Kathleen C. Kobashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kathleen C. Kobashi has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Tanya M. Nazemi
Continence Center, Virginia Mason Medical Center, Seattle, Washington 98111, USA
3 shared publications- David E. Rapp
Department of Urology, University of Virginia, Charlottesville, Virginia
2 shared publications Fred E. Govier
Continence Center, Virginia Mason Medical Center, Seattle, Washington
2 shared publicationsBhavin N. Patel
Virginia Mason Medical Center
1 shared publicationFred Govier
1 shared publication- Gjanjé L. Smith
Continence Center at Virginia Mason, 1100 Ninth Avenue, C7-Uro, Seattle, WA 98101, USA
1 shared publication
Latest Publications
- 31 January 2014
- Published by Springer Nature
- p. 227-237
Pelvic Organ Prolapse: Posterior Repairs
- 16 November 2010
- Published by Springer Nature in Current Bladder Dysfunction Reports
- Vol. 6 (1) , 31-36
Augmentation Cystoplasty
- 16 November 2010
- Published by Springer Nature in Current Bladder Dysfunction Reports
- Vol. 6 (1) , 31-36
Augmentation Cystoplasty
- 30 April 2009
- Published by Wolters Kluwer Health in Journal of Urology
- Vol. 181 (4) , 599
IDENTIFICATION OF MEASURES OF BLADDER SENSATION IN PATIENTS WITH OVERACTIVE BLADDER
- 30 April 2009
- Published by Wolters Kluwer Health in Journal of Urology
- Vol. 181 (4) , 599
IDENTIFICATION OF MEASURES OF BLADDER SENSATION IN PATIENTS WITH OVERACTIVE BLADDER
- 8 March 2009
- Published by Springer Nature in Current Bladder Dysfunction Reports
- Vol. 4 (1) , 5-10
Review of the 2008 Annual Meeting of the Society of Urodynamics and Female Urology (SUFU) at the American Urological Association
- 8 March 2009
- Published by Springer Nature in Current Bladder Dysfunction Reports
- Vol. 4 (1) , 5-10
Review of the 2008 Annual Meeting of the Society of Urodynamics and Female Urology (SUFU) at the American Urological Association
- Open Access
- 1 January 2009
- Published by Hindawi Limited in The Scientific World Journal
- Vol. 9, 32-36
Management of Erosion of Graft Materials in Pelvic Floor Reconstruction
We present an overview of the current literature and management techniques for vaginal extrusion or urinary tract erosion of graft materials used in pelvic floor reconstruction. A MEDLINE search was performed to identify literature pertaining to the incidence and management of vaginal or urinary tract exposure of graft materials commonly used in anti-incontinence and pelvic floor reconstructive procedures. Dependent on the type of mesh material used, a vaginal extrusion rate of up to 77% has been reported. The currently accepted, loosely woven, monofilament type I polypropylene meshes appear to have acceptable lower exposure rates in the range of 1–3% for slings, but with the larger area of mesh used in prolapse repairs, the rate increases to up to 10%. With the current widespread use of graft materials to reinforce pelvic floor reconstructive techniques, it is imperative for surgeons to be familiar with potential complications related to the materials and proper management of these complications. Although it is beginning to appear that the benefit of using some synthetic materials may outweigh the risks, proper management and understanding of the risks is important in order to counsel our patients appropriately and responsibly prior to their surgeries.
- 1 January 2009
- Published by Hindawi Limited in The Scientific World Journal
- Vol. 9, 32-36
Open AccessManagement of Erosion of Graft Materials in Pelvic Floor Reconstruction
We present an overview of the current literature and management techniques for vaginal extrusion or urinary tract erosion of graft materials used in pelvic floor reconstruction. A MEDLINE search was performed to identify literature pertaining to the incidence and management of vaginal or urinary tract exposure of graft materials commonly used in anti-incontinence and pelvic floor reconstructive procedures. Dependent on the type of mesh material used, a vaginal extrusion rate of up to 77% has been reported. The currently accepted, loosely woven, monofilament type I polypropylene meshes appear to have acceptable lower exposure rates in the range of 1–3% for slings, but with the larger area of mesh used in prolapse repairs, the rate increases to up to 10%. With the current widespread use of graft materials to reinforce pelvic floor reconstructive techniques, it is imperative for surgeons to be familiar with potential complications related to the materials and proper management of these complications. Although it is beginning to appear that the benefit of using some synthetic materials may outweigh the risks, proper management and understanding of the risks is important in order to counsel our patients appropriately and responsibly prior to their surgeries.
- 25 March 2008
- Published by Springer Nature in Nature Reviews Endocrinology
- Vol. 5 (5) , 242-3
What is the relationship between the transobturator tape procedure and urethral mobility in women with SUI?
