Tiziano Binzoni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tiziano Binzoni has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Fabrizio Martelli
Dipartimento di Fisica e Astronomia dell’Università degli Studi di Firenze, Sesto Fiorentino, Firenze, Italy
10 shared publications- Dimitri Van De Ville
Neuro-X Institute, École Polytechnique Fédérale de Lausanne (EPFL), Geneva, Switzerland
7 shared publications Alain Mazzolo
Service d' Études des R éacteurs et de Math ématiques Appliqu ées Universit é Paris-Saclay CEA 91191 Gif-sur-Yvette France
3 shared publicationsBruno Sanguinetti
Group of Applied Physics, University of Geneva, Switzerland
3 shared publicationsAlwin Kienle
Institut für Lasertechnologien in der Medizin und Meßtechnik, Helmholtzstrasse 12, D-89081 Ulm, Germany
2 shared publicationsAndré Liemert
Institut für Lasertechnologien in der Medizin und Meßtechnik, Helmholtzstrasse 12, D-89081 Ulm, Germany
2 shared publications
Latest Publications
- Open Access
- 7 November 2024
- Published by American Physical Society (APS) in Physical Review E
- Vol. 110 (5) , 054106
Probability density functions for photon propagation in a binary (isotropic-Poisson) statistical mixture with unmatched positive and negative refractive indexes
The exact homogenized probability density function, for a photon making a step of length s has been analytically derived for a binary (isotropic-Poisson) statistical mixture with unmatched refractive indexes. The companions, exact, homogenized probability density functions for a photon to change direction (“scatter”), with polar ϑ and azimuthal φ angles, and the homogenized albedo, have also been obtained analytically. These functions also apply to negative refractive indexes and can reduce the number of Monte Carlo simulations needed for photon propagation in complex binary (isotropic-Poisson) statistical mixtures from hundreds to just one, for an equivalent homogeneous medium. Note, that this is not an approximate approach, but a mathematically equivalent and exact result. Additionally, some tutorial examples of homogenized Monte Carlo simulations are also given. Published by the American Physical Society 2024
- 7 November 2024
- Published by American Physical Society (APS) in Physical Review E
- Vol. 110 (5) , 054106
Open AccessProbability density functions for photon propagation in a binary (isotropic-Poisson) statistical mixture with unmatched positive and negative refractive indexes
The exact homogenized probability density function, for a photon making a step of length s has been analytically derived for a binary (isotropic-Poisson) statistical mixture with unmatched refractive indexes. The companions, exact, homogenized probability density functions for a photon to change direction (“scatter”), with polar ϑ and azimuthal φ angles, and the homogenized albedo, have also been obtained analytically. These functions also apply to negative refractive indexes and can reduce the number of Monte Carlo simulations needed for photon propagation in complex binary (isotropic-Poisson) statistical mixtures from hundreds to just one, for an equivalent homogeneous medium. Note, that this is not an approximate approach, but a mathematically equivalent and exact result. Additionally, some tutorial examples of homogenized Monte Carlo simulations are also given. Published by the American Physical Society 2024
- Open Access
Probability density functions for photon propagation in a binary (isotropic-Poisson) statistical mixture with unmatched positives/negatives refractive indexes
The exact homogenized probability density function, for a photon making a step of length $s$ has been analytically derived for a binary (isotropic-Poisson) statistical mixture with unmatched refractive indexes. The companions, exact, homogenized probability density function for a photon to change direction (``scatter'') with an angle $\vartheta$, and the homogenized albedo, have also been obtained analytically. These functions also hold even in the case of negative refractive indexes and allow one to reduce hundreds of MC simulations of photon propagation in complex binary (isotropic-Poisson) statistical mixtures, to only one MC simulation, for an equivalent homogeneous medium. Note, that this is not an approximate approach, but a mathematically equivalent and exact result. Additionally, some tutorial examples of homogenized MC simulations are also given.Open AccessProbability density functions for photon propagation in a binary (isotropic-Poisson) statistical mixture with unmatched positives/negatives refractive indexes
