Terrence Jach
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Terrence Jach has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Burkhard Beckhoff
Physikalisch-Technische Bundesanstalt 2 , Abbestraße 2-12, 10587 Berlin
3 shared publications- John Vinson
Material Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, USA
2 shared publications - Joseph A. Dura
NIST Center for Neutron Research, National Institute of Standards and Technology, Gaithersburg, USA
2 shared publications - Rainer Unterumsberger
Physikalisch-Technische Bundesanstalt 2 , Abbestraße 2-12, 10587 Berlin
2 shared publications - Adrian Jonas
Physikalisch-Technische Bundesanstalt (PTB) 1 , Abbestr. 2–12, 10587 Berlin
1 shared publication Albert Macrander
Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439
1 shared publication
Latest Publications
- 8 September 2026
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 165 (10)
X-ray absorption and resonant x-ray emission at the carbon edge of Li2CO3
While highly successful, density functional theory is known to have limitations owing to its neglect of many-body electron–electron interactions. This neglect leads to errors in the single-particle energies, leading to underestimated bandgaps and bandwidths as well as errors in band alignment at interfaces. Many-body perturbation theory, in the form of the GW self-energy correction, has been widely used to improve upon these shortcomings. Although less well studied, the same GW method is also able to predict the finite quasiparticle lifetime that is seen to cause anomalous broadening in the lowest-lying lines of valence emission spectra. Using near-edge x-ray absorption and emission, we probe the electronic structure of Li2CO3. Our measurements are compared to first-principles calculations, including GW self-energy corrections to the single-particle energies and excitonic effects from the Bethe–Salpeter equation.
- 8 September 2026
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 165 (10)
X-ray absorption and resonant x-ray emission at the carbon edge of Li2CO3
While highly successful, density functional theory is known to have limitations owing to its neglect of many-body electron–electron interactions. This neglect leads to errors in the single-particle energies, leading to underestimated bandgaps and bandwidths as well as errors in band alignment at interfaces. Many-body perturbation theory, in the form of the GW self-energy correction, has been widely used to improve upon these shortcomings. Although less well studied, the same GW method is also able to predict the finite quasiparticle lifetime that is seen to cause anomalous broadening in the lowest-lying lines of valence emission spectra. Using near-edge x-ray absorption and emission, we probe the electronic structure of Li2CO3. Our measurements are compared to first-principles calculations, including GW self-energy corrections to the single-particle energies and excitonic effects from the Bethe–Salpeter equation.
- Open Access
- 1 September 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (9)
Calibrated dual soft x-ray spectrometer end-station for polarization-dependent resonant inelastic x-ray scattering
In this work, we present an end-station with two perpendicular high-efficiency soft x-ray spectrometers at the plane grating monochromator beamline in the Physikalisch-Technische Bundesanstalt laboratory at the electron storage ring BESSY II. It is designed for polarization-dependent x-ray emission spectroscopy and resonant inelastic x-ray scattering spectroscopy and covers the photon energy range from 80 to 1100 eV. Depending on the energy range to be monitored, either one of two spherical mirrors and either one of three variable line spacing gratings in each spectrometer is selected to provide optimal performance in terms of resolving power and detection yield. A calibration of the optical components and detection devices enables quantitative measurements and the possibility of the determination of x-ray fluorescence fundamental parameters in the soft x-ray range.
- 1 September 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (9)
Open AccessCalibrated dual soft x-ray spectrometer end-station for polarization-dependent resonant inelastic x-ray scattering
In this work, we present an end-station with two perpendicular high-efficiency soft x-ray spectrometers at the plane grating monochromator beamline in the Physikalisch-Technische Bundesanstalt laboratory at the electron storage ring BESSY II. It is designed for polarization-dependent x-ray emission spectroscopy and resonant inelastic x-ray scattering spectroscopy and covers the photon energy range from 80 to 1100 eV. Depending on the energy range to be monitored, either one of two spherical mirrors and either one of three variable line spacing gratings in each spectrometer is selected to provide optimal performance in terms of resolving power and detection yield. A calibration of the optical components and detection devices enables quantitative measurements and the possibility of the determination of x-ray fluorescence fundamental parameters in the soft x-ray range.
- 2 February 2024
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 218
The present and future of microcalorimeter X-ray detectors for fundamental X-ray parameters
- 2 February 2024
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 218
The present and future of microcalorimeter X-ray detectors for fundamental X-ray parameters
- Open Access
- 23 June 2022
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 55 (4) , 787-812
The effect of transverse wavefront width on specular neutron reflection
In the analysis of neutron scattering measurements of condensed matter structure, it normally suffices to treat the incident and scattered neutron beams as if composed of incoherent distributions of plane waves with wavevectors of different magnitudes and directions that are taken to define an instrumental resolution. However, despite the wide-ranging applicability of this conventional treatment, there are cases, such as specular neutron reflectometry, in which the structural length scales of the scattering object require that the wavefunction of an individual neutron in the beam be described by a spatially localized packet – in particular with respect to the transverse extent of its wavefronts (i.e. normal to the packet's mean direction of propagation). It is shown in the present work that neutron diffraction patterns observed for periodic transmission phase gratings, as well as specular reflection measurements from patterned thin films with repeat units of the order of micrometres, can be accurately described by associating an individual neutron with a wave packet and treating a beam as a collection of independent packets. In these cases, accurate analysis requires that the transverse spatial extent of a neutron packet wavefront be accounted for in addition to the angular divergence of the beam that is characterized by a distribution of packet mean wavevector directions. It is shown how a measure of the effective transverse spatial extent of the neutron packet – over which its wavefronts are of sufficient uniformity to produce coherent scattering – can be determined by employing reference diffraction gratings and patterned thin films of known structure and composition.
