Osamu Niwa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Osamu Niwa has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Dai Kato
Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki 305-8566, Japan
14 shared publications - Ryoji Kurita
Faculty of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
12 shared publications Shigeru Hirono
JSW-Afty Corporation
11 shared publicationsAkio Ueda
National Institute of Advanced Industrial Science and Technology, 1-1-1 Higashi, Tsukuba, Ibaraki 305-8566, Japan
8 shared publicationsTomoyuki Kamata
National Institute of Advanced Industrial Science and Technology (AIST) , 1-1-1 Higashi, Tsukuba 305-8566, Japan
7 shared publications- Yukari Sato
National Institute of Advanced Industrial Science and Technology
6 shared publications
Latest Publications
- Open Access
- 1 January 2017
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 66 (1) , 1-10
Protein Sensing Based on Cross-reactive Optical Fingerprinting
タンパク質を検出するための分子は"選択的"であるほど良いというのが一般的な理解である.しかし,近年,従来とは異なる発想にもとづく「交差反応的光学フィンガープリンティング法(COF法)」というタンパク質センシング法が提案された.この方法は,従来,タンパク質の検出にとってマイナスと捉えられてきた"交差反応的"な相互作用を利用する.本稿では,はじめにCOF法を概説し,その後,COF法を構築するために酵素/イオン性高分子間で形成したポリイオン複合体(PIC)を利用した著者らのアプローチを紹介する.このPICを用いるCOF法では,異なる性質をもつ複数のPICをタンパク質と相互作用させることにより,タンパク質の物性を反映した"酵素活性のフィンガープリント"を得る.フィンガープリントを統計的に解析することで,ヒト血漿(しょう)タンパク質やアルブミンホモログの高精度な識別を実現してきた.またCOF法は,1種類のタンパク質を含む溶液だけでなく,複雑なタンパク質混合液の組成の識別にも適用することができる.この特長をいかし,著者らは,細胞分泌タンパク質の組成の識別にCOF法を応用した"セクレトームフィンガープリンティング法"を開発した.これにより,がん細胞の種類や幹細胞の分化系譜を,非破壊的かつマーカー分子に頼らずに同定できることを実証した.
- 1 January 2017
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 66 (1) , 1-10
Open AccessProtein Sensing Based on Cross-reactive Optical Fingerprinting
タンパク質を検出するための分子は"選択的"であるほど良いというのが一般的な理解である.しかし,近年,従来とは異なる発想にもとづく「交差反応的光学フィンガープリンティング法(COF法)」というタンパク質センシング法が提案された.この方法は,従来,タンパク質の検出にとってマイナスと捉えられてきた"交差反応的"な相互作用を利用する.本稿では,はじめにCOF法を概説し,その後,COF法を構築するために酵素/イオン性高分子間で形成したポリイオン複合体(PIC)を利用した著者らのアプローチを紹介する.このPICを用いるCOF法では,異なる性質をもつ複数のPICをタンパク質と相互作用させることにより,タンパク質の物性を反映した"酵素活性のフィンガープリント"を得る.フィンガープリントを統計的に解析することで,ヒト血漿(しょう)タンパク質やアルブミンホモログの高精度な識別を実現してきた.またCOF法は,1種類のタンパク質を含む溶液だけでなく,複雑なタンパク質混合液の組成の識別にも適用することができる.この特長をいかし,著者らは,細胞分泌タンパク質の組成の識別にCOF法を応用した"セクレトームフィンガープリンティング法"を開発した.これにより,がん細胞の種類や幹細胞の分化系譜を,非破壊的かつマーカー分子に頼らずに同定できることを実証した.
