Bhim Charan Meikap
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bhim Charan Meikap has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Sudipto Chakraborty
Department of Chemical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, India
6 shared publications - Ashwin Wasudeo Patwardhan
Institute of Chemical Technology, Mumbai, India
2 shared publications Dipa Das
A Department of Chemical Engineering , Indian Institute of Technology (IIT) Kharagpur , West Bengal , India
2 shared publications- Jaya Narayan Sahu
University of Stuttgart, Institute of Chemical Technology, Faculty of Chemistry, D-70550 Stuttgart, Germany; South Ural State University (National Research University), Chelyabinsk, Russian Federation
2 shared publications Mitali Das
Department of Chemical Engineering, Indian Institute of Technology (IIT), Kharagpur, Midnapur(W), West Bengal, India
2 shared publicationsR. K. Saha
Department of Chemical Engineering, Indian Institute of Technology (IIT), Kharagpur, Midnapur(W), West Bengal, India
2 shared publications
Latest Publications
- 28 October 2019
- Published by Taylor & Francis in Mineral Processing and Extractive Metallurgy Review
- Vol. 41 (6) , 370-380
A Scale-up Approach to Produce Highly Reactive Iron Ore Catalyzed Coke for Blast Furnace Operation
The production and analysis of highly reactive Fe catalyzed coke through briquetting route were carried out in this work. The utilization of highly reactive coke in steel making is an alternative process to reduce energy consumption and CO2 emissions in a blast furnace. A scale-up approach is carried out by first optimization of parameters in laboratory scale and then implementing those results in the 7 Kg stamp charge coke oven. The experimentation was carried out through the design of experiments by Taguchi method L16 orthogonal array taking five factors with four levels associated with each parameter. Statistical analysis shows that binder percentage has the maximum contribution in the strength of briquette with iron ore percentage having the least effect. Reactivity analysis shows iron ore addition increases the reactivity of coke around 94.9%, indicating a self-reducing property of iron-oxide. CRI and CSR indexes were found to be 52.3% and 3.2%, for 10% addition of iron ore in a blend which shows the increased reactivity of produced coke. Also, this study establishes an important interrelation and validation of results at the laboratory and in the large scale stamp charge oven test.
- 28 October 2019
- Published by Taylor & Francis in Mineral Processing and Extractive Metallurgy Review
- Vol. 41 (6) , 370-380
A Scale-up Approach to Produce Highly Reactive Iron Ore Catalyzed Coke for Blast Furnace Operation
The production and analysis of highly reactive Fe catalyzed coke through briquetting route were carried out in this work. The utilization of highly reactive coke in steel making is an alternative process to reduce energy consumption and CO2 emissions in a blast furnace. A scale-up approach is carried out by first optimization of parameters in laboratory scale and then implementing those results in the 7 Kg stamp charge coke oven. The experimentation was carried out through the design of experiments by Taguchi method L16 orthogonal array taking five factors with four levels associated with each parameter. Statistical analysis shows that binder percentage has the maximum contribution in the strength of briquette with iron ore percentage having the least effect. Reactivity analysis shows iron ore addition increases the reactivity of coke around 94.9%, indicating a self-reducing property of iron-oxide. CRI and CSR indexes were found to be 52.3% and 3.2%, for 10% addition of iron ore in a blend which shows the increased reactivity of produced coke. Also, this study establishes an important interrelation and validation of results at the laboratory and in the large scale stamp charge oven test.
