Shinya Echigo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shinya Echigo has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
S. Itoh
Department of Environmental Engineering, Graduate School of Engineering, Kyoto University, Nishikyo, Kyoto 615-8540, Japan
5 shared publicationsSadahiko Itoh
Department of Environmental Engineering, Graduate School of Engineering, Kyoto University, Nishikyo, Kyoto 615-8540, Japan
2 shared publicationsA. Niwa
Shimazu Corp., Nishinokyo-Kuwabara-cho, Nakagyo-ku, Kyoto 604-8511, Japan
1 shared publicationDawei Quan
Graduate School of Engineering, Kyoto University, Nishikyoku, Kyoto, 615–8540, Japan
1 shared publicationH. Lei
Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, 205 North Mathews Ave, Urbana IL, 61801, USA
1 shared publicationHideto Jinno
National Institute of Health Sciences, Setagayaku, Tokyo, 158–8501, Japan
1 shared publication
Latest Publications
- Open Access
- 25 April 2016
- Published by IWA Publishing in Journal of Water Reuse and Desalination
- Vol. 7 (2) , 142-151
Fate of selected pharmaceuticals and their metabolites in soil aquifer treatment
Through a series of long-term column experiments, the fate of three common pharmaceuticals (carbamazepine (CBZ), diclofenac, and indomethacin) and their major phase I metabolites in soil aquifer treatment (SAT) were monitored. CBZ concentration increased by a factor of two (from 37 to ca. 70 ng/L) regardless of the treatment conditions, and its metabolites, 10,11-dihydro-10-hydroxycarbamazepine (approximately 500 ng/L after SAT) and CBZ-10,11-epoxide (12–42 ng/L after SAT) were not effectively removed after SAT. Our results indicated that some metabolites of pharmaceuticals are present at much higher concentration than the original forms in the SAT effluent, and that some metabolites are more persistent during SAT with a relatively short retention time (i.e., 30 days). The study indicated that more attention should be paid to the formation and fate of metabolites in the water quality management of SAT effluent.
- 25 April 2016
- Published by IWA Publishing in Journal of Water Reuse and Desalination
- Vol. 7 (2) , 142-151
Open AccessFate of selected pharmaceuticals and their metabolites in soil aquifer treatment
Through a series of long-term column experiments, the fate of three common pharmaceuticals (carbamazepine (CBZ), diclofenac, and indomethacin) and their major phase I metabolites in soil aquifer treatment (SAT) were monitored. CBZ concentration increased by a factor of two (from 37 to ca. 70 ng/L) regardless of the treatment conditions, and its metabolites, 10,11-dihydro-10-hydroxycarbamazepine (approximately 500 ng/L after SAT) and CBZ-10,11-epoxide (12–42 ng/L after SAT) were not effectively removed after SAT. Our results indicated that some metabolites of pharmaceuticals are present at much higher concentration than the original forms in the SAT effluent, and that some metabolites are more persistent during SAT with a relatively short retention time (i.e., 30 days). The study indicated that more attention should be paid to the formation and fate of metabolites in the water quality management of SAT effluent.
- 28 August 2014
- Published by IWA Publishing in Water Supply
- Vol. 15 (1) , 101-106
Effect of preozonation on wastewater reclamation by the combination of ozonation and soil aquifer treatment
A series of column experiments and risk evaluation showed that preozonation was a better option to enhance the performance of soil aquifer treatment (SAT) than ozonation after SAT with respect to dissolved organic carbon, trace organic contaminants, and disinfection byproducts. This is a good example to show that upgrading pretreatments can be more effective than adding extra treatments after SAT, and that it is important to optimize a water reclamation system as a whole system.
- 28 August 2014
- Published by IWA Publishing in Water Supply
- Vol. 15 (1) , 101-106
Effect of preozonation on wastewater reclamation by the combination of ozonation and soil aquifer treatment
A series of column experiments and risk evaluation showed that preozonation was a better option to enhance the performance of soil aquifer treatment (SAT) than ozonation after SAT with respect to dissolved organic carbon, trace organic contaminants, and disinfection byproducts. This is a good example to show that upgrading pretreatments can be more effective than adding extra treatments after SAT, and that it is important to optimize a water reclamation system as a whole system.
- 4 November 2013
- Published by IWA Publishing in Journal of Water Supply: Research and Technology—AQUA
- Vol. 63 (2) , 106-113
Reduction of chlorinous odor by the combination of oxidation and ion-exchange treatments
To better control chlorinous odor in tap water, we assessed the performance of the combination of oxidation (ozonation or advanced oxidation processes, AOP) and ion-exchange treatment. In this process, the hydrophilic neutral fraction (a major dissolved organic matter (DOM) fraction) is converted to ionic species, and these ions and ammonium ion are effectively removed during ion-exchange processes. We found that each treatment process (e.g., oxidation alone or ion exchange alone) was effective for the reduction of chlorinous odor to some extent, but the chlorinous odor formation potential was lower when the oxidation process and ion exchange were applied in series. The combination of AOP (ozone/vacuum ultraviolet treatment) at a high ozone dose and ion exchange (both cation and anion) was most effective, and the chlorinous odor formation potential was reduced to approximately 30 TON (threshold odor number) from more than 100 TON. Also, dissolved organic carbon and ammonium ion were effectively removed with this process. Compared with ozonation, AOP was more effective at a higher ozone dose. The effectiveness of this process was also confirmed in continuous mode by pilot-scale experiment.