- 12 February 2016
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (5) , 2944-2951
Au Nanoparticle-Embedded Carbon Films for Electrochemical As3+ Detection with High Sensitivity and Stability
Au nanoparticle (AuNP)-embedded carbon films were formed with a one-step reproducible process by using unbalanced magnetron (UBM) cosputtering to make it possible to detect As3+ in water. The sputtered Au components formed NPs (typically 5 nm in diameter) spontaneously in the carbon films, owing to the poor intermiscibility of Au with carbon. The surface contents of embedded AuNPs in the carbon film were widely controllable (Au = 13–21 at %) by regulating the target powers of Au and carbon individually. The obtained film had a flat surface (Ra = 0.1 nm) despite the fact the AuNPs were partially exposed at the surface. By anodic stripping voltammetry (ASV) As3+ detection, a limit of detection of 0.55 ppb and linear dynamic range of 1–100 ppb were obtained with our electrode. These values meet the requirements imposed by international regulation. Moreover, our electrode structure realized good electrode stability for repetitive ASV measurements (relative standard deviation (RSD) = 11.7%, n = 15) because the partially embedded AuNP structures prevented the AuNPs from detaching from the surface. This result was achieved by the electrode recovery only by a potential scan from 0.1 to 1.5 V. Our electrodes can be stocked for a long time (2 years) with maintaining the electrode performance, which is very attractive for practical electrode. Selectivity test by using Tsukuba tap water added 10 ppb As3+ and 1000 ppb Cu2+ was successfully achieved with existence of 0.1 M EDTA (RSD = 2.6%, n = 3). The ASV results with tap water samples agreed well with those by the conventional ICPMS method.
- 12 February 2016
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (5) , 2944-2951
Au Nanoparticle-Embedded Carbon Films for Electrochemical As3+ Detection with High Sensitivity and Stability
Au nanoparticle (AuNP)-embedded carbon films were formed with a one-step reproducible process by using unbalanced magnetron (UBM) cosputtering to make it possible to detect As3+ in water. The sputtered Au components formed NPs (typically 5 nm in diameter) spontaneously in the carbon films, owing to the poor intermiscibility of Au with carbon. The surface contents of embedded AuNPs in the carbon film were widely controllable (Au = 13–21 at %) by regulating the target powers of Au and carbon individually. The obtained film had a flat surface (Ra = 0.1 nm) despite the fact the AuNPs were partially exposed at the surface. By anodic stripping voltammetry (ASV) As3+ detection, a limit of detection of 0.55 ppb and linear dynamic range of 1–100 ppb were obtained with our electrode. These values meet the requirements imposed by international regulation. Moreover, our electrode structure realized good electrode stability for repetitive ASV measurements (relative standard deviation (RSD) = 11.7%, n = 15) because the partially embedded AuNP structures prevented the AuNPs from detaching from the surface. This result was achieved by the electrode recovery only by a potential scan from 0.1 to 1.5 V. Our electrodes can be stocked for a long time (2 years) with maintaining the electrode performance, which is very attractive for practical electrode. Selectivity test by using Tsukuba tap water added 10 ppb As3+ and 1000 ppb Cu2+ was successfully achieved with existence of 0.1 M EDTA (RSD = 2.6%, n = 3). The ASV results with tap water samples agreed well with those by the conventional ICPMS method.
- 27 January 2015
- Published by Springer Nature
- p. 121-136
Nanocarbon Film-Based Electrochemical Detectors and Biosensors
- 27 January 2015
- Published by Springer Nature
- p. 121-136
Nanocarbon Film-Based Electrochemical Detectors and Biosensors
- Open Access
A Label-Free Immunosensor for IgG Based on an Extended-Gate Type Organic Field Effect Transistor
A novel biosensor for immunoglobulin G (IgG) detection based on an extended-gate type organic field effect transistor (OFET) has been developed that possesses an anti-IgG antibody on its extended-gate electrode and can be operated below 3 V. The titration results from the target IgG in the presence of a bovine serum albumin interferent, clearly exhibiting a negative shift in the OFET transfer curve with increasing IgG concentration. This is presumed to be due an interaction between target IgG and the immobilized anti-IgG antibody on the extended-gate electrode. As a result, a linear range from 0 to 10 µg/mL was achieved with a relatively low detection limit of 0.62 µg/mL (=4 nM). We believe that these results open up opportunities for applying extended-gate-type OFETs to immunosensing.