The exact homogenized probability density function, for a photon making a step of length $s$ has been analytically derived for a binary (isotropic-Poisson) statistical mixture with unmatched refractive indexes. The companions, exact, homogenized probability density function for a photon to change direction (``scatter'') with an angle $\vartheta$, and the homogenized albedo, have also been obtained analytically. These functions also hold even in the case of negative refractive indexes and allow one to reduce hundreds of MC simulations of photon propagation in complex binary (isotropic-Poisson) statistical mixtures, to only one MC simulation, for an equivalent homogeneous medium. Note, that this is not an approximate approach, but a mathematically equivalent and exact result. Additionally, some tutorial examples of homogenized MC simulations are also given. - Open Access
- 19 June 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-12
Probability density function for random photon steps in a binary (isotropic-Poisson) statistical mixture
Monte Carlo (MC) simulations allowing to describe photons propagation in statistical mixtures represent an interest that goes way beyond the domain of optics, and can cover, e.g., nuclear reactor physics, image analysis or life science just to name a few. MC simulations are considered a “gold standard” because they give exact solutions (in the statistical sense), however, in the case of statistical mixtures their implementation is often extremely complex. For this reason, the aim of the present contribution is to propose a new approach that should allow us in the future to simplify the MC approach. This is done through an explanatory example, i.e.; by deriving the ‘exact’ analytical expression for the probability density function of photons’ random steps (single step function, SSF) propagating in a medium represented as a binary (isotropic-Poisson) statistical mixture. The use of the SSF reduces the problem to an ‘equivalent’ homogeneous medium behaving exactly as the original binary statistical mixture. This will reduce hundreds MC simulations, allowing to obtain one set of wanted parameters, to only one equivalent simple MC simulation. To the best of our knowledge the analytically ‘exact’ SSF for a binary (isotropic-Poisson) statistical mixture has never been derived before.
- 19 June 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-12
Open AccessProbability density function for random photon steps in a binary (isotropic-Poisson) statistical mixture
Monte Carlo (MC) simulations allowing to describe photons propagation in statistical mixtures represent an interest that goes way beyond the domain of optics, and can cover, e.g., nuclear reactor physics, image analysis or life science just to name a few. MC simulations are considered a “gold standard” because they give exact solutions (in the statistical sense), however, in the case of statistical mixtures their implementation is often extremely complex. For this reason, the aim of the present contribution is to propose a new approach that should allow us in the future to simplify the MC approach. This is done through an explanatory example, i.e.; by deriving the ‘exact’ analytical expression for the probability density function of photons’ random steps (single step function, SSF) propagating in a medium represented as a binary (isotropic-Poisson) statistical mixture. The use of the SSF reduces the problem to an ‘equivalent’ homogeneous medium behaving exactly as the original binary statistical mixture. This will reduce hundreds MC simulations, allowing to obtain one set of wanted parameters, to only one equivalent simple MC simulation. To the best of our knowledge the analytically ‘exact’ SSF for a binary (isotropic-Poisson) statistical mixture has never been derived before.
- Open Access
Probability density function for random photon steps in a binary (isotropic-Poisson) statistical mixture
Monte Carlo (MC) simulations allowing to describe photons propagation in statistical mixtures represent an interest that goes way beyond the domain of optics, and can cover, e.g., nuclear reactor physics, image analysis or life science just to name a few. MC simulations are considered a ``gold standard'' because they give exact solutions (in the statistical sense), however, in the case of statistical mixtures they are enormously time consuming and their implementation is often extremely complex. For this reason, the aim of the present contribution is to propose a new approach that should allow us in the future to simplify the MC approach. This is done through an explanatory example, i.e.; by deriving the `exact' analytical expression for the probability density function of photons' random steps (single step function, SSF) propagating in a medium represented as a binary (isotropic-Poisson) statistical mixture. The use of the SSF reduces the problem to an `equivalent' homogeneous medium behaving exactly as the original binary statistical mixture. This will reduce hundreds time-consuming MC simulations to only one equivalent simple MC simulation. To the best of our knowledge the analytically `exact' SSF for a binary (isotropic-Poisson) statistical mixture has never been derived before.
