    by Richard M. Lord, Robert P. Mills, Eric W. Abel