- 4 November 2013
- Published by IWA Publishing in Journal of Water Supply: Research and Technology—AQUA
- Vol. 63 (2) , 106-113
Reduction of chlorinous odor by the combination of oxidation and ion-exchange treatments
To better control chlorinous odor in tap water, we assessed the performance of the combination of oxidation (ozonation or advanced oxidation processes, AOP) and ion-exchange treatment. In this process, the hydrophilic neutral fraction (a major dissolved organic matter (DOM) fraction) is converted to ionic species, and these ions and ammonium ion are effectively removed during ion-exchange processes. We found that each treatment process (e.g., oxidation alone or ion exchange alone) was effective for the reduction of chlorinous odor to some extent, but the chlorinous odor formation potential was lower when the oxidation process and ion exchange were applied in series. The combination of AOP (ozone/vacuum ultraviolet treatment) at a high ozone dose and ion exchange (both cation and anion) was most effective, and the chlorinous odor formation potential was reduced to approximately 30 TON (threshold odor number) from more than 100 TON. Also, dissolved organic carbon and ammonium ion were effectively removed with this process. Compared with ozonation, AOP was more effective at a higher ozone dose. The effectiveness of this process was also confirmed in continuous mode by pilot-scale experiment.
- 1 February 2013
- Published by IWA Publishing in Water Supply
- Vol. 13 (1) , 89-95
Profiles of dissolved organic matter and haloacetic acid formation potential in drinking water treatment by a comprehensive fractionation technique
A comprehensive fractionation technique was applied to a set of water samples obtained along a real drinking water treatment plant with ozonation and granular activated carbon (GAC) treatment to obtain detailed profiles of dissolved organic matter (DOM) and to evaluate the haloacetic acid (HAA) formation potentials of these DOM fractions. The results indicated that ozonation and GAC treatment showed limited ability to remove hydrophilic fractions (23%), while removal of hydrophobic fractions was 72%. The contribution of hydrophilic fractions to HAA formation increased from 30 to 61% along the treatment train because of better removal for hydrophobic fractions both in concentration and reactivity. Similar trends were also found for trihalomethanes.
- 1 February 2013
- Published by IWA Publishing in Water Supply
- Vol. 13 (1) , 89-95
Profiles of dissolved organic matter and haloacetic acid formation potential in drinking water treatment by a comprehensive fractionation technique
A comprehensive fractionation technique was applied to a set of water samples obtained along a real drinking water treatment plant with ozonation and granular activated carbon (GAC) treatment to obtain detailed profiles of dissolved organic matter (DOM) and to evaluate the haloacetic acid (HAA) formation potentials of these DOM fractions. The results indicated that ozonation and GAC treatment showed limited ability to remove hydrophilic fractions (23%), while removal of hydrophobic fractions was 72%. The contribution of hydrophilic fractions to HAA formation increased from 30 to 61% along the treatment train because of better removal for hydrophobic fractions both in concentration and reactivity. Similar trends were also found for trihalomethanes.
- 1 March 2012
- Published by IWA Publishing in Water Supply
- Vol. 12 (2) , 187-192
Effects of ion-exchange treatment on bromate formation and oxidation efficiency during ozonation
Ion-exchange treatment is a promising technique for removing hydrophilic compounds during drinking water treatment. In this study, we applied several different ion exchangers (i.e., anion exchange resins and a hydrotalcite compound) to bromide removal to minimize bromate formation during ozonation. It was found that ion-exchange treatment affected ozone and hydroxyl radical concentration profiles as well as bromate ion concentration after ozonation. Selecting an appropriate ion exchanger is important to achieve both the oxidation of target contaminants and the reduction of bromate ion during ozonation.
- 1 March 2012
- Published by IWA Publishing in Water Supply
- Vol. 12 (2) , 187-192
Effects of ion-exchange treatment on bromate formation and oxidation efficiency during ozonation
Ion-exchange treatment is a promising technique for removing hydrophilic compounds during drinking water treatment. In this study, we applied several different ion exchangers (i.e., anion exchange resins and a hydrotalcite compound) to bromide removal to minimize bromate formation during ozonation. It was found that ion-exchange treatment affected ozone and hydroxyl radical concentration profiles as well as bromate ion concentration after ozonation. Selecting an appropriate ion exchanger is important to achieve both the oxidation of target contaminants and the reduction of bromate ion during ozonation.
