Judith M. Joyce
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Judith M. Joyce has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Berna Degirmenci
2 shared publicationsAmer Shammas
Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
1 shared publicationAndrew Swihart
Division of Nuclear Medicine, Department of Radiology, University of Pittsburgh Medical Center, 200 Lothrop Street, Pittsburgh, PA 15213, USA
1 shared publicationBadreddine B Bencherif
1 shared publicationBadreddine Bencherif
1 shared publicationBarry M McCook
1 shared publication
Latest Publications
- Open Access
- 15 December 2012
- Published by Galenos Yayinevi in Molecular Imaging and Radionuclide Therapy
- Vol. 21 (3) , 117-120
Rare case of Primary Pulmonary Extranodal Non-Hodgkin’s Lymphoma in a Patient with Sjogrens Syndrome: Role of FDG-PET/CT in the Initial Staging and Evaluating Response to Treatment
A 64-year old woman with a long standing Sjogren's syndrome was undergoing evaluation for renal transplant surgery when two pulmonary opacities were detected on chest CT. Subsequent biopsy revealed extranodal marginal B-cell non-Hodgkin's lymphoma (NHL). An FDG-PET/CT scan was then performed which demonstrated isolated FDG avid pulmonary involvement. After therapy, FDG-PET/CT scans showed good response to treatment with near complete resolution of FDG avidity. This rare case illustrates the rare pulmonary manifestation of extranodal lymphoma in a patient with Sjogren's syndrome and emphasizes the value of FDG PET/CT in the initial staging and evaluation of response to treatment, which has not previously been published. None declared.
- 15 December 2012
- Published by Galenos Yayinevi in Molecular Imaging and Radionuclide Therapy
- Vol. 21 (3) , 117-120
Open AccessRare case of Primary Pulmonary Extranodal Non-Hodgkin’s Lymphoma in a Patient with Sjogrens Syndrome: Role of FDG-PET/CT in the Initial Staging and Evaluating Response to Treatment
A 64-year old woman with a long standing Sjogren's syndrome was undergoing evaluation for renal transplant surgery when two pulmonary opacities were detected on chest CT. Subsequent biopsy revealed extranodal marginal B-cell non-Hodgkin's lymphoma (NHL). An FDG-PET/CT scan was then performed which demonstrated isolated FDG avid pulmonary involvement. After therapy, FDG-PET/CT scans showed good response to treatment with near complete resolution of FDG avidity. This rare case illustrates the rare pulmonary manifestation of extranodal lymphoma in a patient with Sjogren's syndrome and emphasizes the value of FDG PET/CT in the initial staging and evaluation of response to treatment, which has not previously been published. None declared.
- 1 May 2011
- Published by Elsevier in Radiologic Clinics of North America
- Vol. 49 (3) , 425-434
Thyroid: Nuclear Medicine Update
- 1 May 2011
- Published by Elsevier in Radiologic Clinics of North America
- Vol. 49 (3) , 425-434
Thyroid: Nuclear Medicine Update
- 1 February 2007
- Vol. 48 (2) , 221-6
18F-FDG PET/CT in patients with suspected recurrent or metastatic well-differentiated thyroid cancer.
PET using 18F-FDG has been shown to effectively detect various types of cancer by their increased glucose metabolism. The aim of this study was to evaluate the use of coregistered PET and CT (PET/CT) in patients with suspected thyroid cancer recurrence. After total thyroidectomy followed by radioiodine ablation, 61 consecutive patients with elevated thyroglobulin levels or a clinical suspicion of recurrent disease underwent 18F-FDG PET/CT. Of these, 59 patients had negative findings on radioiodine (131I) whole-body scintigraphy (WBS). Fifty-three of the 61 patients had both negative 131I WBS findings and elevated thyroglobulin levels. PET/CT images were acquired 60 min after intravenous injection of 400-610 MBq of 18F-FDG using a combined PET/CT scanner. Any increased 18F-FDG uptake was compared with the coregistered CT image to differentiate physiologic from pathologic tracer uptake. 18F-FDG PET/CT findings were correlated with the findings of histology, postradioiodine WBS, ultrasound, or clinical follow-up serving as a reference. The diagnostic accuracy of 18F-FDG PET/CT was evaluated for the entire patient group and for those patients with serum thyroglobulin levels of less than 5, 5-10, and more than 10 ng/mL. Thirty patients had positive findings on 18F-FDG PET/CT; 26 were true-positive and 4 were false-positive. In 2 patients, increased 18F-FDG uptake identified a second primary malignancy. 18F-FDG PET/CT results were true-negative in 19 patients and false-negative in 12 patients. The overall sensitivity, specificity, and accuracy of 18F-FDG PET/CT were 68.4%, 82.4%, and 73.8%, respectively. The sensitivities of 18F-FDG PET/CT at serum thyroglobulin levels of less than 5, 5-10, and more than 10 ng/mL were 60%, 63%, and 72%, respectively. Clinical management changed for 27 (44%) of 61 patients, including surgery, radiation therapy, or chemotherapy. Coregistered 18F-FDG PET/CT can provide precise anatomic localization of recurrent or metastatic thyroid carcinoma, leading to improved diagnostic accuracy, and can guide therapeutic management. In addition, the findings of this study suggest that further assessment of 131I WBS-negative, thyroglobulin-positive patients by 18F-FDG PET/CT may aid in the clinical management of selected cases regardless of the thyroglobulin level.
- 1 February 2007
- Vol. 48 (2) , 221-6
18F-FDG PET/CT in patients with suspected recurrent or metastatic well-differentiated thyroid cancer.
