Yevgeniy Vinogradskiy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yevgeniy Vinogradskiy has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Edward Castillo
Department of Radiation Oncology, Beaumont Health System, Royal Oak, Missouri
10 shared publicationsThomas Guerrero
Department of Radiation Oncology, Beaumont Health System, Royal Oak, Missouri
10 shared publicationsMoyed Miften
Department of Radiation Oncology, University of Colorado School of Medicine, Aurora, Colorado
9 shared publications- Richard Castillo
School of Medicine, Emory University, 1440 Clifton Rd N E, Atlanta, Georgia, 30322, United States
9 shared publications Brian Kavanagh
Department of Radiation Oncology, University of Colorado School of Medicine, Aurora, Colorado
6 shared publicationsLeah Schubert
Department of Radiation Oncology, University of Colorado School of Medicine, Aurora, Colorado
5 shared publications
Latest Publications
- Open Access
- 1 July 2019
- Published by Oxford University Press (OUP) in BJR|Open
- Vol. 1 (1)
CT-based ventilation imaging in radiation oncology
A form of lung function imaging is emerging that uses phase-resolved four-dimensional CT (4DCT or breath-hold CT) images along with image processing techniques to generate lung function maps that provide a surrogate of lung ventilation. CT-based ventilation (referred to as CT-ventilation) research has gained momentum in Radiation Oncology because many lung cancer patients undergo four-dimensional CT simulation as part of the standard treatment planning process. Therefore, generating CT-ventilation images provides functional information without burdening the patient with an extra imaging procedure. CT-ventilation has progressed from an image processing calculation methodology, to validation efforts, to retrospective demonstration of clinical utility in Radiation Oncology. In particular, CT-ventilation has been proposed for two main clinical applications: functional avoidance radiation therapy and thoracic dose–response assessment. The idea of functional avoidance radiation therapy is to preferentially spare functional portions of the lung (as measured by CT-ventilation) during radiation therapy with the hypothesis that reducing dose to functional portions of the lung will lead to reduced rates of radiation-related thoracic toxicity. The idea of imaging-based dose–response assessment is to evaluate pre- to post-treatment CT-ventilation-based imaging changes. The hypothesis is that early, imaging-change-based response can be an early predictor of subsequent thoracic toxicity. Based on the retrospective evidence, the clinical applications of CT-ventilation have progressed from the retrospective setting to on-going prospective clinical trials. This review will cover basic CT-ventilation calculation methodologies, validation efforts, presentation of clinical applications, summarize on-going clinical trials, review potential uncertainties and shortcomings of CT-ventilation, and discuss future directions of CT-ventilation research.
- 1 July 2019
- Published by Oxford University Press (OUP) in BJR|Open
- Vol. 1 (1)
Open AccessCT-based ventilation imaging in radiation oncology
A form of lung function imaging is emerging that uses phase-resolved four-dimensional CT (4DCT or breath-hold CT) images along with image processing techniques to generate lung function maps that provide a surrogate of lung ventilation. CT-based ventilation (referred to as CT-ventilation) research has gained momentum in Radiation Oncology because many lung cancer patients undergo four-dimensional CT simulation as part of the standard treatment planning process. Therefore, generating CT-ventilation images provides functional information without burdening the patient with an extra imaging procedure. CT-ventilation has progressed from an image processing calculation methodology, to validation efforts, to retrospective demonstration of clinical utility in Radiation Oncology. In particular, CT-ventilation has been proposed for two main clinical applications: functional avoidance radiation therapy and thoracic dose–response assessment. The idea of functional avoidance radiation therapy is to preferentially spare functional portions of the lung (as measured by CT-ventilation) during radiation therapy with the hypothesis that reducing dose to functional portions of the lung will lead to reduced rates of radiation-related thoracic toxicity. The idea of imaging-based dose–response assessment is to evaluate pre- to post-treatment CT-ventilation-based imaging changes. The hypothesis is that early, imaging-change-based response can be an early predictor of subsequent thoracic toxicity. Based on the retrospective evidence, the clinical applications of CT-ventilation have progressed from the retrospective setting to on-going prospective clinical trials. This review will cover basic CT-ventilation calculation methodologies, validation efforts, presentation of clinical applications, summarize on-going clinical trials, review potential uncertainties and shortcomings of CT-ventilation, and discuss future directions of CT-ventilation research.
