Hans Ulrich Käufl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hans Ulrich Käufl has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
B. Edvardsson
Department of Astronomy and Space Physics Uppsala University Sweden
2 shared publications- Bengt Gustafsson
Department of Astronomy and Space Physics, University of Uppsala, Uppsala, Sweden
2 shared publications - Stefan Uttenthaler
Institute of Applied Physics, TU Wien
2 shared publications - Alain Smette
European Southern Observatory, Casilla 19001, Santiago 19, Chile
1 shared publication - Anne-Marie Lagrange
Observatoire de Grenoble (France)
1 shared publication B. Aringer
Institute for Astronomy, University of Vienna, Türkenschanzstraße 17, 1180 Vienna, Austria [uttenthaler;hron;lebzelter;lederer;aringer]@astro.univie.ac.at
1 shared publication
Latest Publications
- 1 July 2011
- Published by Cambridge University Press (CUP) in Proceedings of the International Astronomical Union
- Vol. 7 (S283) , 287-294
The frontier of ground-based observations
The ESO VLT on Paranal is in transition from first generation instrumentation to second generation, or at least to substantially upgraded instrumentation. The new instrumentation shall establish multipicity gain, high image definition or integral field imaging spectroscopy. Starting from observational highlights, status and trends for groundbased instrumentation will be revisited with emphasis on the field of PNe in all evolutionary phases. This review will concentrate on spectroscopy and scientific cases where groundbased observations offer a particular advantage. To the extent possible, a projection will be given as to the potential of the extremely large telescopes on the horizon, which will work best in the (near-)infrared.
- 1 July 2011
- Published by Cambridge University Press (CUP) in Proceedings of the International Astronomical Union
- Vol. 7 (S283) , 287-294
The frontier of ground-based observations
The ESO VLT on Paranal is in transition from first generation instrumentation to second generation, or at least to substantially upgraded instrumentation. The new instrumentation shall establish multipicity gain, high image definition or integral field imaging spectroscopy. Starting from observational highlights, status and trends for groundbased instrumentation will be revisited with emphasis on the field of PNe in all evolutionary phases. This review will concentrate on spectroscopy and scientific cases where groundbased observations offer a particular advantage. To the extent possible, a projection will be given as to the potential of the extremely large telescopes on the horizon, which will work best in the (near-)infrared.
- 25 August 2010
- Published by Wiley
- p. 229-240
VLT‐CRIRES: “Good Vibrations”, Rotational‐Vibrational Molecular Spectroscopy in Astronomy
- 25 August 2010
- Published by Wiley
- p. 229-240
VLT‐CRIRES: “Good Vibrations”, Rotational‐Vibrational Molecular Spectroscopy in Astronomy
- Open Access
- 20 May 2010
- Published by Wiley in Astronomische Nachrichten
- Vol. 331 (5) , 549-554
VLT‐CRIRES: “Good Vibrations” Rotational‐vibrational molecular spectroscopy in astronomy
Near‐Infrared high spectral and spatial resolution spectroscopy offers new and innovative observing opportunities for astronomy. The “traditional” benefits of IR‐astronomy – strongly reduced extinction and availability of adaptive optics – more than offset for many applications the compared to CCD‐based astronomy strongly reduced sensitivity. Especially in high resolution spectroscopy interferences by telluric lines can be minimized. Moreover for abundance studies many important atomic lines can be accessed in the NIR. A novel spectral feature available for quantitative spectroscopy are the molecular rotational‐vibrational transitions which allow for fundamentally new studies of condensed objects and atmospheres. This is also an important complement to radio‐astronomy, especially with ALMA, where molecules are generally only observed in the vibrational ground state. Rot‐vib transitions also allow high precision abundance measurements – including isotopic ratios – fundamental to understand the thermo‐nuclear processes in stars beyond the main sequence. Quantitative modeling of atmospheres has progressed such that the unambiguous interpretation of IR‐spectra is now well established. In combination with adaptive optics spectro‐astrometry is even more powerful and with VLT‐CRIRES a spatial resolution of better than one milli‐arcsecond has been demonstrated. Some highlights and recent results will be presented: our solar system, extrasolar planets, star‐ and planet formation, stellar evolution and the formation of galactic bulges
- 20 May 2010
- Published by Wiley in Astronomische Nachrichten
- Vol. 331 (5) , 549-554
Open AccessVLT‐CRIRES: “Good Vibrations” Rotational‐vibrational molecular spectroscopy in astronomy
Near‐Infrared high spectral and spatial resolution spectroscopy offers new and innovative observing opportunities for astronomy. The “traditional” benefits of IR‐astronomy – strongly reduced extinction and availability of adaptive optics – more than offset for many applications the compared to CCD‐based astronomy strongly reduced sensitivity. Especially in high resolution spectroscopy interferences by telluric lines can be minimized. Moreover for abundance studies many important atomic lines can be accessed in the NIR. A novel spectral feature available for quantitative spectroscopy are the molecular rotational‐vibrational transitions which allow for fundamentally new studies of condensed objects and atmospheres. This is also an important complement to radio‐astronomy, especially with ALMA, where molecules are generally only observed in the vibrational ground state. Rot‐vib transitions also allow high precision abundance measurements – including isotopic ratios – fundamental to understand the thermo‐nuclear processes in stars beyond the main sequence. Quantitative modeling of atmospheres has progressed such that the unambiguous interpretation of IR‐spectra is now well established. In combination with adaptive optics spectro‐astrometry is even more powerful and with VLT‐CRIRES a spatial resolution of better than one milli‐arcsecond has been demonstrated. Some highlights and recent results will be presented: our solar system, extrasolar planets, star‐ and planet formation, stellar evolution and the formation of galactic bulges
