Yoshio Utaka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yoshio Utaka has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Shixue Wang
School of Mechanical Engineering Tianjin University Tianjin China
7 shared publicationsYutaka Tasaki
Nissan Research Center, Nissan Motor Co., Ltd., Natsushima-cho 1-1, Yokosuka-shi, Kanagawa-ken 237-8523, Japan
6 shared publicationsZhihao Chen
School of Mechanical Engineering, Tianjin University, Tianjin, China
3 shared publicationsIkunori Hirose
Olympus Co, Kuboyama-cho 2-3, Hachioji, Tokyo 192-8512, Japan
2 shared publications- Ryo Koresawa
Yokohama National University
2 shared publications Chen Liang
National New Energy Vehicle Technology Innovation Center, Beijing, CHINA
1 shared publication
Latest Publications
- 1 January 2022
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 182
Flow boiling critical heat flux enhancement via different-mode-interacting boiling in narrow gaps
- 1 January 2022
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 182
Flow boiling critical heat flux enhancement via different-mode-interacting boiling in narrow gaps
- 19 April 2021
- Published by Springer Nature in Journal of Thermal Science
- Vol. 30 (6) , 1951-1959
An Improved Treatment on the Apparent Contact Angle of a Single-Bubble in Consideration of Microlayer for Simulations of Nucleate Pool Boiling
- 19 April 2021
- Published by Springer Nature in Journal of Thermal Science
- Vol. 30 (6) , 1951-1959
An Improved Treatment on the Apparent Contact Angle of a Single-Bubble in Consideration of Microlayer for Simulations of Nucleate Pool Boiling
- 2 April 2021
- Published by Wiley in International Journal of Energy Research
- Vol. 45 (9) , 13760-13770
Improvement of cold start performance of polymer electrolyte fuel cell using microporous and gas diffusion layers with patterned wettability
- 2 April 2021
- Published by Wiley in International Journal of Energy Research
- Vol. 45 (9) , 13760-13770
Improvement of cold start performance of polymer electrolyte fuel cell using microporous and gas diffusion layers with patterned wettability
- Open Access
Effect of Dual Porous Layers with Patterned Wettability on Low-Temperature Start Performance of Polymer Electrolyte Membrane Fuel Cell
The low-temperature start problem of polymer electrolyte membrane fuel cells (PEMFCs) is a factor limiting their large-scale application. To improve the low-temperature start performance of a PEMFC, a novel microporous layer (MPL) and a gas diffusion layer (GDL) with planar wettability distribution, in which the hydrophilic and hydrophobic lines were arranged alternately in the in-plane direction, were investigated in this study. The influence of the dual planar-distributed wettability of the MPL and GDL on the normal temperature and low-temperature start performance of the PEMFC was investigated. Before performing the major experiment, the effect of the assembly pressure of the membrane electrode assembly (MEA), which has a significant effect on the PEMFC performance, was examined and determined to use in the experiment. The experimental results show that the dual hybrid MPL and GDL can further prolong the operation time of the PEMFC at different below-freezing temperatures owing to efficient water management and thus significantly improve the low-temperature start performance of the PEMFC.
Open AccessEffect of Dual Porous Layers with Patterned Wettability on Low-Temperature Start Performance of Polymer Electrolyte Membrane Fuel Cell
The low-temperature start problem of polymer electrolyte membrane fuel cells (PEMFCs) is a factor limiting their large-scale application. To improve the low-temperature start performance of a PEMFC, a novel microporous layer (MPL) and a gas diffusion layer (GDL) with planar wettability distribution, in which the hydrophilic and hydrophobic lines were arranged alternately in the in-plane direction, were investigated in this study. The influence of the dual planar-distributed wettability of the MPL and GDL on the normal temperature and low-temperature start performance of the PEMFC was investigated. Before performing the major experiment, the effect of the assembly pressure of the membrane electrode assembly (MEA), which has a significant effect on the PEMFC performance, was examined and determined to use in the experiment. The experimental results show that the dual hybrid MPL and GDL can further prolong the operation time of the PEMFC at different below-freezing temperatures owing to efficient water management and thus significantly improve the low-temperature start performance of the PEMFC.
- 1 April 2019
- Published by Elsevier in International Journal of Refrigeration
- Vol. 100, 335-342
Adhesion characteristics of ice in urea aqueous solution for efficient slurry formation in cold storage
- 1 April 2019
- Published by Elsevier in International Journal of Refrigeration
- Vol. 100, 335-342
Adhesion characteristics of ice in urea aqueous solution for efficient slurry formation in cold storage
- 1 January 2017
- Published by Begell House Inc. Publishers in Journal of Enhanced Heat Transfer
- Vol. 24 (1-6) , 279-290
MEASUREMENT OF CONDENSATE FILM THICKNESS FOR SOLUTAL MARANGONI CONDENSATION
During solutal Marangoni dropwise condensation of a water–ethanol vapor mixture, condensation was observed by a high-speed camera while condensate film thickness was measured by the laser light extinction method. Good correspondence was observed between the film thickness data and the observed condensate behaviors. Minimum condensate film thickness occurred immediately after a departing drop swept by and decreased with increasing initial drop distance in the steep increase region of the condensation characteristic curve. In the region of higher cooling intensity, both initial drop distance and minimum condensate thickness increased with cooling intensity. The smallest thickness of the condensate film was less than 1 μm. A close relationship was confirmed to exist among condensate film thickness, initial drop distance, and heat transfer characteristics.