Open AccessA Label-Free Immunosensor for IgG Based on an Extended-Gate Type Organic Field Effect Transistor
A novel biosensor for immunoglobulin G (IgG) detection based on an extended-gate type organic field effect transistor (OFET) has been developed that possesses an anti-IgG antibody on its extended-gate electrode and can be operated below 3 V. The titration results from the target IgG in the presence of a bovine serum albumin interferent, clearly exhibiting a negative shift in the OFET transfer curve with increasing IgG concentration. This is presumed to be due an interaction between target IgG and the immobilized anti-IgG antibody on the extended-gate electrode. As a result, a linear range from 0 to 10 µg/mL was achieved with a relatively low detection limit of 0.62 µg/mL (=4 nM). We believe that these results open up opportunities for applying extended-gate-type OFETs to immunosensing.
- 1 January 2014
- Published by The Surface Finishing Society of Japan in Journal of The Surface Finishing Society of Japan
- Vol. 65 (12) , 628-630
Adhesion Characteristics Evaluation Method for Ultra Thin Films by Nanoindentation
- 1 January 2014
- Published by The Surface Finishing Society of Japan in Journal of The Surface Finishing Society of Japan
- Vol. 65 (12) , 628-630
Adhesion Characteristics Evaluation Method for Ultra Thin Films by Nanoindentation
- 15 October 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (21) , 9996-9999
Cytochrome P450 Modified Polycrystalline Indium Tin Oxide Film as a Drug Metabolizing Electrochemical Biosensor with a Simple Configuration
The development of a biocatalytic electrode consisting of cytochrome P450 (CYP) proteins would be a key technology with which to establish simple drug metabolizing biosensors or screening devices for drug inhibitors. We have successfully detected the direct electron transfer (DET) from a human CYP layer or a CYP microsome adsorbed on a bare indium tin oxide (ITO) film electrode without any modification layers and applied it to drug metabolism evaluation. We compared the electrocatalytic properties of the two ITO films with different surface nanostructures (polycrystalline or amorphous). CYP on polycrystalline ITO film enhanced the electron transfer rate of oxygen reduction about fifteen times more than with amorphous film. The polycrystalline ITO film was a suitable electrode for the adsorption of CYP proteins while maintaining efficient DET and enzymatic activity, probably because of its larger surface area and negatively charged surface. The oxygen reduction current at the polycrystalline ITO film electrodes had increased 3- to 4-fold, specifically coupled with the oxidation of drugs (testosterone and quinidine) by the monooxygenase activity of CYP. In contrast, the oxygen reduction current completely disappeared in the presence of the CYP inhibitor (ketoconazole). Similar results could be obtained from the CYP microsome with sufficiently clear responses. These results indicate that the CYP modified polycrystalline ITO electrode offers the potential for electrochemically evaluating CYP activity for drug metabolism with a simple configuration.
- 15 October 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (21) , 9996-9999
Cytochrome P450 Modified Polycrystalline Indium Tin Oxide Film as a Drug Metabolizing Electrochemical Biosensor with a Simple Configuration
The development of a biocatalytic electrode consisting of cytochrome P450 (CYP) proteins would be a key technology with which to establish simple drug metabolizing biosensors or screening devices for drug inhibitors. We have successfully detected the direct electron transfer (DET) from a human CYP layer or a CYP microsome adsorbed on a bare indium tin oxide (ITO) film electrode without any modification layers and applied it to drug metabolism evaluation. We compared the electrocatalytic properties of the two ITO films with different surface nanostructures (polycrystalline or amorphous). CYP on polycrystalline ITO film enhanced the electron transfer rate of oxygen reduction about fifteen times more than with amorphous film. The polycrystalline ITO film was a suitable electrode for the adsorption of CYP proteins while maintaining efficient DET and enzymatic activity, probably because of its larger surface area and negatively charged surface. The oxygen reduction current at the polycrystalline ITO film electrodes had increased 3- to 4-fold, specifically coupled with the oxidation of drugs (testosterone and quinidine) by the monooxygenase activity of CYP. In contrast, the oxygen reduction current completely disappeared in the presence of the CYP inhibitor (ketoconazole). Similar results could be obtained from the CYP microsome with sufficiently clear responses. These results indicate that the CYP modified polycrystalline ITO electrode offers the potential for electrochemically evaluating CYP activity for drug metabolism with a simple configuration.
