Ravindra P. Joshi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ravindra P. Joshi has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
K. H. Schoenbach
Old Dominion University
5 shared publicationsE. Schamiloglu
University of New Mexico Department of Electrical Engineering Albuquerque, New Mexico 87131
4 shared publications- Juergen F. Kolb
Leibniz Institute for Plasma Science and Technology, Felix-Hausdorff-Straße 2, 17489 Greifswald, Germany
4 shared publications J. Gaudet
Dept. of Electrical and Comp. Engr., Univ. of New Mexico, Albuquerque, NM 87131
3 shared publicationsJ. Qian
Dept. of Electrical and Comp. Engr., Old Dominion University, Norfolk, VA 23529
3 shared publicationsQ. Hu
School of Engineering and Technology, Central Michigan University, Mt. Pleasant, Michigan 48859, USA
3 shared publications
Latest Publications
- 1 July 2014
- Published by Elsevier in Biochimica et Biophysica Acta (BBA) - Biomembranes
- Vol. 1838 (7) , 1793-1800
Evaluations of a mechanistic hypothesis for the influence of extracellular ions on electroporation due to high-intensity, nanosecond pulsing
- 1 July 2014
- Published by Elsevier in Biochimica et Biophysica Acta (BBA) - Biomembranes
- Vol. 1838 (7) , 1793-1800
Evaluations of a mechanistic hypothesis for the influence of extracellular ions on electroporation due to high-intensity, nanosecond pulsing
- 1 March 2014
- Published by Elsevier in Biochimica et Biophysica Acta (BBA) - Biomembranes
- Vol. 1838 (3) , 902-909
Numerical study of lipid translocation driven by nanoporation due to multiple high-intensity, ultrashort electrical pulses
- 1 March 2014
- Published by Elsevier in Biochimica et Biophysica Acta (BBA) - Biomembranes
- Vol. 1838 (3) , 902-909
Numerical study of lipid translocation driven by nanoporation due to multiple high-intensity, ultrashort electrical pulses
- 10 May 2013
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 113 (18) , 184504
Leakage current in high dielectric oxides: Role of defect-induced energies
Model evaluations of field-dependent leakage currents in the high-k dielectric oxides HfO2 and ZrO2 are presented. The treatment includes a number of competing transport processes on an equal footing. Our simulation results show that trap-assisted-tunneling, though important, is not the most significant contributor. The combined Poole-Frenkel mechanism with modifications from inelastic trap-related processes dominates at electric fields above 1.5 MV/cm. Our model predictions compare very favorably against the reported experimental data for both HfO2 and ZrO2. Finally, results obtained from the density functional theory based castep simulator are suggestive of dynamic changes in the net energy levels and the possible formation of a mini-band due to oxygen vacancies.
- 10 May 2013
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 113 (18) , 184504
Leakage current in high dielectric oxides: Role of defect-induced energies
Model evaluations of field-dependent leakage currents in the high-k dielectric oxides HfO2 and ZrO2 are presented. The treatment includes a number of competing transport processes on an equal footing. Our simulation results show that trap-assisted-tunneling, though important, is not the most significant contributor. The combined Poole-Frenkel mechanism with modifications from inelastic trap-related processes dominates at electric fields above 1.5 MV/cm. Our model predictions compare very favorably against the reported experimental data for both HfO2 and ZrO2. Finally, results obtained from the density functional theory based castep simulator are suggestive of dynamic changes in the net energy levels and the possible formation of a mini-band due to oxygen vacancies.