- 1 November 2018
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 102 (4) , 1357-1365
Interim Analysis of a Two-Institution, Prospective Clinical Trial of 4DCT-Ventilation-based Functional Avoidance Radiation Therapy
- 1 November 2018
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 102 (4) , 1357-1365
Interim Analysis of a Two-Institution, Prospective Clinical Trial of 4DCT-Ventilation-based Functional Avoidance Radiation Therapy
- Open Access
- 26 June 2018
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 19 (5) , 407-412
Using 4DCT-ventilation to characterize lung function changes for pediatric patients getting thoracic radiotherapy
Purpose A form of lung functional imaging has been developed that uses 4DCT data to calculate ventilation (4DCT‐ventilation). Because 4DCTs are acquired as standard‐of‐care to manage breathing motion during radiotherapy, 4DCT‐ventilation provides functional information at no extra dosimetric or monetary cost. 4DCT‐ventilation has yet to be described in children. 4DCT‐ventilation can be used as a tool to help assess post‐treatment lung function and predict for future clinical thoracic toxicities for pediatric patients receiving radiotherapy to the chest. The purpose of this work was to perform a preliminary evaluation of 4DCT‐ventilation‐based lung function changes for pediatric patients receiving radiotherapy to the lungs. Methods The study used four patients with pre and postradiotherapy 4DCTs. The 4DCTs, deformable image registration, and a density‐change‐based algorithm were used to compute pre and post‐treatment 4DCT‐ventilation images. The post‐treatment 4DCT‐ventilation images were compared to the pretreatment 4DCT‐ventilation images for a global lung response and for an intrapatient dose–response (providing an assessment for dose‐dependent regional dose–response). Results For three of the four patients, a global ventilation decline of 7–37% was observed, while one patient did not demonstrate a global functional decline. Dose–response analysis did not reveal an intrapatient dose–response from 0 to 20 Gy for three patients while one patient demonstrated increased 4DCT‐ventilation decline as a function of increasing lung doses up to 50 Gy. Conclusions Compared to adults, pediatric patients have unique lung function, dosimetric, and toxicity profiles. The presented work is the first to evaluate spatial lung function changes in pediatric patients using 4DCT‐ventilation and showed lung function changes for three of the four patients. The early changes demonstrated with lung function imaging warrant further longitudinal work to determine whether the imaging‐based early changes can be predicted for long‐term clinical toxicity.
- 26 June 2018
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 19 (5) , 407-412
Open AccessUsing 4DCT-ventilation to characterize lung function changes for pediatric patients getting thoracic radiotherapy
Purpose A form of lung functional imaging has been developed that uses 4DCT data to calculate ventilation (4DCT‐ventilation). Because 4DCTs are acquired as standard‐of‐care to manage breathing motion during radiotherapy, 4DCT‐ventilation provides functional information at no extra dosimetric or monetary cost. 4DCT‐ventilation has yet to be described in children. 4DCT‐ventilation can be used as a tool to help assess post‐treatment lung function and predict for future clinical thoracic toxicities for pediatric patients receiving radiotherapy to the chest. The purpose of this work was to perform a preliminary evaluation of 4DCT‐ventilation‐based lung function changes for pediatric patients receiving radiotherapy to the lungs. Methods The study used four patients with pre and postradiotherapy 4DCTs. The 4DCTs, deformable image registration, and a density‐change‐based algorithm were used to compute pre and post‐treatment 4DCT‐ventilation images. The post‐treatment 4DCT‐ventilation images were compared to the pretreatment 4DCT‐ventilation images for a global lung response and for an intrapatient dose–response (providing an assessment for dose‐dependent regional dose–response). Results For three of the four patients, a global ventilation decline of 7–37% was observed, while one patient did not demonstrate a global functional decline. Dose–response analysis did not reveal an intrapatient dose–response from 0 to 20 Gy for three patients while one patient demonstrated increased 4DCT‐ventilation decline as a function of increasing lung doses up to 50 Gy. Conclusions Compared to adults, pediatric patients have unique lung function, dosimetric, and toxicity profiles. The presented work is the first to evaluate spatial lung function changes in pediatric patients using 4DCT‐ventilation and showed lung function changes for three of the four patients. The early changes demonstrated with lung function imaging warrant further longitudinal work to determine whether the imaging‐based early changes can be predicted for long‐term clinical toxicity.
