William Neil Charman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
William Neil Charman has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- David Andrew. Atchison
Queensland University of Technology
4 shared publications Matt Jaskulski
School of Optometry Indiana University Indiana USA
2 shared publications- Ankit Mathur
Institute of Health & Biomedical Innovation and School of Optometry & Vision Science, Queensland University of Technology, Brisbane, Australia
1 shared publication - Anthony P. Cullen
University of Waterloo, School of Optometry, Waterloo, ON, Canada
1 shared publication G. Walsh
Department of Ophthalmic Optics, Glasgow College, Scotland
1 shared publicationGordon Heron
Vision Sciences Glasgow Caledonian University Glasgow UK
1 shared publication
Latest Publications
- Open Access
- 17 September 2025
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 45 (7) , 1912-1923
Myopia control and modulation transfer functions for multisegment spectacle lenses
Introduction: Multisegment (MS) spectacle lenses, providing a distance correction with a clear central area and by having an array of small, positively powered lenslets in the periphery of the front surface, have proved effective in slowing childhood myopia progression. Debate continues as to whether their mechanism of action is due to through‐focus effects or to the image contrast changes due to the inclusion of the lenslets. This study explores the second possibility by modelling the performance of a combined MS lens‐eye optical system in terms of its modulation transfer function (MTF) under various conditions. Methods: The optical design program Ansys Zemax OpticsStudio was used to determine distance MTFs for the combination of either a single‐vision or a Hoya MiyoSmart MS lens with a 4 D myopic eye model. Conditions included axial and peripheral objects with co‐axial lens and eye, and rotating the eye away from the lens axis to observe objects through the lenslet‐covered region of the lens. Visual resolution under each condition was estimated. Results: Observing objects through the lenslet array lowered modulation transfer in comparison with that given by the single‐vision lens, especially as spatial frequency increased. In peripheral observation at a field angle of approximately 32.5 degrees, imagery was poor. Foveal image quality was better with axial viewing through the clear MS lens centre than when the eye was rotated by approximately 30 degrees. Conclusions: Optimal visual resolution during MS lens wear is achieved when fixating through the clear, central area of the lens. Under these circumstances, objects at 20–50 degrees from fixation are seen through the lenslet‐covered region of the carrier which produces a low‐pass spatial frequency filtering effect. Here, visual resolution is limited to a few cycles per degree so that any growth control mechanism must rely on low spatial frequency information.
- 17 September 2025
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 45 (7) , 1912-1923
Open AccessMyopia control and modulation transfer functions for multisegment spectacle lenses
Introduction: Multisegment (MS) spectacle lenses, providing a distance correction with a clear central area and by having an array of small, positively powered lenslets in the periphery of the front surface, have proved effective in slowing childhood myopia progression. Debate continues as to whether their mechanism of action is due to through‐focus effects or to the image contrast changes due to the inclusion of the lenslets. This study explores the second possibility by modelling the performance of a combined MS lens‐eye optical system in terms of its modulation transfer function (MTF) under various conditions. Methods: The optical design program Ansys Zemax OpticsStudio was used to determine distance MTFs for the combination of either a single‐vision or a Hoya MiyoSmart MS lens with a 4 D myopic eye model. Conditions included axial and peripheral objects with co‐axial lens and eye, and rotating the eye away from the lens axis to observe objects through the lenslet‐covered region of the lens. Visual resolution under each condition was estimated. Results: Observing objects through the lenslet array lowered modulation transfer in comparison with that given by the single‐vision lens, especially as spatial frequency increased. In peripheral observation at a field angle of approximately 32.5 degrees, imagery was poor. Foveal image quality was better with axial viewing through the clear MS lens centre than when the eye was rotated by approximately 30 degrees. Conclusions: Optimal visual resolution during MS lens wear is achieved when fixating through the clear, central area of the lens. Under these circumstances, objects at 20–50 degrees from fixation are seen through the lenslet‐covered region of the carrier which produces a low‐pass spatial frequency filtering effect. Here, visual resolution is limited to a few cycles per degree so that any growth control mechanism must rely on low spatial frequency information.