- 7 March 2013
- Published by American Physical Society (APS) in Physical Review E
- Vol. 87 (3) , 032704
Physics of nanoporation and water entry driven by a high-intensity, ultrashort electrical pulse in the presence of membrane hydrophobic interactions
The electroporation process in response to a high-intensity, ultrashort (∼ns) electric pulse is probed based on molecular-dynamics simulations and shown to be a very rapid, twofold process. The electric driving force produces a Maxwell stress at the membrane and works to rearrange lipid dipoles and cause openings. However, water entry, which is essential for useful transport, is facilitated by electrowetting, which is an important component of the overall process. The molecular system can thus function as an electrically driven hydrophobic toggle switch that changes the water permeability. Furthermore, our results show that once they are fully formed, the nanopores do not close rapidly after cessation of the external electric field, in keeping with recent experiments. Finally, it is suggested that multiple pore formation in close proximity, as in situations involving high driving electric fields, is likely to be a rapid sequential process.
- 7 March 2013
- Published by American Physical Society (APS) in Physical Review E
- Vol. 87 (3) , 032704
Physics of nanoporation and water entry driven by a high-intensity, ultrashort electrical pulse in the presence of membrane hydrophobic interactions
The electroporation process in response to a high-intensity, ultrashort (∼ns) electric pulse is probed based on molecular-dynamics simulations and shown to be a very rapid, twofold process. The electric driving force produces a Maxwell stress at the membrane and works to rearrange lipid dipoles and cause openings. However, water entry, which is essential for useful transport, is facilitated by electrowetting, which is an important component of the overall process. The molecular system can thus function as an electrically driven hydrophobic toggle switch that changes the water permeability. Furthermore, our results show that once they are fully formed, the nanopores do not close rapidly after cessation of the external electric field, in keeping with recent experiments. Finally, it is suggested that multiple pore formation in close proximity, as in situations involving high driving electric fields, is likely to be a rapid sequential process.
- Top Cited Papers
- 20 January 2013
- Published by Springer Nature in Plasma Chemistry and Plasma Processing
- Vol. 33 (1) , 17-49
Streamer-Like Electrical Discharges in Water: Part II. Environmental Applications
- 20 January 2013
- Published by Springer Nature in Plasma Chemistry and Plasma Processing
- Vol. 33 (1) , 17-49
Top Cited PapersStreamer-Like Electrical Discharges in Water: Part II. Environmental Applications
- 27 November 2012
- Published by Springer Nature in Plasma Chemistry and Plasma Processing
- Vol. 33 (1) , 1-15
Streamer-Like Electrical Discharges in Water: Part I. Fundamental Mechanisms
- 27 November 2012
- Published by Springer Nature in Plasma Chemistry and Plasma Processing
- Vol. 33 (1) , 1-15
Streamer-Like Electrical Discharges in Water: Part I. Fundamental Mechanisms
- 15 September 2012
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 112 (6) , 064703
Role of electropores on membrane blebbing—A model energy-based analysis
Cell blebbing has been observed invitro in the context of external intense electric field pulsing of biological cells. Here, we propose that this is promoted in part by the formation of electropores that influence the membrane tension. Model energy-based calculations of bleb formation are presented. It is shown that the high density of electropores (with radii around 1 nm) driven by a nanosecond voltage pulse could lead to quasi-stable 1 μm blebs, and that the preferred site for bleb formation would predominantly be near the polar caps facing the electrodes. This is in keeping with recent experimental reports. Our study has implications to pore closing and their lifetimes, an aspect important for intracellular drug delivery.
