Yong Hyun Chung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yong Hyun Chung has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
Su Jung An
Yonsei University
10 shared publicationsHyun-Il Kim
Korea Institute of Nuclear Safety, Daejeon, Republic of Korea
9 shared publicationsCheol-Ha Baek
Dongseo University
5 shared publicationsChae Young Lee
Department of Radiological Science, Yonsei University, Wonju, Republic of Korea
4 shared publicationsChanwoo Park
Yonsei Univ, Dept Radiat Convergence Engn, Wonju 26493, South Korea
4 shared publicationsMin Kyu Baek
Yonsei Univ, Dept Radiat Convergence Engn, Wonju 26493, South Korea
4 shared publications
Latest Publications
- 8 June 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1065
Corrigendum to “Feasibility study of a prototype muon tomography system based on a plastic scintillator and WLS fibers” [Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 1040 (2022) 167081]
- 8 June 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1065
Corrigendum to “Feasibility study of a prototype muon tomography system based on a plastic scintillator and WLS fibers” [Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 1040 (2022) 167081]
- Open Access
- 29 March 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (7) , 5915
Design of a Nuclear Monitoring System Based on a Multi-Sensor Network and Artificial Intelligence Algorithm
Nuclear power is a sustainable energy source, but radiation management is required for its safe use. Radiation-detection technology has been developed for the safe management of radioactive materials in nuclear facilities but its performance may vary depending on the size and complexity of the structure of nuclear facilities. In this study, a nuclear monitoring system using a multi-sensor network was designed to monitor radioactive materials in a large nuclear facility. Additionally, an artificial-intelligence-based localization algorithm was developed to accurately locate radioactive materials. The system parameters were optimized using the Geant4 Application for Tomographic emission (GATE) toolkit, and the localization algorithm was developed based on the performance evaluation of the Artificial Neural Network (ANN) and Decision Tree (D-Tree) models. In this article, we present the feasibility of the proposed monitoring system by converging the radiation detection system and artificial intelligence technology.
- 29 March 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (7) , 5915
Open AccessDesign of a Nuclear Monitoring System Based on a Multi-Sensor Network and Artificial Intelligence Algorithm
Nuclear power is a sustainable energy source, but radiation management is required for its safe use. Radiation-detection technology has been developed for the safe management of radioactive materials in nuclear facilities but its performance may vary depending on the size and complexity of the structure of nuclear facilities. In this study, a nuclear monitoring system using a multi-sensor network was designed to monitor radioactive materials in a large nuclear facility. Additionally, an artificial-intelligence-based localization algorithm was developed to accurately locate radioactive materials. The system parameters were optimized using the Geant4 Application for Tomographic emission (GATE) toolkit, and the localization algorithm was developed based on the performance evaluation of the Artificial Neural Network (ANN) and Decision Tree (D-Tree) models. In this article, we present the feasibility of the proposed monitoring system by converging the radiation detection system and artificial intelligence technology.
- 12 December 2022
- Published by Springer Nature in Journal of the Korean Physical Society
- Vol. 82 (2) , 133-138
Timing pickoff method for improvement of timing resolution in AGPET
- 12 December 2022
- Published by Springer Nature in Journal of the Korean Physical Society
- Vol. 82 (2) , 133-138
Timing pickoff method for improvement of timing resolution in AGPET
- 15 December 2021
- Published by Springer Nature in Journal of the Korean Physical Society
- Vol. 80 (2) , 110-116
Design and characterization of a hemispherical monitoring system for large-area radiation monitoring
- 15 December 2021
- Published by Springer Nature in Journal of the Korean Physical Society
- Vol. 80 (2) , 110-116
Design and characterization of a hemispherical monitoring system for large-area radiation monitoring
- 1 October 2017
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 128, 36-40
A radioactive material monitoring system using multiple gamma spectroscopy detectors and centroid method
- 1 October 2017
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 128, 36-40
A radioactive material monitoring system using multiple gamma spectroscopy detectors and centroid method
- 29 December 2016
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 69 (12) , 1842-1846
Development of a novel depth-of-interaction encoding method and use of light spreading in a scintillation crystal array with single-ended readout
- 29 December 2016
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 69 (12) , 1842-1846
Development of a novel depth-of-interaction encoding method and use of light spreading in a scintillation crystal array with single-ended readout
- 1 October 2016
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 69 (8) , 1356-1361
Monte Carlo modeling of a novel depth-encoding PET detector with DETECT2000
- 1 October 2016
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 69 (8) , 1356-1361
Monte Carlo modeling of a novel depth-encoding PET detector with DETECT2000
- Open Access
- 31 May 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (5) , e0156226
Optimization of Proton CT Detector System and Image Reconstruction Algorithm for On-Line Proton Therapy
The purposes of this study were to optimize a proton computed tomography system (pCT) for proton range verification and to confirm the pCT image reconstruction algorithm based on projection images generated with optimized parameters. For this purpose, we developed a new pCT scanner using the Geometry and Tracking (GEANT) 4.9.6 simulation toolkit. GEANT4 simulations were performed to optimize the geometric parameters representing the detector thickness and the distance between the detectors for pCT. The system consisted of four silicon strip detectors for particle tracking and a calorimeter to measure the residual energies of the individual protons. The optimized pCT system design was then adjusted to ensure that the solution to a CS-based convex optimization problem would converge to yield the desired pCT images after a reasonable number of iterative corrections. In particular, we used a total variation-based formulation that has been useful in exploiting prior knowledge about the minimal variations of proton attenuation characteristics in the human body. Examinations performed using our CS algorithm showed that high-quality pCT images could be reconstructed using sets of 72 projections within 20 iterations and without any streaks or noise, which can be caused by under-sampling and proton starvation. Moreover, the images yielded by this CS algorithm were found to be of higher quality than those obtained using other reconstruction algorithms. The optimized pCT scanner system demonstrated the potential to perform high-quality pCT during on-line image-guided proton therapy, without increasing the imaging dose, by applying our CS based proton CT reconstruction algorithm. Further, we make our optimized detector system and CS-based proton CT reconstruction algorithm potentially useful in on-line proton therapy.
