Nan Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nan Yu has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
Sheng-Wey Chiow
Jet Propulsion Laboratory California Institute of Technology 91109 Pasadena CA
9 shared publicationsJason Williams
6 shared publications- Guoping Lin
Harbin Institute of Technology
5 shared publications - Massimo Tinto
Divisão de Astrofísica, Instituto Nacional de Pesquisas Espaciais, S. J. Campos 12227-010, SP, Brazil
4 shared publications - Holger Müller
University of California, Berkeley
3 shared publications James R. Kellogg
Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA, USA
3 shared publications
Latest Publications
- Open Access
Instrument Development for Lunar Interior Investigation Using Atom Interferometry
The Atomic Lunar Seismometer (ALS) is an atom-interferometer instrument concept for measuring the lunar gravity and vibration modes at long time scales. Compared to other seismometer techniques, atom interferometers offer a pathway toward an ultra-low drift seismometer for signals around and below the mHz frequency range. The ALS instrument concept is also applicable to other terrestrial bodies such as Mars. In this paper, we present our instrument design based on a 5 cm tall atomic fountain and summarize the test results obtained in a laboratory environment. This development is specifically to optimize and accommodate in lunar environment. Presently, the instrument’s short-term sensitivity is 1.4 × 10−6 m/s2/ (140 Gal/), limited by the vibration noise in our lab, and it averages down to 6.7 × 10−8 m/s2 (6.7 Gal) after 445 s.Open AccessInstrument Development for Lunar Interior Investigation Using Atom Interferometry
The Atomic Lunar Seismometer (ALS) is an atom-interferometer instrument concept for measuring the lunar gravity and vibration modes at long time scales. Compared to other seismometer techniques, atom interferometers offer a pathway toward an ultra-low drift seismometer for signals around and below the mHz frequency range. The ALS instrument concept is also applicable to other terrestrial bodies such as Mars. In this paper, we present our instrument design based on a 5 cm tall atomic fountain and summarize the test results obtained in a laboratory environment. This development is specifically to optimize and accommodate in lunar environment. Presently, the instrument’s short-term sensitivity is 1.4 × 10−6 m/s2/ (140 Gal/), limited by the vibration noise in our lab, and it averages down to 6.7 × 10−8 m/s2 (6.7 Gal) after 445 s. - Open Access
- 30 June 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-9
Micro mercury trapped ion clock prototypes with 10$^{-14}$ frequency stability in 1-liter packagesModern communication and navigation systems are increasingly relying on atomic clocks. As timing precision requirements increase, demands for lower SWaP (size, weight, and power) clocks rise. However, it has been challenging to break through the general trade-off trend between the clock stability performance and SWaP. Here we demonstrate micro mercury trapped ion clock (M2TIC) prototypes integrated with novel micro-fabricated technologies to simultaneously achieve high performance and low SWaP. The M2TIC prototypes could reach the $$10^{-14}$$ -stability level in 1 day with a SWaP of 1.1 L, 1.2 kg, and under 6 W of power. This stability level is comparable to the widely used rack-mount Microchip 5071A cesium frequency standard. These standalone prototypes survived regular commercial shipping across the North American continent to a government laboratory, where their performance was independently tested. The M2TIC sets a new reference point for SWaP and performance and opens opportunities for high-performance clocks in terrestrial and space applications.- 30 June 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-9
Open AccessMicro mercury trapped ion clock prototypes with 10$^{-14}$ frequency stability in 1-liter packagesModern communication and navigation systems are increasingly relying on atomic clocks. As timing precision requirements increase, demands for lower SWaP (size, weight, and power) clocks rise. However, it has been challenging to break through the general trade-off trend between the clock stability performance and SWaP. Here we demonstrate micro mercury trapped ion clock (M2TIC) prototypes integrated with novel micro-fabricated technologies to simultaneously achieve high performance and low SWaP. The M2TIC prototypes could reach the $$10^{-14}$$ -stability level in 1 day with a SWaP of 1.1 L, 1.2 kg, and under 6 W of power. This stability level is comparable to the widely used rack-mount Microchip 5071A cesium frequency standard. These standalone prototypes survived regular commercial shipping across the North American continent to a government laboratory, where their performance was independently tested. The M2TIC sets a new reference point for SWaP and performance and opens opportunities for high-performance clocks in terrestrial and space applications. - 26 July 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 119 (4) , 044001
Integrated physics package of micromercury trapped ion clock with 10−14-level frequency stability
