    Detailed measurements of oesophageal pressure during mechanical ventilation with an advanced high-resolution manometry catheter

    by Per Persson, Rebecca Ahlstrand, Magni Gudmundsson, Alex de Leon, Stefan Lundin

    Oesophageal pressure (PES) is used for calculation of lung and chest wall mechanics and transpulmonary pressure during mechanical ventilation. Measurements performed with a balloon catheter are suggested as a basis for setting the ventilator; however, measurements are affected by several factors. High-resolution manometry (HRM) simultaneously measures pressures at every centimetre in the whole oesophagus and thereby provides extended information about oesophageal pressure. The aim of the present study was to evaluate the factors affecting oesophageal pressure using HRM. Oesophageal pressure was measured using a high-resolution manometry catheter in 20 mechanically ventilated patients (15 in the ICU and 5 in the OR). Different PEEP levels and different sizes of tidal volume were applied while pressures were measured continuously. In 10 patients, oesophageal pressure was also measured using a conventional balloon catheter for comparison. A retrospective analysis of oesophageal pressure measured with HRM in supine and sitting positions in 17 awake spontaneously breathing patients is also included. HRM showed large variations in end-expiratory PES (PESEE) and tidal changes in PES (ΔPES) along the oesophagus. Mean intra-individual difference between the minimum and maximum end-expiratory oesophageal pressure (PESEE at baseline PEEP) and tidal variations in oesophageal pressure (ΔPES at tidal volume 6 ml/kg) recorded by HRM in the different sections of the oesophagus was 23.7 (7.9) cmH2O and 7.6 (3.9) cmH2O respectively. Oesophageal pressures were affected by tidal volume, level of PEEP, part of the oesophagus included and patient positioning. HRM identified simultaneous increases and decreases in PES within a majority of individual patients. Compared to sitting position, supine position increased PESEE (mean difference 12.3 cmH2O), pressure variation within individual patients and cardiac artefacts. The pressure measured with a balloon catheter did not correspond to the average pressure measured with HRM within the same part of the oesophagus. The intra-individual variability in PESEE and ΔPES is substantial, and as a result, the balloon on the conventional catheter is affected by many different pressures along its length. Oesophageal pressures are not only affected by lung and chest wall mechanics but are a complex product of many factors, which is not obvious during conventional measurements. For correct calculations of transpulmonary pressure, factors influencing oesophageal pressures need to be known. HRM, which is available at many hospitals, can be used to increase the knowledge concerning these factors. ClinicalTrials.gov, NCT02901158


  • Lung elastance and transpulmonary pressure can be determined without using oesophageal pressure measurements

    by O. Stenqvist, C. Grivans, B. Andersson, S. Lundin

    Introduction The aim of the present study was to demonstrate that lung elastance and transpulmonary pressure can be determined without using oesophageal pressure measurements. Methods Studies were performed on 13 anesthetized and sacrificed ex vivo pigs. Tracheal and oesophageal pressures were measured and changes in end‐expiratory lung volume (ΔEELV) determined by spirometry as the cumulative inspiratory‐expiratory tidal volume difference. Studies were performed with different end‐expiratory pressure steps [change in end‐expiratory airway pressure (ΔPEEP)], body positions and with abdominal load. Results A PEEP increase results in a multi‐breath build‐up of end‐expiratory lung volume. End‐expiratory oesophageal pressure did not increase further after the first expiration, constituting half of the change in ΔEELV following a PEEP increase, even though end‐expiratory volume continued to increase. This resulted in a successive left shift of the chest wall pressure–volume curve. Even at a PEEP of 12 cmH2O did the end‐expiratory oesophageal (pleural) pressure remain negative. Conclusions A PEEP increase resulted in a less than expected increase in end‐expiratory oesophageal pressure, indicating that the chest wall and abdomen gradually can accommodate changes in lung volume. The rib cage end‐expiratory spring‐out force stretches the diaphragm and prevents the lung from being compressed by abdominal pressure. The increase in transpulmonary pressure following a PEEP increase was closely related to the increase in PEEP, indicating that lung compliance can be calculated from the ratio of the change in end‐expiratory lung volume and the change in PEEP, ΔEELV/ΔPEEP.


  • Electrical impedance tomography

    by Stefan Lundin, Ola Stenqvist

    Electrical impedance tomography (EIT) is a useful noninvasive tool for monitoring ventilation finding its way into the clinical setting. The focus of this review is to discuss the balance between the potential for EIT as a clinical monitor accepting a level of uncertainty and the scientific demand for absolute perfection. The controversy concerning whether EIT impedance changes can be safely used to monitor lung volume changes now appears to be solved after recent elegant studies. It is now high time to display lung volume changes measured by EIT in clinical units, that is in millilitres following calibration versus tidal volume. A growing number of indices for regional ventilation distribution are emerging some of which should be further evaluated and developed for clinical decision support. Already now EIT is a useful clinical monitor. Still more work is needed to develop and interpret indices which are simple enough to be used in the clinical setting to guide the clinician towards effective and safe ventilator management.


