Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Chin-Chuan Han has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Biosignal-Driven Wearable System Integrating Surface Electromyography and Kinematics for Interpretable Upper-Limb Assessment

    by Yu-Chi Wu, Kuo-Yin Lee, Hao-Pu Lin, Chin-Chuan Han, Yuan-Yang Cheng

    Continuous monitoring of neuromuscular and kinematic behaviors is crucial for effective upper-limb rehabilitation. This study presents a biosignal-driven, wrist-worn multimodal sensing system that combines discrete 12-class functional hand-gesture recognition with an exploratory multimodal physical interpretation of motion deviations. The platform integrates a surface electromyography (sEMG) envelope sensor for macroscopic motor unit recruitment, dual force-sensitive resistors (FSR) for end-effector contact force modulation, and an inertial measurement unit (IMU) for spatial–temporal biokinematics. Data collected from 20 healthy adults (12,000 one-second trials, each containing 100 synchronized time points at 100 Hz) demonstrated that a one-dimensional convolutional neural network (1D-CNN) achieves 81.23% ± 16.74% accuracy under subject-independent leave-one-subject-out (LOSO) cross-validation, capturing natural inter-individual neuromuscular variations. For baseline within-dataset comparison, a class-stratified random split yielded a macro F1-score of 96.59%. To bridge the gap between classification and clinical interpretation, we implemented a multimodal Dynamic Time Warping (DTW) pipeline. This approach successfully identified maximal-difference segments (Hotzones) across the aligned biosignals, enabling a qualitative visualization of candidate multimodal physical deviations (sEMG envelope and IMU/FSR kinematic discrepancies) during gesture execution. By establishing gesture-specific reference distributions from healthy subjects, this cost-effective, low-latency IoT biosensor platform demonstrates preliminary technical feasibility. It lays the groundwork for prospective clinical validation in stroke survivors, aiming to capture compensatory mechanisms and support home-based precision rehabilitation.

  • Open Access

    A Mold Damage Monitoring Algorithm for Power Metallurgy Molding Machines Using Bidirectional Long Short-Term Memory on an Internet of Things Platform

    by Hao-Pu Lin, Yuan-Chieh Chen, Chin-Chuan Han, Yu-Chi Wu, Jin-Yuan Lin

    In this paper, an analysis and monitoring algorithm is proposed for mold health evaluation using vibration data. Two inertial measurement units (IMUs) and an embedded system are first used to acquire vibration data from a powder metallurgy molding machine. These data are collected on an Internet of Things (IoT) platform using the Message Queueing Telemetry Transport (MQTT) protocol. For data analysis, the vibration signal on the Z axis is segmented to label the contact section of the upper and middle molds, and the corresponding vibration data of the stamping friction on the X, Y, and Z axes are extracted. Using only historical vibration data from normal stamping, a Bidirectional Long Short-Term Memory (Bi-LSTM) model with an attention mechanism is trained to predict normal stamping vibrations several minutes in advance. By comparing the predicted stamping vibrations with the observed data at the current time, the mean square errors (MSEs) are calculated to evaluate the health status of the mold. Several ablation experiments were conducted to assess the performance of the trained model. The average MSE values for normal samples and abnormal samples were smaller than 0.5 and larger than 1.0, respectively. The experimental results confirm that the trained prediction model and evaluation indicators can effectively notify operators in advance. An early warning system using vibration data for mold damage was successfully implemented, enhancing predictive maintenance.

  • Open Access

    Development of an IMU-Based Post-Stroke Gait Data Acquisition and Analysis System for the Gait Assessment and Intervention Tool

    by Yu-Chi Wu, Yu-Jung Huang, Chin-Chuan Han, Yuan-Yang Cheng, Chao-Shu Chang

    Stroke is the fifth leading cause of death in Taiwan. In the process of stroke treatment, rehabilitation for gait recovery is one of the most critical aspects of treatment. The Gait Assessment and Intervention Tool (G.A.I.T.) is currently used in clinical practice to assess the gait recovery level; however, G.A.I.T. heavily depends on physician training and clinical judgment. With the advancement of technology, today’s small, lightweight inertial measurement unit (IMU) wearable sensors are rapidly revolutionizing gait assessment and may be incorporated into routine clinical practice. In this paper, we developed a gait data acquisition and analysis system based on IMU wearable devices, proposed a simple yet accurate calibration process to reduce the IMU drifting errors, designed a machine learning algorithm to obtain real-time coordinates from IMU data, computed gait parameters, and derived a formula for G.A.I.T. scores with significant correlation with the physician’s observational scores.


