MSMasato Saito

Masato Saito

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Masato Saito has a total of 107 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Surface Modification of Screen-Printed Carbon Electrode through Oxygen Plasma to Enhance Biosensor Sensitivity

    by Shuto Osaki, Masato Saito, Hidenori Nagai, Eiichi Tamiya

    The screen-printed carbon electrode (SPCE) is a useful technology that has been widely used in the practical application of biosensors oriented to point-of-care testing (POCT) due to its characteristics of cost-effectiveness, disposability, miniaturization, wide potential window, and simple electrode design. Compared with gold or platinum electrodes, surface modification is difficult because the carbon surface is chemically or physically stable. Oxygen plasma (O2) can easily produce carboxyl groups on the carbon surface, which act as scaffolds for covalent bonds. However, the effect of O2-plasma treatment on electrode performance remains to be investigated from an electrochemical perspective, and sensor performance can be improved by clarifying the surface conditions of plasma-treated biosensors. In this research, we compared antibody modification by plasma treatment and physical adsorption, using our novel immunosensor based on gold nanoparticles (AuNPs). Consequently, the O2-plasma treatment produced carboxyl groups on the electrode surface that changed the electrochemical properties owing to electrostatic interactions. In this study, we compared the following four cases of SPCE modification: O2-plasma-treated electrode/covalent-bonded antibody (a); O2-plasma-treated electrode/physical adsorbed antibody (b); bare electrode/covalent-bonded antibody (c); and bare electrode/physical absorbed antibody (d). The limits of detection (LOD) were 0.50 ng/mL (a), 9.7 ng/mL (b), 0.54 ng/mL (c), and 1.2 ng/mL (d). The slopes of the linear response range were 0.039, 0.029, 0.014, and 0.022. The LOD of (a) was 2.4 times higher than the conventional condition (d), The slope of (a) showed higher sensitivity than other cases (b~d). This is because the plasma treatment generated many carboxyl groups and increased the number of antibody adsorption sites. In summary, the O2-plasma treatment was found to modify the electrode surface conditions and improve the amount of antibody modifications. In the future, O2-plasma treatment could be used as a simple method for modifying various molecular recognition elements on printed carbon electrodes.


  • Open Access

    Surface Modification of Screen-Printed Carbon Electrode through Oxygen Plasma to Enhance Biosensor Sensitivity

    by Shuto Osaki, Masato Saito, Hidenori Nagai, Eiichi Tamiya

    Screen-printed carbon electrode (SPCE) is a useful technique that has been widely used in the practical application of biosensors oriented to point-of-care testing (POCT) due to its characteristics of cost-effectiveness, disposability, miniaturization, wide potential window, and easy of electrode design. Compared with gold or platinum electrodes, surface modification is difficult because the carbon surface is chemically or physically stable. Oxygen plasma can easily produce carboxyl groups on the carbon surface, which act as scaffolds for covalent bonds. However, the effect of O2-plasma treatment on electrode performance remains to be investigated from an electrochemical perspective, and sensor performance can be improved by clarifying the surface conditions of plasma treated biosensors. In this research, we compared antibody modification by plasma treated and physical adsorption, using our original immunosensor based on gold nanoparticles (AuNPs). Consequently, the O2-plasma treatment produced carboxyl groups on the electrode surface, which changed the electrochemical properties owing to electrostatic interactions. It was also found that the surface became hydrophilic, inhibiting non-specific antigen adsorption. The sensitivity was 6.5 times higher than the Limit of Detection (LOD) using physical adsorption.


  • EIS and Amperometric Analysis of Gold Nanoparticle Probes on the Immunosensor Surface