Open AccessProbability density function for random photon steps in a binary (isotropic-Poisson) statistical mixture
Monte Carlo (MC) simulations allowing to describe photons propagation in statistical mixtures represent an interest that goes way beyond the domain of optics, and can cover, e.g., nuclear reactor physics, image analysis or life science just to name a few. MC simulations are considered a ``gold standard'' because they give exact solutions (in the statistical sense), however, in the case of statistical mixtures they are enormously time consuming and their implementation is often extremely complex. For this reason, the aim of the present contribution is to propose a new approach that should allow us in the future to simplify the MC approach. This is done through an explanatory example, i.e.; by deriving the `exact' analytical expression for the probability density function of photons' random steps (single step function, SSF) propagating in a medium represented as a binary (isotropic-Poisson) statistical mixture. The use of the SSF reduces the problem to an `equivalent' homogeneous medium behaving exactly as the original binary statistical mixture. This will reduce hundreds time-consuming MC simulations to only one equivalent simple MC simulation. To the best of our knowledge the analytically `exact' SSF for a binary (isotropic-Poisson) statistical mixture has never been derived before.
- Open Access
- 20 April 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (08) , 083018-25
Two-step verification method for Monte Carlo codes in biomedical optics applications
Significance: Code verification is an unavoidable step prior to using a Monte Carlo (MC) code. Indeed, in biomedical optics, a widespread verification procedure for MC codes is still missing. Analytical benchmarks that can be easily used for the verification of different MC routines offer an important resource. Aim: We aim to provide a two-step verification procedure for MC codes enabling the two main tasks of an MC simulator: (1) the generation of photons’ trajectories and (2) the intersections of trajectories with boundaries separating the regions with different optical properties. The proposed method is purely based on elementary analytical benchmarks, therefore, the correctness of an MC code can be assessed with a one-sample t-test. Approach: The two-step verification is based on the following two analytical benchmarks: (1) the exact analytical formulas for the statistical moments of the spatial coordinates where the scattering events occur in an infinite medium and (2) the exact invariant solutions of the radiative transfer equation for radiance, fluence rate, and mean path length in media subjected to a Lambertian illumination. Results: We carried out a wide set of comparisons between MC results and the two analytical benchmarks for a wide range of optical properties (from non-scattering to highly scattering media, with different types of scattering functions) in an infinite non-absorbing medium (step 1) and in a non-absorbing slab (step 2). The deviations between MC results and exact analytical values are usually within two standard errors (i.e., t-tests not rejected at a 5% level of significance). The comparisons show that the accuracy of the verification increases with the number of simulated trajectories so that, in principle, an arbitrary accuracy can be obtained. Conclusions: Given the simplicity of the verification method proposed, we envision that it can be widely used in the field of biomedical optics.
- 20 April 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (08) , 083018-25
Open AccessTwo-step verification method for Monte Carlo codes in biomedical optics applications
Significance: Code verification is an unavoidable step prior to using a Monte Carlo (MC) code. Indeed, in biomedical optics, a widespread verification procedure for MC codes is still missing. Analytical benchmarks that can be easily used for the verification of different MC routines offer an important resource. Aim: We aim to provide a two-step verification procedure for MC codes enabling the two main tasks of an MC simulator: (1) the generation of photons’ trajectories and (2) the intersections of trajectories with boundaries separating the regions with different optical properties. The proposed method is purely based on elementary analytical benchmarks, therefore, the correctness of an MC code can be assessed with a one-sample t-test. Approach: The two-step verification is based on the following two analytical benchmarks: (1) the exact analytical formulas for the statistical moments of the spatial coordinates where the scattering events occur in an infinite medium and (2) the exact invariant solutions of the radiative transfer equation for radiance, fluence rate, and mean path length in media subjected to a Lambertian illumination. Results: We carried out a wide set of comparisons between MC results and the two analytical benchmarks for a wide range of optical properties (from non-scattering to highly scattering media, with different types of scattering functions) in an infinite non-absorbing medium (step 1) and in a non-absorbing slab (step 2). The deviations between MC results and exact analytical values are usually within two standard errors (i.e., t-tests not rejected at a 5% level of significance). The comparisons show that the accuracy of the verification increases with the number of simulated trajectories so that, in principle, an arbitrary accuracy can be obtained. Conclusions: Given the simplicity of the verification method proposed, we envision that it can be widely used in the field of biomedical optics.
