  • Combined Evaluation of Frequency Doubling Technology Perimetry and Scanning Laser Ophthalmoscopy for Glaucoma Detection Using Automated Classification

    by Folkert K. Horn, Robert Lämmer, Christian Y. Mardin, Anselm G. Jünemann, Georg Michelson, Berthold Lausen, Werner Adler

    Purpose To develop a diagnostic setup with classification rules for combined analysis of morphology [Heidelberg Retina Tomograph (HRT)] and function [frequency doubling technology (FDT) perimetry] measurements. Methods We used 2 independent case-control studies from the Erlangen eye department as learning and test data for automated classification using random forests. One eye of 334 open angle glaucoma patients and 254 controls entered the study. All individuals underwent HRT scanning tomography of the optic disc, FDT screening, conventional perimetry, and evaluation of fundus photographs. Random forests were learned on individuals of the Erlangen glaucoma registry (102 preperimetric patients, 130 perimetric patients, 161 controls). The classification performances of random forests and built-in classifiers were examined by receiver operator characteristic analysis on an independent second cohort of individuals (47 preperimetric patients, 55 perimetric patients, 93 controls). Results HRT measurements had a higher diagnostic power for early glaucomas and FDT perimetry for glaucoma patients with visual field loss. A combination of all parameters using automated classification was superior to single tests in comparison to the diagnostic instrument with the higher diagnostic power in the respective group. Highest sensitivities at a fixed specificity (95%) in the patients of the present test population were: HRT=32%, FDT=19%, combined analysis=47% in preperimetric patients and HRT=76%, FDT=89%, combined analysis=96% in perimetric patients. Conclusions The feasibility of machine learning for medical diagnostic assistance could be demonstrated in patients from 2 independent study populations. A predictive model using automated classification is able to combine the advantages of morphology and function, resulting in a higher diagnostic power for glaucoma detection.


  • The photopic negative response of the blue-on-yellow flash-electroretinogram in glaucomas and normal subjects

    by Nina Wakili, Folkert K. Horn, Anselm G. Jünemann, Nhung X. Nguyen, Christian Y. Mardin, Matthias Korth, Jan Kremers

    The photopic negative response of the flash-electroretinogram driven by the middle- and long-wavelength cones has been shown to be reduced in non-human primates with experimental glaucoma and in human patients with glaucoma. The photopic negative response for the blue-sensitive response has been studied using a blue-green silent-substitution-technique on a red background. The aim of this study was to re-evaluate the value of the photopic negative response of the blue-sensitive pathway in glaucoma using a conventional flash-electroretinogram. In 37 eyes of 37 controls (age: 53 ± 13.6 years) and 37 eyes of 37 patients with open-angle glaucoma of different perimetric visual field defects (age: 58.3 ± 10 years; MD: 11.7 ± 6.7 dB) of the Erlangen glaucoma registry Ganzfeld flash-electroretinograms (LKC, UTAS 3000) were recorded using blue Xenon-flashes of increasing photopic luminance (0.013, 0.018, 0.030, and 0.052 cd s/m2; 440 nm) on a bright yellow background (238 cd/m2; 550 nm) after 2 min of light adaptation. Amplitudes and implicit times of the photopic negative response and of L&M-cone- and S-cone-driven b-waves were compared between glaucomas and controls for all flash energies (unpaired t-test). The amplitudes of the photopic negative response were significantly reduced in glaucoma patients for all flash energies (P < 0.001). The implicit times of L&M-cone-driven b-wave (0.013, 0.018, 0.030, and 0.052 cd s/m2) and S-cone-driven b-wave (0.030 and 0.052 cd s/m2) were significantly prolonged in glaucoma patients (P < 0.05). The changes in these implicit times, however, are very small (1.5 ms or less). The other measures did not differ significantly. The amplitude of the photopic negative response and the implicit times of the L&M-cone and S-cone b-wave in the same responses of the blue-on-yellow flash-electroretinogram are potentially useful in the evaluation of inner-retinal function in glaucoma.


  • Measuring contrast sensitivity in normal subjects with OPTEC® 6500: influence of age and glare

    by Bettina Hohberger, Robert Laemmer, Werner Adler, Anselm G. M. Juenemann, Folkert K. Horn

    The purpose of this study was to develop age-related curves for contrast sensitivity (CS) in normal subjects under day and night conditions with and without glare.