- 15 August 2019
- Published by Taylor & Francis in Particulate Science and Technology
- Vol. 38 (8) , 999-1011
Experimental hydrodynamic and bed characteristics of co-current gas-liquid-solid three phase semifluidization with liquid as the continuous phase
In this study, hydrodynamic parameters such as minimum liquid phase fluidization velocity semifluidization velocity pressure drop and height of top packed bed formation of a co-current gas-liquid -solid multiphase semifluidized bed were studied using the liquid as the continuous phase and air as the dispersed phase. Air, water, and acrylic beads of various sizes were used to represent the gas, liquid, and solid phases, respectively. The experiments were conducted in a vertical perspex column. The liquid and gas was co-currently fed into the column with varying flow rate. The column has three sections comprising of gas-liquid release section, main section, and gas-liquid distributor section, respectively. The significant outcomes of this study are reduced minimum fluidization velocity ranging from 0.004 to 0.01 m/s and minimum semifluidization velocity of 0.032–0.006 m/s compared to reported high values. Maximum bed pressure drop was found to be 5.6 kPa. Empirical mathematical correlations that represent the hydrodynamic and bed characteristics were developed from the experimental data which are also a new aspect of this study. Model results fitted well to the experimental values and the values obtained are quite useful for the various industrial application.- 15 August 2019
- Published by Taylor & Francis in Particulate Science and Technology
- Vol. 38 (8) , 999-1011
Experimental hydrodynamic and bed characteristics of co-current gas-liquid-solid three phase semifluidization with liquid as the continuous phase
In this study, hydrodynamic parameters such as minimum liquid phase fluidization velocity semifluidization velocity pressure drop and height of top packed bed formation of a co-current gas-liquid -solid multiphase semifluidized bed were studied using the liquid as the continuous phase and air as the dispersed phase. Air, water, and acrylic beads of various sizes were used to represent the gas, liquid, and solid phases, respectively. The experiments were conducted in a vertical perspex column. The liquid and gas was co-currently fed into the column with varying flow rate. The column has three sections comprising of gas-liquid release section, main section, and gas-liquid distributor section, respectively. The significant outcomes of this study are reduced minimum fluidization velocity ranging from 0.004 to 0.01 m/s and minimum semifluidization velocity of 0.032–0.006 m/s compared to reported high values. Maximum bed pressure drop was found to be 5.6 kPa. Empirical mathematical correlations that represent the hydrodynamic and bed characteristics were developed from the experimental data which are also a new aspect of this study. Model results fitted well to the experimental values and the values obtained are quite useful for the various industrial application.- Open Access
- 23 July 2019
- Published by Springer Nature in International Journal of Coal Science & Technology
- Vol. 6 (3) , 445-458
Removal of CO2 in a multistage fluidized bed reactor by amine impregnated activated carbon: optimization using response surface methodology
- 23 July 2019
- Published by Springer Nature in International Journal of Coal Science & Technology
- Vol. 6 (3) , 445-458
Open AccessRemoval of CO2 in a multistage fluidized bed reactor by amine impregnated activated carbon: optimization using response surface methodology
- 30 January 2018
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 53 (7) , 601-608
Removal of fluoride from wastewater using HCl-treated activated alumina in a ribbed hydrocyclone separator
Excessive fluoride concentration in wastewater is a major health concern worldwide. The main objective of wastewater treatment is to allow industrial effluents to be disposed of without danger to the human health and the natural environment. In this current study, experiments have been conducted to remove fluoride from aqueous solution using alumina and HCl (Hydrochloric acid) treated activated alumina in a continuous mode. A spiral rib was introduced in the cylindrical part of the conventional hydrocyclone to increase the performance, and the new hydrocyclone is dubbed as ribbed hydrocyclone. Experiments were carried out to analyze the performance of the ribbed hydrocyclone and compared the results with the conventional hydrocyclone of the same dimension. The efficiency of conventional and ribbed hydrocyclone at a slurry flow rate of 50 LPM (liter per minute) for the solid concentration of 1.4 wt% were 80% and 93.5% respectively. The cut size d50 of the conventional and ribbed hydrocyclone was 18 µm and 13 µm respectively at a slurry velocity of 50 LPM. Fluoride removal efficiency using alumina and HCl-treated alumina was also investigated in a continuous mode by the ribbed hydrocyclone. Maximum fluoride removal efficiency was 49.5%, and 80% for alumina and HCl-treated alumina for the initial concentration of 10 mg/L at a slurry flow rate of 50 LPM.