Mercury trapped ion clocks have demonstrated great long-term frequency stability and robustness. In this paper, we report a demonstration of an integrated 100-cc physics package in an effort to develop a micromercury trapped ion clock with high frequency stability. The physics package consists of a sealed 30-cc vacuum tube with one layer of magnetic shielding, light source, and detector assembly. A field emitter array and a 194-nm microplasma lamp were employed together with a microtrap tube to reduce the size and power consumption for a mercury trapped ion clock. We show that the 100-cc physics package is capable of providing a fractional frequency stability of down to after a few hours of integration. We also show a set of environmental sensitivity evaluations as well as the clock frequency retrace.- 26 July 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 119 (4) , 044001
Integrated physics package of micromercury trapped ion clock with 10−14-level frequency stability
Mercury trapped ion clocks have demonstrated great long-term frequency stability and robustness. In this paper, we report a demonstration of an integrated 100-cc physics package in an effort to develop a micromercury trapped ion clock with high frequency stability. The physics package consists of a sealed 30-cc vacuum tube with one layer of magnetic shielding, light source, and detector assembly. A field emitter array and a 194-nm microplasma lamp were employed together with a microtrap tube to reduce the size and power consumption for a mercury trapped ion clock. We show that the 100-cc physics package is capable of providing a fractional frequency stability of down to after a few hours of integration. We also show a set of environmental sensitivity evaluations as well as the clock frequency retrace.- 9 September 2020
- Published by American Physical Society (APS) in Physical Review D
- Vol. 102 (6) , 062002
Experimental demonstration of time-delay interferometry with optical frequency comb
Heterodyne laser phase measurements in the Laser Interferometer Space Antenna (LISA) are degraded by the phase fluctuations of the onboard clocks, resulting in unacceptable sensitivity performance levels of the interferometric data. The current scheme for cancellation of the clock phase noise requires 1 GHz modulation of the ranging laser beams and additional interspacecraft clock recovery heterodyne phase measurements. Here, we report experimental results for an alternative approach to clock noise cancellation based on modified second generation time-delay interferometry (TDI) with optical frequency combs (OFCs). The use of OFCs in the LISA scheme allows simultaneous cancellation of both laser and clock noises, and would eliminate the need for 1 GHz laser modulations and associated demodulation detections. Two Mach-Zehnder interferometers with acousto-optic modulators were used to simulate two LISA arms with Doppler shifts and time delays. With a self-referenced OFC locked to the laser providing the clock signal, we achieve simultaneous suppression of laser and clock noises by 7 and 1.5 orders of magnitudes, respectively, down to the setup noise floor. Based on a numerical analysis, we further show that the noise suppression performance of the OFC-based TDI scheme can meet the LISA mission requirements with an ample margin.
- 9 September 2020
- Published by American Physical Society (APS) in Physical Review D
- Vol. 102 (6) , 062002
Experimental demonstration of time-delay interferometry with optical frequency comb
Heterodyne laser phase measurements in the Laser Interferometer Space Antenna (LISA) are degraded by the phase fluctuations of the onboard clocks, resulting in unacceptable sensitivity performance levels of the interferometric data. The current scheme for cancellation of the clock phase noise requires 1 GHz modulation of the ranging laser beams and additional interspacecraft clock recovery heterodyne phase measurements. Here, we report experimental results for an alternative approach to clock noise cancellation based on modified second generation time-delay interferometry (TDI) with optical frequency combs (OFCs). The use of OFCs in the LISA scheme allows simultaneous cancellation of both laser and clock noises, and would eliminate the need for 1 GHz laser modulations and associated demodulation detections. Two Mach-Zehnder interferometers with acousto-optic modulators were used to simulate two LISA arms with Doppler shifts and time delays. With a self-referenced OFC locked to the laser providing the clock signal, we achieve simultaneous suppression of laser and clock noises by 7 and 1.5 orders of magnitudes, respectively, down to the setup noise floor. Based on a numerical analysis, we further show that the noise suppression performance of the OFC-based TDI scheme can meet the LISA mission requirements with an ample margin.
- Open Access
- 17 July 2020
- Published by Springer Nature in Nature
- Vol. 584 (7819) , E1
Author Correction: Observation of Bose–Einstein condensates in an Earth-orbiting research lab
An amendment to this paper has been published and can be accessed via a link at the top of the paper.
- 17 July 2020
- Published by Springer Nature in Nature
- Vol. 584 (7819) , E1
Open AccessAuthor Correction: Observation of Bose–Einstein condensates in an Earth-orbiting research lab
An amendment to this paper has been published and can be accessed via a link at the top of the paper.