- Open Access
- 10 March 2025
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 45 (3) , 790-798
Oblique effects with multisegment spectacle lenses: 2. Ray tracing to determine power corrections
Purpose: Part 1 of the study investigated image quality associated with oblique incidence of light on a multisegment lens (Hoya MiyoSmart) intended to treat myopia development. Part 2 investigates power corrections associated with oblique incidence. Methods: Modelling and ray tracing were carried out with lenses of −4 D distance power and, to a lesser extent, +0.25 D. Ray tracing simulations were done for the lens by itself, an eye model by itself and the combination. These simulations were for the static situation of peripheral vision when the eye looks through the lens centre and for central (foveal) vision when the eye rotates to look at objects away from the lens optical axis. The outcome was power correction of the optics, that is, the difference between the nominal power of the distance correction provided by the carrier lens under specific conditions and the actual power. This was determined across the field to about 45° and across the pupil for certain field angles. Most investigations were performed for distance vision, but some were for near objects with an accommodating version of the model eye. Results: Ignoring intended multisegment effects, the quality of optics associated with peripheral vision was poor. There was considerable astigmatism (cylinder) across the field and high variation in astigmatism across the pupil. The added effects of the lens and eye were similar to those of their combination. For the accommodated eye model with an object at 250 mm, results were similar to those obtained with the unaccommodated model viewing a distant object. For foveal vision with the rotating eye, optics were relatively good with lower levels of astigmatism than for peripheral vision. Conclusion: The results of Part 1, finding considerable effects of the obliquity of incidence associated with peripheral vision and with foveal vision for the rotating eye, were supported by the power corrections.
- 10 March 2025
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 45 (3) , 790-798
Open AccessOblique effects with multisegment spectacle lenses: 2. Ray tracing to determine power corrections
Purpose: Part 1 of the study investigated image quality associated with oblique incidence of light on a multisegment lens (Hoya MiyoSmart) intended to treat myopia development. Part 2 investigates power corrections associated with oblique incidence. Methods: Modelling and ray tracing were carried out with lenses of −4 D distance power and, to a lesser extent, +0.25 D. Ray tracing simulations were done for the lens by itself, an eye model by itself and the combination. These simulations were for the static situation of peripheral vision when the eye looks through the lens centre and for central (foveal) vision when the eye rotates to look at objects away from the lens optical axis. The outcome was power correction of the optics, that is, the difference between the nominal power of the distance correction provided by the carrier lens under specific conditions and the actual power. This was determined across the field to about 45° and across the pupil for certain field angles. Most investigations were performed for distance vision, but some were for near objects with an accommodating version of the model eye. Results: Ignoring intended multisegment effects, the quality of optics associated with peripheral vision was poor. There was considerable astigmatism (cylinder) across the field and high variation in astigmatism across the pupil. The added effects of the lens and eye were similar to those of their combination. For the accommodated eye model with an object at 250 mm, results were similar to those obtained with the unaccommodated model viewing a distant object. For foveal vision with the rotating eye, optics were relatively good with lower levels of astigmatism than for peripheral vision. Conclusion: The results of Part 1, finding considerable effects of the obliquity of incidence associated with peripheral vision and with foveal vision for the rotating eye, were supported by the power corrections.