- Open Access
- 24 April 2017
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 18 (3) , 144-152
A complete 4DCT‐ventilation functional avoidance virtual trial: Developing strategies for prospective clinical trials
Introduction: 4DCT‐ventilation is an exciting new imaging modality that uses 4DCT data to calculate lung‐function maps. Because 4DCTs are acquired as standard of care for lung cancer patients undergoing radiotherapy, 4DCT‐ventiltation provides functional information at no extra dosimetric or monetary cost to the patient. The development of clinical trials is underway to use 4DCT‐ventilation imaging to spare functional lung in patients undergoing radiotherapy. The purpose of this work was to perform a virtual trial using retrospective data to develop the practical aspects of a 4DCT‐ventilation functional avoidance clinical trial.Methods: The study included 96 stage III lung cancer patients. A 4DCT‐ventilation map was calculated using the patient's 4DCT‐imaging, deformable registration, and a density‐change‐based algorithm. Clinical trial inclusion assessment used quantitative and qualitative metrics based on the patient's spatial ventilation profile. Clinical and functional plans were generated for 25 patients. The functional plan aimed to reduce dose to functional lung while meeting standard target and critical structure constraints. Standard and dose‐function metrics were compared between the clinical and functional plans.Results: Our data showed that 69% and 59% of stage III patients have regional variability in function based on qualitative and quantitative metrics, respectively. Functional planning demonstrated an average reduction of 2.8 Gy (maximum 8.2 Gy) in the mean dose to functional lung.Conclusions: Our work demonstrated that 60–70% of stage III patients would be eligible for functional planning and that a typical functional lung mean dose reduction of 2.8 Gy can be expected relative to standard clinical plans. These findings provide salient data for the development of functional clinical trials.
- 24 April 2017
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 18 (3) , 144-152
Open AccessA complete 4DCT‐ventilation functional avoidance virtual trial: Developing strategies for prospective clinical trials
Introduction: 4DCT‐ventilation is an exciting new imaging modality that uses 4DCT data to calculate lung‐function maps. Because 4DCTs are acquired as standard of care for lung cancer patients undergoing radiotherapy, 4DCT‐ventiltation provides functional information at no extra dosimetric or monetary cost to the patient. The development of clinical trials is underway to use 4DCT‐ventilation imaging to spare functional lung in patients undergoing radiotherapy. The purpose of this work was to perform a virtual trial using retrospective data to develop the practical aspects of a 4DCT‐ventilation functional avoidance clinical trial.Methods: The study included 96 stage III lung cancer patients. A 4DCT‐ventilation map was calculated using the patient's 4DCT‐imaging, deformable registration, and a density‐change‐based algorithm. Clinical trial inclusion assessment used quantitative and qualitative metrics based on the patient's spatial ventilation profile. Clinical and functional plans were generated for 25 patients. The functional plan aimed to reduce dose to functional lung while meeting standard target and critical structure constraints. Standard and dose‐function metrics were compared between the clinical and functional plans.Results: Our data showed that 69% and 59% of stage III patients have regional variability in function based on qualitative and quantitative metrics, respectively. Functional planning demonstrated an average reduction of 2.8 Gy (maximum 8.2 Gy) in the mean dose to functional lung.Conclusions: Our work demonstrated that 60–70% of stage III patients would be eligible for functional planning and that a typical functional lung mean dose reduction of 2.8 Gy can be expected relative to standard clinical plans. These findings provide salient data for the development of functional clinical trials.
