Martin A. Koch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Martin A. Koch has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Jürgen Finsterbusch
Department of Systems Neuroscience · Neuroimage Nord University Medical Center Hamburg‐Eppendorf Hamburg Germany
3 shared publicationsC. Büchel
1 shared publicationC. Weiller
1 shared publicationJ. Finsterbusch
Max Planck Society
1 shared publicationJ. Frahm
Max Planck Society
1 shared publicationU.G. Nolte
Max Planck Society
1 shared publication
Latest Publications
- 14 July 2011
- Published by Wiley in NMR in Biomedicine
- Vol. 24 (10) , 1422-1432
Towards compartment size estimation in vivo based on double wave vector diffusion weighting
It has been shown that double wave vector diffusion weighting, which employs two gradient pulse pairs of independent directions, can provide information about tissue structure that is not easily available otherwise, such as cell size or shape in a tissue sample. One approach to measure cell size is based on the signal difference between parallel and antiparallel gradient orientations at small mixing times between the two diffusion weightings. A major difficulty for in vivo application is the small size of the signal difference if clinical MR systems with limited gradient hardware are employed. In this study, the method is applied to human brain tissue in vivo, using whole‐body gradients. Data are reported for the corticospinal tracts. The characteristics of the observed signal difference between parallel and antiparallel gradient orientations are consistent with both analytical and numerical predictions. As an estimate of pore size, the resulting mean squared radius of gyration of the pores amounts to approximately 4 µm2. An analysis that accounts for the finite values of gradient pulse duration and diffusion time yields a volume contribution‐weighted mean pore diameter of 13 μm if a cylindrical pore shape is assumed. The results demonstrate that the technique can be applied in vivo. Copyright © 2011 John Wiley & Sons, Ltd.
- 14 July 2011
- Published by Wiley in NMR in Biomedicine
- Vol. 24 (10) , 1422-1432
Towards compartment size estimation in vivo based on double wave vector diffusion weighting
It has been shown that double wave vector diffusion weighting, which employs two gradient pulse pairs of independent directions, can provide information about tissue structure that is not easily available otherwise, such as cell size or shape in a tissue sample. One approach to measure cell size is based on the signal difference between parallel and antiparallel gradient orientations at small mixing times between the two diffusion weightings. A major difficulty for in vivo application is the small size of the signal difference if clinical MR systems with limited gradient hardware are employed. In this study, the method is applied to human brain tissue in vivo, using whole‐body gradients. Data are reported for the corticospinal tracts. The characteristics of the observed signal difference between parallel and antiparallel gradient orientations are consistent with both analytical and numerical predictions. As an estimate of pore size, the resulting mean squared radius of gyration of the pores amounts to approximately 4 µm2. An analysis that accounts for the finite values of gradient pulse duration and diffusion time yields a volume contribution‐weighted mean pore diameter of 13 μm if a cylindrical pore shape is assumed. The results demonstrate that the technique can be applied in vivo. Copyright © 2011 John Wiley & Sons, Ltd.
- Open Access
- 24 March 2009
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 62 (1) , 247-254
Numerical simulation of double‐wave vector experiments investigating diffusion in randomly oriented ellipsoidal pores
Double-wave vector diffusion weighting is expected to represent a possibility to acquire information on cell size and shape. In numerical simulations, a theoretical description of the double wave vector-weighted signal is tested in a situation where the approximating assumptions (infinitely short gradient pulses, infinitely long diffusion time, infinitely long or zero delay between diffusion weightings, small gradient moment) are not strictly met. It is shown how the dependence of the signal on the angle between the diffusion gradient directions changes upon varying the delay between the second and the third gradient pulse, and how the measures of pore geometry derived from signal differences between two angles depend on the duration, temporal separation, and amplitude of the gradient pulses. The results indicate that a violation of the approximation conditions due to finite gradient pulse duration and separation generally leads to an underestimation of pore size and pore eccentricity. It is also concluded from the simulations that for pore sizes on the order of 10 μm the investigated effects are in a range that is observable even with whole-body gradient systems. Magn Reson Med, 2009.
- 24 March 2009
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 62 (1) , 247-254
Open AccessNumerical simulation of double‐wave vector experiments investigating diffusion in randomly oriented ellipsoidal pores
Double-wave vector diffusion weighting is expected to represent a possibility to acquire information on cell size and shape. In numerical simulations, a theoretical description of the double wave vector-weighted signal is tested in a situation where the approximating assumptions (infinitely short gradient pulses, infinitely long diffusion time, infinitely long or zero delay between diffusion weightings, small gradient moment) are not strictly met. It is shown how the dependence of the signal on the angle between the diffusion gradient directions changes upon varying the delay between the second and the third gradient pulse, and how the measures of pore geometry derived from signal differences between two angles depend on the duration, temporal separation, and amplitude of the gradient pulses. The results indicate that a violation of the approximation conditions due to finite gradient pulse duration and separation generally leads to an underestimation of pore size and pore eccentricity. It is also concluded from the simulations that for pore sizes on the order of 10 μm the investigated effects are in a range that is observable even with whole-body gradient systems. Magn Reson Med, 2009.
- Open Access
- 17 April 2008
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 60 (1) , 90-101
Compartment size estimation with double wave vector diffusion‐weighted imaging
Double wave vector diffusion weighting uses gradients along two different directions between excitation and acquisition. It has been shown theoretically that for restricted diffusion the signal amplitude in such an experiment can depend on the angle between the two gradient vectors. The highest amplitude is obtained with antiparallel orientation, and the amplitude difference between parallel and antiparallel gradient orientations depends on the compartment size. The validity of this description is experimentally tested for water between polymer beads, for radish, and for porcine spinal cord, using a clinical MR system with limited gradient strength. The results indicate that the phenomenon is observable; however, the size of the signal difference is considerably diminished when compared with theory. This is attributed to violations of the approximating conditions underlying the theoretical description and to free diffusion contributions. It is concluded that the effect could successfully be used as a basis for developing a new noninvasive method for assessing cell size. Magn Reson Med, 2008.
- 17 April 2008
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 60 (1) , 90-101
Open AccessCompartment size estimation with double wave vector diffusion‐weighted imaging
Double wave vector diffusion weighting uses gradients along two different directions between excitation and acquisition. It has been shown theoretically that for restricted diffusion the signal amplitude in such an experiment can depend on the angle between the two gradient vectors. The highest amplitude is obtained with antiparallel orientation, and the amplitude difference between parallel and antiparallel gradient orientations depends on the compartment size. The validity of this description is experimentally tested for water between polymer beads, for radish, and for porcine spinal cord, using a clinical MR system with limited gradient strength. The results indicate that the phenomenon is observable; however, the size of the signal difference is considerably diminished when compared with theory. This is attributed to violations of the approximating conditions underlying the theoretical description and to free diffusion contributions. It is concluded that the effect could successfully be used as a basis for developing a new noninvasive method for assessing cell size. Magn Reson Med, 2008.
- 1 September 2002
- Published by Elsevier in NeuroImage
- Vol. 17 (1) , 497-506
Distortion-free Diffusion Tensor Imaging of Cranial Nerves and of Inferior Temporal and Orbitofrontal White Matter
- 1 September 2002
- Published by Elsevier in NeuroImage
- Vol. 17 (1) , 497-506
Distortion-free Diffusion Tensor Imaging of Cranial Nerves and of Inferior Temporal and Orbitofrontal White Matter