- 30 January 2018
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 53 (7) , 601-608
Removal of fluoride from wastewater using HCl-treated activated alumina in a ribbed hydrocyclone separator
Excessive fluoride concentration in wastewater is a major health concern worldwide. The main objective of wastewater treatment is to allow industrial effluents to be disposed of without danger to the human health and the natural environment. In this current study, experiments have been conducted to remove fluoride from aqueous solution using alumina and HCl (Hydrochloric acid) treated activated alumina in a continuous mode. A spiral rib was introduced in the cylindrical part of the conventional hydrocyclone to increase the performance, and the new hydrocyclone is dubbed as ribbed hydrocyclone. Experiments were carried out to analyze the performance of the ribbed hydrocyclone and compared the results with the conventional hydrocyclone of the same dimension. The efficiency of conventional and ribbed hydrocyclone at a slurry flow rate of 50 LPM (liter per minute) for the solid concentration of 1.4 wt% were 80% and 93.5% respectively. The cut size d50 of the conventional and ribbed hydrocyclone was 18 µm and 13 µm respectively at a slurry velocity of 50 LPM. Fluoride removal efficiency using alumina and HCl-treated alumina was also investigated in a continuous mode by the ribbed hydrocyclone. Maximum fluoride removal efficiency was 49.5%, and 80% for alumina and HCl-treated alumina for the initial concentration of 10 mg/L at a slurry flow rate of 50 LPM.
- 24 July 2017
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 52 (12) , 1164-1172
Optimization of process condition for the preparation of amine-impregnated activated carbon developed for CO2 capture and applied to methylene blue adsorption by response surface methodology
The present research describes the optimal adsorption condition for methylene blue (MB). The adsorbent used here was monoethanol amine-impregnated activated carbon (MEA-AC) prepared from green coconut shell. Response surface methodology (RSM) is the multivariate statistical technique used for the optimization of the process variables. The central composite design is used to determine the effect of activation temperature, activation time and impregnation ratio on the MB removal. The percentage (%) MB adsorption by MEA-AC is evaluated as a response of the system. A quadratic model was developed for response. From the analysis of variance, the factor which was the most influential on the experimental design response has been identified. The optimum condition for the preparation of MEA-AC from green coconut shells is the temperature of activation 545.6°C, activation time of 41.64 min and impregnation ratio of 0.33 to achieve the maximum removal efficiency of 98.21%. At the same optimum parameter, the % MB removal from the textile-effluent industry was examined and found to be 96.44%.
- 24 July 2017
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 52 (12) , 1164-1172
Optimization of process condition for the preparation of amine-impregnated activated carbon developed for CO2 capture and applied to methylene blue adsorption by response surface methodology
The present research describes the optimal adsorption condition for methylene blue (MB). The adsorbent used here was monoethanol amine-impregnated activated carbon (MEA-AC) prepared from green coconut shell. Response surface methodology (RSM) is the multivariate statistical technique used for the optimization of the process variables. The central composite design is used to determine the effect of activation temperature, activation time and impregnation ratio on the MB removal. The percentage (%) MB adsorption by MEA-AC is evaluated as a response of the system. A quadratic model was developed for response. From the analysis of variance, the factor which was the most influential on the experimental design response has been identified. The optimum condition for the preparation of MEA-AC from green coconut shells is the temperature of activation 545.6°C, activation time of 41.64 min and impregnation ratio of 0.33 to achieve the maximum removal efficiency of 98.21%. At the same optimum parameter, the % MB removal from the textile-effluent industry was examined and found to be 96.44%.