- 19 January 2017
- Published by Wiley in Medical Physics
- Vol. 44 (1) , 200-208
Assessing the use of 4DCT‐ventilation in pre‐operative surgical lung cancer evaluation
Purpose: A primary treatment option for lung cancer patients is surgical resection. Patients who have poor lung function prior to surgery are at increased risk of developing serious and life‐threatening complications after surgical resection. Surgeons use nuclear medicine ventilation‐perfusion (VQ) scans along with pulmonary function test (PFT) information to assess a patient's pre‐surgical lung function. The nuclear medicine images and pre‐surgery PFTs are used to calculate percent predicted postoperative (%PPO) PFT values by estimating the amount of functioning lung tissue that would be lost with surgical resection. Nuclear medicine imaging is currently considered the standard of care when evaluating the amount of ventilation that would be lost due to surgery. A novel lung function imaging modality has been developed in radiation oncology that uses 4‐Dimensional computed tomography data to calculate ventilation maps (4DCT‐ventilation). Compared to nuclear medicine, 4DCT‐ventilation is cheaper, does not require a radioactive contrast agent, provides a faster imaging procedure, and has improved spatial resolution. In this work we perform a retrospective study to assess the use of 4DCT‐ventilation as a pre‐operative surgical lung function evaluation tool. Specifically, the purpose of our study was to compare %PPO PFT values calculated with 4DCT‐ventilation and %PPO PFT values calculated with nuclear medicine ventilation‐perfusion imaging.Methods: The study included 16 lung cancer patients that had undergone 4DCT imaging, nuclear medicine imaging, and had Forced Expiratory Volume in 1 second (FEV1) acquired as part of a standard PFT. The 4DCT datasets, spatial registration, and a density‐change‐based model were used to compute 4DCT‐ventilation maps. Both 4DCT‐ventilation and nuclear medicine images were used to calculate %PPO FEV1. The %PPO FEV1 was calculated by scaling the pre‐surgical FEV1 by (1‐fraction of total resected ventilation); where the resected ventilation was determined using either the 4DCT‐ventilation or nuclear medicine imaging. Calculations were done assuming both lobectomy and pneumonectomy resections. The %PPO FEV1 values were compared between the 4DCT‐ventilation‐based calculations and the nuclear medicine‐based calculations using correlation coefficients, average differences, and Receiver Operating Characteristic (ROC) analysis.Results: Overall the 4DCT‐ventilation derived %PPO FEV1 values agreed well with nuclear medicine‐derived %PPO FEV1 data with correlations of 0.99 and 0.81 for lobectomy and pneumonectomy, respectively. The average differences between the 4DCT‐ventilation and nuclear medicine‐based calculation for %PPO FEV1 were less than 5%. ROC analysis revealed predictive accuracy that ranged from 87.5% to 100% when assessing the ability of 4DCT‐ventilation to predict for nuclear medicine‐based %PPO FEV1 values.Conclusions: 4DCT‐ventilation is an innovative technology developed in radiation oncology that has great potential to translate to the surgical domain. The high correlation results when comparing 4DCT‐ventilation to the current standard of care provide a strong rationale for a prospective clinical trial assessing 4DCT‐ventilation in the clinical setting. 4DCT‐ventilation can reduce the cost and imaging time for patients while providing improved spatial accuracy and quantitative results for surgeons.
