Paul Centore
Research Subjects
Research Interests
Latest Publications
- 10 November 2020
- Published by Wiley in Coloration Technology
- Vol. 136 (6) , 492-502
Enforcing Kubelka–Munk constraints for opaque paints
- 10 November 2020
- Published by Wiley in Coloration Technology
- Vol. 136 (6) , 492-502
Enforcing Kubelka–Munk constraints for opaque paints
- 18 December 2015
- Published by Wiley in Color Research & Application
- Vol. 41 (6) , 571-579
The coefficient of variation as a measure of spectrophotometric repeatability
The mean color difference from the mean (MCDM) is a standard measure of spectrophotometric repeatability. This article proposes a supplementary measure: the coefficient of variation (CoV), which is the ratio of the standard deviation of the measured reflectances to their mean. The CoV is calculated from the same repeated sample measurements as the MCDM. Unlike the MCDM, the CoV depends only on physical quantities, and not on perceptual quantities; furthermore, a CoV is defined for each wavelength. This article analyzes data from six different spectrophotometer–sample combinations. An important empirical result is that the CoV is nearly constant across wavelengths, except when the reflectance at a particular wavelength is less than about 5%, in which case, measurement variability is markedly greater. Because the MCDM tends to lose this fact through averaging, the CoV is recommended as an adjunct to the MCDM for spectrophotometer analysis and development. The CoV analysis also provides evidence that samples’ surface geometry is a major factor in measurement variability. © 2015 Wiley Periodicals, Inc. Col Res Appl, 41, 571–579, 2016
- 18 December 2015
- Published by Wiley in Color Research & Application
- Vol. 41 (6) , 571-579
The coefficient of variation as a measure of spectrophotometric repeatability
The mean color difference from the mean (MCDM) is a standard measure of spectrophotometric repeatability. This article proposes a supplementary measure: the coefficient of variation (CoV), which is the ratio of the standard deviation of the measured reflectances to their mean. The CoV is calculated from the same repeated sample measurements as the MCDM. Unlike the MCDM, the CoV depends only on physical quantities, and not on perceptual quantities; furthermore, a CoV is defined for each wavelength. This article analyzes data from six different spectrophotometer–sample combinations. An important empirical result is that the CoV is nearly constant across wavelengths, except when the reflectance at a particular wavelength is less than about 5%, in which case, measurement variability is markedly greater. Because the MCDM tends to lose this fact through averaging, the CoV is recommended as an adjunct to the MCDM for spectrophotometer analysis and development. The CoV analysis also provides evidence that samples’ surface geometry is a major factor in measurement variability. © 2015 Wiley Periodicals, Inc. Col Res Appl, 41, 571–579, 2016
- 4 August 2012
- Published by Wiley in Color Research & Application
- Vol. 39 (2) , 179-187
Geometric invariants under illuminant transformations
An object colour's Commission Internationale de l'Éclairage XYZ coordinates can change when it is viewed under different illuminants. The set of XYZ coordinates for all object colours, which is called the object‐colour solid, likewise varies under different illuminants. This article shows that, despite these changes, some properties are invariant under illuminant transformations. In particular, as long as the illuminant is nowhere zero in the visible spectrum, optimal colours take the same Schrödinger form, and no two optimal colours are metameric. Furthermore, all object‐colour solids have the same shape at the origin: they all fit perfectly into the convex cone (which we will call the spectrum cone) generated by the spectrum locus. The spectrum cone, itself, does not vary when the illuminant changes. The object‐colour solid for one illuminant can be transformed into the solid for another illuminant, by an easily visualized sequence of expansions and contractions of irregular rings, called zones. © 2012 Wiley Periodicals, Inc. Col Res Appl, 39, 179–187, 2014
- 4 August 2012
- Published by Wiley in Color Research & Application
- Vol. 39 (2) , 179-187
Geometric invariants under illuminant transformations
An object colour's Commission Internationale de l'Éclairage XYZ coordinates can change when it is viewed under different illuminants. The set of XYZ coordinates for all object colours, which is called the object‐colour solid, likewise varies under different illuminants. This article shows that, despite these changes, some properties are invariant under illuminant transformations. In particular, as long as the illuminant is nowhere zero in the visible spectrum, optimal colours take the same Schrödinger form, and no two optimal colours are metameric. Furthermore, all object‐colour solids have the same shape at the origin: they all fit perfectly into the convex cone (which we will call the spectrum cone) generated by the spectrum locus. The spectrum cone, itself, does not vary when the illuminant changes. The object‐colour solid for one illuminant can be transformed into the solid for another illuminant, by an easily visualized sequence of expansions and contractions of irregular rings, called zones. © 2012 Wiley Periodicals, Inc. Col Res Appl, 39, 179–187, 2014
- 28 September 2011
- Published by Wiley in Color Research & Application
- Vol. 38 (2) , 110-119
A zonohedral approach to optimal colours
- 28 September 2011
- Published by Wiley in Color Research & Application
- Vol. 38 (2) , 110-119
A zonohedral approach to optimal colours
- 13 September 2011
- Published by Wiley in Color Research & Application
- Vol. 37 (6) , 455-464
An open‐source inversion algorithm for the Munsell renotation
The 1943 Munsell renotation includes a table that converts 2734 Munsell specifications into xyY coordinates, along with a graphical interpolation method and a graphical inversion method, that converts xyY coordinates back into Munsell specifications. This article presents open‐source computer code, running in Matlab or Octave, that both interpolates and inverts the Munsell renotation automatically. The steps in both algorithms are described in detail. Like previous inversion algorithms, it relies on interpolations between entries in the 1943 table. For colours near the MacAdam limits, the inversion also requires extrapolations beyond the 1943 entries. The outputs of the current implementation do not differ significantly from the outputs of other inversion algorithms. The main distinguishing feature of the current algorithm is that both the algorithm and code implementation are publicly available. © 2011 Wiley Periodicals, Inc. Col Res Appl, 2011;
- 13 September 2011
- Published by Wiley in Color Research & Application
- Vol. 37 (6) , 455-464
An open‐source inversion algorithm for the Munsell renotation
The 1943 Munsell renotation includes a table that converts 2734 Munsell specifications into xyY coordinates, along with a graphical interpolation method and a graphical inversion method, that converts xyY coordinates back into Munsell specifications. This article presents open‐source computer code, running in Matlab or Octave, that both interpolates and inverts the Munsell renotation automatically. The steps in both algorithms are described in detail. Like previous inversion algorithms, it relies on interpolations between entries in the 1943 table. For colours near the MacAdam limits, the inversion also requires extrapolations beyond the 1943 entries. The outputs of the current implementation do not differ significantly from the outputs of other inversion algorithms. The main distinguishing feature of the current algorithm is that both the algorithm and code implementation are publicly available. © 2011 Wiley Periodicals, Inc. Col Res Appl, 2011;
- 16 August 2011
- Published by Wiley in Color Research & Application
- Vol. 38 (1) , 58-64
Shadow series in the Munsell system
- 16 August 2011
- Published by Wiley in Color Research & Application
- Vol. 38 (1) , 58-64
Shadow series in the Munsell system