- 23 June 2022
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 55 (4) , 787-812
Open AccessThe effect of transverse wavefront width on specular neutron reflection
In the analysis of neutron scattering measurements of condensed matter structure, it normally suffices to treat the incident and scattered neutron beams as if composed of incoherent distributions of plane waves with wavevectors of different magnitudes and directions that are taken to define an instrumental resolution. However, despite the wide-ranging applicability of this conventional treatment, there are cases, such as specular neutron reflectometry, in which the structural length scales of the scattering object require that the wavefunction of an individual neutron in the beam be described by a spatially localized packet – in particular with respect to the transverse extent of its wavefronts (i.e. normal to the packet's mean direction of propagation). It is shown in the present work that neutron diffraction patterns observed for periodic transmission phase gratings, as well as specular reflection measurements from patterned thin films with repeat units of the order of micrometres, can be accurately described by associating an individual neutron with a wave packet and treating a beam as a collection of independent packets. In these cases, accurate analysis requires that the transverse spatial extent of a neutron packet wavefront be accounted for in addition to the angular divergence of the beam that is characterized by a distribution of packet mean wavevector directions. It is shown how a measure of the effective transverse spatial extent of the neutron packet – over which its wavefronts are of sufficient uniformity to produce coherent scattering – can be determined by employing reference diffraction gratings and patterned thin films of known structure and composition.
- 1 June 2022
- Published by American Physical Society (APS) in Physical Review C
- Vol. 105 (6) , L061601
Method for the definitive detection of orbital angular momentum states in neutrons by spin-polarizedA standard method to detect thermal neutrons is the nuclear interaction . The spin dependence of this interaction is also the basis of a neutron spin-polarization filter using nuclear polarized . We consider the corresponding interaction for neutrons placed in an intrinsic orbital angular momentum (OAM) state. We derive the relative polarization-dependent absorption cross sections for neutrons in an OAM state. The absorption of those neutrons results in compound states , , and . Varying the three available polarizations tests that an OAM neutron has been absorbed and probes which decay states are physically possible. We describe the energetically likely excited states of after absorption, taking account of the odd parity of the compound state. This provides a definitive method for detecting neutron OAM states and suggests that intrinsic OAM states offer the possibility to observe new physics, including anomalous cross sections and new channels of radioactive decay.- 1 June 2022
- Published by American Physical Society (APS) in Physical Review C
- Vol. 105 (6) , L061601
Method for the definitive detection of orbital angular momentum states in neutrons by spin-polarizedA standard method to detect thermal neutrons is the nuclear interaction . The spin dependence of this interaction is also the basis of a neutron spin-polarization filter using nuclear polarized . We consider the corresponding interaction for neutrons placed in an intrinsic orbital angular momentum (OAM) state. We derive the relative polarization-dependent absorption cross sections for neutrons in an OAM state. The absorption of those neutrons results in compound states , , and . Varying the three available polarizations tests that an OAM neutron has been absorbed and probes which decay states are physically possible. We describe the energetically likely excited states of after absorption, taking account of the odd parity of the compound state. This provides a definitive method for detecting neutron OAM states and suggests that intrinsic OAM states offer the possibility to observe new physics, including anomalous cross sections and new channels of radioactive decay.- 27 September 2012
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry A
- Vol. 116 (40) , 9897-9899
Surface Effects on the Crystallization of Cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX) and the Consequences for its N K X-ray Emission Spectrum
Recent studies of the crystallization of cyclotrimethylene-trinitramine (RDX) have shown that the presence of the α- and β-phases of the compound is sensitive to the substrate when using drop cast crystallization methods. The specific phase has potential consequences for measurements of the nitrogen K X-ray emission spectrum (XES) that were recently reported for this compound using samples crystallized on In metal substrates. We have determined that the crystallization of RDX on a clean In metal substrate starts out completely as the β-phase but progressively incorporates the α-phase as the film thickens. In addition, we have carried out additional molecular orbital calculations of the N 1s X-ray fluorescence from the valence band, comparing the results expected from the α-and β- phases. The differences due to the presence of the β-phase instead of, or in addition to, the α-phase appear to be minimal.