- 25 July 2009
- Published by Springer Nature in Earth, Moon, and Planets
- Vol. 105 (2-4) , 61-64
Preface to Special Edition of EM&P, Reporting on the INAF/Arcetri-ESO-Workshop on “Future Ground-based Solar System Research: Synergies with Space Probes and Space Telescope” held at Portoferraio, Elba, Italy, 8–12 September 2008
- 25 July 2009
- Published by Springer Nature in Earth, Moon, and Planets
- Vol. 105 (2-4) , 61-64
Preface to Special Edition of EM&P, Reporting on the INAF/Arcetri-ESO-Workshop on “Future Ground-based Solar System Research: Synergies with Space Probes and Space Telescope” held at Portoferraio, Elba, Italy, 8–12 September 2008
- 20 July 2008
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 682 (1) , 509-514
The Fluorine Abundance in a Galactic Bulge AGB Star Measured from CRIRES Spectra
We present measurements of the fluorine abundance in a Galactic bulge asymptotic giant branch (AGB) star. The measurements were performed using high-resolution K-band spectra obtained with the CRIRES spectrograph, which has been recently installed at ESO's VLT, together with state-of-the-art model atmospheres and synthetic spectra. This represents the first fluorine abundance measurement in a Galactic bulge star, and one of few measurements of this kind in a third dredge-up oxygen-rich AGB star. The F abundance is found to be close to the solar value scaled down to the metallicity of the star, and in agreement with disk giants that are comparable to the bulge giant studied here. The measurement is of astrophysical interest also because the star's mass can be estimated rather accurately (1.4 M/M☉ 2.0). AGB nucleosynthesis models predict only a very mild enrichment of F in such low mass AGB stars. Thus, we suggest that the fluorine abundance found in the studied star is representative for the star's natal cloud, and that fluorine must have been produced at a similar level in the bulge and in the disk.
- 20 July 2008
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 682 (1) , 509-514
The Fluorine Abundance in a Galactic Bulge AGB Star Measured from CRIRES Spectra
We present measurements of the fluorine abundance in a Galactic bulge asymptotic giant branch (AGB) star. The measurements were performed using high-resolution K-band spectra obtained with the CRIRES spectrograph, which has been recently installed at ESO's VLT, together with state-of-the-art model atmospheres and synthetic spectra. This represents the first fluorine abundance measurement in a Galactic bulge star, and one of few measurements of this kind in a third dredge-up oxygen-rich AGB star. The F abundance is found to be close to the solar value scaled down to the metallicity of the star, and in agreement with disk giants that are comparable to the bulge giant studied here. The measurement is of astrophysical interest also because the star's mass can be estimated rather accurately (1.4 M/M☉ 2.0). AGB nucleosynthesis models predict only a very mild enrichment of F in such low mass AGB stars. Thus, we suggest that the fluorine abundance found in the studied star is representative for the star's natal cloud, and that fluorine must have been produced at a similar level in the bulge and in the disk.
- Open Access
- 4 December 2007
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 478 (2) , 527
Technetium and lithium in Galactic bulge AGB stars
Astronomy & Astrophysics (A&A) is an international journal which publishes papers on all aspects of astronomy and astrophysics
- 4 December 2007
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 478 (2) , 527
Open AccessTechnetium and lithium in Galactic bulge AGB stars
Astronomy & Astrophysics (A&A) is an international journal which publishes papers on all aspects of astronomy and astrophysics
- Open Access
A new Generation of Spectrometer Calibration Techniques based on Optical Frequency Combs
Typical astronomical spectrographs have a resolution ranging between a few hundred to 200.000. Deconvolution and correlation techniques are being employed with a significance down to 1/1000 th of a pixel. HeAr and ThAr lamps are usually used for calibration in low and high resolution spectroscopy, respectively. Unfortunately, the emitted lines typically cover only a small fraction of the spectrometer's spectral range. Furthermore, their exact position depends strongly on environmental conditions. A problem is the strong intensity variation between different (intensity ratios {>300). In addition, the brightness of the lamps is insufficient to illuminate a spectrograph via an integrating sphere, which in turn is important to calibrate a long-slit spectrograph, as this is the only way to assure a uniform illumination of the spectrograph pupil. Laboratory precision laser spectroscopy has experienced a major advance with the development of optical frequency combs generated by pulsed femto-second lasers. These lasers emit a broad spectrum (several hundred nanometers in the visible and near infra-red) of equally-spaced "comb" lines with almost uniform intensity (intensity ratios typically <10). Self-referencing of the laser establishes a precise ruler in frequency space that can be stabilized to the 10e-18 uncertainty level, reaching absolute frequency inaccuracies at the 10e-12 level per day when using the Global Positioning System's (GPS) time signal as the reference. The exploration of the merits of this new technology holds the promise for broad-band, highly accurate and reproducible calibration required for reliable operation of current and next generation astronomic spectrometers.
