Niels Allert
Research Subjects
Niels Allert has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
Hans Karbe
Neurological Rehabilitation Center Godeshoehe, Bonn, Germany
5 shared publicationsVolker Sturm
Department of Stereotaxy and Functional Neurosurgery, University Hospital Cologne, Cologne, Germany
3 shared publicationsAlexandra Lindlau
Neurological Rehabilitation Center Godeshoehe, Waldstrasse 2-10, D-53177, Bonn, Germany
2 shared publicationsBrit Meike Nolden
Neurological Rehabilitation Center Godeshoehe, Bonn, Germany
2 shared publicationsDaniela Kelm
Neurological Rehabilitation Center Godeshoehe
2 shared publicationsEgle Jusciute
Neurological Rehabilitation Center Godeshoehe, Bonn, Germany
2 shared publications
Latest Publications
- 7 February 2020
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 162 (5) , 1077-1079
DBS dysfunction mimicking transient ischemic attacks—a case report
We report on a patient with thalamic deep brain stimulation (DBS) for essential tremor who was admitted to a stroke unit with transient vertigo, dysarthria, and gait disturbance. Transient ischemic attacks were assumed but fluctuating neurological symptoms persisted until presentation to a DBS center. Here, unstable high monopolar impedances of the right-hemispheric electrode contacts were detected. Surgical revision revealed a fracture of the pocket adaptor connecting this electrode to the impulse generator. Replacement resulted in stable impedances and remitted the transient neurological symptoms. Emergency and stroke doctors should be aware of neurological symptoms induced by technical dysfunctions in DBS.
- 7 February 2020
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 162 (5) , 1077-1079
DBS dysfunction mimicking transient ischemic attacks—a case report
We report on a patient with thalamic deep brain stimulation (DBS) for essential tremor who was admitted to a stroke unit with transient vertigo, dysarthria, and gait disturbance. Transient ischemic attacks were assumed but fluctuating neurological symptoms persisted until presentation to a DBS center. Here, unstable high monopolar impedances of the right-hemispheric electrode contacts were detected. Surgical revision revealed a fracture of the pocket adaptor connecting this electrode to the impulse generator. Replacement resulted in stable impedances and remitted the transient neurological symptoms. Emergency and stroke doctors should be aware of neurological symptoms induced by technical dysfunctions in DBS.
- 17 August 2018
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 160 (12) , 2485-2488
Unstable impedance of a single electrode contact resulting in loss of DBS therapy—a case report
Open and short circuits of electrode contacts are important technical dysfunctions of DBS. Here, we report on another type of dysfunction restricted to a single electrode contact: impedance instability within regular absolute values. After 9-year subthalamic DBS, a Parkinson patient developed unilateral motor symptoms and intermittent dysaesthesia due to impedance instability of the active contact. DBS efficacy could be restored without surgical revision by activation of the neighboring contact. During 3-year-follow-up, impedances of the dysfunctional contact varied between 1 and 3 kΩ whereas the other three contacts remained stable. Impedance documentation is crucial to identify such dysfunctions.
- 17 August 2018
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 160 (12) , 2485-2488
Unstable impedance of a single electrode contact resulting in loss of DBS therapy—a case report
Open and short circuits of electrode contacts are important technical dysfunctions of DBS. Here, we report on another type of dysfunction restricted to a single electrode contact: impedance instability within regular absolute values. After 9-year subthalamic DBS, a Parkinson patient developed unilateral motor symptoms and intermittent dysaesthesia due to impedance instability of the active contact. DBS efficacy could be restored without surgical revision by activation of the neighboring contact. During 3-year-follow-up, impedances of the dysfunctional contact varied between 1 and 3 kΩ whereas the other three contacts remained stable. Impedance documentation is crucial to identify such dysfunctions.
- 1 August 2018
- Published by Elsevier in Neuromodulation: Technology at the Neural Interface
- Vol. 21 (6) , 562-567
Long-Term Stability of Short Circuits in Deep Brain Stimulation
- 1 August 2018
- Published by Elsevier in Neuromodulation: Technology at the Neural Interface
- Vol. 21 (6) , 562-567
Long-Term Stability of Short Circuits in Deep Brain Stimulation
- 27 April 2018
- Published by Elsevier in Neuromodulation: Technology at the Neural Interface
- Vol. 21 (6) , 568-573
DBS Electrodes With Single Disconnected Contacts: Long-Term Observation and Implications for the Management
- 27 April 2018
- Published by Elsevier in Neuromodulation: Technology at the Neural Interface
- Vol. 21 (6) , 568-573
DBS Electrodes With Single Disconnected Contacts: Long-Term Observation and Implications for the Management
- 1 March 2018
- Published by Elsevier in Clinical Neurophysiology
- Vol. 129 (3) , 592-601
Postoperative rehabilitation after deep brain stimulation surgery for movement disorders
- 1 March 2018
- Published by Elsevier in Clinical Neurophysiology
- Vol. 129 (3) , 592-601
Postoperative rehabilitation after deep brain stimulation surgery for movement disorders
- 27 January 2017
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 159 (5) , 795-798
Rapid battery depletion and loss of therapy due to a short circuit in bipolar DBS for essential tremor
Technical dysfunctions have been reported reducing efficacy of deep brain stimulation (DBS). Here, we report on an essential-tremor patient in whom a short circuit in bipolar DBS resulted not only in unilateral loss of therapy but also in high current flow and thereby rapid decline of the impulse-generator battery voltage from 2.83 V a week before the event to 2.54 V, indicating the need for an impulse-generator replacement. Immediate re-programming restored therapeutic efficacy. Moreover, the reduction in current flow allowed the battery voltage to recover without immediate surgical intervention to 2.81 V a week later.