- 27 September 2012
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry A
- Vol. 116 (40) , 9897-9899
Surface Effects on the Crystallization of Cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX) and the Consequences for its N K X-ray Emission Spectrum
Recent studies of the crystallization of cyclotrimethylene-trinitramine (RDX) have shown that the presence of the α- and β-phases of the compound is sensitive to the substrate when using drop cast crystallization methods. The specific phase has potential consequences for measurements of the nitrogen K X-ray emission spectrum (XES) that were recently reported for this compound using samples crystallized on In metal substrates. We have determined that the crystallization of RDX on a clean In metal substrate starts out completely as the β-phase but progressively incorporates the α-phase as the film thickens. In addition, we have carried out additional molecular orbital calculations of the N 1s X-ray fluorescence from the valence band, comparing the results expected from the α-and β- phases. The differences due to the presence of the β-phase instead of, or in addition to, the α-phase appear to be minimal.
- 9 September 2010
- Published by Wiley in Surface and Interface Analysis
- Vol. 42 (10-11) , 1646-1649
High‐resolution X‐ray spectrometry of solids using the microcalorimeter X‐ray detector
We analyze here the spectrum of the Al Kα and Mg Kα X‐ray lines obtained by electron excitation of a multielement glass. The spectrum was obtained in an electron beam probe using a microcalorimeter X‐ray detector. With 7 eV resolution, we are able to observe and compare the intensity ratios of the Kα 3, 4 satellites to the Kα 1, 2 main lines. These satellites are sensitive to the chemistry of the solid. We compare our observed values to the intensity ratios obtained by Klauber and by Krause & Ferreira. The agreement of the relative satellite intensities in our measurement is more consistent with ratios for metals than for oxides. The ability to observe satellites of lines in multielement samples using the microcalorimeter detector opens up new possibilities for the interpretation of atomic core‐valence processes in solids. Published in 2010 by John Wiley & Sons, Ltd.
- 9 September 2010
- Published by Wiley in Surface and Interface Analysis
- Vol. 42 (10-11) , 1646-1649
High‐resolution X‐ray spectrometry of solids using the microcalorimeter X‐ray detector
We analyze here the spectrum of the Al Kα and Mg Kα X‐ray lines obtained by electron excitation of a multielement glass. The spectrum was obtained in an electron beam probe using a microcalorimeter X‐ray detector. With 7 eV resolution, we are able to observe and compare the intensity ratios of the Kα 3, 4 satellites to the Kα 1, 2 main lines. These satellites are sensitive to the chemistry of the solid. We compare our observed values to the intensity ratios obtained by Klauber and by Krause & Ferreira. The agreement of the relative satellite intensities in our measurement is more consistent with ratios for metals than for oxides. The ability to observe satellites of lines in multielement samples using the microcalorimeter detector opens up new possibilities for the interpretation of atomic core‐valence processes in solids. Published in 2010 by John Wiley & Sons, Ltd.
- 1 March 2009
- Published by Springer Nature in The European Physical Journal Special Topics
- Vol. 169 (1) , 237-242
The microcalorimeter X-ray detector: A true paradigm shift in X-ray spectroscopy
- 1 March 2009
- Published by Springer Nature in The European Physical Journal Special Topics
- Vol. 169 (1) , 237-242
The microcalorimeter X-ray detector: A true paradigm shift in X-ray spectroscopy
- 1 May 2006
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 111 (3) , 219-25
Variable Magnification With Kirkpatrick-Baez Optics for Synchrotron X-Ray Microscopy
We describe the distinction between the operation of a short focal length x-ray microscope forming a real image with a laboratory source (convergent illumination) and with a highly collimated intense beam from a synchrotron light source (Köhler illumination). We demonstrate the distinction with a Kirkpatrick-Baez microscope consisting of short focal length multilayer mirrors operating at an energy of 8 keV. In addition to realizing improvements in the resolution of the optics, the synchrotron radiation microscope is not limited to the usual single magnification at a fixed image plane. Higher magnification images are produced by projection in the limit of geometrical optics with a collimated beam. However, in distinction to the common method of placing the sample behind the optical source of a diverging beam, we describe the situation in which the sample is located in the collimated beam before the optical element. The ultimate limits of this magnification result from diffraction by the specimen and are determined by the sample position relative to the focal point of the optic. We present criteria by which the diffraction is minimized.
- 1 May 2006
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 111 (3) , 219-25
Variable Magnification With Kirkpatrick-Baez Optics for Synchrotron X-Ray Microscopy
We describe the distinction between the operation of a short focal length x-ray microscope forming a real image with a laboratory source (convergent illumination) and with a highly collimated intense beam from a synchrotron light source (Köhler illumination). We demonstrate the distinction with a Kirkpatrick-Baez microscope consisting of short focal length multilayer mirrors operating at an energy of 8 keV. In addition to realizing improvements in the resolution of the optics, the synchrotron radiation microscope is not limited to the usual single magnification at a fixed image plane. Higher magnification images are produced by projection in the limit of geometrical optics with a collimated beam. However, in distinction to the common method of placing the sample behind the optical source of a diverging beam, we describe the situation in which the sample is located in the collimated beam before the optical element. The ultimate limits of this magnification result from diffraction by the specimen and are determined by the sample position relative to the focal point of the optic. We present criteria by which the diffraction is minimized.