PET using 18F-FDG has been shown to effectively detect various types of cancer by their increased glucose metabolism. The aim of this study was to evaluate the use of coregistered PET and CT (PET/CT) in patients with suspected thyroid cancer recurrence. After total thyroidectomy followed by radioiodine ablation, 61 consecutive patients with elevated thyroglobulin levels or a clinical suspicion of recurrent disease underwent 18F-FDG PET/CT. Of these, 59 patients had negative findings on radioiodine (131I) whole-body scintigraphy (WBS). Fifty-three of the 61 patients had both negative 131I WBS findings and elevated thyroglobulin levels. PET/CT images were acquired 60 min after intravenous injection of 400-610 MBq of 18F-FDG using a combined PET/CT scanner. Any increased 18F-FDG uptake was compared with the coregistered CT image to differentiate physiologic from pathologic tracer uptake. 18F-FDG PET/CT findings were correlated with the findings of histology, postradioiodine WBS, ultrasound, or clinical follow-up serving as a reference. The diagnostic accuracy of 18F-FDG PET/CT was evaluated for the entire patient group and for those patients with serum thyroglobulin levels of less than 5, 5-10, and more than 10 ng/mL. Thirty patients had positive findings on 18F-FDG PET/CT; 26 were true-positive and 4 were false-positive. In 2 patients, increased 18F-FDG uptake identified a second primary malignancy. 18F-FDG PET/CT results were true-negative in 19 patients and false-negative in 12 patients. The overall sensitivity, specificity, and accuracy of 18F-FDG PET/CT were 68.4%, 82.4%, and 73.8%, respectively. The sensitivities of 18F-FDG PET/CT at serum thyroglobulin levels of less than 5, 5-10, and more than 10 ng/mL were 60%, 63%, and 72%, respectively. Clinical management changed for 27 (44%) of 61 patients, including surgery, radiation therapy, or chemotherapy. Coregistered 18F-FDG PET/CT can provide precise anatomic localization of recurrent or metastatic thyroid carcinoma, leading to improved diagnostic accuracy, and can guide therapeutic management. In addition, the findings of this study suggest that further assessment of 131I WBS-negative, thyroglobulin-positive patients by 18F-FDG PET/CT may aid in the clinical management of selected cases regardless of the thyroglobulin level.
- 1 February 2006
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 31 (2) , 104-105
Herpes Zoster Mimicking Recurrence of Lymphoma on PET/CT
Herpes zoster is a relatively common disease characterized by the eruption of vesicles in a dermatomal distribution. It is postulated to occur when the cell-mediated immunity falls below a critical level, allowing dormant virus to replicate and infect the host. Herpes zoster is known to occur more frequently in immunocompromised groups such as oncology patients receiving chemotherapy and radiation. Patients after stem cell transplant have also been reported to be predisposed to herpes virus infection. F-18-FDG PET is widely used in oncology imaging to determine the presence of metabolic activity in certain malignancies, including lymphoma. However, inflammatory cells can also have high metabolic activity and display avid uptake of FDG. This case illustrates the importance of recognizing the possibility of an inflammatory process such as herpes zoster occurring on PET/CT imaging in an oncology patient being evaluated for malignant disease.
- 1 February 2006
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 31 (2) , 104-105
Herpes Zoster Mimicking Recurrence of Lymphoma on PET/CT
Herpes zoster is a relatively common disease characterized by the eruption of vesicles in a dermatomal distribution. It is postulated to occur when the cell-mediated immunity falls below a critical level, allowing dormant virus to replicate and infect the host. Herpes zoster is known to occur more frequently in immunocompromised groups such as oncology patients receiving chemotherapy and radiation. Patients after stem cell transplant have also been reported to be predisposed to herpes virus infection. F-18-FDG PET is widely used in oncology imaging to determine the presence of metabolic activity in certain malignancies, including lymphoma. However, inflammatory cells can also have high metabolic activity and display avid uptake of FDG. This case illustrates the importance of recognizing the possibility of an inflammatory process such as herpes zoster occurring on PET/CT imaging in an oncology patient being evaluated for malignant disease.
- 1 August 2005
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 30 (8) , 564-568
FDG PET CT Assessment of Treatment Response After Yttrium-90 Ibritumomab Tiuxetan Radioimmunotherapy
Yttrium-90 ibritumomab tiuxetan (Zevalin; IDEC Pharmaceuticals Corp., San Diego, CA) is the first radioimmunotherapy agent approved by the U.S. Food and Drug Administration (FDA) for treatment of non-Hodgkin lymphoma. In a randomized clinical trial comparing Zevalin with rituximab, the overall response rate was 80% and 56%, respectively. Response was determined by assessing the size of lymph nodes on CT scans. FDG PET has been well accepted as an accurate imaging study for staging non-Hodgkin lymphoma and evaluating response to treatment. Simultaneous FDG PET and CT imaging (PET CT) provides coregistered functional PET images with anatomic CT images. We describe 2 cases of non-Hodgkin lymphoma treated in which response was followed using PET CT.
- 1 August 2005
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 30 (8) , 564-568
FDG PET CT Assessment of Treatment Response After Yttrium-90 Ibritumomab Tiuxetan Radioimmunotherapy
Yttrium-90 ibritumomab tiuxetan (Zevalin; IDEC Pharmaceuticals Corp., San Diego, CA) is the first radioimmunotherapy agent approved by the U.S. Food and Drug Administration (FDA) for treatment of non-Hodgkin lymphoma. In a randomized clinical trial comparing Zevalin with rituximab, the overall response rate was 80% and 56%, respectively. Response was determined by assessing the size of lymph nodes on CT scans. FDG PET has been well accepted as an accurate imaging study for staging non-Hodgkin lymphoma and evaluating response to treatment. Simultaneous FDG PET and CT imaging (PET CT) provides coregistered functional PET images with anatomic CT images. We describe 2 cases of non-Hodgkin lymphoma treated in which response was followed using PET CT.