Zhenxing Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhenxing Liu has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Liguang Wan
College of Electrical Engineering and Automation, Hubei Normal University, Huangshi, 435002, China
3 shared publications - Bin Yang
The Engineering and Technical College of Chengdu University of Technology, LeShan, People’s Republic of China
1 shared publication - Dan Wang
State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
1 shared publication Guangzhou Hu
School of Information Science and Engineering/School of Artificial Intelligence, Wuhan University of Science and Technology, Wuhan 430081, Hubei, People’s Republic of China
1 shared publication- Huajing Fang
Huazhong University of Science and Technology
1 shared publication - Hui-Kang Liu
College of Information Science and Engineering, Wuhan University of Science and Technology, Wuhan, China
1 shared publication
Latest Publications
- 8 May 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (8) , 085107
Research on fire detection method of complex space based on multi-sensor data fusion
Efficient and reliable fire detection methods are essential for addressing complex spatial characteristics of older residential communities, which often face poor fire safety conditions, various fire types, and challenges in rescue operations. In response to the problem of lacking comprehensive analysis of multidimensional data in traditional fire detection, which often leads to false alarms and missed alarms, this paper proposes a fire detection method based on multi-sensor data fusion. Various sensors are employed, including smoke sensors, temperature sensors, CO sensors, and flame sensors. These sensors collect multidimensional data, which are fused using improved adaptive filters and fuzzy Bayesian logical reasoning algorithms to establish a fire detection model based on multi-sensor data fusion. To additionally, false alarms and missed detections caused by sensor damage are further solved by exploring hidden spaces. Experimental results demonstrate that the proposed fire detection system based on multi-sensor data fusion effectively analyses fire occurrence and progression in older residential communities, and performs stability, accuracy and real-time property.
- 8 May 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (8) , 085107
Research on fire detection method of complex space based on multi-sensor data fusion
Efficient and reliable fire detection methods are essential for addressing complex spatial characteristics of older residential communities, which often face poor fire safety conditions, various fire types, and challenges in rescue operations. In response to the problem of lacking comprehensive analysis of multidimensional data in traditional fire detection, which often leads to false alarms and missed alarms, this paper proposes a fire detection method based on multi-sensor data fusion. Various sensors are employed, including smoke sensors, temperature sensors, CO sensors, and flame sensors. These sensors collect multidimensional data, which are fused using improved adaptive filters and fuzzy Bayesian logical reasoning algorithms to establish a fire detection model based on multi-sensor data fusion. To additionally, false alarms and missed detections caused by sensor damage are further solved by exploring hidden spaces. Experimental results demonstrate that the proposed fire detection system based on multi-sensor data fusion effectively analyses fire occurrence and progression in older residential communities, and performs stability, accuracy and real-time property.
- 1 October 2022
- Published by Elsevier in ISA Transactions
- Vol. 129 (Pt A) , 179-192
Multimode function multistability for Cohen-Grossberg neural networks with mixed time delays
- 1 October 2022
- Published by Elsevier in ISA Transactions
- Vol. 129 (Pt A) , 179-192
Multimode function multistability for Cohen-Grossberg neural networks with mixed time delays
- Open Access
Flow Pattern Identification of Oil–Water Two-Phase Flow Based on SVM Using Ultrasonic Testing Method
A flow pattern identification method combining ultrasonic transmission attenuation with an ultrasonic reflection echo is proposed for oil–water two-phase flow in horizontal pipelines. Based on the finite element method, two-dimensional geometric simulation models of typical oil–water two-phase flow patterns are established, using multiphysics coupling simulation technology. An ultrasonic transducer test system of a horizontal pipeline with an inner 50 mm diameter was built, and flow pattern simulation experiments of oil–water two-phase flow were carried out in the tested field area. The simulation results show that the ultrasonic attenuation coefficient is extracted to identify the W/O&O/W dispersion flow using the ultrasonic transmission attenuation method, and the identification accuracy is 100%. By comparison, using the ultrasonic reflection echo method, the echo duration is extracted as an input feature vector of support vector machine (SVM), and the identification accuracy of the stratified flow and dispersed flow is 95.45%. It was proven that the method of the ultrasonic transmission attenuation principle combined with the ultrasonic reflection echo principle can identify oil–water two-phase flow patterns accurately and effectively, which provides a theoretical basis for the flow pattern identification of liquid–liquid multiphase flow.