  • Open Access

    Development of Wearable Devices for Collecting Digital Rehabilitation/Fitness Data from Lower Limbs

    by Yu-Jung Huang, Chao-Shu Chang, Yu-Chi Wu, Chin-Chuan Han, Yuan-Yang Cheng, Hsian-Min Chen

    Lower extremity exercises are considered a standard and necessary treatment for rehabilitation and a well-rounded fitness routine, which builds strength, flexibility, and balance. The efficacy of rehabilitation programs hinges on meticulous monitoring of both adherence to home exercise routines and the quality of performance. However, in a home environment, patients often tend to inaccurately report the number of exercises performed and overlook the correctness of their rehabilitation motions, lacking quantifiable and systematic standards, thus impeding the recovery process. To address these challenges, there is a crucial need for a lightweight, unbiased, cost-effective, and objective wearable motion capture (Mocap) system designed for monitoring and evaluating home-based rehabilitation/fitness programs. This paper focuses on the development of such a system to gather exercise data into usable metrics. Five radio frequency (RF) inertial measurement unit (IMU) devices (RF-IMUs) were developed and strategically placed on calves, thighs, and abdomens. A two-layer long short-term memory (LSTM) model was used for fitness activity recognition (FAR) with an average accuracy of 97.4%. An intelligent smartphone algorithm was developed to track motion, recognize activity, and calculate key exercise variables in real time for squat, high knees, and lunge exercises. Additionally, a 3D avatar on the smartphone App allows users to observe and track their progress in real time or by replaying their exercise motions. A dynamic time warping (DTW) algorithm was also integrated into the system for scoring the similarity in two motions. The system’s adaptability shows promise for applications in medical rehabilitation and sports.


  • Open Access

    Mold Damage Monitoring for Power Metallurgy Molding Machines Using Deep Learning Methods

    by Hao Pu Lin, Yuan-Chieh Chen, Chin-Chuan Han, Yu-Chi Wu, Chao-Shu Chang, Jin-Yuan Lin

    Mold Damage Monitoring for Power Metallurgy Molding Machines Using Deep Learning Methods


  • Open Access

    Bluetooth-Based Healthcare Information and Medical Resource Management System

    by Chao-Shu Chang, Tin-Hao Wu, Yu-Chi Wu, Chin-Chuan Han

    This paper presents a healthcare information and medical resource management platform utilizing wearable devices, physiological sensors, and an indoor positioning system (IPS). This platform provides medical healthcare information management based on the physiological information collected by wearable devices and Bluetooth data collectors. The Internet of Things (IoT) is constructed for this medical care purpose. The collected data are classified and used to monitor the status of patients in real time with a Secure MQTT mechanism. The measured physiological signals are also used for developing an IPS. When the patient is out of the safety zone, the IPS will send an alert message instantly by pushing the server to remind the caretaker, easing the caretaker’s burden and offering extra protection for the patient. The presented system also provides medical resource management with the help of IPS. The medical equipment and devices can be tracked by IPS to tackle some equipment rental problems, such as lost and found. A platform for the medical staff work coordination information exchange and transmission is also developed to expedite the maintenance of medical equipment, providing the shared medical information to healthcare and management staff in a timely and transparent manner. The presented system in this paper will finally reduce the loading of medical staff during the COVID-19 pandemic period.


