D. J. Hoarty
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
D. J. Hoarty has a total of 99 co-authors. Here are the top co-authors by number of shared publications:
J.W.O. Harris
AWE, Aldermaston, Berkshire, United Kingdom
4 shared publications- Matthew P. Hill
Lawrence Livermore National Laboratory
4 shared publications - Basil J. B. Crowley
University of Oxford
3 shared publications - Gregory V. Brown
Lawrence Livermore National Laboratory
3 shared publications S.F. James
3 shared publicationsC R D Brown
Directorate of Research and Applied Science, AWE plc, Reading, RG7 4PR, UK
2 shared publications
Latest Publications
- 1 February 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (2)
High resolution, sub-picosecond x-ray spectroscopy of K-shell emitters to characterize plasma emissivity measurement
Short pulse laser (SPL) heated matter has opened an avenue to studying matter at conditions previously unattainable. While SPLs can generate matter at extreme densities and temperatures, characterization of the heated matter can be extremely challenging. The conditions are dynamic and require careful monitoring of the plasma evolution. Atomic processes under these conditions can provide a powerful tool to study fundamental plasma properties as they evolve. When utilizing the x-ray emission from these plasmas, it is often useful to resolve spectral details with high resolution. Sub-picosecond, time-resolved, high-resolution spectroscopy has previously been reported. We present a similar diagnostic (STreaked Orion High-Resolution X-ray spectrometer, or STOHREX) to measure the temporal evolution of spectral features with high spectral resolution. The diagnostic is the result of combining a high-resolution x-ray spectrometer with the LLNL sub-picosecond x-ray streak camera. The diagnostic was demonstrated in two campaigns: (1) To study spectral lineshapes using the 40 fs, 400 nm, Colorado State University ALEPH laser, and (2) to study buried layers using the 500 fs, 532 nm Atomic Weapons Establishment’s Orion laser.
- 1 February 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (2)
High resolution, sub-picosecond x-ray spectroscopy of K-shell emitters to characterize plasma emissivity measurement
Short pulse laser (SPL) heated matter has opened an avenue to studying matter at conditions previously unattainable. While SPLs can generate matter at extreme densities and temperatures, characterization of the heated matter can be extremely challenging. The conditions are dynamic and require careful monitoring of the plasma evolution. Atomic processes under these conditions can provide a powerful tool to study fundamental plasma properties as they evolve. When utilizing the x-ray emission from these plasmas, it is often useful to resolve spectral details with high resolution. Sub-picosecond, time-resolved, high-resolution spectroscopy has previously been reported. We present a similar diagnostic (STreaked Orion High-Resolution X-ray spectrometer, or STOHREX) to measure the temporal evolution of spectral features with high spectral resolution. The diagnostic is the result of combining a high-resolution x-ray spectrometer with the LLNL sub-picosecond x-ray streak camera. The diagnostic was demonstrated in two campaigns: (1) To study spectral lineshapes using the 40 fs, 400 nm, Colorado State University ALEPH laser, and (2) to study buried layers using the 500 fs, 532 nm Atomic Weapons Establishment’s Orion laser.
- Open Access
- 1 June 2023
- Published by AIP Publishing in Physics of Plasmas
- Vol. 30 (6)
Radiation burnthrough measurements to infer opacity at conditions close to the solar radiative zone–convective zone boundary
Recent measurements at the Sandia National Laboratory of the x-ray transmission of iron plasma have inferred opacities much higher than predicted by theory, which casts doubt on modeling of iron x-ray radiative opacity at conditions close to the solar convective zone-radiative zone boundary. An increased radiative opacity of the solar mixture, in particular iron, is a possible explanation for the disagreement in the position of the solar convection zone-radiative zone boundary as measured by helioseismology and predicted by modeling using the most recent photosphere analysis of the elemental composition. Here, we present data from radiation burnthrough experiments, which do not support a large increase in the opacity of iron at conditions close to the base of the solar convection zone and provide a constraint on the possible values of both the mean opacity and the opacity in the x-ray range of the Sandia experiments. The data agree with opacity values from current state-of-the-art opacity modeling using the CASSANDRA opacity code.
