GLGladius Lewis

Gladius Lewis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gladius Lewis has a total of 95 co-authors. Here are the top co-authors by number of shared publications:

  • Si Janna

    Department of Mechanical Engineering, The University of Memphis, Memphis, Tennessee 38152‐3180

    8 shared publications
  • Jie Xu

    Department of Mechanical Engineering, The University of Memphis, Memphis, TN 38152, USA

    4 shared publications
  • Anuradha Bhattaram

    Department of Mechanical Engineering, The University of Memphis, Memphis, Tennessee 38152, USA

    3 shared publications
  • Michael Carroll

    3 shared publications
  • Catherine Daly

    Medical Polymers Research Institute, The Queen's University of Belfast, Belfast, Northern Ireland

    2 shared publications
  • Jeffry S. Nyman

    Vanderbilt Center for Bone Biology and Department of Orthopaedics and Rehabilitation, Vanderbilt University, Nashville, Tennessee 37232

    2 shared publications

Latest Publications

  • Open Access

    Antibiotic-free antimicrobial poly (methyl methacrylate) bone cements: A state-of-the-art review

    by Gladius Lewis

    Prosthetic joint infection (PJI) is the most serious complication following total joint arthroplasty, this being because it is associated with, among other things, high morbidity and low quality of life, is difficult to prevent, and is very challenging to treat/manage. The many shortcomings of antibiotic-loaded poly (methyl methacrylate) (PMMA) bone cement (ALBC) as an agent for preventing and treating/ managing PJI are well-known. One is that microorganisms responsible for most PJI cases, such as methicillin-resistant S. aureus, have developed or are developing resistance to gentamicin sulfate, which is the antibiotic in the vast majority of approved ALBC brands. This has led to many research efforts to develop cements that do not contain gentamicin (or, for that matter, any antibiotic) but demonstrate excellent antimicrobial efficacy. There is a sizeable body of literature on these so-called “antibiotic-free antimicrobial” PMMA bone cements (AFAMBCs). The present work is a comprehensive and critical review of this body. In addition to summaries of key trends in results of characterization studies of AFAMBCs, the attractive features and shortcomings of the literature are highlighted. Short comings provide motivation for future work, with some ideas being formulation of a new generation of AFAMBCs by, example, adding a nanostructured material and/or an extract from a natural product to the powder and/or liquid of the basis cement, respectively.


  • Comparison of Methodologies for Selection of Bone Cements for Orthopaedic Surgical Procedures

    by Gladius Lewis

    Background: Poly (methyl methacrylate) (PMMA) bone cement is widely used in ortho-paedic procedures of vertebroplasty (VP) balloon kyphoplasty (BKP) and cemented total joint arthro-plasty (TJA). While only very few PMMA bone cement brands are approved (by the appropriate regulatory authority) for VP and BKP, many are approved for cemented TJA. Selection of cement for these applications must be done considering a very large number of clinically relevant properties, such as injectability, setting time, maximum polymerization temperature, polymerization rate, com-pressive strength, fracture toughness, fatigue life, and cytocompatibility. In the literature, there is a shortage of studies on methodologies for the selection of PMMA bone cement. Purpose: The present work addresses the aforementioned shortcoming of the literature. Methods: Three material selection methodologies (Desirability, Utility, and Weighted Property Index Methods) were applied to two study sets. Study Set 1 comprised three experimental types of bone cement for VP or BKP and five in vitro values of clinically-relevant cement properties and Set 2 comprised six approved antibiotic-loaded bone cement (ALBC) brands for cemented TJA and in vitro values of four clinically-relevant cement properties. Results: For each of the study sets, slight differences in the ranks of the materials were found de-pending on the selection methodology used, but when all the selection methodologies were consid-ered, there was clear differentiation in ranks. The relative attractions and challenges of the three se-lection methodologies used are highlighted. Conclusion: Decision makers in orthopaedic hospitals and clinics as well as orthopaedic surgeons, should find the results of the present study useful.

  • Influence of assigned material combination in a simulated total cervical disc replacement design on kinematics of a model of the full cervical spine: A finite element analysis study

    by Yuxin Qi, Gladius Lewis

    Background: Although cervical total disc replacement (TDR) is becoming popular, there are no finite analysis (FEA) studies involving a model of the full spine cervical (C1–C7) and determination of the influence of materials assigned to different parts of a specified TDR design on biomechanics of the model when TDR implantation is simulated. Objective: To determine the influence of assigned material combination, for a given cervical TDR design, on the kinematics of a model of the full cervical spine. Methods: A three-dimensional solid model of the full cervical spine was constructed, a finite element mesh was obtained (INT Model), after which FEA was used to determine range of motion (ROM) at each of the intersegmental positions under three clinically-relevant loadings. INT model was then modified by simulated implantation of a notional endplates-and-mobile insert TDR design, at C5–C6 (TDR Model), and six clinically-relevant applied loadings were applied. Four variants of TDR Model were used, the difference between them being in the materials assigned to the endplates and the mobile insert. Under each of the loadings, principal motions at each of the intersegmental positions were determined and compared to counterpart motions when INT Model was used. Results: Comparison of ROM results of INT Model with relevant experimental results reported in the literature showed that the model was validated. With TDR Model, the smallest overall mean of the absolute values of the % change in principal intersegmental motions (relative to corresponding results in INT Model) was when the material assigned to both the endplates and the mobile insert was poly(ether-ether-ketone). Conclusion: In a simulated implantation of a notional endplates-and-mobile-insert TDR design in a model of the full cervical spine, material combination assigned to the parts of the design exerts a marked influence on the kinematics of the model.