- Open Access
Monte Carlo simulations in anomalous radiative transfer: a tutorial
Anomalous radiative transfer (ART) theory is a generalization of classical radiative transfer theory. The present tutorial wants to show how Monte Carlo (MC) codes describing photons transport in anomalous media can be implemented. It is shown that the heart of the method consists in suitably describing, in a "non-classical" manner, photons steps starting from fixed light sources or from boundaries separating regions of the medium with different optical properties. To give a better intuition of the importance of these particular photon step lengths, it is also shown numerically that the described approach is essential to preserve the invariance property for light propagation. An interesting byproduct of the MC method for ART, is that it allow us to simplify the structure of "classical" MC codes, utilized e.g. in biomedical optics.
Open AccessMonte Carlo simulations in anomalous radiative transfer: a tutorial
Anomalous radiative transfer (ART) theory is a generalization of classical radiative transfer theory. The present tutorial wants to show how Monte Carlo (MC) codes describing photons transport in anomalous media can be implemented. It is shown that the heart of the method consists in suitably describing, in a "non-classical" manner, photons steps starting from fixed light sources or from boundaries separating regions of the medium with different optical properties. To give a better intuition of the importance of these particular photon step lengths, it is also shown numerically that the described approach is essential to preserve the invariance property for light propagation. An interesting byproduct of the MC method for ART, is that it allow us to simplify the structure of "classical" MC codes, utilized e.g. in biomedical optics.
- 29 October 2019
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 36 (11) , 1883-1891
Topological complexity of photons’ paths in biological tissues
In the present contribution, three means of measuring the geometrical and topological complexity of photons’ paths in random media are proposed. This is realized by investigating the behavior of the average crossing number, the mean writhe, and the minimal crossing number of photons’ paths generated by Monte Carlo (MC) simulations, for different sets of optical parameters. It is observed that the complexity of the photons’ paths increases for increasing light source/detector spacing, and that highly “knotted” paths are formed. Due to the particular rules utilized to generate the MC photons’ paths, the present results may have an interest not only for the biomedical optics community, but also from a pure mathematical point of view.
- 29 October 2019
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 36 (11) , 1883-1891
Topological complexity of photons’ paths in biological tissues
In the present contribution, three means of measuring the geometrical and topological complexity of photons’ paths in random media are proposed. This is realized by investigating the behavior of the average crossing number, the mean writhe, and the minimal crossing number of photons’ paths generated by Monte Carlo (MC) simulations, for different sets of optical parameters. It is observed that the complexity of the photons’ paths increases for increasing light source/detector spacing, and that highly “knotted” paths are formed. Due to the particular rules utilized to generate the MC photons’ paths, the present results may have an interest not only for the biomedical optics community, but also from a pure mathematical point of view.
- Open Access
Topological complexity of photons' paths in biological tissues
In the present contribution three means of measuring the geometrical and topological complexity of photons' paths in random media are proposed. This is realized by investigating the behavior of the average crossing number, the mean writhe, and the minimal crossing number of photons' paths generated by Monte Carlo (MC) simulations, for different sets of optical parameters. It is observed that the complexity of the photons' paths increases for increasing light source/detector spacing, and that highly "knotted" paths are formed. Due to the particular rules utilized to generate the MC photons' paths, the present results may have an interest not only for the biomedical optics community, but also from a pure mathematical point of view.