Open AccessA new Generation of Spectrometer Calibration Techniques based on Optical Frequency Combs
Typical astronomical spectrographs have a resolution ranging between a few hundred to 200.000. Deconvolution and correlation techniques are being employed with a significance down to 1/1000 th of a pixel. HeAr and ThAr lamps are usually used for calibration in low and high resolution spectroscopy, respectively. Unfortunately, the emitted lines typically cover only a small fraction of the spectrometer's spectral range. Furthermore, their exact position depends strongly on environmental conditions. A problem is the strong intensity variation between different (intensity ratios {>300). In addition, the brightness of the lamps is insufficient to illuminate a spectrograph via an integrating sphere, which in turn is important to calibrate a long-slit spectrograph, as this is the only way to assure a uniform illumination of the spectrograph pupil. Laboratory precision laser spectroscopy has experienced a major advance with the development of optical frequency combs generated by pulsed femto-second lasers. These lasers emit a broad spectrum (several hundred nanometers in the visible and near infra-red) of equally-spaced "comb" lines with almost uniform intensity (intensity ratios typically <10). Self-referencing of the laser establishes a precise ruler in frequency space that can be stabilized to the 10e-18 uncertainty level, reaching absolute frequency inaccuracies at the 10e-12 level per day when using the Global Positioning System's (GPS) time signal as the reference. The exploration of the merits of this new technology holds the promise for broad-band, highly accurate and reproducible calibration required for reliable operation of current and next generation astronomic spectrometers.
- Open Access
A First Study of Giant Stars in the Galactic Bulge based on Crires spectra
We present our on-going work on the determination of elemental abundances of giants in the Galactic Bulge by means of infrared spectroscopy. We show a preliminarily reduced spectrum and a synthetic spectrum fit of the Bulge giant Arp 4203 recorded with the near-infrared, high-resolution Crires spectrograph mounted on the VLT during its science verification run in August 2006. Abundances derived from this spectrum are discussed.
Open AccessA First Study of Giant Stars in the Galactic Bulge based on Crires spectra
We present our on-going work on the determination of elemental abundances of giants in the Galactic Bulge by means of infrared spectroscopy. We show a preliminarily reduced spectrum and a synthetic spectrum fit of the Bulge giant Arp 4203 recorded with the near-infrared, high-resolution Crires spectrograph mounted on the VLT during its science verification run in August 2006. Abundances derived from this spectrum are discussed.
- Open Access
- 1 December 2006
- Published by Cambridge University Press (CUP) in Proceedings of the International Astronomical Union
- Vol. 2 (S241) , 260-261
A First Study of Giant Stars in the Galactic Bulge based on Crires spectra
We present our on-going work on the determination of elemental abundances of giants in the Galactic Bulge by means of infrared spectroscopy. We show a preliminarily reduced spectrum and a synthetic spectrum fit of the Bulge giant Arp 4203 recorded with the near-infrared, high-resolution Crires spectrograph mounted on the VLT during its science verification run in August 2006. Abundances derived from this spectrum are discussed.
- 1 December 2006
- Published by Cambridge University Press (CUP) in Proceedings of the International Astronomical Union
- Vol. 2 (S241) , 260-261
Open AccessA First Study of Giant Stars in the Galactic Bulge based on Crires spectra
We present our on-going work on the determination of elemental abundances of giants in the Galactic Bulge by means of infrared spectroscopy. We show a preliminarily reduced spectrum and a synthetic spectrum fit of the Bulge giant Arp 4203 recorded with the near-infrared, high-resolution Crires spectrograph mounted on the VLT during its science verification run in August 2006. Abundances derived from this spectrum are discussed.
- 10 January 2006
- Published by Springer Nature
- p. 239-243
TIMMI2 and VLT-ISAAC Spectroscopy of Circumstellar Dust Disks – A Spatially Resolved 3.3 μm PAH Feature Around HD100546
- 10 January 2006
- Published by Springer Nature
- p. 239-243
TIMMI2 and VLT-ISAAC Spectroscopy of Circumstellar Dust Disks – A Spatially Resolved 3.3 μm PAH Feature Around HD100546