- Open Access
- 1 June 2017
- Published by Elsevier in South African Journal of Chemical Engineering
- Vol. 23, 91-97
Hydrodynamic characteristics of a three-stage dual-flow sieve plate scrubber
- 1 June 2017
- Published by Elsevier in South African Journal of Chemical Engineering
- Vol. 23, 91-97
Open AccessHydrodynamic characteristics of a three-stage dual-flow sieve plate scrubber
- 17 May 2017
- Published by Taylor & Francis in Mineral Processing and Extractive Metallurgy Review
- Vol. 39 (1) , 59-67
Removal of ash from low grade Indian coal by chemical leaching technique
In this work leaching of low grade Indian coal was investigated. Coal samples of pre-treated and treated were characterized to quantify the quality of coal. An attempt has been made in this work to reduce the mineral matter from low grade coal of particle size 250 μm by leaching with H2SO4, HCl, Na2CO3 and NaOH solution as leaching agent at a temperature of 100°C for 3 h. It was found that the final ash content of treated coal was 22% from 38% of ash of feed raw coal by NaOH treatment alone compared to rest of the solvents.
- 17 May 2017
- Published by Taylor & Francis in Mineral Processing and Extractive Metallurgy Review
- Vol. 39 (1) , 59-67
Removal of ash from low grade Indian coal by chemical leaching technique
In this work leaching of low grade Indian coal was investigated. Coal samples of pre-treated and treated were characterized to quantify the quality of coal. An attempt has been made in this work to reduce the mineral matter from low grade coal of particle size 250 μm by leaching with H2SO4, HCl, Na2CO3 and NaOH solution as leaching agent at a temperature of 100°C for 3 h. It was found that the final ash content of treated coal was 22% from 38% of ash of feed raw coal by NaOH treatment alone compared to rest of the solvents.
- 16 February 2017
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 52 (6) , 515-523
Removal of H2S pollutant from gasifier syngas by a multistage dual-flow sieve plate column wet scrubber
The objective of this study was to observe the performance of a lab-scale three-stage dual-flow sieve plate column scrubber for hydrogen sulfide (H2S) gas removal from a gas stream, in which the H2S concentration was similar to that of gasifier syngas. The tap water was used as scrubbing liquid. The gas and liquid were operated at flow rates in the range of 16.59 × 10−4–27.65 × 10−4 Nm3/s and 20.649 × 10−6–48.183 × 10−6 m3/s, respectively. The effects of gas and liquid flow rates on the percentage removal of H2S were studied at 50–300 ppm inlet concentrations of H2S. The increase in liquid flow rate, gas flow rate and inlet H2S concentration increased the percentage removal of H2S. The maximum of 78.88% removal of H2S was observed at 27.65 × 10−4 Nm3/s gas flow rate and 48.183 × 10−6 m3/s liquid flow rate for 300 ppm inlet concentration of H2S. A model has also been developed to predict the H2S gas removal by using the results from the experiments and adding the parameters that affect the scrubber's performance. The deviations between experimental and predicted H2S percentage removal values were observed as less than 16%.
- 16 February 2017
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 52 (6) , 515-523
Removal of H2S pollutant from gasifier syngas by a multistage dual-flow sieve plate column wet scrubber
The objective of this study was to observe the performance of a lab-scale three-stage dual-flow sieve plate column scrubber for hydrogen sulfide (H2S) gas removal from a gas stream, in which the H2S concentration was similar to that of gasifier syngas. The tap water was used as scrubbing liquid. The gas and liquid were operated at flow rates in the range of 16.59 × 10−4–27.65 × 10−4 Nm3/s and 20.649 × 10−6–48.183 × 10−6 m3/s, respectively. The effects of gas and liquid flow rates on the percentage removal of H2S were studied at 50–300 ppm inlet concentrations of H2S. The increase in liquid flow rate, gas flow rate and inlet H2S concentration increased the percentage removal of H2S. The maximum of 78.88% removal of H2S was observed at 27.65 × 10−4 Nm3/s gas flow rate and 48.183 × 10−6 m3/s liquid flow rate for 300 ppm inlet concentration of H2S. A model has also been developed to predict the H2S gas removal by using the results from the experiments and adding the parameters that affect the scrubber's performance. The deviations between experimental and predicted H2S percentage removal values were observed as less than 16%.