- 1 October 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (20) , 9845-9851
Structure and Electrochemical Performance of Nitrogen-Doped Carbon Film Formed by Electron Cyclotron Resonance Sputtering
A nitrogen-doped nanocarbon film electrode with mixed sp2 and sp3 bonds formed using the electron cyclotron resonance (ECR) sputtering method was studied with respect to the relationship between nitrogen concentration and electrochemical performance. The film (N-ECR) has a nanocrystalline structure, and the sp3 content increases with increasing nitrogen concentration unlike the recently reported nitrogen-containing tetrahedral amorphous carbon film.1 The film has a very smooth surface with an average roughness of 0.1 to 0.2 nm, which is almost independent of nitrogen concentration. In contrast, the ratio of nitrogen-containing graphite-like bonding is high at low nitrogen concentrations, and then pyridine-like bonding increases as the nitrogen concentration increases. These variations in the chemical structures and the sp2 and sp3 content greatly change the electrochemical performance. The N-ECR electrode shows a wider potential window (∼3.8 V) than a pure nanocarbon electrode (∼3.1 V) due to its higher sp3 content. The N-ECR electrode (N = 9.0 at. %) shows improved electrochemical activity because the lowest peak separation of Fe(CN)63–/4– was observed at this nitrogen concentration. The oxygen and hydrogen peroxide (H2O2) reduction potentials at the N-ECR electrode shifted about 0.3 and 0.15 V, respectively, and the peak height of H2O2 is greatly increased. As a result, a linear relationship was obtained from 0.2 to 17 mM for the reductive current detection of H2O2. The N-ECR electrode also shows better activity for oxidizing certain biomolecules. The oxidation potentials of guanosine and adenosine decreased about 0.1 V, suggesting that the N-ECR electrode is suitable for use as a biosensing platform.
- 1 October 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (20) , 9845-9851
Structure and Electrochemical Performance of Nitrogen-Doped Carbon Film Formed by Electron Cyclotron Resonance Sputtering
A nitrogen-doped nanocarbon film electrode with mixed sp2 and sp3 bonds formed using the electron cyclotron resonance (ECR) sputtering method was studied with respect to the relationship between nitrogen concentration and electrochemical performance. The film (N-ECR) has a nanocrystalline structure, and the sp3 content increases with increasing nitrogen concentration unlike the recently reported nitrogen-containing tetrahedral amorphous carbon film.1 The film has a very smooth surface with an average roughness of 0.1 to 0.2 nm, which is almost independent of nitrogen concentration. In contrast, the ratio of nitrogen-containing graphite-like bonding is high at low nitrogen concentrations, and then pyridine-like bonding increases as the nitrogen concentration increases. These variations in the chemical structures and the sp2 and sp3 content greatly change the electrochemical performance. The N-ECR electrode shows a wider potential window (∼3.8 V) than a pure nanocarbon electrode (∼3.1 V) due to its higher sp3 content. The N-ECR electrode (N = 9.0 at. %) shows improved electrochemical activity because the lowest peak separation of Fe(CN)63–/4– was observed at this nitrogen concentration. The oxygen and hydrogen peroxide (H2O2) reduction potentials at the N-ECR electrode shifted about 0.3 and 0.15 V, respectively, and the peak height of H2O2 is greatly increased. As a result, a linear relationship was obtained from 0.2 to 17 mM for the reductive current detection of H2O2. The N-ECR electrode also shows better activity for oxidizing certain biomolecules. The oxidation potentials of guanosine and adenosine decreased about 0.1 V, suggesting that the N-ECR electrode is suitable for use as a biosensing platform.