Open AccessFlow Pattern Identification of Oil–Water Two-Phase Flow Based on SVM Using Ultrasonic Testing Method
A flow pattern identification method combining ultrasonic transmission attenuation with an ultrasonic reflection echo is proposed for oil–water two-phase flow in horizontal pipelines. Based on the finite element method, two-dimensional geometric simulation models of typical oil–water two-phase flow patterns are established, using multiphysics coupling simulation technology. An ultrasonic transducer test system of a horizontal pipeline with an inner 50 mm diameter was built, and flow pattern simulation experiments of oil–water two-phase flow were carried out in the tested field area. The simulation results show that the ultrasonic attenuation coefficient is extracted to identify the W/O&O/W dispersion flow using the ultrasonic transmission attenuation method, and the identification accuracy is 100%. By comparison, using the ultrasonic reflection echo method, the echo duration is extracted as an input feature vector of support vector machine (SVM), and the identification accuracy of the stratified flow and dispersed flow is 95.45%. It was proven that the method of the ultrasonic transmission attenuation principle combined with the ultrasonic reflection echo principle can identify oil–water two-phase flow patterns accurately and effectively, which provides a theoretical basis for the flow pattern identification of liquid–liquid multiphase flow.
- 3 December 2021
- Published by Science China Press., Co. Ltd. in SCIENTIA SINICA Technologica
- Vol. 52 (1) , 180-197
Joint study on health state assessment and degradation trend prediction of industrial equipment
工业设备作为工业互联网的基本组成部分, 其健康状态事关工业产品的质量水平和生产过程的稳定性以及流畅性. 因此, 对工业设备的健康状态进行评估和退化趋势预测具有重要的理论价值和工程实践意义. 本文基于深度学习方法, 拟构建双任务框架, 实现工业设备的健康状态评估和退化趋势预测联合研究. 具体来说, 首先对工业设备的监测信号进行时域和频域特征提取, 使用轻量梯度提升机选择强相关性的特征, 通过主成分分析降维建立健康指标, 并构建健康状态的类别标签; 接着发展领域自适应的迁移学习算法, 即流形空间分布对齐, 将源域和目标域在特征层面进行迁移, 完成源域和目标域的分布对齐; 最后, 融合因果膨胀卷积、双向门控循环单元以及注意力机制技术, 设计了双任务深度网络框架, 实现了工业设备的健康状态评估和退化趋势预测的双功能.本文方法有效解决了单独研究工业设备的健康状态评估或退化趋势预测的缺陷,可以同时对设备进行状态进行实时定性分析(健康状态)和定量分析(剩余使用寿命).最后, 以工业关键部件的轴承和刀具为例,通过和当前流行的深度学习方法比较, 实验结果验证了本文所提的方法能够实现双任务功能以及显著提升退化趋势预测的精度.
- 3 December 2021
- Published by Science China Press., Co. Ltd. in SCIENTIA SINICA Technologica
- Vol. 52 (1) , 180-197
Joint study on health state assessment and degradation trend prediction of industrial equipment
工业设备作为工业互联网的基本组成部分, 其健康状态事关工业产品的质量水平和生产过程的稳定性以及流畅性. 因此, 对工业设备的健康状态进行评估和退化趋势预测具有重要的理论价值和工程实践意义. 本文基于深度学习方法, 拟构建双任务框架, 实现工业设备的健康状态评估和退化趋势预测联合研究. 具体来说, 首先对工业设备的监测信号进行时域和频域特征提取, 使用轻量梯度提升机选择强相关性的特征, 通过主成分分析降维建立健康指标, 并构建健康状态的类别标签; 接着发展领域自适应的迁移学习算法, 即流形空间分布对齐, 将源域和目标域在特征层面进行迁移, 完成源域和目标域的分布对齐; 最后, 融合因果膨胀卷积、双向门控循环单元以及注意力机制技术, 设计了双任务深度网络框架, 实现了工业设备的健康状态评估和退化趋势预测的双功能.本文方法有效解决了单独研究工业设备的健康状态评估或退化趋势预测的缺陷,可以同时对设备进行状态进行实时定性分析(健康状态)和定量分析(剩余使用寿命).最后, 以工业关键部件的轴承和刀具为例,通过和当前流行的深度学习方法比较, 实验结果验证了本文所提的方法能够实现双任务功能以及显著提升退化趋势预测的精度.
