Franjo Pernuš
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Franjo Pernuš has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Boštjan Likar
Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia
22 shared publications - Tomaž Vrtovec
Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia
12 shared publications - Žiga Špiclin
Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia
5 shared publications - Bulat Ibragimov
University of Ljubljana
4 shared publications - Robert Korez
University of Ljubljana
4 shared publications - Dejan Tomaževič
University of Ljubljana, Faculty of Electrical Engineering, Trzaska 25, 1000 Ljubljana, Slovenia
3 shared publications
Latest Publications
- Open Access
- 18 April 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (08) , 083012-20
MCDataset: a public reference dataset of Monte Carlo simulated quantities for multilayered and voxelated tissues computed by massively parallel PyXOpto Python package
Light propagation modeling in turbid media such as biological tissues is essential in many branches of biomedical optics, allowing estimation of various light-related physical properties that can be measured and further related to the composition and structure of biological tissues. Through the years, light propagation modeling has found its use in diffuse optical tomography,1 – 3 optoacoustic imaging,4,5 spatial frequency domain imaging (SFDI),6,7 hyperspectral imaging,8 tissue and sample characterization with integrating spheres,9,10 light delivery and treatment planning,11,12 and many more.
- 18 April 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (08) , 083012-20
Open AccessMCDataset: a public reference dataset of Monte Carlo simulated quantities for multilayered and voxelated tissues computed by massively parallel PyXOpto Python package
Light propagation modeling in turbid media such as biological tissues is essential in many branches of biomedical optics, allowing estimation of various light-related physical properties that can be measured and further related to the composition and structure of biological tissues. Through the years, light propagation modeling has found its use in diffuse optical tomography,1 – 3 optoacoustic imaging,4,5 spatial frequency domain imaging (SFDI),6,7 hyperspectral imaging,8 tissue and sample characterization with integrating spheres,9,10 light delivery and treatment planning,11,12 and many more.
- 2 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (2) , 396-406
Practical Priors for Bayesian Inference of Latent Biomarkers
Latent biomarkers are quantities that strongly relate to patient's disease diagnosis and prognosis, but are difficult to measure or even not directly observable. The objective of this study was to develop, analyze and validate new priors for Bayesian inference of such biomarkers. Theoretical analysis revealed a relationship between the estimates inferred from the model and the true values of measured quantities, and the impact of the priors. This led to a new prior encoding scheme that incorporates objectively measurable domain knowledge, i.e. by performing two measurements with a reference method, which imply scale of the prior distribution. Second, priors on parameters of systematic error are non-informative, which enables biomarker estimation from a set of different quantities. Analysis showed that the volume of nucleus basalis of Meynert, which is reduced in early stages of Alzheimer's dementia and Parkinson's disease, is inter-related and could be inferred from compartmental brain volume measurements performed on routine clinical MR scans. Another experiment showed that total lesion load, associated to future disability progression in multiple sclerosis patients, could be inferred from lesion volume measurements based on multiple automated MR scan segmentations. Besides, figures of merit derived from the estimates could, without comparing against reference gold standard segmentations, identify the best performing lesion segmentation method. The proposed new priors substantially simplify the application of Bayesian inference for latent biomarkers and thus open an avenue for clinical implementation of new biomarkers, which may ultimately advance the evidence-based medicine.
- 2 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (2) , 396-406
Practical Priors for Bayesian Inference of Latent Biomarkers
Latent biomarkers are quantities that strongly relate to patient's disease diagnosis and prognosis, but are difficult to measure or even not directly observable. The objective of this study was to develop, analyze and validate new priors for Bayesian inference of such biomarkers. Theoretical analysis revealed a relationship between the estimates inferred from the model and the true values of measured quantities, and the impact of the priors. This led to a new prior encoding scheme that incorporates objectively measurable domain knowledge, i.e. by performing two measurements with a reference method, which imply scale of the prior distribution. Second, priors on parameters of systematic error are non-informative, which enables biomarker estimation from a set of different quantities. Analysis showed that the volume of nucleus basalis of Meynert, which is reduced in early stages of Alzheimer's dementia and Parkinson's disease, is inter-related and could be inferred from compartmental brain volume measurements performed on routine clinical MR scans. Another experiment showed that total lesion load, associated to future disability progression in multiple sclerosis patients, could be inferred from lesion volume measurements based on multiple automated MR scan segmentations. Besides, figures of merit derived from the estimates could, without comparing against reference gold standard segmentations, identify the best performing lesion segmentation method. The proposed new priors substantially simplify the application of Bayesian inference for latent biomarkers and thus open an avenue for clinical implementation of new biomarkers, which may ultimately advance the evidence-based medicine.