- 31 May 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (5) , e0156226
Open AccessOptimization of Proton CT Detector System and Image Reconstruction Algorithm for On-Line Proton Therapy
The purposes of this study were to optimize a proton computed tomography system (pCT) for proton range verification and to confirm the pCT image reconstruction algorithm based on projection images generated with optimized parameters. For this purpose, we developed a new pCT scanner using the Geometry and Tracking (GEANT) 4.9.6 simulation toolkit. GEANT4 simulations were performed to optimize the geometric parameters representing the detector thickness and the distance between the detectors for pCT. The system consisted of four silicon strip detectors for particle tracking and a calorimeter to measure the residual energies of the individual protons. The optimized pCT system design was then adjusted to ensure that the solution to a CS-based convex optimization problem would converge to yield the desired pCT images after a reasonable number of iterative corrections. In particular, we used a total variation-based formulation that has been useful in exploiting prior knowledge about the minimal variations of proton attenuation characteristics in the human body. Examinations performed using our CS algorithm showed that high-quality pCT images could be reconstructed using sets of 72 projections within 20 iterations and without any streaks or noise, which can be caused by under-sampling and proton starvation. Moreover, the images yielded by this CS algorithm were found to be of higher quality than those obtained using other reconstruction algorithms. The optimized pCT scanner system demonstrated the potential to perform high-quality pCT during on-line image-guided proton therapy, without increasing the imaging dose, by applying our CS based proton CT reconstruction algorithm. Further, we make our optimized detector system and CS-based proton CT reconstruction algorithm potentially useful in on-line proton therapy.
- 1 February 2015
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 66 (4) , 585-591
Design and characterization of a small muon tomography system
Muon tomography is a useful method for monitoring special nuclear materials (SNMs) because it can provide effective information on the presence of high-Z materials, has a high enough energy to deeply penetrate large amounts of shielding, and does not lead to any health risks and danger above background. We developed a 2-D muon detector and designed a muon tomography system employing four detector modules. Two top and two bottom detectors are, respectively, employed to record the incident and the scattered muon trajectories. The detector module for the muon tomography system consists of a plastic scintillator, wavelength-shifting (WLS) fiber arrays placed orthogonally on the top and the bottom of the scintillator, and a position-sensitive photomultiplier (PSPMT). The WLS fiber arrays absorb light photons emitted by the plastic scintillator and re-emit green lights guided to the PSPMT. The light distribution among the WLS fiber arrays determines the position of the muon interaction; consequently, 3-D tomographic images can be obtained by extracting the crossing points of the individual muon trajectories by using a point-of-closest-approach algorithm. The goal of this study is to optimize the design parameters of a muon tomography system by using the Geant4 code and to experimentally evaluate the performance of the prototype detector. Images obtained by the prototype detector with a 420-nm laser light source showed good agreement with the simulation results. This indicates that the proposed detector is feasible for use in a muon tomography system and can be used to verify the Z-discrimination capability of the muon tomography system.
- 1 February 2015
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 66 (4) , 585-591
Design and characterization of a small muon tomography system
Muon tomography is a useful method for monitoring special nuclear materials (SNMs) because it can provide effective information on the presence of high-Z materials, has a high enough energy to deeply penetrate large amounts of shielding, and does not lead to any health risks and danger above background. We developed a 2-D muon detector and designed a muon tomography system employing four detector modules. Two top and two bottom detectors are, respectively, employed to record the incident and the scattered muon trajectories. The detector module for the muon tomography system consists of a plastic scintillator, wavelength-shifting (WLS) fiber arrays placed orthogonally on the top and the bottom of the scintillator, and a position-sensitive photomultiplier (PSPMT). The WLS fiber arrays absorb light photons emitted by the plastic scintillator and re-emit green lights guided to the PSPMT. The light distribution among the WLS fiber arrays determines the position of the muon interaction; consequently, 3-D tomographic images can be obtained by extracting the crossing points of the individual muon trajectories by using a point-of-closest-approach algorithm. The goal of this study is to optimize the design parameters of a muon tomography system by using the Geant4 code and to experimentally evaluate the performance of the prototype detector. Images obtained by the prototype detector with a 420-nm laser light source showed good agreement with the simulation results. This indicates that the proposed detector is feasible for use in a muon tomography system and can be used to verify the Z-discrimination capability of the muon tomography system.