- 15 August 2013
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 138 (21) , 6463-6468
Human cytochrome P450 3A4 and a carbon nanofiber modified film electrode as a platform for the simple evaluation of drug metabolism and inhibition reactions
Electrochemical biosensors consisting of cytochrome P450 enzyme modified electrodes have been developed to provide a simple method for screening the metabolism of a drug and its inhibitor. Here, we report a very simple electrochemically driven biosensor for detecting drug metabolism and its inhibition based on cytochrome P450 3A4 (CYP3A4) and a carbon nanofiber (CNF) modified film electrode without any other modified layers such as mediator films. Direct electron transfer (DET) between CYP3A4 and CNFs was observed at a formal potential of −0.302 V. The electrocatalytic reduction current increased with the addition of drugs including testosterone and quinidine. In contrast, the reduction current was greatly suppressed in the presence of ketoconazole, which is a CYP3A4 inhibitor. CNFs with high conductivity, a large surface area and sufficient edge planes provide a suitable microenvironment for achieving excellent DET and biocatalysis properties, which could not be observed when we used other carbon materials such as carbon nanotube (CNT) and carbon black (CB) modified electrodes, indicating that our system is promising as a new bioelectronic platform for electrochemical biosensing.
- 15 August 2013
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 138 (21) , 6463-6468
Human cytochrome P450 3A4 and a carbon nanofiber modified film electrode as a platform for the simple evaluation of drug metabolism and inhibition reactions
Electrochemical biosensors consisting of cytochrome P450 enzyme modified electrodes have been developed to provide a simple method for screening the metabolism of a drug and its inhibitor. Here, we report a very simple electrochemically driven biosensor for detecting drug metabolism and its inhibition based on cytochrome P450 3A4 (CYP3A4) and a carbon nanofiber (CNF) modified film electrode without any other modified layers such as mediator films. Direct electron transfer (DET) between CYP3A4 and CNFs was observed at a formal potential of −0.302 V. The electrocatalytic reduction current increased with the addition of drugs including testosterone and quinidine. In contrast, the reduction current was greatly suppressed in the presence of ketoconazole, which is a CYP3A4 inhibitor. CNFs with high conductivity, a large surface area and sufficient edge planes provide a suitable microenvironment for achieving excellent DET and biocatalysis properties, which could not be observed when we used other carbon materials such as carbon nanotube (CNT) and carbon black (CB) modified electrodes, indicating that our system is promising as a new bioelectronic platform for electrochemical biosensing.
- 3 December 2012
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 84 (24) , 10607-10613
Evaluation of Electrokinetic Parameters for All DNA Bases with Sputter Deposited Nanocarbon Film Electrode
The electrokinetic parameters of all the DNA bases were evaluated using a sputter-deposited nanocarbon film electrode. It is very difficult to evaluate the electrokinetic parameters of DNA bases with conventional electrodes, and particularly those of pyrimidine bases, owing to their high oxidation potentials. Nanocarbon film formed by employing an electron cyclotron resonance sputtering method consists of a nanocrystalline sp2 and sp3 mixed bond structure that exhibits a sufficient potential window, very low adsorption of DNA molecules, and sufficient electrochemical activity to oxidize all DNA bases. A precise evaluation of rate constants (k) between all the bases and the electrodes is achieved for the first time by obtaining rotating disc electrode measurements with our nanocarbon film electrode. We found that the k value of each DNA base was dominantly dependent on the surface oxygen-containing group of the nanocarbon film electrode, which was controlled by electrochemical pretreatment. In fact, the treated electrode exhibited optimum k values for all the mononucleotides, namely, 2.0 × 10–2, 2.5 × 10–1, 2.6 × 10–3, and 5.6 × 10–3 cm s–1 for GMP, AMP, TMP, and CMP, respectively. The k value of AMP was sufficiently enhanced by up to 33 times with electrochemical pretreatment. We also found the k values for pyrimidine bases to be much lower than those of purine bases although there was no large difference between their diffusion coefficient constants. Moreover, the theoretical oxidation potential values for all the bases coincided with those obtained in electrochemical experiments using our nanocarbon film electrode.