- 24 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (2) , 577-587
Automated Cutting Plane Positioning for Intracranial Aneurysm Quantification
Objective: Aneurysm rupture risk can be assessed by its morphologic features extracted from angiographic images. Feature extraction entails aneurysm isolation, typically by manually positioning a cutting plane (MCP). To eliminate intra- and inter-rater variabilities we propose automatic cutting plane (ACP) positioning based on the analysis of vascular surface mesh. Methods: Innovative Hough-like and multi-hypothesis based detection of aneurysm center, parent vessel inlets and centerlines were proposed. These were used for initialization and iterative ACP positioning by geometry-inspired cost function optimization. For validation and baseline comparison we tested MCP and manual neck curve based isolation. Isolated aneurysm morphology was characterized by size, dome height, aspect ratio and nonsphericity index. Results: Methods were applied to 55 intracranial saccular aneurysms from two sites, involving 3D DSA, CTA and MRA modalities. Isolation based on ACP resulted in small average inter-curve distances (AICDs), compared to those obtained by MCP. One case had AICD higher than 1.0 mm, while 90% of cases had AICD < 0.5 mm. Intra- and inter-rater AICD variability of manual neck curves was higher compared to MCP, validating its robustness for clinical purposes. Conclusion: The ACP method achieved high accuracy and reliability of aneurysm isolation, also confirmed by expert visual analysis. So extracted morphologic features were in good agreement with MCP-based ones therefore ACP has great potential for aneurysm quantification in clinical applications. Significance: Novel method is angiographic modality agnostic, delivers repeatable isolation important in follow-up aneurysm assessment, its performance is comparable to MCP, re-evaluation is fast and simple.
- 24 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (2) , 577-587
Automated Cutting Plane Positioning for Intracranial Aneurysm Quantification
Objective: Aneurysm rupture risk can be assessed by its morphologic features extracted from angiographic images. Feature extraction entails aneurysm isolation, typically by manually positioning a cutting plane (MCP). To eliminate intra- and inter-rater variabilities we propose automatic cutting plane (ACP) positioning based on the analysis of vascular surface mesh. Methods: Innovative Hough-like and multi-hypothesis based detection of aneurysm center, parent vessel inlets and centerlines were proposed. These were used for initialization and iterative ACP positioning by geometry-inspired cost function optimization. For validation and baseline comparison we tested MCP and manual neck curve based isolation. Isolated aneurysm morphology was characterized by size, dome height, aspect ratio and nonsphericity index. Results: Methods were applied to 55 intracranial saccular aneurysms from two sites, involving 3D DSA, CTA and MRA modalities. Isolation based on ACP resulted in small average inter-curve distances (AICDs), compared to those obtained by MCP. One case had AICD higher than 1.0 mm, while 90% of cases had AICD < 0.5 mm. Intra- and inter-rater AICD variability of manual neck curves was higher compared to MCP, validating its robustness for clinical purposes. Conclusion: The ACP method achieved high accuracy and reliability of aneurysm isolation, also confirmed by expert visual analysis. So extracted morphologic features were in good agreement with MCP-based ones therefore ACP has great potential for aneurysm quantification in clinical applications. Significance: Novel method is angiographic modality agnostic, delivers repeatable isolation important in follow-up aneurysm assessment, its performance is comparable to MCP, re-evaluation is fast and simple.
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 33-41
Segmentation of parotid glands from registered CT and MR images
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 33-41
Segmentation of parotid glands from registered CT and MR images
- 1 July 2016
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 3-13
Automated Pedicle Screw Size and Trajectory Planning by Maximization of Fastening Strength
- 1 July 2016
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 3-13
Automated Pedicle Screw Size and Trajectory Planning by Maximization of Fastening Strength
- 21 March 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9784, 97842
Joint detection and segmentation of vertebral bodies in CT images by sparse representation error minimization
Automated detection and segmentation of vertebral bodies from spinal computed tomography (CT) images is usually a prerequisite step for numerous spine-related medical applications, such as diagnosis, surgical planning and follow-up assessment of spinal pathologies. However, automated detection and segmentation are challenging tasks due to a relatively high degree of anatomical complexity, presence of unclear boundaries and articulation of vertebrae with each other. In this paper, we describe a sparse representation error minimization (SEM) framework for joint detection and segmentation of vertebral bodies in CT images. By minimizing the sparse representation error of sampled intensity values, we are able to recover the oriented bounding box (OBB) and segmentation binary mask for each vertebral body in the CT image. The performance of the proposed SEM framework was evaluated on five CT images of the thoracolumbar spine. The resulting Euclidean distance of 1:75±1:02 mm, computed between the center points of recovered and corresponding reference OBBs, and Dice coefficient of 92:3±2:7%, computed between the resulting and corresponding reference segmentation binary masks, indicate that the proposed framework can successfully detect and segment vertebral bodies in CT images of the thoracolumbar spine. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 21 March 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9784, 97842
Joint detection and segmentation of vertebral bodies in CT images by sparse representation error minimization