- Open Access
- 25 February 2025
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 45 (3) , 779-789
Oblique effects with multisegment spectacle lenses: 1. Images of a point object
Introduction: Multisegment (MS) spectacles are intended to slow myopia progression by modifying images falling on the peripheral retina. Some published optical treatments of these lenses assume normal incidence of light at the surfaces, but images falling on the peripheral retina are usually associated with oblique ray pencils. Here, we model representative images of point objects produced by the Hoya MiyoSmart MS spectacle lens when oblique ray pencils are used. Methods: Various imaging aspects of the MS lens alone and in combination with a suitable accommodating eye model for a 4D myope were evaluated using the Optical Design program Ansys Zemax OpticStudio. Configurations studied included object points at vergences of zero and –4 D, with the objects being either on the lens axis or at a field angle of about 30°. The effect on foveal vision of rotating the axis of the eye with respect to that of the lens was also considered. Images of point objects were described in terms of spot diagrams and fast Fourier transform point‐spread functions. Results: Symmetry and overall optical quality of images decreased with the obliquity of the ray pencils, due to the increased off‐axis aberrations of the lens and the eye. Images of near object points were strongly affected by the level of accommodation: optimal retinal image quality occurred when accommodation brought the carrier lens focus close to the retina, rather than that of the lenslets. Conclusions: Attempts to understand why MS lenses slow myopia progression need to consider the way in which through‐focus retinal image quality changes with obliquity of the ray pencils across the visual field and the possible effects of ocular accommodation.
- 25 February 2025
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 45 (3) , 779-789
Open AccessOblique effects with multisegment spectacle lenses: 1. Images of a point object
Introduction: Multisegment (MS) spectacles are intended to slow myopia progression by modifying images falling on the peripheral retina. Some published optical treatments of these lenses assume normal incidence of light at the surfaces, but images falling on the peripheral retina are usually associated with oblique ray pencils. Here, we model representative images of point objects produced by the Hoya MiyoSmart MS spectacle lens when oblique ray pencils are used. Methods: Various imaging aspects of the MS lens alone and in combination with a suitable accommodating eye model for a 4D myope were evaluated using the Optical Design program Ansys Zemax OpticStudio. Configurations studied included object points at vergences of zero and –4 D, with the objects being either on the lens axis or at a field angle of about 30°. The effect on foveal vision of rotating the axis of the eye with respect to that of the lens was also considered. Images of point objects were described in terms of spot diagrams and fast Fourier transform point‐spread functions. Results: Symmetry and overall optical quality of images decreased with the obliquity of the ray pencils, due to the increased off‐axis aberrations of the lens and the eye. Images of near object points were strongly affected by the level of accommodation: optimal retinal image quality occurred when accommodation brought the carrier lens focus close to the retina, rather than that of the lenslets. Conclusions: Attempts to understand why MS lenses slow myopia progression need to consider the way in which through‐focus retinal image quality changes with obliquity of the ray pencils across the visual field and the possible effects of ocular accommodation.
- 1 February 2025
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 45 (2) , 333-336
Phoenix rising: Editing OPO, 1981–1987, volumes 1–7
- 1 February 2025
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 45 (2) , 333-336
Phoenix rising: Editing OPO, 1981–1987, volumes 1–7
- 6 April 2023
- Published by Elsevier
- p. 71-75.e2
Soft Lens Optics
- 1 April 2022
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 45 (2) , 101451
Flitcroft’s model of refractive development in childhood and the possible identification of children at risk of developing significant myopia
- 1 April 2022
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 45 (2) , 101451
Flitcroft’s model of refractive development in childhood and the possible identification of children at risk of developing significant myopia
- 1 April 2018
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 41 (2) , 241-242
Donald FC Loran (1936-2018) Obituary
- 1 April 2018
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 41 (2) , 241-242
Donald FC Loran (1936-2018) Obituary
- Open Access
- 17 October 2017
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 37 (6) , 655-660
Virtual Issue Editorial: Presbyopia – grappling with an age‐old problem
- 17 October 2017
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 37 (6) , 655-660
Open AccessVirtual Issue Editorial: Presbyopia – grappling with an age‐old problem
- 28 December 2016
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 37 (1) , 1-6
Correcting presbyopia: the problem of pupil size
- 28 December 2016
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 37 (1) , 1-6
Correcting presbyopia: the problem of pupil size