- 1 June 2023
- Published by AIP Publishing in Physics of Plasmas
- Vol. 30 (6)
Open AccessRadiation burnthrough measurements to infer opacity at conditions close to the solar radiative zone–convective zone boundary
Recent measurements at the Sandia National Laboratory of the x-ray transmission of iron plasma have inferred opacities much higher than predicted by theory, which casts doubt on modeling of iron x-ray radiative opacity at conditions close to the solar convective zone-radiative zone boundary. An increased radiative opacity of the solar mixture, in particular iron, is a possible explanation for the disagreement in the position of the solar convection zone-radiative zone boundary as measured by helioseismology and predicted by modeling using the most recent photosphere analysis of the elemental composition. Here, we present data from radiation burnthrough experiments, which do not support a large increase in the opacity of iron at conditions close to the base of the solar convection zone and provide a constraint on the possible values of both the mean opacity and the opacity in the x-ray range of the Sandia experiments. The data agree with opacity values from current state-of-the-art opacity modeling using the CASSANDRA opacity code.
- Open Access
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1811, 050001
Measurements of plasma spectra from hot dense elements and mixtures at conditions relevant to the solar radiative zone
X-ray emission spectroscopy has been used to study hot dense plasmas produced using high power laser irradiation of dot samples buried in low Z foils of plastic or diamond. By combining a high contrast short pulse (picosecond timescale) laser beam operating in second harmonic with long pulse (nanosecond timescale) laser beams in third harmonic, and with pulse shaping of the long pulse beams, a range of plasma temperatures from 400eV up to 2.5keV and electron densities from 5e22 up to 1e24/cc have been accessed. Examples are given of measurements of dense plasma effects such as ionization potential depression and line-broadening from the K-shell emission spectra of a range of low Z elements and mixtures and compared to model prediction. Detailed spectra from measurements of the L-shell emission from mid-Z elements are also presented for an example spectrum of germanium. These data are at conditions found in stellar interiors and in particular in the radiative zone of the sun. The plasma conditions are inferred from comparison of the measured spectra to detailed modeling using atomic kinetics and spectral synthesis codes.
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1811, 050001
Open AccessMeasurements of plasma spectra from hot dense elements and mixtures at conditions relevant to the solar radiative zone
X-ray emission spectroscopy has been used to study hot dense plasmas produced using high power laser irradiation of dot samples buried in low Z foils of plastic or diamond. By combining a high contrast short pulse (picosecond timescale) laser beam operating in second harmonic with long pulse (nanosecond timescale) laser beams in third harmonic, and with pulse shaping of the long pulse beams, a range of plasma temperatures from 400eV up to 2.5keV and electron densities from 5e22 up to 1e24/cc have been accessed. Examples are given of measurements of dense plasma effects such as ionization potential depression and line-broadening from the K-shell emission spectra of a range of low Z elements and mixtures and compared to model prediction. Detailed spectra from measurements of the L-shell emission from mid-Z elements are also presented for an example spectrum of germanium. These data are at conditions found in stellar interiors and in particular in the radiative zone of the sun. The plasma conditions are inferred from comparison of the measured spectra to detailed modeling using atomic kinetics and spectral synthesis codes.
- 1 September 2016
- Published by Elsevier in High Energy Density Physics
- Vol. 20, 1-8
On the Optimized Atomic Exchange Potential method and the CASSANDRA opacity code
- 1 September 2016
- Published by Elsevier in High Energy Density Physics
- Vol. 20, 1-8
On the Optimized Atomic Exchange Potential method and the CASSANDRA opacity code
- Open Access
- 31 March 2016
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 688 (1) , 012032
The first data from the Orion laser: measurements of the spectrum of hot dense aluminium
The newly commissioned Orion laser system has been used to study dense plasmas created by a combination of short pulse laser heating and compression by laser driven shocks. Thus the plasma density was systematically varied between 1 and 10g/cc by using aluminium samples buried in plastic foils or diamond sheets. The aluminium was heated to electron temperatures between 500eV and 700eV allowing the plasma conditions to be diagnosed by K- shell emission spectroscopy. The K-shell spectra show the effect of the ionization potential depression as a function of density via the delocalization of n=3 levels and disappearance of n=3 transitions in He-like and H-like aluminium. The data are compared to simulated spectra, which account for the change in the ionization potential by the commonly used Stewart and Pyatt prescription; a simple ion sphere model and an alternative due to Ecker and Kroll suggested by recent X-ray free-electron laser experiments. The experimental data are in reasonable agreement with the model of Stewart and Pyatt, but are in better agreement with a simple ion sphere model. The data indicate that the Ecker and Kröll model overestimates substantially the ionization potential depression in this regime.