Automated detection and segmentation of vertebral bodies from spinal computed tomography (CT) images is usually a prerequisite step for numerous spine-related medical applications, such as diagnosis, surgical planning and follow-up assessment of spinal pathologies. However, automated detection and segmentation are challenging tasks due to a relatively high degree of anatomical complexity, presence of unclear boundaries and articulation of vertebrae with each other. In this paper, we describe a sparse representation error minimization (SEM) framework for joint detection and segmentation of vertebral bodies in CT images. By minimizing the sparse representation error of sampled intensity values, we are able to recover the oriented bounding box (OBB) and segmentation binary mask for each vertebral body in the CT image. The performance of the proposed SEM framework was evaluated on five CT images of the thoracolumbar spine. The resulting Euclidean distance of 1:75±1:02 mm, computed between the center points of recovered and corresponding reference OBBs, and Dice coefficient of 92:3±2:7%, computed between the resulting and corresponding reference segmentation binary masks, indicate that the proposed framework can successfully detect and segment vertebral bodies in CT images of the thoracolumbar spine. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 20 November 2015
- Published by Springer Nature
- p. 3-10
Computer-Aided Detection and Quantification of Intracranial Aneurysms
- 20 November 2015
- Published by Springer Nature
- p. 3-10
Computer-Aided Detection and Quantification of Intracranial Aneurysms
- Open Access
- 30 June 2015
- Published by Slovenian Society for Stereology and Quantitative Image Analysis in Image Analysis and Stereology
- Vol. 34 (3) , 199
VARIABILITY OF MANUAL AND COMPUTERIZED METHODS FOR MEASURING CORONAL VERTEBRAL INCLINATION IN COMPUTED TOMOGRAPHY IMAGES
Objective measurement of coronal vertebral inclination (CVI) is of significant importance for evaluating spinal deformities in the coronal plane. The purpose of this study is to systematically analyze and compare manual and computerized measurements of CVI in cross-sectional and volumetric computed tomography (CT) images. Three observers independently measured CVI in 14 CT images of normal and 14 CT images of scoliotic vertebrae by using six manual and two computerized measurements. Manual measurements were obtained in coronal cross-sections by manually identifying the vertebral body corners, which served to measure CVI according to the superior and inferior tangents, left and right tangents, and mid-endplate and mid-wall lines. Computerized measurements were obtained in two dimensions (2D) and in three dimensions (3D) by manually initializing an automated method in vertebral centroids and then searching for the planes of maximal symmetry of vertebral anatomical structures. The mid-endplate lines were the most reproducible and reliable manual measurements (intra- and inter-observer variability of 0.7° and 1.2° standard deviation, SD, respectively). The computerized measurements in 3D were more reproducible and reliable (intra- and inter-observer variability of 0.5° and 0.7° SD, respectively), but were most consistent with the mid-wall lines (2.0° SD and 1.4° mean absolute difference). The manual CVI measurements based on mid-endplate lines and the computerized CVI measurements in 3D resulted in the lowest intra-observer and inter-observer variability, however, computerized CVI measurements reduce observer interaction.
- 30 June 2015
- Published by Slovenian Society for Stereology and Quantitative Image Analysis in Image Analysis and Stereology
- Vol. 34 (3) , 199
Open AccessVARIABILITY OF MANUAL AND COMPUTERIZED METHODS FOR MEASURING CORONAL VERTEBRAL INCLINATION IN COMPUTED TOMOGRAPHY IMAGES
Objective measurement of coronal vertebral inclination (CVI) is of significant importance for evaluating spinal deformities in the coronal plane. The purpose of this study is to systematically analyze and compare manual and computerized measurements of CVI in cross-sectional and volumetric computed tomography (CT) images. Three observers independently measured CVI in 14 CT images of normal and 14 CT images of scoliotic vertebrae by using six manual and two computerized measurements. Manual measurements were obtained in coronal cross-sections by manually identifying the vertebral body corners, which served to measure CVI according to the superior and inferior tangents, left and right tangents, and mid-endplate and mid-wall lines. Computerized measurements were obtained in two dimensions (2D) and in three dimensions (3D) by manually initializing an automated method in vertebral centroids and then searching for the planes of maximal symmetry of vertebral anatomical structures. The mid-endplate lines were the most reproducible and reliable manual measurements (intra- and inter-observer variability of 0.7° and 1.2° standard deviation, SD, respectively). The computerized measurements in 3D were more reproducible and reliable (intra- and inter-observer variability of 0.5° and 0.7° SD, respectively), but were most consistent with the mid-wall lines (2.0° SD and 1.4° mean absolute difference). The manual CVI measurements based on mid-endplate lines and the computerized CVI measurements in 3D resulted in the lowest intra-observer and inter-observer variability, however, computerized CVI measurements reduce observer interaction.
- 10 February 2015
- Published by Springer Nature
- p. 85-94
An Improved Shape-Constrained Deformable Model for Segmentation of Vertebrae from CT Lumbar Spine Images
- 10 February 2015
- Published by Springer Nature
- p. 85-94
An Improved Shape-Constrained Deformable Model for Segmentation of Vertebrae from CT Lumbar Spine Images
- 10 February 2015
- Published by Springer Nature
- p. 73-84
Interpolation-Based Detection of Lumbar Vertebrae in CT Spine Images
- 10 February 2015
- Published by Springer Nature
- p. 73-84
Interpolation-Based Detection of Lumbar Vertebrae in CT Spine Images