Open AccessTopological complexity of photons' paths in biological tissues
In the present contribution three means of measuring the geometrical and topological complexity of photons' paths in random media are proposed. This is realized by investigating the behavior of the average crossing number, the mean writhe, and the minimal crossing number of photons' paths generated by Monte Carlo (MC) simulations, for different sets of optical parameters. It is observed that the complexity of the photons' paths increases for increasing light source/detector spacing, and that highly "knotted" paths are formed. Due to the particular rules utilized to generate the MC photons' paths, the present results may have an interest not only for the biomedical optics community, but also from a pure mathematical point of view.
- 7 May 2018
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 35 (6) , 895-902
Generalized time-independent correlation transport equation with static background: influence of anomalous transport on the field autocorrelation function
A generalized time-independent correlation transport equation (GCTE) is proposed for the field autocorrelation function. The GCTE generalizes various models for anomalous transport of photons and takes into account the possible presence of a static background. In a tutorial example, the GCTE is solved for a homogeneous semi-infinite medium in reflectance configuration through Monte Carlo simulations. The chosen anomalous photon transport model also includes the classic and the “generalized” Lambert–Beer’s law (depending on the choice of parameters). A numerical algorithm allowing generation of the related anomalous random photon steps is also given. The clear influence of anomalous transport on the field autocorrelation function is shown and discussed for the proposed specific examples by comparing the general results with the classical case (Lambert–Beer’s law).
- 7 May 2018
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 35 (6) , 895-902
Generalized time-independent correlation transport equation with static background: influence of anomalous transport on the field autocorrelation function
A generalized time-independent correlation transport equation (GCTE) is proposed for the field autocorrelation function. The GCTE generalizes various models for anomalous transport of photons and takes into account the possible presence of a static background. In a tutorial example, the GCTE is solved for a homogeneous semi-infinite medium in reflectance configuration through Monte Carlo simulations. The chosen anomalous photon transport model also includes the classic and the “generalized” Lambert–Beer’s law (depending on the choice of parameters). A numerical algorithm allowing generation of the related anomalous random photon steps is also given. The clear influence of anomalous transport on the field autocorrelation function is shown and discussed for the proposed specific examples by comparing the general results with the classical case (Lambert–Beer’s law).
- 3 November 2017
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 34 (12) , 2096-2101
Study on the mathematical relationship existing between single-photon laser-Doppler flowmetry and diffuse correlation spectroscopy with static background
In the present contribution, the theoretical relationship existing between the blood flow index measured by diffuse correlation spectroscopy and single-photon laser-Doppler flowmetry (SP-LDF) is investigated. A specific mathematical description that accounts for the properties of single-photon detectors for SP-LDP was developed. Static background has also been considered and, to the best of our knowledge, this has never been included before in SP-LDF analytical theories. The comparisons were realized for two SP-LDF implementations: for “classical” and “fast” algorithms. “Classical” SP-LDF is not sensitive to small changes on the number of detected speckles and coherence length of the laser, usually described by a unique parameter “beta.” This is a strong point when assessing blood flow index, e.g., in humans, where “beta” is particularly difficult to be determined in real time. The proposed theory may be utilized, e.g., to investigate other SP-LDF setups and optical/physiological parameter ranges or, generally, to optimize real SP-LDF instrumentation.
- 3 November 2017
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 34 (12) , 2096-2101
Study on the mathematical relationship existing between single-photon laser-Doppler flowmetry and diffuse correlation spectroscopy with static background
In the present contribution, the theoretical relationship existing between the blood flow index measured by diffuse correlation spectroscopy and single-photon laser-Doppler flowmetry (SP-LDF) is investigated. A specific mathematical description that accounts for the properties of single-photon detectors for SP-LDP was developed. Static background has also been considered and, to the best of our knowledge, this has never been included before in SP-LDF analytical theories. The comparisons were realized for two SP-LDF implementations: for “classical” and “fast” algorithms. “Classical” SP-LDF is not sensitive to small changes on the number of detected speckles and coherence length of the laser, usually described by a unique parameter “beta.” This is a strong point when assessing blood flow index, e.g., in humans, where “beta” is particularly difficult to be determined in real time. The proposed theory may be utilized, e.g., to investigate other SP-LDF setups and optical/physiological parameter ranges or, generally, to optimize real SP-LDF instrumentation.