- 1 October 2009
- Published by IWA Publishing in Water Supply
- Vol. 9 (4) , 431-437
Evaluation of control strategies for disinfection byproducts for small water supplies using ozone as an alternative disinfection process
Batch ozonation experiments were conducted to investigate the effects of various operating options (i.e. additions of acid, ethanol, ammonium ion, and hydrogen peroxide) on the formation of disinfection byproducts (DBPs) in six different source waters. Formation of bromate, total organic bromines, total aldehydes (the sum of 13 aldehydes) was evaluated, assuming they represent three different types of DBPs during ozonation (i.e. inorganic bromine DBPs, organobromine DBPs, and non-brominated organic DBPs, respectively). Among the tested options, acid addition was found to be the best one to control all the three types of DBPs simultaneously on an ozone exposure basis.
- 1 October 2009
- Published by IWA Publishing in Water Supply
- Vol. 9 (4) , 431-437
Evaluation of control strategies for disinfection byproducts for small water supplies using ozone as an alternative disinfection process
Batch ozonation experiments were conducted to investigate the effects of various operating options (i.e. additions of acid, ethanol, ammonium ion, and hydrogen peroxide) on the formation of disinfection byproducts (DBPs) in six different source waters. Formation of bromate, total organic bromines, total aldehydes (the sum of 13 aldehydes) was evaluated, assuming they represent three different types of DBPs during ozonation (i.e. inorganic bromine DBPs, organobromine DBPs, and non-brominated organic DBPs, respectively). Among the tested options, acid addition was found to be the best one to control all the three types of DBPs simultaneously on an ozone exposure basis.
- 1 December 2007
- Published by IWA Publishing in Water Science & Technology
- Vol. 56 (11) , 117-122
Bromide removal by hydrotalcite-like compounds in a continuous system
Bromide ion removal from a real water matrix by hydrortalcite-like compounds (HTCs) was attempted in a column reactor to control the formation of brominated disinfection by-products in drinking water treatment process. The performance of HTCs was found to be comparable to a commercially available ion exchange resin for relatively low alkalinity water. Also, it was deduced that HTCs are better than ion exchange resins for high sulfate water because of their unique ion selectivity. In addition, the ion exchange reactions by HTCs were faster than a commercially available resin. Thus, HTCs are expected to provide similar performance to organic resins without the concern about secondary contamination (i.e., elution of organic compounds from resins).
- 1 December 2007
- Published by IWA Publishing in Water Science & Technology
- Vol. 56 (11) , 117-122
Bromide removal by hydrotalcite-like compounds in a continuous system
Bromide ion removal from a real water matrix by hydrortalcite-like compounds (HTCs) was attempted in a column reactor to control the formation of brominated disinfection by-products in drinking water treatment process. The performance of HTCs was found to be comparable to a commercially available ion exchange resin for relatively low alkalinity water. Also, it was deduced that HTCs are better than ion exchange resins for high sulfate water because of their unique ion selectivity. In addition, the ion exchange reactions by HTCs were faster than a commercially available resin. Thus, HTCs are expected to provide similar performance to organic resins without the concern about secondary contamination (i.e., elution of organic compounds from resins).
- 1 September 2004
- Published by IWA Publishing in Water Science & Technology
- Vol. 50 (5) , 321-328
Contribution of brominated organic disinfection by-products to the mutagenicity of drinking water
The activity inducing chromosomal aberrations of the mixture of brominated disinfection by-products (DBPs) was approximately three times higher than that of the chlorinated counterparts for the same hypohalous acid dose. With the combination of chromosomal aberration test and a new analytical technique to differentiate total organic chlorine (TOCl) and total organic bromine (TOBr), it was found that TOBr was correlated to the mutagenicity of chlorinated waters. It was also implied that for a bromide-to-TOC ratio of 0.1 (mg/mg C), brominated DBPs could account for at least 29% of the total toxicity of DBPs formed during chlorination. On the other hand, bromate ion, a major ozonation DBP, was not a major contributor to the activity inducing chromosomal aberrations of the water treated with an ozone/chlorine sequential process. Therefore, ozonation is one possible option to reduce the health risk caused by DBPs even in the presence of bromide.
- 1 September 2004
- Published by IWA Publishing in Water Science & Technology
- Vol. 50 (5) , 321-328
Contribution of brominated organic disinfection by-products to the mutagenicity of drinking water
The activity inducing chromosomal aberrations of the mixture of brominated disinfection by-products (DBPs) was approximately three times higher than that of the chlorinated counterparts for the same hypohalous acid dose. With the combination of chromosomal aberration test and a new analytical technique to differentiate total organic chlorine (TOCl) and total organic bromine (TOBr), it was found that TOBr was correlated to the mutagenicity of chlorinated waters. It was also implied that for a bromide-to-TOC ratio of 0.1 (mg/mg C), brominated DBPs could account for at least 29% of the total toxicity of DBPs formed during chlorination. On the other hand, bromate ion, a major ozonation DBP, was not a major contributor to the activity inducing chromosomal aberrations of the water treated with an ozone/chlorine sequential process. Therefore, ozonation is one possible option to reduce the health risk caused by DBPs even in the presence of bromide.