- 15 September 2012
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 112 (6) , 064703
Role of electropores on membrane blebbing—A model energy-based analysis
Cell blebbing has been observed invitro in the context of external intense electric field pulsing of biological cells. Here, we propose that this is promoted in part by the formation of electropores that influence the membrane tension. Model energy-based calculations of bleb formation are presented. It is shown that the high density of electropores (with radii around 1 nm) driven by a nanosecond voltage pulse could lead to quasi-stable 1 μm blebs, and that the preferred site for bleb formation would predominantly be near the polar caps facing the electrodes. This is in keeping with recent experimental reports. Our study has implications to pore closing and their lifetimes, an aspect important for intracellular drug delivery.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 58 (10) , 2860-2866
Case for Applying Subnanosecond High-Intensity, Electrical Pulses to Biological Cells
In this paper, model analysis into the time-dependent transmembrane potential at the outer cell membrane is presented, for applied high-intensity electric pulses having durations in the nanosecond range or smaller. It is argued that the frequency-dependent dielectric response of cell membranes could be used to advantage for stronger bioeffects by employing shorter pulses. Our model calculations predict faster transmembrane voltages and larger electroporation densities for a given external energy with pulse durations in the subnanosecond regime. This temporal regime would be used, for example, in the electrotherapy of mixed cell ensembles having different dielectric response properties.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 58 (10) , 2860-2866
Case for Applying Subnanosecond High-Intensity, Electrical Pulses to Biological Cells
In this paper, model analysis into the time-dependent transmembrane potential at the outer cell membrane is presented, for applied high-intensity electric pulses having durations in the nanosecond range or smaller. It is argued that the frequency-dependent dielectric response of cell membranes could be used to advantage for stronger bioeffects by employing shorter pulses. Our model calculations predict faster transmembrane voltages and larger electroporation densities for a given external energy with pulse durations in the subnanosecond regime. This temporal regime would be used, for example, in the electrotherapy of mixed cell ensembles having different dielectric response properties.
- 22 February 2011
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 49 (6) , 713-718
Synergistic effects of local temperature enhancements on cellular responses in the context of high-intensity, ultrashort electric pulses
Results of self-consistent analyses of cells show the possibility of temperature increases at membranes in response to a single nanosecond, high-voltage pulse, at least over small sections of the membrane. Molecular Dynamics simulations indicate that such a temperature increase could facilitate poration, which is one example of a bio-process at the plasma membrane. Our study thus suggests that the use of repetitive high-intensity voltage pulses could open up possibilities for a host of synergistic bio-responses involving both thermal and electrically driven phenomena.
- 22 February 2011
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 49 (6) , 713-718
Synergistic effects of local temperature enhancements on cellular responses in the context of high-intensity, ultrashort electric pulses
Results of self-consistent analyses of cells show the possibility of temperature increases at membranes in response to a single nanosecond, high-voltage pulse, at least over small sections of the membrane. Molecular Dynamics simulations indicate that such a temperature increase could facilitate poration, which is one example of a bio-process at the plasma membrane. Our study thus suggests that the use of repetitive high-intensity voltage pulses could open up possibilities for a host of synergistic bio-responses involving both thermal and electrically driven phenomena.
- 16 July 2010
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 48 (9) , 837-844
Analysis of cell membrane permeabilization mechanics and pore shape due to ultrashort electrical pulsing
Cell membrane permeabilization mechanics and the resulting shape of nanopores in response to electrical pulsing are probed based on a continuum approach. This has implications for electropermeabilization and cell membrane transport. It is argued that small pores resulting from high-intensity (~100 kV/cm), nanosecond pulsing would have an initial asymmetric shape. This would lead to asymmetric membrane current–voltage characteristics, at least at early times. The role of the cytoskeleton is ignored here, but can be expected to additionally contribute to such asymmetries. Furthermore, we show that the pore shape and membrane conduction would be dynamic, and evolve toward a symmetric characteristic over time. This duration has been shown to be in the micro-second range.
- 16 July 2010
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 48 (9) , 837-844
Analysis of cell membrane permeabilization mechanics and pore shape due to ultrashort electrical pulsing
Cell membrane permeabilization mechanics and the resulting shape of nanopores in response to electrical pulsing are probed based on a continuum approach. This has implications for electropermeabilization and cell membrane transport. It is argued that small pores resulting from high-intensity (~100 kV/cm), nanosecond pulsing would have an initial asymmetric shape. This would lead to asymmetric membrane current–voltage characteristics, at least at early times. The role of the cytoskeleton is ignored here, but can be expected to additionally contribute to such asymmetries. Furthermore, we show that the pore shape and membrane conduction would be dynamic, and evolve toward a symmetric characteristic over time. This duration has been shown to be in the micro-second range.