- 25 March 2008
- Published by Springer Nature in Nature Reviews Endocrinology
- Vol. 5 (5) , 242-3
What is the relationship between the transobturator tape procedure and urethral mobility in women with SUI?
- 1 September 2007
- Published by Springer Nature in Current Bladder Dysfunction Reports
- Vol. 2 (3) , 155-160
Lower urinary tract and bowel dysfunction after incontinence and prolapse interventions
- 1 September 2007
- Published by Springer Nature in Current Bladder Dysfunction Reports
- Vol. 2 (3) , 155-160
Lower urinary tract and bowel dysfunction after incontinence and prolapse interventions
- 22 June 2007
- Published by Springer Nature in Current Bladder Dysfunction Reports
- Vol. 2 (2) , 79-85
Synthetic sling options for stress urinary incontinence
- 22 June 2007
- Published by Springer Nature in Current Bladder Dysfunction Reports
- Vol. 2 (2) , 79-85
Synthetic sling options for stress urinary incontinence
- Open Access
- 1 January 2007
- Published by Medknow in Indian Journal of Urology
- Vol. 23 (2) , 153-60
Complications of grafts used in female pelvic floor reconstruction: Mesh erosion and extrusion
Introduction: Various grafts have been used in the treatment of urinary incontinence and pelvic prolapse. Autologous materials such as muscle and fascia were first utilized to provide additional anatomic support to the periurethral and pelvic tissues; however, attempts to minimize the invasiveness of the procedures have led to the use of synthetic materials. Complications such as infection and erosion or extrusion associated with these materials may be troublesome to manage. We review the literature and describe a brief overview of grafts used in pelvic floor reconstruction and focus on the management complications specifically related to synthetic materials. Materials and Methods: We performed a comprehensive review of the literature on grafts used in pelvic floor surgery using MEDLINE and resources cited in those peer-reviewed manuscripts. The results are presented. Results: Biologic materials provide adequate cure rates but have associated downfalls including potential complications from harvesting, variable tissue quality and cost. The use of synthetic materials as an alternative graft in pelvic floor repairs has become a popular option. Of all synthetic materials, the type I macroporous polypropylene meshes have demonstrated superiority in terms of efficacy and fewer complication rates due to their structure and composition. Erosion and extrusion of mesh are common and troublesome complications that may be managed conservatively with observation with or without local hormone therapy, with transvaginal debridement or with surgical exploration and total mesh excision, dependent upon the location of the mesh and the mesh type utilized. Conclusions: The ideal graft would provide structural integrity and durability with minimal adverse reaction by the host tissue. Biologic materials in general tend to have fewer associated complications, however, the risks of harvesting, variable integrity of allografts, availability and high cost has led to the development and use of synthetic grafts. Synthetic grafts have a tendency to cause higher rates of erosion and extrusion; however, these complications can be managed successfully.
- 1 January 2007
- Published by Medknow in Indian Journal of Urology
- Vol. 23 (2) , 153-60
Open AccessComplications of grafts used in female pelvic floor reconstruction: Mesh erosion and extrusion
Introduction: Various grafts have been used in the treatment of urinary incontinence and pelvic prolapse. Autologous materials such as muscle and fascia were first utilized to provide additional anatomic support to the periurethral and pelvic tissues; however, attempts to minimize the invasiveness of the procedures have led to the use of synthetic materials. Complications such as infection and erosion or extrusion associated with these materials may be troublesome to manage. We review the literature and describe a brief overview of grafts used in pelvic floor reconstruction and focus on the management complications specifically related to synthetic materials. Materials and Methods: We performed a comprehensive review of the literature on grafts used in pelvic floor surgery using MEDLINE and resources cited in those peer-reviewed manuscripts. The results are presented. Results: Biologic materials provide adequate cure rates but have associated downfalls including potential complications from harvesting, variable tissue quality and cost. The use of synthetic materials as an alternative graft in pelvic floor repairs has become a popular option. Of all synthetic materials, the type I macroporous polypropylene meshes have demonstrated superiority in terms of efficacy and fewer complication rates due to their structure and composition. Erosion and extrusion of mesh are common and troublesome complications that may be managed conservatively with observation with or without local hormone therapy, with transvaginal debridement or with surgical exploration and total mesh excision, dependent upon the location of the mesh and the mesh type utilized. Conclusions: The ideal graft would provide structural integrity and durability with minimal adverse reaction by the host tissue. Biologic materials in general tend to have fewer associated complications, however, the risks of harvesting, variable integrity of allografts, availability and high cost has led to the development and use of synthetic grafts. Synthetic grafts have a tendency to cause higher rates of erosion and extrusion; however, these complications can be managed successfully.