- 19 January 2017
- Published by Wiley in Medical Physics
- Vol. 44 (1) , 200-208
Assessing the use of 4DCT‐ventilation in pre‐operative surgical lung cancer evaluation
Purpose: A primary treatment option for lung cancer patients is surgical resection. Patients who have poor lung function prior to surgery are at increased risk of developing serious and life‐threatening complications after surgical resection. Surgeons use nuclear medicine ventilation‐perfusion (VQ) scans along with pulmonary function test (PFT) information to assess a patient's pre‐surgical lung function. The nuclear medicine images and pre‐surgery PFTs are used to calculate percent predicted postoperative (%PPO) PFT values by estimating the amount of functioning lung tissue that would be lost with surgical resection. Nuclear medicine imaging is currently considered the standard of care when evaluating the amount of ventilation that would be lost due to surgery. A novel lung function imaging modality has been developed in radiation oncology that uses 4‐Dimensional computed tomography data to calculate ventilation maps (4DCT‐ventilation). Compared to nuclear medicine, 4DCT‐ventilation is cheaper, does not require a radioactive contrast agent, provides a faster imaging procedure, and has improved spatial resolution. In this work we perform a retrospective study to assess the use of 4DCT‐ventilation as a pre‐operative surgical lung function evaluation tool. Specifically, the purpose of our study was to compare %PPO PFT values calculated with 4DCT‐ventilation and %PPO PFT values calculated with nuclear medicine ventilation‐perfusion imaging.Methods: The study included 16 lung cancer patients that had undergone 4DCT imaging, nuclear medicine imaging, and had Forced Expiratory Volume in 1 second (FEV1) acquired as part of a standard PFT. The 4DCT datasets, spatial registration, and a density‐change‐based model were used to compute 4DCT‐ventilation maps. Both 4DCT‐ventilation and nuclear medicine images were used to calculate %PPO FEV1. The %PPO FEV1 was calculated by scaling the pre‐surgical FEV1 by (1‐fraction of total resected ventilation); where the resected ventilation was determined using either the 4DCT‐ventilation or nuclear medicine imaging. Calculations were done assuming both lobectomy and pneumonectomy resections. The %PPO FEV1 values were compared between the 4DCT‐ventilation‐based calculations and the nuclear medicine‐based calculations using correlation coefficients, average differences, and Receiver Operating Characteristic (ROC) analysis.Results: Overall the 4DCT‐ventilation derived %PPO FEV1 values agreed well with nuclear medicine‐derived %PPO FEV1 data with correlations of 0.99 and 0.81 for lobectomy and pneumonectomy, respectively. The average differences between the 4DCT‐ventilation and nuclear medicine‐based calculation for %PPO FEV1 were less than 5%. ROC analysis revealed predictive accuracy that ranged from 87.5% to 100% when assessing the ability of 4DCT‐ventilation to predict for nuclear medicine‐based %PPO FEV1 values.Conclusions: 4DCT‐ventilation is an innovative technology developed in radiation oncology that has great potential to translate to the surgical domain. The high correlation results when comparing 4DCT‐ventilation to the current standard of care provide a strong rationale for a prospective clinical trial assessing 4DCT‐ventilation in the clinical setting. 4DCT‐ventilation can reduce the cost and imaging time for patients while providing improved spatial accuracy and quantitative results for surgeons.
- 1 June 2015
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 92 (2) , 423-429
Clinical Validation of 4-Dimensional Computed Tomography Ventilation With Pulmonary Function Test Data
- 1 June 2015
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 92 (2) , 423-429
Clinical Validation of 4-Dimensional Computed Tomography Ventilation With Pulmonary Function Test Data
- 23 July 2013
- Published by Wiley in Medical Physics
- Vol. 40 (8) , 081712
Spatial and dose-response analysis of fibrotic lung changes after stereotactic body radiation therapy
Stereotactic body radiation therapy (SBRT) is becoming the standard of care for early stage nonoperable lung cancers. Accurate dose-response modeling is challenging for SBRT because of the decreased number of clinical toxicity events. As a surrogate for a clinical toxicity endpoint, studies have proposed to use radiographic changes in follow up computed tomography (CT) scans to evaluate lung SBRT normal tissue effects. The purpose of the current study was to use local fibrotic lung regions to spatially and dosimetrically evaluate lung changes in patients that underwent SBRT. Forty seven SBRT patients treated at our institution from 2003 to 2009 were used for the current study. Our patient cohort had a total of 148 follow up CT scans ranging from 3 to 48 months post-therapy. Post-treatment scans were binned into intervals of 3, 6, 12, 18, 24, 30, and 36 months after the completion of treatment. Deformable image registration was used to align the follow up CT scans with the pretreatment CT and dose