- 1 September 2021
- Published by Elsevier in Neurocomputing
- Vol. 454, 212-227
Multiple stability and instability of time-varying delayed fractional-order Cohen-Grossberg neural networks with Gaussian activation functions- 1 September 2021
- Published by Elsevier in Neurocomputing
- Vol. 454, 212-227
Multiple stability and instability of time-varying delayed fractional-order Cohen-Grossberg neural networks with Gaussian activation functions- Open Access
Comprehensive Analysis of Electric Field Characteristics for Multi-Winding Medium Frequency Transformer
The multi-winding medium frequency transformer (MMFT) has attracted widespread attention, since its application in power electronic transformers can simplify the system structure and reduce the volume and weight. However, the special working conditions of MMFT due to high voltage and high power density increase the difficulty of insulation design for MMFT. For this issue, this paper presents a comprehensive analysis of electric filed characteristics for MMFT. First, the electric field model of MMFT is established using the 2-D finite element method. Based on it, the influences of connection mode, core structure, and hollow winding on the electric field characteristics of MMFT are studied, including the overall electric field distribution, maximum electric field intensity, and the electric field intensity along a fixed path. The results show that there are differences in the maximum electric field intensity for different connection modes and different core structures, which provides references for MMFT insulation design. The proposed modeling method and analysis results in this paper are important for insulation improvement of MMFT.
Open AccessComprehensive Analysis of Electric Field Characteristics for Multi-Winding Medium Frequency Transformer
The multi-winding medium frequency transformer (MMFT) has attracted widespread attention, since its application in power electronic transformers can simplify the system structure and reduce the volume and weight. However, the special working conditions of MMFT due to high voltage and high power density increase the difficulty of insulation design for MMFT. For this issue, this paper presents a comprehensive analysis of electric filed characteristics for MMFT. First, the electric field model of MMFT is established using the 2-D finite element method. Based on it, the influences of connection mode, core structure, and hollow winding on the electric field characteristics of MMFT are studied, including the overall electric field distribution, maximum electric field intensity, and the electric field intensity along a fixed path. The results show that there are differences in the maximum electric field intensity for different connection modes and different core structures, which provides references for MMFT insulation design. The proposed modeling method and analysis results in this paper are important for insulation improvement of MMFT.
- 1 November 2020
- Published by Elsevier in Journal of the Franklin Institute
- Vol. 357 (17) , 12742-12766
Multiple stability for fractional-order neural networks with time-varying delays- 1 November 2020
- Published by Elsevier in Journal of the Franklin Institute
- Vol. 357 (17) , 12742-12766
Multiple stability for fractional-order neural networks with time-varying delays- 14 June 2020
- Published by University of Slavonski Brod in Tehnicki vjesnik - Technical Gazette
- Vol. 27 (3) , 898-905
Diagnosis and Location of Open-Circuit Fault in Modular Multilevel Converters Based on High-order Harmonic Analysis
Open-Circuit faults of Submodules (SMs) are the most common fault type of modular multilevel converter (MMC). Thus, in order to improve the reliability of MMC, it is very important to detect and locate faulty MMC SMs. In this paper, a...
- 14 June 2020
- Published by University of Slavonski Brod in Tehnicki vjesnik - Technical Gazette
- Vol. 27 (3) , 898-905
Diagnosis and Location of Open-Circuit Fault in Modular Multilevel Converters Based on High-order Harmonic Analysis
Open-Circuit faults of Submodules (SMs) are the most common fault type of modular multilevel converter (MMC). Thus, in order to improve the reliability of MMC, it is very important to detect and locate faulty MMC SMs. In this paper, a...
- 7 April 2020
- Published by Springer Nature in International Journal of Control, Automation, and Systems
- Vol. 18 (10) , 2522-2533
A GPC-based Multi-variable PID Control Algorithm and Its Application in Anti-swing Control and Accurate Positioning Control for Bridge Cranes
- 7 April 2020
- Published by Springer Nature in International Journal of Control, Automation, and Systems
- Vol. 18 (10) , 2522-2533
A GPC-based Multi-variable PID Control Algorithm and Its Application in Anti-swing Control and Accurate Positioning Control for Bridge Cranes
- 20 January 2012
- Published by Springer Nature in Circuits, Systems, and Signal Processing
- Vol. 31 (4) , 1343-1358
Fault Detection for Nonlinear Networked Control Systems with Markov Data Transmission Pattern
- 20 January 2012
- Published by Springer Nature in Circuits, Systems, and Signal Processing
- Vol. 31 (4) , 1343-1358
Fault Detection for Nonlinear Networked Control Systems with Markov Data Transmission Pattern