José H. Jacobs
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
José H. Jacobs has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Jack Spithoven
Institute for Risk Assessment Sciences, Division of Environmental Epidemiology, Utrecht University, Utrecht, The Netherlands
2 shared publicationsA. Borras-Santos
Centre for Research in Environmental Epidemiology (CREAL); Barcelona Spain
1 shared publicationA. Hyvarinnen
Department Environmental Health; National Institute for Health and Welfare; Kuopio Finland
1 shared publicationD. J. J. Heederik
Division of Environmental Epidemiology; Institute for Risk Assessment Sciences; Utrecht University; Utrecht The Netherlands
1 shared publicationDick J J Heederik
Division of Environmental Epidemiology, Institute for Risk Assessment Sciences, Utrecht University, Utrecht, The Netherlands
1 shared publicationDick J.J. Heederik
Institute for Risk Assessment Sciences, Division of Environmental Epidemiology, Utrecht University, Utrecht, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 6 October 2015
- Published by Springer Nature in BMC Veterinary Research
- Vol. 11 (1) , 1-9
Influence of applying different units of measurement on reporting antimicrobial consumption data for pig farms
Antimicrobial use in livestock is one of the factors contributing to selection and spread of resistant microorganisms in the environment. National veterinary antimicrobial consumption monitoring programs are therefore in place in a number of countries in the European Union. However, due to differences in methodology, results on veterinary antimicrobial consumption from these national monitoring programs cannot be compared internationally. International comparison is highly needed to establish regulations on veterinary antimicrobial use and reducing antimicrobial resistance. The aim of this study was to assess differences in the outcomes on veterinary antimicrobial consumption by applying three different sets of nationally established animal defined daily dosages to the same antimicrobial drug delivery dataset of Dutch pigs in 2012. Delivery information for the complete Dutch pig sector for the year 2012 reported to the Netherlands Veterinary Medicines Authority (SDa) was analysed with three differently and nationally established animal defined daily dosages from the Netherlands and Denmark: the Defined Daily Dosage AnimalNL (DDDANL), the Animal Daily DosageDK (ADDDK) and Defined Animal Daily DosageDK (DADDDK). For each applied Dutch product equivalent, Danish products were identified based on authorization for pigs, active substance (including form), administration route, concentration and dosage regimen. Consumption in number of ADDDK/Y was lower than in number of DDDANL/Y for sows/piglets and finisher pigs, with proportions of 83.3 % and 98.3 %. Use in number of DADDDK/Y was even lower, 79.7 % for sows/piglets and 88.1 % for finisher pigs compared to number of DDDANL/Y. At therapeutic group level proportions of number of DADDDK/Y to number of DDDANL/Y were 63.6-150.4 % (sows/piglets) and 55.6-171.0 % (finisher pigs). Proportions were > 100 % for the polymyxines (sows/piglets 150.4 % and finisher pigs 149.9 %) and the macrolides/lincosamides (finisher pigs 171.0 %). Differences between nationally established animal defined daily dosages caused by different correction factors for long-acting products and national differences in authorized dosages, have a substantial influence on the results of antimicrobial consumption in pigs. To enable international comparison of veterinary antimicrobial consumption data, harmonized units of measurement, animal weights and animal (sub) categories are needed.
- 6 October 2015
- Published by Springer Nature in BMC Veterinary Research
- Vol. 11 (1) , 1-9
Open AccessInfluence of applying different units of measurement on reporting antimicrobial consumption data for pig farms
Antimicrobial use in livestock is one of the factors contributing to selection and spread of resistant microorganisms in the environment. National veterinary antimicrobial consumption monitoring programs are therefore in place in a number of countries in the European Union. However, due to differences in methodology, results on veterinary antimicrobial consumption from these national monitoring programs cannot be compared internationally. International comparison is highly needed to establish regulations on veterinary antimicrobial use and reducing antimicrobial resistance. The aim of this study was to assess differences in the outcomes on veterinary antimicrobial consumption by applying three different sets of nationally established animal defined daily dosages to the same antimicrobial drug delivery dataset of Dutch pigs in 2012. Delivery information for the complete Dutch pig sector for the year 2012 reported to the Netherlands Veterinary Medicines Authority (SDa) was analysed with three differently and nationally established animal defined daily dosages from the Netherlands and Denmark: the Defined Daily Dosage AnimalNL (DDDANL), the Animal Daily DosageDK (ADDDK) and Defined Animal Daily DosageDK (DADDDK). For each applied Dutch product equivalent, Danish products were identified based on authorization for pigs, active substance (including form), administration route, concentration and dosage regimen. Consumption in number of ADDDK/Y was lower than in number of DDDANL/Y for sows/piglets and finisher pigs, with proportions of 83.3 % and 98.3 %. Use in number of DADDDK/Y was even lower, 79.7 % for sows/piglets and 88.1 % for finisher pigs compared to number of DDDANL/Y. At therapeutic group level proportions of number of DADDDK/Y to number of DDDANL/Y were 63.6-150.4 % (sows/piglets) and 55.6-171.0 % (finisher pigs). Proportions were > 100 % for the polymyxines (sows/piglets 150.4 % and finisher pigs 149.9 %) and the macrolides/lincosamides (finisher pigs 171.0 %). Differences between nationally established animal defined daily dosages caused by different correction factors for long-acting products and national differences in authorized dosages, have a substantial influence on the results of antimicrobial consumption in pigs. To enable international comparison of veterinary antimicrobial consumption data, harmonized units of measurement, animal weights and animal (sub) categories are needed.