  • Long-term Reproducibility of Screening for Glaucoma With FDT-Perimetry

    by Folkert K. Horn, Barbara Link, Christian Y. Mardin, Anselm G. Jünemann, Peter Martus

    Aim of this study was to evaluate the long-term reproducibility of frequency doubling technology (FDT) screening procedures. Longitudinal data of 433 eyes of 294 patients with no progression of glaucomatous optic disc atrophy were retrospectively analyzed: 62 control eyes, 184 ocular hypertensive eyes, 104 preperimetric, and 83 perimetric open-angle glaucoma eyes. All subjects had annual tests with the FDT perimeter and a standardized ophthalmologic examination (ie, conventional perimetry, optic disc inspection, tonometry, lens opacity measurement for exclusion of cataract). The present analysis used a published overall screening score with case-wise recalculation of missed localized probability levels. We analyzed long-term variability by correlation analysis, sign tests, and limits of agreement (LoA) as introduced by Altman and Bland. All subjects had at least 2 annual tests. Three hundred twenty-six eyes had 2 annual tests with the C-20 procedure and at least 1 test with the N-30 protocol another year later. One hundred thirty-five eyes had 1 C-20 and 2 annual tests with the N-30 protocol. Analyses of repeated measurements revealed a significant learning effect (P0.6, LoA: ±9). In addition, there was no significant difference between second C-20 and N-30 tests (P>0.5, LoA: −12, 6). The study demonstrates the variability of FDT tests over several years. Longitudinal FDT-results in a clinical study showed a higher reproducibility if the first test was discarded. Reproducibility of screening with the N-30 protocol is comparable to the C-20 procedure if an overall score is considered.


  • Glaucoma Detection With Frequency Doubling Perimetry and Short-wavelength Perimetry

    by Folkert K Horn, Alexander Brenning, Anselm G Jünemann, Berthold Lausen

    The aim of this analysis was to evaluate the diagnostic usefulness of frequency doubling technology (FDT) perimetry and short-wavelength perimetry (SWAP). Moreover, to study a combination of both methods using the machine-learning technique double-bagging, which was recently established in glaucoma research. Forty-three patients with "preperimetric" open-angle glaucoma (glaucomatous optic disc atrophy and no visual field defect in standard perimetry), 26 patients with "perimetric" open angle glaucoma (glaucomatous optic disc atrophy and visual field defect in standard perimetry), and 40 control subjects had FDT screening (protocol: C-20-5) and SWAP (Octopus 101, G2). Criteria for exclusion were color vision abnormalities, media opacities, and an age below 31 years or above 63 years. Data of 1 eye of each patient and control subject entered the statistical evaluation. A point wise evaluation of the diagnostic power of SWAP values was performed to derive spatial patterns of visual field loss. A double-bagging machine-learning algorithm was used to train classification rules on the basis of a combination of FDT scores and nerve fiber related visual field losses in SWAP. The diagnostic power of the classifiers was compared regarding their misclassification error rates and area under the receiver-operating characteristic curve. The combination of FDT perimetry and SWAP yielded better diagnostic results compared with FDT or SWAP separately. The overall estimated misclassification error rate of the combined classifier was 24% compared with 28% for both SWAP and FDT perimetry. Regarding the estimated performance of classifier at high specificities (>80%) in control eyes as measured by the partial area under the receiver-operating characteristic curve, the combination of both instruments is also superior to the individual instruments. A combination of SWAP and FDT perimetry, each targeting different neuronal pathways, may improve early glaucoma detection.


  • Flimmerprovokation im LED-Ganzfeld bei Gesunden und Glaukompatienten

    by F. K. Horn, B. Link, K. Dehne, R. Lämmer, A. G. Jünemann


  • Visual Evoked Potentials of the Blue-Sensitive Pathway Under Cold Provocation in Normals and Glaucomas

    by Folkert K Horn, Georg Michelson, Eckbert Schnitzler, Christian Y Mardin, Matthias Korth, Anselm G Jünemann