- 1 January 2017
- Published by Begell House Inc. Publishers in Journal of Enhanced Heat Transfer
- Vol. 24 (1-6) , 279-290
MEASUREMENT OF CONDENSATE FILM THICKNESS FOR SOLUTAL MARANGONI CONDENSATION
During solutal Marangoni dropwise condensation of a water–ethanol vapor mixture, condensation was observed by a high-speed camera while condensate film thickness was measured by the laser light extinction method. Good correspondence was observed between the film thickness data and the observed condensate behaviors. Minimum condensate film thickness occurred immediately after a departing drop swept by and decreased with increasing initial drop distance in the steep increase region of the condensation characteristic curve. In the region of higher cooling intensity, both initial drop distance and minimum condensate thickness increased with cooling intensity. The smallest thickness of the condensate film was less than 1 μm. A close relationship was confirmed to exist among condensate film thickness, initial drop distance, and heat transfer characteristics.
- 17 December 2014
- Published by Taylor & Francis in Heat Transfer Engineering
- Vol. 36 (14-15) , 1282-1291
Improvement in Performance of Secondary Heat Exchanger for Gas Water Heater by Using Narrow Tubes
A new type of heat exchanger, in which flue gas flows inside narrow tubes and water is on the shell side, was proposed to develop the performance and compactness of the shell-and-tube type heat exchanger for latent heat recovery from flue gas. The effects of tube diameter (1.0–5.0 mm) and heat exchange length (7–100 mm) on the heat transfer characteristics of a single tube were systematically investigated by measuring the gas outlet temperature, the pressure loss of the gas, and the condensation rate for moist air. It was shown that the usage of narrower tubes was remarkably effective in achieving the high performance. A rapid temperature drop occurred near the inlet and a high heat transfer rate were realized for narrower tubes with inner diameters of 1.0 and 2.0 mm than with thicker tubes due to the smaller heat capacity flow rate and higher heat transfer coefficient. In addition, the increase in the heat transfer area per volume in the narrow tube type heat exchanger contributed to the compactness. The heat exchanging volume was successfully downsized by one-twentieth by changing the 5.0-mm inner diameter tubes to smaller tubes with 1.0-mm inner diameters.
- 17 December 2014
- Published by Taylor & Francis in Heat Transfer Engineering
- Vol. 36 (14-15) , 1282-1291
Improvement in Performance of Secondary Heat Exchanger for Gas Water Heater by Using Narrow Tubes
A new type of heat exchanger, in which flue gas flows inside narrow tubes and water is on the shell side, was proposed to develop the performance and compactness of the shell-and-tube type heat exchanger for latent heat recovery from flue gas. The effects of tube diameter (1.0–5.0 mm) and heat exchange length (7–100 mm) on the heat transfer characteristics of a single tube were systematically investigated by measuring the gas outlet temperature, the pressure loss of the gas, and the condensation rate for moist air. It was shown that the usage of narrower tubes was remarkably effective in achieving the high performance. A rapid temperature drop occurred near the inlet and a high heat transfer rate were realized for narrower tubes with inner diameters of 1.0 and 2.0 mm than with thicker tubes due to the smaller heat capacity flow rate and higher heat transfer coefficient. In addition, the increase in the heat transfer area per volume in the narrow tube type heat exchanger contributed to the compactness. The heat exchanging volume was successfully downsized by one-twentieth by changing the 5.0-mm inner diameter tubes to smaller tubes with 1.0-mm inner diameters.
- 1 January 2014
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Thermal Engineering Conference
- Vol. 2014, _A124-1_
A124 The effects of liquid properties on the rupture thickness of thin liquid film in bubble coalescence process
This study aims to elucidate the break characteristics of liquid film formed between approaching bubbles in the process of bubble coalescence. The coalescence of horizontally contacting twin bubbles was experimentally studied in isothermal system. The bubbles were generated at the outlets of two pipes that face each other horizontally. Liquid film thickness formed between approaching bubbles were measured by the modified laser extinction method. The variation and the distribution of liquid film thickness between bubbles were investigated. The air flow rate, sample liquids and the measuring position of liquid film thickness were adopted as the experimental parameters.
- 1 January 2014
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Thermal Engineering Conference
- Vol. 2014, _A124-1_
A124 The effects of liquid properties on the rupture thickness of thin liquid film in bubble coalescence process
This study aims to elucidate the break characteristics of liquid film formed between approaching bubbles in the process of bubble coalescence. The coalescence of horizontally contacting twin bubbles was experimentally studied in isothermal system. The bubbles were generated at the outlets of two pipes that face each other horizontally. Liquid film thickness formed between approaching bubbles were measured by the modified laser extinction method. The variation and the distribution of liquid film thickness between bubbles were investigated. The air flow rate, sample liquids and the measuring position of liquid film thickness were adopted as the experimental parameters.