- 23 September 2013
- Published by Wiley in Indoor Air
- Vol. 24 (2) , 148-157
Endotoxin levels in settled airborne dust in European schools: the HITEA school study
Indoor exposure to microbial agents is known to influence respiratory health. Besides home exposure, exposure in schools can affect respiratory health. In this study, we measured endotoxin in settled dust in primary schools in three European countries from three different geographical regions with different climates. Our aim was to characterize endotoxin levels in primary schools and evaluate associations with potential determinants. Endotoxin levels were repeatedly assessed in 23 schools in Spain (n = 7), the Netherlands (n = 10), and Finland (n = 6) using electrostatic dustfall collectors. In total, 645 measurements were taken in 237 classrooms. Endotoxin levels differed significantly between countries; Dutch schools had the highest levels, while Finnish schools showed the lowest levels. In each country, differences in endotoxin levels were observed between schools and over the sampling periods. Estimates improved after adjustment for sampling period. Factors affecting endotoxin levels in a school differed per country. In general, endotoxin levels were higher in lower grades and in classrooms with higher occupancy. School endotoxin levels may contribute significantly to total endotoxin exposure in children and teachers. As the correlation between the repeated measurements is reasonable, single endotoxin measurements form a reasonable basis for estimating annual endotoxin levels in schools.
- 23 September 2013
- Published by Wiley in Indoor Air
- Vol. 24 (2) , 148-157
Endotoxin levels in settled airborne dust in European schools: the HITEA school study
Indoor exposure to microbial agents is known to influence respiratory health. Besides home exposure, exposure in schools can affect respiratory health. In this study, we measured endotoxin in settled dust in primary schools in three European countries from three different geographical regions with different climates. Our aim was to characterize endotoxin levels in primary schools and evaluate associations with potential determinants. Endotoxin levels were repeatedly assessed in 23 schools in Spain (n = 7), the Netherlands (n = 10), and Finland (n = 6) using electrostatic dustfall collectors. In total, 645 measurements were taken in 237 classrooms. Endotoxin levels differed significantly between countries; Dutch schools had the highest levels, while Finnish schools showed the lowest levels. In each country, differences in endotoxin levels were observed between schools and over the sampling periods. Estimates improved after adjustment for sampling period. Factors affecting endotoxin levels in a school differed per country. In general, endotoxin levels were higher in lower grades and in classrooms with higher occupancy. School endotoxin levels may contribute significantly to total endotoxin exposure in children and teachers. As the correlation between the repeated measurements is reasonable, single endotoxin measurements form a reasonable basis for estimating annual endotoxin levels in schools.
- Open Access
- 25 October 2012
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 42 (2) , 314-322
Endotoxin levels in homes and classrooms of Dutch school children and respiratory health
Several studies describe indoor pollutant exposure in homes and to a lesser extent in schools. Population studies that include both environments are sparse. This study aims to assess endotoxin levels in primary schools and homes of children. Endotoxin was also studied in relation to asthma and sensitisation.10 schools with (index) and without (reference) dampness were selected, based on reports and inspections. Cases and controls were selected from 169 homes based on the presence or absence of asthma-like symptoms of children. Classroom and bedroom airborne settled dust was sampled using electrostatic dust fall collectors.Average endotoxin levels in schools ranged from 2178 to 6914 endotoxin units (EU)·m−2per week compared with 462–1285 EU·m−2per week in homes. After mutual adjustment for home and school endotoxin, school endotoxin was positively associated with nonatopic asthma (OR 1.11, 95% CI 0.97–1.27), while no associations with endotoxin were found at home.The high endotoxin levels in schools compared with homes indicate that exposure at school can contribute considerably to environmental endotoxin exposure of children and teachers. Our results also suggest that endotoxin in schools may be associated with nonatopic asthmatic symptoms in pupils, although the results require reproduction because of the modest sample size.