- 24 May 2016
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 51 (10) , 870-876
Removal of fly-ash and dust particulate matters from syngas produced by gasification of coal by using a multi-stage dual-flow sieve plate wet scrubber
In this work, fly-ash water scrubbing experiments were conducted in a three-stage lab-scale dual-flow sieve plate scrubber to observe the performance of scrubber in fly-ash removal at different operating conditions by varying the liquid rate, gas rate and inlet fly-ash loading. The percentage of fly-ash removal efficiency increases with increase in inlet fly-ash loading, gas flow rate and liquid flow rate, and height of the scrubber; 98.55% maximum percentage of fly-ash removal efficiency (ηFA) is achieved at 19.36 × 10−4 Nm3/s gas flow rate (QG) and 48.183 × 10−6 m3/s liquid flow rate (QL) at 25 × 10−3 kg/Nm3 inlet fly-ash loading (CFA,i). A model has also been developed for the prediction of fly-ash removal efficiency of the column using the experimental results. The predicted values calculated using the correlation matched well with the experimental results. Deviations observed between the experimental and the predicted values were less than 20%.
- 24 May 2016
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 51 (10) , 870-876
Removal of fly-ash and dust particulate matters from syngas produced by gasification of coal by using a multi-stage dual-flow sieve plate wet scrubber
In this work, fly-ash water scrubbing experiments were conducted in a three-stage lab-scale dual-flow sieve plate scrubber to observe the performance of scrubber in fly-ash removal at different operating conditions by varying the liquid rate, gas rate and inlet fly-ash loading. The percentage of fly-ash removal efficiency increases with increase in inlet fly-ash loading, gas flow rate and liquid flow rate, and height of the scrubber; 98.55% maximum percentage of fly-ash removal efficiency (ηFA) is achieved at 19.36 × 10−4 Nm3/s gas flow rate (QG) and 48.183 × 10−6 m3/s liquid flow rate (QL) at 25 × 10−3 kg/Nm3 inlet fly-ash loading (CFA,i). A model has also been developed for the prediction of fly-ash removal efficiency of the column using the experimental results. The predicted values calculated using the correlation matched well with the experimental results. Deviations observed between the experimental and the predicted values were less than 20%.
- 29 April 2016
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 51 (9) , 769-775
Removal of CO2in a multistage fluidized bed reactor by diethanol amine impregnated activated carbon
To mitigate the emission of carbon dioxide (CO2), we have developed and designed a four-stage fluidized bed reactor. There is a counter current exchange between solid adsorbent and gas flow. In this present investigation diethanol amine (DEA) impregnated activated carbon made from green coconut shell was used as adsorbent. This type of adsorbent not only adsorbs CO2 due to the presence of pore but also chemically reacts with CO2 and form secondary zwitterions. Sampling and analysis of CO2 was performed using Orsat apparatus. The effect of initial CO2 concentration, gas velocity, solid rate, weir height etc. on removal efficiency of CO2 have been investigated and presented. The percentage removal of CO2 has been found close to 80% under low gas flow rate (0.188 m/s), high solid flow rate (4.12 kg/h) and weir height of 50 mm. From this result it has been found out that multistage fluidized bed reactor may be a suitable equipment for removal of CO2 from flue gas.
- 29 April 2016
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 51 (9) , 769-775
Removal of CO2in a multistage fluidized bed reactor by diethanol amine impregnated activated carbon
To mitigate the emission of carbon dioxide (CO2), we have developed and designed a four-stage fluidized bed reactor. There is a counter current exchange between solid adsorbent and gas flow. In this present investigation diethanol amine (DEA) impregnated activated carbon made from green coconut shell was used as adsorbent. This type of adsorbent not only adsorbs CO2 due to the presence of pore but also chemically reacts with CO2 and form secondary zwitterions. Sampling and analysis of CO2 was performed using Orsat apparatus. The effect of initial CO2 concentration, gas velocity, solid rate, weir height etc. on removal efficiency of CO2 have been investigated and presented. The percentage removal of CO2 has been found close to 80% under low gas flow rate (0.188 m/s), high solid flow rate (4.12 kg/h) and weir height of 50 mm. From this result it has been found out that multistage fluidized bed reactor may be a suitable equipment for removal of CO2 from flue gas.