    • 1 December 2010
      • Vol. 76  (12) , 1024-35

    Regional intratidal gas distribution in acute lung injury and acute respiratory distress syndrome assessed by electric impedance tomography.

    by K Lowhagen, S Lundin, O Stenqvist

    Regional tidal volume distribution and end-expiratory lung volume (EELV) distribution in patients with acute lung injury and acute respiratory distress syndrome (ALI, ARDS) have previously been investigated using computed tomograpy and electric impedance tomography (EIT). In the present study, we utilized the high temporal resolution of EIT to assess intratidal gas distribution. Sixteen ventilator patients with ALI/ARDS were studied. EIT was used for analysis of intertidal, intratidal and EELV regional distribution. Intratidal regional gas distribution (ITV) was analyzed by dividing the regional tidal impedance signal into eight iso-volume parts. Alveolar pressure/volume curves during ongoing ventilation and volume-dependent compliance during the initial inspiration (Cini) were calculated. A low-pressure (~32 cm H2O) recruitment maneuver and a decremental PEEPtrial were implemented. The increase in EELV was preferentially distributed to non-dependent lung regions. The intratidal gas distribution pattern was similar to the tidal volume distribution following increased PEEP; non-dependent distribution decreased and dependent distribution increased during inspiration. Cini increased, indicating successful recruitment. The distribution varied widely among individual patients. In one patient with a low EELV, the ITV pattern showed that non-dependent distribution increased and dependent distribution decreased. This coincided with minimal improvement in volume-dependent compliance. This patient probably needed higher recruitment pressure. In one patient with a high baseline EELV, there was very little change in regional ITV, and non-dependent Cini decreased. This was probably a patient with low potential recruitability, who required only moderate PEEP. On-line intratidal gas distribution monitoring offers additional information on recruitability and optimal PEEP.


  • Reply

    by H. Odenstedt, O. Stenqvist, S. Lundin

    • 1 February 2002
      • Vol. 46  (2) , 152-9

    Clinical evaluation of a partial CO2 rebreathing technique for cardiac output monitoring in critically ill patients.

    by H Odenstedt, O Stenqvist, S Lundin

    Monitoring central hemodynamics is essential in critically ill patients and less invasive techniques are needed. In this study, the clinical and technical performance of a new non-invasive cardiac output monitor (NICO) based on partial CO2 rebreathing technique and a modified Fick equation were evaluated. The various sources of possible errors in measurement of cardiac output (CO), carbon dioxide production (VCO2) and pulmonary shunt were also assessed. Simultaneous measurements of CO with partial CO2 rebreathing technique (CO(nico)) and thermodilution (CO(td)) were performed in 15 patients during major surgery or in the ICU. Pulmonary shunt was estimated from this device and compared to values obtained by standard shunt formula. The accuracy of VCO2 measurements was assessed in a mechanical lung model. A good correlation was found between CO(nico) and CO(td) (r = 0.96, within-subject correlation r = 0.88) with a small underestimation of cardiac output by the NICO of 0.04 L/min, limits of agreement (+/- 2 SD) being - 1.68 and 1.76 L/min. In hemodynamic unstable patients the method closely tracked changes in CO. Pulmonary shunt was underestimated by approximately 11%-units compared to standard shunt calculations using arterial and mixed venous blood gases. We also observed an underestimation in VCO2 measurements. Clinical evaluation shows that partial CO2 rebreathing technique provides a useful and accurate non-invasive estimate of cardiac output. Although this technique cannot fully replace the pulmonary artery catheter, it may be used to monitor central hemodynamics in a large number of critically ill patients.


    • 21 November 2001
      • Vol. 98  (47) , 5386, 5389-90

    [Is the abolition of pulmonary artery catheterization use evidence-based?].

    by O Stenqvist, S Lundin

  • Reply

    by S. Karason, S. Sondergaard, S. Lundin, J. Wiklund, O. Stenqvist


  • Descending aortic blood flow and cardiac output: A clinical and experimental study of continuous oesophageal echo‐Doppler flowmetry

    by H. Odenstedt, A. Åneman, Y. Oi, M. Svensson, O. Stenqvist, S. Lundin

    Background: Several studies have demonstrated that perioperative optimisation of oxygen delivery and haemodynamics can reduce mortality and morbidity for high‐risk surgical patients. To optimise cardiac output, reliable, continuous and “less invasive” methods for measuring cardiac output are urgently needed. Methods: Eight landrace pigs were studied during experimental repeated cardiac tamponade and 14 patients during liver transplantation. Aortic blood flow was measured by using transoesophageal echo‐Doppler technique. A total of 91 paired measurements of aortic blood flow and cardiac output with different techniques were performed in the pigs and 124 paired measurements in the patients. Results: Transoesophageal echo‐Doppler did provide continuous real‐time monitoring of the rapid and dramatic haemodynamic changes occurring during cardiac tamponade and during liver transplantation, while only intermittent information was obtained from the bolus thermodilution technique. Changes in haemodynamics were more difficult to detect with the “continual” cardiac output thermodilution technique. Changes in aortic blood flow closely followed changes in cardiac output determined by the bolus thermodilution technique both in pigs (r=0.89) and in patients (r=0.80). In patients, aortic blood flow constituted about 70% of cardiac output determined by the bolus thermodilution technique. Conclusions: A combined echo‐Doppler technique can be valuable for continuous monitoring of haemodynamic changes in the perioperative setting, and changes in aortic blood flow agree well with corresponding changes in cardiac output intermittently obtained by thermodilution cardiac output measurements. With the combined echo‐Doppler technique a proper position of the Doppler beam is greatly facilitated by the M‐mode echo visualisation of the aortic wall and aortic cross‐sectional area is continuously measured.