- 25 October 2012
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 42 (2) , 314-322
Open AccessEndotoxin levels in homes and classrooms of Dutch school children and respiratory health
Several studies describe indoor pollutant exposure in homes and to a lesser extent in schools. Population studies that include both environments are sparse. This study aims to assess endotoxin levels in primary schools and homes of children. Endotoxin was also studied in relation to asthma and sensitisation.10 schools with (index) and without (reference) dampness were selected, based on reports and inspections. Cases and controls were selected from 169 homes based on the presence or absence of asthma-like symptoms of children. Classroom and bedroom airborne settled dust was sampled using electrostatic dust fall collectors.Average endotoxin levels in schools ranged from 2178 to 6914 endotoxin units (EU)·m−2per week compared with 462–1285 EU·m−2per week in homes. After mutual adjustment for home and school endotoxin, school endotoxin was positively associated with nonatopic asthma (OR 1.11, 95% CI 0.97–1.27), while no associations with endotoxin were found at home.The high endotoxin levels in schools compared with homes indicate that exposure at school can contribute considerably to environmental endotoxin exposure of children and teachers. Our results also suggest that endotoxin in schools may be associated with nonatopic asthmatic symptoms in pupils, although the results require reproduction because of the modest sample size.
- 4 August 2012
- Published by BMJ in Occupational and Environmental Medicine
- Vol. 69 (11) , 823-830
Swimming pool attendance and respiratory symptoms and allergies among Dutch children
Objectives To describe associations among swimming, respiratory health, allergen sensitisation and Clara cell protein 16 (CC16) levels in Dutch schoolchildren. Trichloramine levels in swimming pool air were determined to assess potential exposure levels. Methods Respiratory health and pool attendance information was collected from 2359 children, aged 6–13 years. Serum from 419 children was tested for allergen sensitisation and CC16 levels. Trichloramine levels were assessed in nine swimming facilities. Results Trichloramine levels ranged from 0.03 to 0.78 mg/m3 (average 0.21 mg/m3). Reported swimming pool attendance and trichloramine exposure were both not associated with asthma, wheezing, rhinitis or CC16 levels. Birch and house dust mite sensitisation were associated with recent indoor swimming (OR>1.86), but not after considering recent swimming frequency multiplied by trichloramine levels. Sensitisation to house dust mites was associated with frequent baby swimming (ORs=1.75; 95% CI 1.09 to 2.79). Furthermore, sensitisation was associated with lower serum CC16 levels. CC16 levels were associated with average trichloramine concentrations in pools; however, not after considering swimming frequency multiplied by trichloramine levels. Conclusions Measured trichloramine levels were comparable with other studies but lower than in an earlier Dutch study. Swimming pool attendance was not associated with respiratory symptoms. The association between sensitisation and swimming during the first 2 years of life suggests that early-life exposures might be important, although this needs further study. The interpretation of transient and chronic changes of CC16 and other inflammatory markers in relation to the pool environment and health impacts warrants further investigation. Detailed comparisons with other studies are limited as few studies have measured trichloramine levels.
- 4 August 2012
- Published by BMJ in Occupational and Environmental Medicine
- Vol. 69 (11) , 823-830
Swimming pool attendance and respiratory symptoms and allergies among Dutch children
Objectives To describe associations among swimming, respiratory health, allergen sensitisation and Clara cell protein 16 (CC16) levels in Dutch schoolchildren. Trichloramine levels in swimming pool air were determined to assess potential exposure levels. Methods Respiratory health and pool attendance information was collected from 2359 children, aged 6–13 years. Serum from 419 children was tested for allergen sensitisation and CC16 levels. Trichloramine levels were assessed in nine swimming facilities. Results Trichloramine levels ranged from 0.03 to 0.78 mg/m3 (average 0.21 mg/m3). Reported swimming pool attendance and trichloramine exposure were both not associated with asthma, wheezing, rhinitis or CC16 levels. Birch and house dust mite sensitisation were associated with recent indoor swimming (OR>1.86), but not after considering recent swimming frequency multiplied by trichloramine levels. Sensitisation to house dust mites was associated with frequent baby swimming (ORs=1.75; 95% CI 1.09 to 2.79). Furthermore, sensitisation was associated with lower serum CC16 levels. CC16 levels were associated with average trichloramine concentrations in pools; however, not after considering swimming frequency multiplied by trichloramine levels. Conclusions Measured trichloramine levels were comparable with other studies but lower than in an earlier Dutch study. Swimming pool attendance was not associated with respiratory symptoms. The association between sensitisation and swimming during the first 2 years of life suggests that early-life exposures might be important, although this needs further study. The interpretation of transient and chronic changes of CC16 and other inflammatory markers in relation to the pool environment and health impacts warrants further investigation. Detailed comparisons with other studies are limited as few studies have measured trichloramine levels.