    by Shuto Osaki, Wilfred Villariza Espulgar, Masato Saito, Eiichi Tamiya

    [Introduction] Biosensing systems with integrated nanomaterials have revolutionized technological advancements in recent decades. Gold nanoparticles (AuNPs) in particular have been widely used in electrochemical sensors owing to their stability and unique characteristics. Previously, we developed biosensors that utilize the redox activity of AuNPs. Briefly, antibody-modified AuNPs not only hold secondary antibodies to react with antigens and primary antibodies on the electrode but also supply redox signals. We specially call this biosensing method Gold-Linked Electrochemical ImmunoAssay (GLEIA). In recent years, GLEIA has evolved uniquely in combination with other nanomaterials. However, information regarding the optimal electrochemical measurement conditions and the relationship between the electrode surface and AuNPs remain unknown. In this study, we quantitatively determined kinetic parameters such as the diffusion coefficient and electron transfer rate in the redox reaction of AuNPs on disposable screen-printed electrodes. Furthermore, the relationship between the addition of antibodies and the decrease in the determined parameters could be deduced. This is useful for the determination of the fine balance between the sensitivity and specificity. [Experimental] Electrochemical characteristics of AuNPs were performed using the following method, where 2 µL of AuNPs solution was dropped onto the working electrode and allowed to dry spontaneously. The number of AuNPs on each electrode was calculated from the datasheet (2.6 x 1010 particles/mL, O.D. 520 =1.0), and all nanoparticles were assumed to have dried on the working electrode. To characterize the reduction current, the AuNPs on the electrode underwent a pre-oxidation process, followed by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) to evaluate the reduction current. The pre-oxidation condition was set at 1.2 V for 40 s, which was considered optimal for immunoassays. To evaluate the concentration response, 2 µL of the AuNPs solution was diluted with ultrapure water and poured and allowed to dry on the working electrode, pre-oxidized in 2 M KCl solution, and DPV measurements were performed. This experiment was also performed on an antibody-modified electrode, and the differences between the modified and unmodified electrodes were established. The same DPV measurements were performed using antibody-modified AuNPs (Ab-AuNPs). For immunoassay, IgA was reacted with a secondary antibody and incubated dropwise on an electrode. After washing, electrochemical measurements were performed [Results and Discussion] We investigated the influence of the DPV parameters and electrode surface conditions on a biosensor for the redox reaction of AuNPs. CV and classical theory were used to investigate the reduction kinetics of the AuNPs’ reduction after oxidation. The diffusion coefficient and electron transfer rate, which are related to sensor performance, were significantly reduced in the presence of antibodies and blocking agents on the electrode surface. This was due to the interaction between proteins and gold ions, and the effect of the electrode surface on sensitivity was evaluated using electrochemical reaction rates. Next, the influence of the biosensor on sensitivity was examined by focusing on the pulse amplitude of the DPV, and the increase in signal current coupled to increase in pulse amplitude was confirmed. The signal of AuNPs relative to the blank sample was of particular interest. Theoretically, changing the pulse potential above 100 mV does not change the current values obtained; however, in this study, a significant difference was observed between 150 mV and 100 mV. This was presumably due to the detection of nonspecific adsorption of antibodies that could not be detected under conventional conditions, suggesting the use of a more sensitive biosensor. This study provides evidence for fabrication of an IgA sensor with an improved Limit of detection (LOD) by optimizing pulse amplitude. Limits of detection (LOD) were obtained as 5.0 fmol/L (M) for AuNPs on a bare electrode, 0.1 pM for AuNPs on an antibody-modified electrodes, and 9.3 pM for AuNPs after immunoassay, allowing discussion of the given principle limits and actual biosensor performance (Figure). Under optimal conditions, the electrochemical biosensor achieved nearly two-fold signal amplification using a reduction current after AuNPs oxidation. These findings will allow the investigation of the kinetics of AuNPs on electrodes consisting of different materials to further elucidate the framework for improved sensitivity. Figure 1

  • Open Access

    Development of Nano–Micro Fused LSPR Chip for In Situ Single-Cell Secretion Analysis

    by Yuhei Terada, Ain Obara, Jonathan Campos Briones, Xi Luo, Wilfred Villariza Espulgar, Masato Saito, Hyota Takamatsu, Eiichi Tamiya

    Single-cell analysis has become increasingly important in uncovering cell heterogeneity, which has great implications in medicine and biology for a deep understanding of cell characteristics. Owing to its significance, it is vital to create novel devices that can reveal special or unique cells. In this work, we developed a single-cell secretion detection chip consisting of microwells that can trap single cells. Each well is surrounded by Au nanopillars capable of localized surface plasmon resonance (LSPR) measurement. Using microfabrication and nanofabrication techniques, Au nanopillar and microwell structures were fabricated on a COP film. The Au nanopillar was modified with IL-6 antibodies for the direct detection of single-cell secreted IL-6 via LSPR absorbance peak shift. Specific IL-6 detection was successfully demonstrated using a null and IL-6 oversecreting Jurkat cell. A high single-cell trapping efficiency of over 80% was also achieved. Overall, the development of this single-cell secretion detection chip with a simple LSPR measurement setup represents a significant development in the field of cell biology and immunology, providing researchers with a powerful tool for studying individual cells and their secreted cytokines, and is useful for point-of-care testing (POCT) diagnostics.


  • Open Access

    Novel Glycolipid Chips with a Double Layer of Au Nanoparticles for Biological Toxin Detection

    by Hirotaka Uzawa, Takehiro Nagatsuka, Yasuo Seto, Yoshihiro Nishida, Masato Saito, Eiichi Tamiya


  • Linking antigen specific T-cell dynamics in a microfluidic chip to single cell transcription patterns

    by Hiroki Ide, Taiki Aoshi, Masato Saito, Wilfred Villariza Espulgar, Jonathan Campos Briones, Masahito Hosokawa, Hiroko Matsunaga, Koji Arikawa, Haruko Takeyama, Shohei Koyama, et al.