    Vascular dysregulation in open-angle glaucomas can be identified by measuring the blood circulation during exposure to cold water. Aim of this study was to find out whether the same cold stimulus would lead to functional changes in the visual evoked potentials (VEP) of the short-sensitive pathway in normals and glaucoma patients. Blue-on-yellow pattern-visual evoked potentials were studied in 22 healthy control persons and 47 patients with primary open-angle glaucoma (25 high-pressure glaucomas, 22 normal pressure glaucomas with clinical signs of vasospastic hyperreactivity). A blue stripe pattern, presented in onset-offset mode on a yellow adaptation light served as the stimulus. Cold provocation was initiated by dipping one hand of the patient into cold water of 3 degrees C to 5 degrees C. The onset amplitudes and peak times were measured without cold exposition as well as two and four minutes after the cold exposition began. In the group of vasospastic glaucoma patients a significant reduction of visual evoked potential-amplitudes was observed during cold provocation (amplitude before ice exposition: 4.17 microV, amplitude following two minutes of ice exposition: 3.52 microV; paired test: P < 0.01). Other subject groups showed no significant amplitude reductions after cold provocation. Peak times of both open-angle glaucoma groups (132.3 +/- 18.7 milliseconds in high pressure, 132.7 +/- 14.5 milliseconds in normal pressure) were significantly increased in comparison to normals (117.4 +/- 8.0 milliseconds). However, no significant influence of the cold provocation on peak times could be found in all groups. Peak times of the blue-on-yellow visual evoked potentials are significantly prolonged in patients with primary open-angle glaucomas. Cold provocation causes a significant amplitude reduction of the blue-on-yellow visual evoked potential in the present normal-pressure glaucoma patients and reflects vascular dysregulation in patients with vasospastic hyperreactivity.


  • Association Between Localized Visual Field Losses and Thickness Deviation of the Nerve Fiber Layer in Glaucoma

    by Folkert K Horn, Christian Y Mardin, Arne Viestenz, Anselm G Jünemann

    To perform a correlation between morphology and function by studying local perimetric field losses and thickness reduction of the nerve layer in corresponding areas. Forty-seven patients with "preperimetric" open-angle glaucoma, 95 patients with "perimetric" open-angle glaucoma, and 75 control subjects had perimetric (Octopus) and polarimetric measurements. Criteria for exclusion: optic discs larger than 4 mm, media opacities, polarimetric hourglass pattern in the macular image. Thickness values of the retinal nerve fiber layer were determined in 14 upper and 14 lower sectors (10 degrees each) as well as nasally and temporally (40 degrees each) as provided from the GDx (software version 4000). The healthy control subjects served to determine age-corrected thickness deviation in all sectors. Analyses were calculated in eight nerve fiber bundle related areas. Due to non-linear relationships between perimetric defects and corresponding thickness deviation non-parametric tests were used. Localized visual field defects in the present perimetric patients were highest in upper and lower visual field areas abutting the nasal meridian. Thickness loss of nerve fiber layer however was highest in more circumferential upper and lower nerve fiber bundles. Correlations between local mean defects and deviation of the retinal nerve fiber layer thickness from normals showed a clear association for corresponding areas. The correlation coefficients were significant (P < 0.01) for all arcuate superior and inferior visual field zones except horizontally and not for the area of the lower nasal step. The present correspondence map indicates that focal perimetric defects can be identified best polarimetrically if they occur in the arcuate bundles of the visual field. A lack of correspondence was observed in the area of the papillo-macular bundle.


  • Testing for glaucoma with frequency-doubling perimetry in normals, ocular hypertensives, and glaucoma patients

    by Folkert K. Horn, Nina Wakili, Anselm M. Jünemann, Matthias Korth

    Background. The aim of this study was to evaluate the diagnostic usefulness of the FDT perimeter protocol (C-20-5) in combination with a database system for analysis of single test locations. Methods. One hundred seventy-three ocular hypertensive eyes, 116 "preperimetric" open-angle glaucoma eyes (glaucomatous optic disc atrophy, elevated intraocular pressure, no visual field defects in standard white-on-white perimetry), 199 "perimetric" open-angle glaucoma eyes (glaucomatous optic disc atrophy and visual field defects), and 151 control eyes underwent FDT screening and conventional white-on-white perimetry. Four repeated measurements were carried out in 15 glaucoma patients at 2-h intervals to judge reproducibility of all test locations. The present screening strategy begins testing at the normal 5% probability level. If a stimulus is not detected, further targets are presented. FDT-Viewfinder and statistics software were used for case-wise recalculation of all missed localized probability levels and correlation with corresponding test locations using conventional perimetry. Results. Analysis of repeated measurements in patients reveals that variation of single test points can be considerable. However, the numbers of missed test-stimuli calculated globally or in quadrants are significantly correlated with corresponding Octopus visual field defects (Spearman rank correlation PConclusion. Point-wise analysis of FDT screening results can be helpful for classification of patient groups and consideration of the individual learning curve in repeated measurements. The C-20-5 protocol of the FDT perimeter is able to detect a considerable proportion of glaucomatous patients.