distribution. Areas of visible fibrotic changes were contoured. The centroid of each gross tumor volume (GTV) and contoured fibrosis volume was calculated and the fibrosis volume location and movement (magnitude and direction) relative to the GTV and 30 Gy isodose centroid were analyzed. To perform a dose-response analysis, each voxel in the fibrosis volume was sorted into 10 Gy dose bins and the average CT number value for each dose bin was calculated. Dose-response curves were generated by plotting the CT number as a function of dose bin and time posttherapy. Both fibrosis and GTV centroids were concentrated in the upper third of the lung. The average radial movement of fibrosis centroids relative to the GTV centroids was 2.6 cm with movement greater than 5 cm occurring in 11% of patients. Evaluating dose-response curves revealed an overall trend of increasing CT number as a function of dose. The authors observed a CT number plateau at doses ranging from 30 to 50 Gy for the 3, 6, and 12 months posttherapy time points. There was no evident plateau for the dose-response curves generated using data from the 18, 24, 30, and 36 months posttherapy time points. Regions of local fibrotic lung changes in patients that underwent SBRT were evaluated spatially and dosimetrically. The authors found that the average fibrosis movement was 2.6 cm with movement greater than 5 cm possible. Evaluating dose-response curves revealed an overall trend of increasing CT number as a function of dose. Furthermore, our dose-response data also suggest that one of the possible explanations of the CT number plateau effect may be the time posttherapy of the acquired data. Understanding normal tissue dose-response is important for reducing toxicity after SBRT, especially in cases where larger tumors are treated. The methods presented in the current work build on prior quantitative studies and further enhance the understanding of normal lung dose-response after SBRT.
- 23 July 2013
- Published by Wiley in Medical Physics
- Vol. 40 (8) , 081712
Spatial and dose-response analysis of fibrotic lung changes after stereotactic body radiation therapy
Stereotactic body radiation therapy (SBRT) is becoming the standard of care for early stage nonoperable lung cancers. Accurate dose-response modeling is challenging for SBRT because of the decreased number of clinical toxicity events. As a surrogate for a clinical toxicity endpoint, studies have proposed to use radiographic changes in follow up computed tomography (CT) scans to evaluate lung SBRT normal tissue effects. The purpose of the current study was to use local fibrotic lung regions to spatially and dosimetrically evaluate lung changes in patients that underwent SBRT. Forty seven SBRT patients treated at our institution from 2003 to 2009 were used for the current study. Our patient cohort had a total of 148 follow up CT scans ranging from 3 to 48 months post-therapy. Post-treatment scans were binned into intervals of 3, 6, 12, 18, 24, 30, and 36 months after the completion of treatment. Deformable image registration was used to align the follow up CT scans with the pretreatment CT and dose distribution. Areas of visible fibrotic changes were contoured. The centroid of each gross tumor volume (GTV) and contoured fibrosis volume was calculated and the fibrosis volume location and movement (magnitude and direction) relative to the GTV and 30 Gy isodose centroid were analyzed. To perform a dose-response analysis, each voxel in the fibrosis volume was sorted into 10 Gy dose bins and the average CT number value for each dose bin was calculated. Dose-response curves were generated by plotting the CT number as a function of dose bin and time posttherapy. Both fibrosis and GTV centroids were concentrated in the upper third of the lung. The average radial movement of fibrosis centroids relative to the GTV centroids was 2.6 cm with movement greater than 5 cm occurring in 11% of patients. Evaluating dose-response curves revealed an overall trend of increasing CT number as a function of dose. The authors observed a CT number plateau at doses ranging from 30 to 50 Gy for the 3, 6, and 12 months posttherapy time points. There was no evident plateau for the dose-response curves generated using data from the 18, 24, 30, and 36 months posttherapy time points. Regions of local fibrotic lung changes in patients that underwent SBRT were evaluated spatially and dosimetrically. The authors found that the average fibrosis movement was 2.6 cm with movement greater than 5 cm possible. Evaluating dose-response curves revealed an overall trend of increasing CT number as a function of dose. Furthermore, our dose-response data also suggest that one of the possible explanations of the CT number plateau effect may be the time posttherapy of the acquired data. Understanding normal tissue dose-response is important for reducing toxicity after SBRT, especially in cases where larger tumors are treated. The methods presented in the current work build on prior quantitative studies and further enhance the understanding of normal lung dose-response after SBRT.