- 27 January 2017
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 159 (5) , 795-798
Rapid battery depletion and loss of therapy due to a short circuit in bipolar DBS for essential tremor
Technical dysfunctions have been reported reducing efficacy of deep brain stimulation (DBS). Here, we report on an essential-tremor patient in whom a short circuit in bipolar DBS resulted not only in unilateral loss of therapy but also in high current flow and thereby rapid decline of the impulse-generator battery voltage from 2.83 V a week before the event to 2.54 V, indicating the need for an impulse-generator replacement. Immediate re-programming restored therapeutic efficacy. Moreover, the reduction in current flow allowed the battery voltage to recover without immediate surgical intervention to 2.81 V a week later.
- 1 November 2016
- Published by Elsevier in Brain Stimulation
- Vol. 9 (6) , 950-951
Short Circuit in Deep Brain Stimulation for Parkinson's Disease Mimicking Stroke
- 1 November 2016
- Published by Elsevier in Brain Stimulation
- Vol. 9 (6) , 950-951
Short Circuit in Deep Brain Stimulation for Parkinson's Disease Mimicking Stroke
- Open Access
- 29 September 2016
- Published by Springer Nature in Trials
- Vol. 17 (1) , 1-8
Deep brain stimulation of the posterior subthalamic area and the thalamus in patients with essential tremor: study protocol for a randomized controlled pilot trial
Deep brain stimulation (DBS) of the ventral intermediate nucleus (VIM) of the thalamus is effective in medication refractory essential tremor (ET). In recent years, evidence has accumulated that the region ventral to the VIM, the posterior subthalamic area (PSA), might be an equally or even more effective target for electrode implantation. However, this evidence is primarily based on case series, cross-sectional observations, and retrospective data. A prospective crossover pilot study investigating the effects of PSA stimulation in medication refractory ET patients was designed. In this study, bilateral electrodes are implanted such that at least one of the electrode contacts is located in the PSA and VIM, respectively. This implantation approach allows (1) a prospective double-blind investigation of the effects of PSA stimulation compared to baseline, as well as (2) a crossover comparison between VIM and PSA stimulation with respect to tremor suppression and side effect profiles. The results of this double-blinded, prospective study will allow a better understanding of the effects and side effects of PSA compared to VIM-DBS in patients with ET. German Clinical Trials Register: DRKS00004235 . Registered on 4 July 2012.
- 29 September 2016
- Published by Springer Nature in Trials
- Vol. 17 (1) , 1-8
Open AccessDeep brain stimulation of the posterior subthalamic area and the thalamus in patients with essential tremor: study protocol for a randomized controlled pilot trial
Deep brain stimulation (DBS) of the ventral intermediate nucleus (VIM) of the thalamus is effective in medication refractory essential tremor (ET). In recent years, evidence has accumulated that the region ventral to the VIM, the posterior subthalamic area (PSA), might be an equally or even more effective target for electrode implantation. However, this evidence is primarily based on case series, cross-sectional observations, and retrospective data. A prospective crossover pilot study investigating the effects of PSA stimulation in medication refractory ET patients was designed. In this study, bilateral electrodes are implanted such that at least one of the electrode contacts is located in the PSA and VIM, respectively. This implantation approach allows (1) a prospective double-blind investigation of the effects of PSA stimulation compared to baseline, as well as (2) a crossover comparison between VIM and PSA stimulation with respect to tremor suppression and side effect profiles. The results of this double-blinded, prospective study will allow a better understanding of the effects and side effects of PSA compared to VIM-DBS in patients with ET. German Clinical Trials Register: DRKS00004235 . Registered on 4 July 2012.
- 19 May 2016
- Published by Springer Nature in Journal of Neural Transmission
- Vol. 123 (6) , 631-635
Arachnophobia alleviated by subthalamic nucleus stimulation for Parkinson’s disease
We report on a Parkinson patient with motor fluctuations and dyskinesias in whom deep brain stimulation (DBS) of the subthalamic nucleus (STN) not only improved motor symptoms but also pre-existing arachnophobia. Arachnophobia had been unchanged by the course of Parkinson’s disease but rapidly improved with STN-DBS. Both, motor effects and the improvement of arachnophobia were stable during 2 years follow-up. To our knowledge this is the first report on STN stimulation effects on a specific phobia.
- 19 May 2016
- Published by Springer Nature in Journal of Neural Transmission
- Vol. 123 (6) , 631-635
Arachnophobia alleviated by subthalamic nucleus stimulation for Parkinson’s disease
We report on a Parkinson patient with motor fluctuations and dyskinesias in whom deep brain stimulation (DBS) of the subthalamic nucleus (STN) not only improved motor symptoms but also pre-existing arachnophobia. Arachnophobia had been unchanged by the course of Parkinson’s disease but rapidly improved with STN-DBS. Both, motor effects and the improvement of arachnophobia were stable during 2 years follow-up. To our knowledge this is the first report on STN stimulation effects on a specific phobia.
- 6 December 2011
- Published by Springer Nature in Journal of Neurology
- Vol. 259 (6) , 1244-1246
Failure of long-term subthalamic nucleus stimulation corrected by additional pallidal stimulation in a patient with Parkinson’s disease
- 6 December 2011
- Published by Springer Nature in Journal of Neurology
- Vol. 259 (6) , 1244-1246
Failure of long-term subthalamic nucleus stimulation corrected by additional pallidal stimulation in a patient with Parkinson’s disease