  • Open Access

    Development of an Electronic Stethoscope and a Classification Algorithm for Cardiopulmonary Sounds

    by Yu-Chi Wu, Chin-Chuan Han, Chao-Shu Chang, Fu-Lin Chang, Shi-Feng Chen, Tsu-Yi Shieh, Hsian-Min Chen, Jin-Yuan Lin

    With conventional stethoscopes, the auscultation results may vary from one doctor to another due to a decline in his/her hearing ability with age or his/her different professional training, and the problematic cardiopulmonary sound cannot be recorded for analysis. In this paper, to resolve the above-mentioned issues, an electronic stethoscope was developed consisting of a traditional stethoscope with a condenser microphone embedded in the head to collect cardiopulmonary sounds and an AI-based classifier for cardiopulmonary sounds was proposed. Different deployments of the microphone in the stethoscope head with amplification and filter circuits were explored and analyzed using fast Fourier transform (FFT) to evaluate the effects of noise reduction. After testing, the microphone placed in the stethoscope head surrounded by cork is found to have better noise reduction. For classifying normal (healthy) and abnormal (pathological) cardiopulmonary sounds, each sample of cardiopulmonary sound is first segmented into several small frames and then a principal component analysis is performed on each small frame. The difference signal is obtained by subtracting PCA from the original signal. MFCC (Mel-frequency cepstral coefficients) and statistics are used for feature extraction based on the difference signal, and ensemble learning is used as the classifier. The final results are determined by voting based on the classification results of each small frame. After the testing, two distinct classifiers, one for heart sounds and one for lung sounds, are proposed. The best voting for heart sounds falls at 5–45% and the best voting for lung sounds falls at 5–65%. The best accuracy of 86.9%, sensitivity of 81.9%, specificity of 91.8%, and F1 score of 86.1% are obtained for heart sounds using 2 s frame segmentation with a 20% overlap, whereas the best accuracy of 73.3%, sensitivity of 66.7%, specificity of 80%, and F1 score of 71.5% are yielded for lung sounds using 5 s frame segmentation with a 50% overlap.


  • Open Access

    Development of AI Algorithm for Weight Training Using Inertial Measurement Units

    by Yu-Chi Wu, Shi-Xin Lin, Jing-Yuan Lin, Chin-Chuan Han, Chao-Shu Chang, Jun-Xian Jiang

    Thanks to the rapid development of Wearable Fitness Trackers (WFTs) and Smartphone Pedometer Apps (SPAs), people are keeping an eye on their health through fitness and heart rate tracking; therefore, home weight training exercises have received a lot of attention lately. A multi-procedure intelligent algorithm for weight training using two inertial measurement units (IMUs) is proposed in this paper. The first procedure is for motion tracking that estimates the arm orientation and calculates the positions of the wrist and elbow. The second procedure is for posture recognition based on deep learning, which identifies the type of exercise posture. The final procedure is for exercise prescription variables, which first infers the user’s exercise state based on the results of the previous two procedures, triggers the corresponding event, and calculates the key indicators of the weight training exercise (exercise prescription variables), including exercise items, repetitions, sets, training capacity, workout capacity, training period, explosive power, etc.). This study integrates the hardware and software as a complete system. The developed smartphone App is able to receive heart rate data, to analyze the user’s exercise state, and to calculate the exercise prescription variables automatically in real-time. The dashboard in the user interface of the smartphone App can display exercise information through Unity’s Animation System (avatar) and graphics, and records are stored by the SQLite database. The designed system was proven by two types of experimental verification tests. The first type is to control a stepper motor to rotate the designed IMU and to compare the rotation angle obtained from the IMU with the rotation angle of the controlled stepper motor. The average mean absolute error of estimation for 31 repeated experiments is 1.485 degrees. The second type is to use Mediapipe Pose to calculate the position of the wrist and the angles of upper arm and forearm between the Z-axis, and these calculated data are compared with the designed system. The root-mean-square (RMS) error of positions of the wrist is 2.43 cm, and the RMS errors of two angles are 5.654 and 4.385 degrees for upper arm and forearm, respectively. For posture recognition, 12 participants were divided into training group and test group. Eighty percent and 20% of 24,963 samples of 10 participants were used for the training and validation of the LSTM model, respectively. Three-thousand-three-hundred-and-fifty-nine samples of two participants were used to evaluate the performance of the trained LSTM model. The accuracy reached 99%, and F1 score was 0.99. When compared with the other LSTM-based variants, the accuracy of one-layer LSTM presented in this paper is still promising. The exercise prescription variables provided by the presented system are helpful for weight trainers/trainees to closely keep an eye on their fitness progress and for improving their health.