- 2 April 2020
- Published by American Physical Society (APS) in Physical Review D
- Vol. 101 (8) , 083501
Constraining symmetron dark energy using atom interferometry
The symmetron field is one of the promising candidates of dark energy scalar fields. In all viable candidate field theories, a screening mechanism is implemented to be consistent with existing tests of general relativity. The screening effect in the symmetron theory manifests its influence only to the thin outer layer of a bulk object, where inside a dense material the symmetry of the field is restored and no force exists. For pointlike particles such as atoms, the depth of screening is larger than the size of the particle, such that the screening mechanism is ineffective and the symmetron force is fully expressed on the atomic test particles. Extra force measurements using atom interferometry are thus much more sensitive than bulk mass based measurements, and indeed have placed the most stringent constraints on the parameters characterizing symmetron field in certain region. There is however no clear direct connection between the laboratory measurements and astrophysical observations, where the constraints are far separated by 10 orders of magnitude in the parameter space. In this paper, we present a closed-form expression for the symmetron acceleration of realistic atomic experiments. The expression is validated through numerical simulations for a terrestrial fifth-force experiment using atom interferometry. As a result, we show the connection of the atomic measurement constraints to the astrophysical ones. We also estimate the attainable symmetron constraints from a previously proposed experiment in space intended for a test of chameleon theory. The atomic constraints on the symmetron theory will be further improved by orders of magnitude.
- 2 April 2020
- Published by American Physical Society (APS) in Physical Review D
- Vol. 101 (8) , 083501
Constraining symmetron dark energy using atom interferometry
The symmetron field is one of the promising candidates of dark energy scalar fields. In all viable candidate field theories, a screening mechanism is implemented to be consistent with existing tests of general relativity. The screening effect in the symmetron theory manifests its influence only to the thin outer layer of a bulk object, where inside a dense material the symmetry of the field is restored and no force exists. For pointlike particles such as atoms, the depth of screening is larger than the size of the particle, such that the screening mechanism is ineffective and the symmetron force is fully expressed on the atomic test particles. Extra force measurements using atom interferometry are thus much more sensitive than bulk mass based measurements, and indeed have placed the most stringent constraints on the parameters characterizing symmetron field in certain region. There is however no clear direct connection between the laboratory measurements and astrophysical observations, where the constraints are far separated by 10 orders of magnitude in the parameter space. In this paper, we present a closed-form expression for the symmetron acceleration of realistic atomic experiments. The expression is validated through numerical simulations for a terrestrial fifth-force experiment using atom interferometry. As a result, we show the connection of the atomic measurement constraints to the astrophysical ones. We also estimate the attainable symmetron constraints from a previously proposed experiment in space intended for a test of chameleon theory. The atomic constraints on the symmetron theory will be further improved by orders of magnitude.
- Open Access
Constraining symmetron dark energy using atom interferometry
Symmetron field is one of the promising candidates of dark energy scalar fields. In all viable candidate field theories, a screening mechanism is implemented to be consistent with existing tests of general relativity. The screening effect in the symmetron theory manifests its influence only to the thin outer layer of a bulk object, where inside a dense material the symmetry of the field is restored and no force exists. For pointlike particles such as atoms, the depth of screening is larger than the size of the particle, such that the screening mechanism is ineffective and the symmetron force is fully expressed on the atomic test particles. Extra force measurements using atom interferometry are thus much more sensitive than bulk mass based measurements, and indeed have placed the most stringent constraints on the parameters characterizing symmetron field in certain region. There is however no clear direct connection between the laboratory measurements and astrophysical observations, where the constraints are far separated by 10 orders of magnitude in the parameter space. In this paper, we present a closed-form expression for the symmetron acceleration of realistic atomic experiments. The expression is validated through numerical simulations for a terrestrial fifth-force experiment using atom interferometry. As a result, we show the connection of the atomic measurement constraints to the astrophysical ones. We also estimate the attainable symmetron constraints from a previously proposed experiment in space intended for test of chameleon theory. The atomic constraints on the symmetron theory will be further improved by orders of magnitude.