  • Open Access

    Assembly of Glycochips with Mammalian GSLs Mimetics toward the On-site Detection of Biological Toxins

    by Hirotaka Uzawa, Satoshi Kondo, Takehiro Nagatsuka, Hajime Miyaguchi, Yasuo Seto, Aguri Oshita, Hirofumi Dohi, Yoshihiro Nishida, Masato Saito, Eiichi Tamiya


  • Au-Capped Nanopillar Immobilized with a Length-Controlled Glycopolymer for Immune-Related Protein Detection

    by Yuhei Terada, Ain Obara, Hyota Takamatsu, Wilfred Villariza Espulgar, Masato Saito, Eiichi Tamiya

    A Au-capped nanopillar chip was prepared using nanoimprint lithography (NIL) and Au sputtering onto a cyclo-olefin polymer film. The Au surface of the chip exerting localized surface plasmon resonance (LSPR) phenomena was immobilized with a glycopolymer for the detection of cytokines. The glycopolymers were synthesized by reversible addition-fragmentation chain transfer (RAFT) polymerization for controlled polymer chain length, and thiol-terminated glycopolymers with chain lengths of 20-, 100-, and 200-mers were designed. The thickness of the biomolecular layer on the Au surface was controlled by changing the polymer chain length of the immobilized glycopolymer, and the absorption of proteins onto the Au surface was detected by the shift of absorbance peak wavelength. The value of absorbance peak wavelength shift by protein adsorption increased as the glycopolymer layer thickness became thinner. This difference in LSPR signal response was remarkable for cytokine recognition compared to larger proteins. It was shown that controlling the biomolecular layer thickness was effective for the detection of small proteins, and our research suggested the usefulness of the controlled glycopolymer surface as a molecular recognition material for cytokine detection.


  • Gold Nanocatalysts Towards Digital Sensing Probes with Electrochemiluminescence Based Micro Electrodes Array

    by Kouhei Nagano, Yuhei Terada, Akiko Araki, Shuto Osaki, Masato Saito, Eiichi Tamiya

    The authors have found that gold nanoparticles (AuNP) function as nanocatalysts for the generation of reactive oxygen species such as hydrogen peroxide from dissolved oxygen in coexistence with tris(hydroxymethyl)aminomethane (Tris) or N‐[tris(hydroxymethyl) methyl]glycine (Tricine) chemicals, and that these can be evaluated by luminol electrochemi‐luminescence (ECL). In the present study, we investigated the effects of reaction time, particle concentration, and temperature on the catalytic properties of gold nanoparticles. Unlike biocatalysts such as enzymes, the gold nanoparticles showed an Arrhenius plot‐like increase in activity with temperature without inactivation. In addition, the catalytic activity of the gold nanoparticles varied with the size and shape of the nanoparticles for spherical gold nanoparticles of different sizes (5, 15, 30, 50 and 400 nm) and the activity per nanoparticle increased with the size and surface area. When compared activity per surface area, 15 nm nanoparticles showed higher activity. We prepared gold nanoparticles with nanoflower (AuNF) structure of approx.200 nm in size which showed higher activity per particle than 400 nm spherical particles. The increase in surface area and the difference in surface condition may have influenced these results. We also prepared microelectrode arrays capable of holding small amounts of nl‐pL test reagents. They showed the possibility of imaging ECL of the activity of gold nanoparticles at the level of tens of nanoparticles which could lead to nanocatalysts as probes for digital analysis.


  • Open Access

    A design and optimization of a high throughput valve based microfluidic device for single cell compartmentalization and analysis

    by Jonathan Briones, Wilfred Espulgar, Shohei Koyama, Hyota Takamatsu, Eiichi Tamiya, Masato Saito

    The need for high throughput single cell screening platforms has been increasing with advancements in genomics and proteomics to identify heterogeneity, unique cell subsets or super mutants from thousands of cells within a population. For real-time monitoring of enzyme kinetics and protein expression profiling, valve-based microfluidics or pneumatic valving that can compartmentalize single cells is advantageous by providing on-demand fluid exchange capability for several steps in assay protocol and on-chip culturing. However, this technique is throughput limited by the number of compartments in the array. Thus, one big challenge lies in increasing the number of microvalves to several thousand that can be actuated in the microfluidic device to confine enzymes and substrates in picoliter volumes. This work explores the design and optimizations done on a microfluidic platform to achieve high-throughput single cell compartmentalization as applied to single-cell enzymatic assay for protein expression quantification. Design modeling through COMSOL Multiphysics was utilized to determine the circular microvalve’s optimized parameters, which can close thousands of microchambers in an array at lower sealing pressure. Multiphysical modeling results demonstrated the relationships of geometry, valve dimensions, and sealing pressure, which were applied in the fabrication of a microfluidic device comprising of up to 5000 hydrodynamic traps and corresponding microvalves. Comparing the effects of geometry, actuation media and fabrication technique, a sealing pressure as low as 0.04 MPa was achieved. Applying to single cell enzymatic assay, variations in granzyme B activity in Jurkat and human PBMC cells were observed. Improvement in the microfluidic chip’s throughput is significant in single cell analysis applications, especially in drug discovery and treatment personalization.