NVNienke Visser

Nienke Visser

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nienke Visser has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Late-onset corneal edema after customized crosslinking for progressive keratoconus

    by Magali M.S. Vandevenne, Tos T.J.M. Berendschot, Nienke Visser, Mor M. Dickman, Rudy M.M.A. Nuijts


  • Refraktive Intraokularchirurgie

    by Thomas Kohnen, Mehdi Shajari, Wolfgang J. Mayer, Nienke Visser, Rudy Nuijts, Christoph M. Lwowski, Myriam Böhm, Gerd Auffarth, Ramin Khoramnia, Nino Hirnschall, et al.

  • Top Cited Papers

    Toric intraocular lenses: Historical overview, patient selection, IOL calculation, surgical techniques, clinical outcomes, and complications

    by Nienke Visser, Noël J.C. Bauer, Rudy M.M.A. Nuijts

    We present an overview of currently available toric intraocular lenses (IOLs) and multifocal toric IOLs. Relevant patient selection criteria, IOL calculation issues, and surgical techniques for IOL implantation are discussed. Clinical outcomes including uncorrected visual acuity, residual refractive astigmatism, and spectacle independency, which have been reported for both toric IOLs and multifocal toric IOLs, are reviewed. The incidence of misalignment, the most important complication of toric IOLs, is determined. Finally, future developments in the field of toric IOLs are discussed.


  • Comparability and repeatability of corneal astigmatism measurements using different measurement technologies

    by Nienke Visser, Tos T.J.M. Berendschot, Frenne Verbakel, John de Brabander, Rudy M.M.A. Nuijts

    To determine the comparability and repeatability of corneal astigmatism measurements obtained with different devices and determine the interobserver variability of a new automated keratometer. University Eye Clinic Maastricht, the Netherlands. Prospective cohort study. The right eye of healthy subjects was examined with the following 6 devices: IOLMaster (automated keratometry), Lenstar (automated keratometry), SMI Reference Unit 3 (automated keratometry), Javal (manual keratometry), KR-1W (corneal topography), and Pentacam (Scheimpflug imaging). An experienced operator obtained 3 repeated measurements. An inexperienced operator obtained additional measurements with the SMI Reference Unit 3. Astigmatism vector analysis was used to determine the comparability, repeatability, and interobserver variability. Corneal astigmatism vectors measured by automated, manual, or simulated keratometry were comparable except for the Pentacam equivalent keratometry (K) (P<.001, repeated-measures analysis of variance [ANOVA]). The mean difference between the equivalent K and other K values was 0.18 to 0.29 diopter (D) (P<.05, Hotelling trace multivariate ANOVA). The mean differences between automated, manual, and simulated keratometry were small (≤0.12 D). The within-subject standard deviation ranged from 0.05 D @ 21 degrees (KR-1W) to 0.18 D @ 23 degrees (Lenstar). The SMI Reference Unit showed small mean differences and comparable repeatability between the experienced operator and the inexperienced operator. Vector analysis showed comparable corneal astigmatism measurements using automated, manual, and simulated keratometry. Pentacam equivalent K values were not comparable with those of the other keratometers. The repeatability of astigmatism magnitudes was acceptable; however, the repeatability of astigmatism meridians was moderate. The SMI Reference Unit showed good interobserver variability.


  • Residual Astigmatism Following Toric Intraocular Lens Implantation Related to Pupil Size

    by Nienke Visser, Noël J.C. Bauer, Rudy M.M.A. Nuijts

    PURPOSE: To present two patients with residual astigmatism following toric intraocular lens (IOL) implantation. METHODS: Case reports. RESULTS: A 58-year-old woman underwent toric IOL implantation (spherical power 29.50 diopters [D], cylinder power 3.00 D; SN60T5, Alcon Laboratories Inc) to correct 2.33 D @ 80° of corneal astigmatism. Postoperatively, uncorrected distance visual acuity (UDVA) was 20/30 and corrected distance visual acuity (CDVA) was 20/22 (0 −1.75 × 95), indicating an overcorrection of astigmatism. Slit-lamp examination demonstrated no IOL misalignment. Wavefront aberrometry showed a large pupil diameter (>6 mm) and a lower corneal astigmatism in a 6-mm zone (−1.40 D @ 174°) compared to a 4-mm zone (−2.21 D @ 171°). The second patient, a 60-year-old man, underwent multifocal toric IOL implantation (spherical power 22.50 D, cylinder power 2.25 D; SND1T4, Alcon Laboratories Inc) to correct 1.51 D @ 173° of corneal astigmatism. Postoperatively, UDVA was 20/50 and CDVA was 20/20 (+0.25 −1.00 × 102), indicating an undercorrection of astigmatism. Slit-lamp examination showed no misalignment. CONCLUSIONS: Both cases indicate that unexplained residual astigmatism following toric IOL implantation may be the result of multiple factors: the effect of the spherical power and anterior chamber depth on toric IOL calculations, the effect of posterior corneal astigmatism, and the effect of a large pupil size. The first two issues may be compensated for by improving toric IOL calculations. The latter indicates that pupillometry is indicated in relatively young patients who undergo toric IOL implantation.