- 3 December 2012
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 84 (24) , 10607-10613
Evaluation of Electrokinetic Parameters for All DNA Bases with Sputter Deposited Nanocarbon Film Electrode
The electrokinetic parameters of all the DNA bases were evaluated using a sputter-deposited nanocarbon film electrode. It is very difficult to evaluate the electrokinetic parameters of DNA bases with conventional electrodes, and particularly those of pyrimidine bases, owing to their high oxidation potentials. Nanocarbon film formed by employing an electron cyclotron resonance sputtering method consists of a nanocrystalline sp2 and sp3 mixed bond structure that exhibits a sufficient potential window, very low adsorption of DNA molecules, and sufficient electrochemical activity to oxidize all DNA bases. A precise evaluation of rate constants (k) between all the bases and the electrodes is achieved for the first time by obtaining rotating disc electrode measurements with our nanocarbon film electrode. We found that the k value of each DNA base was dominantly dependent on the surface oxygen-containing group of the nanocarbon film electrode, which was controlled by electrochemical pretreatment. In fact, the treated electrode exhibited optimum k values for all the mononucleotides, namely, 2.0 × 10–2, 2.5 × 10–1, 2.6 × 10–3, and 5.6 × 10–3 cm s–1 for GMP, AMP, TMP, and CMP, respectively. The k value of AMP was sufficiently enhanced by up to 33 times with electrochemical pretreatment. We also found the k values for pyrimidine bases to be much lower than those of purine bases although there was no large difference between their diffusion coefficient constants. Moreover, the theoretical oxidation potential values for all the bases coincided with those obtained in electrochemical experiments using our nanocarbon film electrode.
- 1 December 2012
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 51 (12) , 125602
The Structure and Bonding State for Fullerene-Like Carbon Nitride Films with High Hardness Formed by Electron Cyclotron Resonance Plasma Sputtering
We studied pure carbon films and carbon nitride (CN) films by using electron cyclotron resonance (ECR) sputtering. The main feature of this method is high density ion irradiation during deposition, which enables the pure carbon films to have fullerene-like (FL) structures without nitrogen incorporation. Furthermore, without substrate heating, the ECR sputtered CN films exhibited an enhanced FL microstructure and hardness comparable to that of diamond at intermediate nitrogen concentration. This microstructure consisted of bent and cross-linked graphene sheets where layered areas remarkably decreased due to increased sp3 bonding. Under high nitrogen concentration conditions, the CN films demonstrated extremely low hardness because nitrile bonding not only decreased the covalent-bonded two-dimensional hexagonal network but also annihilated the bonding there. By evaluating lattice images obtained by transmission electron microscopy and the bonding state measured by X-ray photoelectron spectroscopy, we classified the ECR sputtered CN films and offered phase diagram and structure zone diagram.
- 1 December 2012
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 51 (12) , 125602
The Structure and Bonding State for Fullerene-Like Carbon Nitride Films with High Hardness Formed by Electron Cyclotron Resonance Plasma Sputtering
We studied pure carbon films and carbon nitride (CN) films by using electron cyclotron resonance (ECR) sputtering. The main feature of this method is high density ion irradiation during deposition, which enables the pure carbon films to have fullerene-like (FL) structures without nitrogen incorporation. Furthermore, without substrate heating, the ECR sputtered CN films exhibited an enhanced FL microstructure and hardness comparable to that of diamond at intermediate nitrogen concentration. This microstructure consisted of bent and cross-linked graphene sheets where layered areas remarkably decreased due to increased sp3 bonding. Under high nitrogen concentration conditions, the CN films demonstrated extremely low hardness because nitrile bonding not only decreased the covalent-bonded two-dimensional hexagonal network but also annihilated the bonding there. By evaluating lattice images obtained by transmission electron microscopy and the bonding state measured by X-ray photoelectron spectroscopy, we classified the ECR sputtered CN films and offered phase diagram and structure zone diagram.