  • Properties of nanofiller-loaded poly (methyl methacrylate) bone cement composites for orthopedic applications: a review

    by Gladius Lewis

    There is a large body of literature on new generations of poly (methyl methacrylate) bone cements that address one or more of the material's shortcomings. Among these are cements in which one of the constituents is a nanofiller, such as nano-sized barium sulfate, multiwalled carbon nanotubes, natural nanoclay, mesoporous silica nanoparticles, or oleic acid-capped silver nanoparticles. This article is a review of the literature on the properties of these nanofiller-loaded bone cements (NFLBCs). Some key characteristics of the literature are that (1) in a number of studies, clinically relevant properties were determined, examples being maximum exotherm, setting time, fatigue life, and compressive modulus; (2) in some studies, properties were not determined in accordance with approved bone cement testing specifications, an example being fatigue life; and (3) there are a number of clinically relevant properties that were not determined in any of the studies, examples being fatigue crack propagation rate and dynamic compression creep life. These observations, as well as other considerations, suggest 12 areas for future study, such as determination of dynamic creep compliance (using nanoindentation), determination of compressive fatigue life for cements to be used in vertebral compression fracture augmentation, elucidation of toughening mechanism(s) in each type of NFLBC, and conducting well-designed clinical trials. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2016.


  • 3,3,3-Trifluoropropyltrimethoxysilane (TFPTMS) sol-gel-coated aluminum specimens: influence of sol-gel preparation medium on coating properties

    by Ying-Sing Li, Gladius Lewis, N. E. Vecchio, Johnny Yang

    Coating a component/structure is, arguably, the most common corrosion protection method, with organic barrier coatings being the most widely used variant. Many concerns have been raised about these coatings; for example, they are not biodegradable and emit volatile organic compounds. Thus, there is interest in a new generation of organic barrier coatings. This type of coating is the subject of the present study, which involved 1) application of coatings prepared from 3,3,3-trifluoropropyltrimethoxysilane (TFPTMS) sol-gel, using both an organic solvent (ethanol solution) and an aqueous solution, to Al specimens; and 2) characterization of the coatings. The influence of sol-gel preparation medium (ethanol solution versus aqueous solution) and post-coating treatment method (drying versus curing) on an assortment of coating properties, such as corrosion resistance in NaCl solution and contact angle in water, was determined. The most corrosion-resistant coating was obtained using an aqueous TFPTMS sol-gel and curing of the coated specimen at 105°C for 24 h.


  • Not all approved antibiotic-loaded PMMA bone cement brands are the same: ranking using the utility materials selection concept

    by Gladius Lewis

    In the literature on in vitro characterization of approved antibiotic-loaded poly(methyl methacrylate) bone cement brands, there is no information on the basis for selection of a given brand for use in cemented arthroplasties. This shortcoming is addressed in the present study. It involved determining four key properties (fatigue limit, fracture toughness, polymerization rate, and phosphate buffered saline diffusion coefficient) for six brands and then using the mean property values, in conjunction with a materials selection methodology, called the utility concept, to rank the brands. It is emphasized that the present work is an illustration of a rational approach to selection of a cement brand and, as such, the study findings are not intended to be recommendations regarding clinical use or otherwise of a brand.


  • Open Access

    Healthcare Engineering Defined: A White Paper

    by Ming-Chien Chyu, Tony Austin, Fethi Calisir, Samuel Chanjaplammootil, Mark J. Davis, Jesus Favela, Heng Gan, Amit Gefen, Ram Haddas, Shoshana Hahn-Goldberg, et al.

    Engineering has been playing an important role in serving and advancing healthcare. The term “Healthcare Engineering” has been used by professional societies, universities, scientific authors, and the healthcare industry for decades. However, the definition of “Healthcare Engineering” remains ambiguous. The purpose of this position paper is to present a definition of Healthcare Engineering as an academic discipline, an area of research, a field of specialty, and a profession. Healthcare Engineering is defined in terms of what it is, who performs it, where it is performed, and how it is performed, including its purpose, scope, topics, synergy, education/training, contributions, and prospects.


  • A Daptomycin-Xylitol-loaded Polymethylmethacrylate Bone Cement: How Much Xylitol Should Be Used?

    by Ali Salehi, Ashley Cox Parker, Gladius Lewis, Harry S. Courtney, Warren O. Haggard

    The rate of release of an antibiotic from an antibiotic-loaded polymethylmethacrylate (PMMA) bone cement is low. This may be increased by adding a particulate poragen (eg, xylitol) to the cement powder. However, the appropriate poragen amount is unclear. We explored the appropriate amount of xylitol to use in a PMMA bone cement loaded with daptomycin and xylitol. We prepared four groups of cement, each comprising the same amount of daptomycin in the powder (1.36 g/40 g dry powder) but different amounts of xylitol (0, 0.7, 1.4, and 2.7 g); the xylitol mass ratio (X) (mass divided by mass of the final dry cement-daptomycin-xylitol mixture) ranged from 0 to 6.13 wt/wt%. Eight mechanical, antibiotic release, and bacterial inhibitory properties were determined using three to 22 specimens or replicates per test. We then used an optimization method to determine an appropriate value of X by (1) identifying the best-fit relationship between the value of each property and X, (2) defining a master objective function incorporating all of the best fits; and (3) determining the value of X at the maximum master objective function. We found an appropriate xylitol amount to be 4.46 wt/wt% (equivalent to 1.93 g xylitol mixed with 1.36 g daptomycin and 40 g dry cement powder). We demonstrated a method that may be used to determine an appropriate xylitol amount for a daptomycin-xylitol-loaded PMMA bone cement. These findings will require in vivo confirmation. While we identified an appropriate amount of xylitol in a daptomycin-xylitol-loaded PMMA bone cement as a prophylactic agent in total joint arthroplasties, clinical evaluations are needed to confirm the effectiveness of this cement.