  • Open Access

    Feature Line Embedding Based on Support Vector Machine for Hyperspectral Image Classification

    by Ying-Nong Chen, Tipajin Thaipisutikul, Chin-Chuan Han, Tzu-Jui Liu, Kuo-Chin Fan

    In this paper, a novel feature line embedding (FLE) algorithm based on support vector machine (SVM), referred to as SVMFLE, is proposed for dimension reduction (DR) and for improving the performance of the generative adversarial network (GAN) in hyperspectral image (HSI) classification. The GAN has successfully shown high discriminative capability in many applications. However, owing to the traditional linear-based principal component analysis (PCA) the pre-processing step in the GAN cannot effectively obtain nonlinear information; to overcome this problem, feature line embedding based on support vector machine (SVMFLE) was proposed. The proposed SVMFLE DR scheme is implemented through two stages. In the first scatter matrix calculation stage, FLE within-class scatter matrix, FLE between-scatter matrix, and support vector-based FLE between-class scatter matrix are obtained. Then in the second weight determination stage, the training sample dispersion indices versus the weight of SVM-based FLE between-class matrix are calculated to determine the best weight between-scatter matrices and obtain the final transformation matrix. Since the reduced feature space obtained by the SVMFLE scheme is much more representative and discriminative than that obtained using conventional schemes, the performance of the GAN in HSI classification is higher. The effectiveness of the proposed SVMFLE scheme with GAN or nearest neighbor (NN) classifiers was evaluated by comparing them with state-of-the-art methods and using three benchmark datasets. According to the experimental results, the performance of the proposed SVMFLE scheme with GAN or NN classifiers was higher than that of the state-of-the-art schemes in three performance indices. Accuracies of 96.3%, 89.2%, and 87.0% were obtained for the Salinas, Pavia University, and Indian Pines Site datasets, respectively. Similarly, this scheme with the NN classifier also achieves 89.8%, 86.0%, and 76.2% accuracy rates for these three datasets.


  • Open Access

    An Automatic Chinese Medicine Dispensing Machine Using Shelf-Based Mechanism

    by Jin-Yuan Lin, Jing-Min Lin, Chin-Chuan Han, Yu-Chi Wu, Chao-Shu Chang

    Chinese medicine is a time-honored and deeply valued medical skill in the Chinese community. Although currently the scientific Chinese medicine powder is prevalent, its varieties are numerous and have similar appearance, color, and odor, resulting in difficulties in being distinguished. Moreover, dosages are still weighed and mixed manually, rather than being automated; therefore, the workload for each Chinese medicine pharmacist is heavy, leading to it being easy for the wrong medicine to be administered due to human negligence. An innovative shelf-based automatic powder dispensing machine is therefore presented in this paper in order to promote the quality and efficiency of powder dispensing. This machine consists of linear guide mechanisms, weighing mechanisms, retractable mechanisms, gallipot base discharge mechanisms, and a lifting platform mechanism, and offers several innovative or important features that are beneficial to Chinese medicine. It can automatically and accurately dispense different powders in the correct weights, reducing the possibility of human error. Each gallipot is equipped with one low-cost gallipot base, which can be controlled by the weighing mechanism to discharge powder with the desired weight. Powder cross-contamination among different gallipots can also be avoided. Stepping motors are used in the presented machine for easy control, low cost, and durability. A parabolic type of S mode speed control for stepping motor is implemented, providing faster and more stable moving speed and accuracy than the traditional trapezoidal mode. Hardware and software are integrated and tested. The error of the weighed powder is reduced to +/−0.2 g. The dispensing process is very efficient, the moving speed of the weighing mechanism reaches 23.89 cm/s, and the discharge speed is up to 0.22 g/s. The system is indeed able to improve the accuracy and efficiency of powder dispensing for Chinese medicine.