  • Vector Analysis of Corneal and Refractive Astigmatism Changes Following Toric Pseudophakic and Toric Phakic IOL Implantation

    by Nienke Visser, Tos T. J. M. Berendschot, Noël J. C. Bauer, Rudy M. M. A. Nuijts

    Purpose.: To determine the efficacy of the astigmatism correction following toric intraocular lens (IOL) and toric phakic IOL (pIOL) implantation in eyes with no previous ocular surgery and in postkeratoplasty (PKP) eyes. In addition, changes in corneal astigmatism were determined. Methods.: Astigmatism was analyzed in 35 eyes with an AcrySof toric IOL, 35 eyes with an Artiflex toric pIOL, 50 eyes with an Artisan toric pIOL, and 40 PKP eyes with an Artisan toric pIOL. Refractive astigmatism was analyzed by using Alpins method. Surgically induced corneal astigmatism (SICA) was determined following a superior 2.2-mm, 3.4-mm, or 5.4-mm incision. Follow-up was 12 months. Results.: Following toric IOL implantation, the index of success was 0.14 and overall residual astigmatism, 0.37 diopter (D). Following toric pIOL implantation, the index of success was 0.32 (Artiflex) and 0.18 (Artisan), and overall residual astigmatism was approximately 0.60 D. In PKP eyes, Artisan pIOLs resulted in an index of success of 0.28 and overall residual astigmatism of 1.56 D. The SICA, following 2.2-mm, 3.4-mm, 5.4-mm (normal eyes), and 5.4-mm (PKP eyes) incisions, was −0.25 ± 0.42 D (P = 0.108), −0.31 ± 0.43 D (P < 0.001), −0.48 ± 0.55 D (P < 0.001), and −0.49 ± 1.48 D (P = 0.035), respectively. Conclusions.: Toric IOLs and pIOLs provide an effective astigmatism correction. Incorporating the SICA into the toric IOL power calculation may further increase their effectiveness. Therefore, incorporation of 0 D, −0.30 D, or −0.50 D of SICA for a 2.2-, 3.4-, or 5.4-mm superior incision, respectively, is recommended.


  • Visual outcomes and patient satisfaction after cataract surgery with toric multifocal intraocular lens implantation

    by Nienke Visser, Rudy M.M.A. Nuijts, Niels E. de Vries, Noël J.C. Bauer

    To evaluate visual outcomes and patient satisfaction after toric multifocal intraocular lens (IOL) implantation in patients with cataract and corneal astigmatism. University Eye Clinic Maastricht, The Netherlands. Cohort study. Patients with cataract, corneal astigmatism, and a motivation for spectacle independency had cataract surgery with implantation of a toric diffractive multifocal IOL (AT Lisa). Three months postoperatively, the uncorrected distance (UDVA), intermediate (UIVA), and near (UNVA) visual acuities; corrected distance, intermediate, and near visual acuities; residual refractive astigmatism; defocus curve; contrast sensitivity; and patient satisfaction were evaluated. Forty-five eyes of 25 patients were enrolled. Postoperatively, the mean UDVA was 0.04 logMAR ± 0.15 (SD) and 98% of eyes achieved a UDVA of 20/40 or better. The mean UNVA was 0.20 ± 0.16 logMAR and the mean UIVA (at 60 cm), 0.40 ± 0.16 logMAR. Residual refractive astigmatism of -1.00 diopter or less was achieved in approximately 90% of eyes. Contrast sensitivity levels were high. Approximately 50% of patients reported moderate glare, halos, and starburst symptoms. Spectacle independency for distance and near vision was achieved by 95% of patients and 79% of patients, respectively. Toric IOL implantation in patients with cataract and corneal astigmatism provided good distance and near visual outcomes and acceptable intermediate visual outcomes, allowing patients with considerable amounts of corneal astigmatism to achieve spectacle independence at distance and near. No author has a financial or proprietary interest in any material or method mentioned. Additional disclosures are found in the footnotes.