Open AccessConstraining symmetron dark energy using atom interferometry
Symmetron field is one of the promising candidates of dark energy scalar fields. In all viable candidate field theories, a screening mechanism is implemented to be consistent with existing tests of general relativity. The screening effect in the symmetron theory manifests its influence only to the thin outer layer of a bulk object, where inside a dense material the symmetry of the field is restored and no force exists. For pointlike particles such as atoms, the depth of screening is larger than the size of the particle, such that the screening mechanism is ineffective and the symmetron force is fully expressed on the atomic test particles. Extra force measurements using atom interferometry are thus much more sensitive than bulk mass based measurements, and indeed have placed the most stringent constraints on the parameters characterizing symmetron field in certain region. There is however no clear direct connection between the laboratory measurements and astrophysical observations, where the constraints are far separated by 10 orders of magnitude in the parameter space. In this paper, we present a closed-form expression for the symmetron acceleration of realistic atomic experiments. The expression is validated through numerical simulations for a terrestrial fifth-force experiment using atom interferometry. As a result, we show the connection of the atomic measurement constraints to the astrophysical ones. We also estimate the attainable symmetron constraints from a previously proposed experiment in space intended for test of chameleon theory. The atomic constraints on the symmetron theory will be further improved by orders of magnitude.
- Open Access
Searching for Stochastic Background of Ultra-Light Fields with Atomic Sensors
We propose a cross-correlation method for the searches of ultra-light fields, in particular, with a space network of atomic sensors. The main motivation of the approach is cancellation of uncorrelated noises in the observation data and unique pattern the fields leave on the cross-spectrum, depending on their nature (i.e., scalar, vector or tensor). In particular, we analytically derive a dependence of the cross-spectrum on the angle between two pairs of detectors. We then confirm obtained angular curves with a numerical simulation. We apply the method to the detection of dark matter and gravitational waves.
Open AccessSearching for Stochastic Background of Ultra-Light Fields with Atomic Sensors
We propose a cross-correlation method for the searches of ultra-light fields, in particular, with a space network of atomic sensors. The main motivation of the approach is cancellation of uncorrelated noises in the observation data and unique pattern the fields leave on the cross-spectrum, depending on their nature (i.e., scalar, vector or tensor). In particular, we analytically derive a dependence of the cross-spectrum on the angle between two pairs of detectors. We then confirm obtained angular curves with a numerical simulation. We apply the method to the detection of dark matter and gravitational waves.
- 8 May 2018
- Published by Springer Nature in Applied Physics B
- Vol. 124 (6) , 96
Compact atom interferometer using single laser
- 8 May 2018
- Published by Springer Nature in Applied Physics B
- Vol. 124 (6) , 96
Compact atom interferometer using single laser
- Open Access
- 28 February 2018
- Published by American Physical Society (APS) in Physical Review D
- Vol. 97 (4) , 044043
Multiloop atom interferometer measurements of chameleon dark energy in microgravity
Chameleon field is one of the promising candidates of dark energy scalar fields. As in all viable candidate field theories, a screening mechanism is implemented to be consistent with all existing tests of general relativity. The screening effect in the chameleon theory manifests its influence limited only to the thin outer layer of a bulk object, thus producing extra forces orders of magnitude weaker than that of the gravitational force of the bulk. For pointlike particles such as atoms, the depth of screening is larger than the size of the particle, such that the screening mechanism is ineffective and the chameleon force is fully expressed on the atomic test particles. Extra force measurements using atom interferometry are thus much more sensitive than bulk mass based measurements, and indeed have placed the most stringent constraints on the parameters characterizing chameleon field. In this paper, we present a conceptual measurement approach for chameleon force detection using atom interferometry in microgravity, in which multiloop atom interferometers exploit specially designed periodic modulation of chameleon fields. We show that major systematics of the dark energy force measurements, i.e., effects of gravitational forces and their gradients, can be suppressed below all hypothetical chameleon signals in the parameter space of interest.
- 28 February 2018
- Published by American Physical Society (APS) in Physical Review D
- Vol. 97 (4) , 044043
Open AccessMultiloop atom interferometer measurements of chameleon dark energy in microgravity
Chameleon field is one of the promising candidates of dark energy scalar fields. As in all viable candidate field theories, a screening mechanism is implemented to be consistent with all existing tests of general relativity. The screening effect in the chameleon theory manifests its influence limited only to the thin outer layer of a bulk object, thus producing extra forces orders of magnitude weaker than that of the gravitational force of the bulk. For pointlike particles such as atoms, the depth of screening is larger than the size of the particle, such that the screening mechanism is ineffective and the chameleon force is fully expressed on the atomic test particles. Extra force measurements using atom interferometry are thus much more sensitive than bulk mass based measurements, and indeed have placed the most stringent constraints on the parameters characterizing chameleon field. In this paper, we present a conceptual measurement approach for chameleon force detection using atom interferometry in microgravity, in which multiloop atom interferometers exploit specially designed periodic modulation of chameleon fields. We show that major systematics of the dark energy force measurements, i.e., effects of gravitational forces and their gradients, can be suppressed below all hypothetical chameleon signals in the parameter space of interest.