- 31 March 2016
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 688 (1) , 012032
Open AccessThe first data from the Orion laser: measurements of the spectrum of hot dense aluminium
The newly commissioned Orion laser system has been used to study dense plasmas created by a combination of short pulse laser heating and compression by laser driven shocks. Thus the plasma density was systematically varied between 1 and 10g/cc by using aluminium samples buried in plastic foils or diamond sheets. The aluminium was heated to electron temperatures between 500eV and 700eV allowing the plasma conditions to be diagnosed by K- shell emission spectroscopy. The K-shell spectra show the effect of the ionization potential depression as a function of density via the delocalization of n=3 levels and disappearance of n=3 transitions in He-like and H-like aluminium. The data are compared to simulated spectra, which account for the change in the ionization potential by the commonly used Stewart and Pyatt prescription; a simple ion sphere model and an alternative due to Ecker and Kroll suggested by recent X-ray free-electron laser experiments. The experimental data are in reasonable agreement with the model of Stewart and Pyatt, but are in better agreement with a simple ion sphere model. The data indicate that the Ecker and Kröll model overestimates substantially the ionization potential depression in this regime.
- 1 September 2015
- Published by Elsevier in High Energy Density Physics
- Vol. 16, 12-17
Characterization of near-LTE, high-temperature and high-density aluminum plasmas produced by ultra-high intensity lasers
- 1 September 2015
- Published by Elsevier in High Energy Density Physics
- Vol. 16, 12-17
Characterization of near-LTE, high-temperature and high-density aluminum plasmas produced by ultra-high intensity lasers
- Open Access
- 28 February 2011
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 106 (9) , 095001
Spatially Resolved Measurements of Laser Filamentation in Long Scale Length Underdense Plasmas with and without Beam Smoothing
The onset of filamentation, following the interaction of a relatively long ($\tau${}L$\simeq${}1\,\,ns) and intense (IL$\simeq${}5\ifmmode\times\else\texttimes\fi{}1014\,\,W/cm2) laser pulse with a neopentane filled gas bag target, has been experimentally studied via the proton radiography technique, in conditions of direct relevance to the indirect drive inertial confinement fusion scheme. The density gradients associated with filamentation onset have been spatially resolved yielding direct and unambiguous evidence of filament formation and quantitative information about the filamentation mechanism in agreement with previous theoretical modelings. Experimental data confirm that, once spatially smoothed laser beams are used, filamentation is not a relevant phenomenon during the heating laser beams propagation through typical hohlraum gas fills.
- 28 February 2011
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 106 (9) , 095001
Open AccessSpatially Resolved Measurements of Laser Filamentation in Long Scale Length Underdense Plasmas with and without Beam Smoothing
The onset of filamentation, following the interaction of a relatively long ($\tau${}L$\simeq${}1\,\,ns) and intense (IL$\simeq${}5\ifmmode\times\else\texttimes\fi{}1014\,\,W/cm2) laser pulse with a neopentane filled gas bag target, has been experimentally studied via the proton radiography technique, in conditions of direct relevance to the indirect drive inertial confinement fusion scheme. The density gradients associated with filamentation onset have been spatially resolved yielding direct and unambiguous evidence of filament formation and quantitative information about the filamentation mechanism in agreement with previous theoretical modelings. Experimental data confirm that, once spatially smoothed laser beams are used, filamentation is not a relevant phenomenon during the heating laser beams propagation through typical hohlraum gas fills.
- Open Access
- 1 August 2010
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 244 (1) , 012002
High temperature, high density opacity measurements using short pulse lasers
- 1 August 2010
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 244 (1) , 012002
Open AccessHigh temperature, high density opacity measurements using short pulse lasers
- 31 January 2010
- Published by Elsevier in High Energy Density Physics
- Vol. 6 (1) , 95-98
A comparison of theory and experiment for high density, high temperature germanium spectra
- 31 January 2010
- Published by Elsevier in High Energy Density Physics
- Vol. 6 (1) , 95-98
A comparison of theory and experiment for high density, high temperature germanium spectra
- 9 June 2009
- Published by Elsevier in High Energy Density Physics
- Vol. 6 (1) , 105-108
Measurements of emission spectra from hot, dense germanium plasma in short pulse laser experiments
- 9 June 2009
- Published by Elsevier in High Energy Density Physics
- Vol. 6 (1) , 105-108
Measurements of emission spectra from hot, dense germanium plasma in short pulse laser experiments