MSMark Spengler

Mark Spengler

*This is an algorithmically generated author record based on publicly available information.

Mark Spengler has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Immuno-PCR with digital readout

    by Hendrik Schröder, Maximilian Grösche, Michael Adler, Mark Spengler, Christof M. Niemeyer


  • Open Access

    Bioanalytical PK support for Immunotherapeutics: The need for sensitivity combined with broad assay range - Case studies

    by Christian Pieper, Beena Punnamoottil, Nina Juergens, Andreas Jonas, Michael Adler, Mark Spengler

    Purpose: Immunotherapeutic concepts play an increasingly important role in modern drug development. Dosing of high efficient antibodies, the most common class of immune-modulatory drugs, is challenging. Therapeutic dosing regime may vary significantly, depending on safety, binding targets, potency, clearance rate, physiological effects, and other considerations. Hence, for optimal trial support, assay range of the supporting method is key, addressing both, high and low dosing. Methods: Here we evaluate DNA-enhanced (Immuno-PCR/Imperacer) state-of-the-art bioanalytical approaches for GxP regulated study support with broad dynamic quantification range. Target-specific antibody-DNA conjugates were applied for subsequent exponential signal amplification with PCR (Polymerase Chain Reaction). Results: In analysis of case studies from the development of immunotherapeutic compounds, detection range from sub-ng/ ml up to μg/ml target concentrations in biological matrix is demonstrated. Accuracy and precision of the assays were well in accordance with current guideline requirements in assay validation. Any source sample dilution furthermore enhances assay robustness and enables compatibility with limited sample volume availability, as typical in e.g. ophthalmology. Conclusions: Imperacer technology provides sufficient sensitivity, continuous dynamic range, and GxP compliance for analysis of immunotherapeutic drugs. This analysis strategy also opens up additional applications such as polyplex quantification of multiple analytes (e.g. drug and target) from one sample and/or microsampling sample volume reduction (<10 μl for duplicate analysis).

  • Open Access

    Imperacer (Immuno-PCR) method for ultra sensitive quantification of Interleukin-6 to support clinical phase III trial

    by Mark Spengler, Michael Adler, Christian Pieper

    Purpose: Phamacodynamic (PD) markers such as cytokine Interleukin-6 (IL-6) have great impact on biotherapeutics development. Patient levels can vary between sub-pg/ml up to ng/ml concentrations, thereby surpassing narrow detection windows of standard ligand-binding assay (LBA) technologies. Additionally, available sample volume (e.g. from small animals or multi-analyte studies) can be limited to 4 orders of magnitude dynamic quantification range (up to 5 ng/ml), selectivity in spiked and non-spiked individuals, and confirmed parallelism in serial 2fold and 3fold dilution of endogenous target. Up to 10 replicates for analysis were generated from 100 μl sample volume in robust study sample analysis (>13,000 samples). Microsampling evaluation also revealed specific separation of healthy/diseased individuals. Conclusions: IL-6 Imperacer enabled flexible PD biomarker assessment in pre-clinical research setting (microsampling) and clinical study support (validated high-throughput routine analysis). Imperacer technology is thereby a versatile tool for biotherapeutics development. Methods: We describe IL-6 Imperacer bioanalytical method development and validation in support of clinical phase III trials for autoimmune disorder therapies. Imperacer applies antibody-DNA detection conjugates and subsequent DNA amplification for high sensitivity and broad quantitative dynamic range. The assay was adapted to study requirements and validated for human serum and plasma samples from healthy and diseased individuals, respectively. An additional microsampling research protocol was evaluated, requiring only 1 µl sample for intra-assay double determination Results: IL-6 Imperacer complies to relevant guidelines for biomarker assays with lower limit of quantification (LLOQ) at 0.31 pg/ml, >4 orders of magnitude dynamic quantification range (up to 5 ng/ml), selectivity in spiked and non-spiked individuals, and confirmed parallelism in serial 2fold and 3fold dilution of endogenous target. Up to 10 replicates for analysis were generated from 100 µl sample volume in robust study sample analysis (>13,000 samples). Microsampling evaluation also revealed specific separation of healthy/diseased individuals. Conclusions: IL-6 Imperacer enabled flexible PD biomarker assessment in pre-clinical research setting (microsampling) and clinical study support (validated high-throughput routine analysis). Imperacer technology is thereby a versatile tool for biotherapeutics development.


  • Open Access

    Development of an Imperacer (Immuno-PCR) assay combining broad assay range and excellent sensitivity to support development of an immuno modulator antibody drug

    by Shuangping Shi, Mark Spengler, Beena Punnamoottil, Michael Adler, Don (Dong-Hun) Lee

    Purpose: Biologics such as therapeutic antibody drugs are often administered in wide concentration ranges for dose-response evaluation. Safety and potency considerations demand low dosing in clinical trials. In contrast, higher dosing is applied in preclinical safety assessment for fast cleared drugs. Thus, sensitive pharmacokinetic analysis with broad quantification range is required. Method: An Imperacer assay for quantification of a therapeutic antibody for cancer treatment was developed. The assay applies tailored antibody-DNA conjugates for target detection and subsequent exponential DNA amplification for signal generation. Results: A quantification range of 2 – 32,768 pg/ml target antibody was demonstrated with accuracy and precision 5 μg/ml can be diluted into the assay range with acceptable recovery despite Prozone (hook) effect starting at approx. 1 μg/ml. Conclusions: Exponential signal amplification provides a combination of excellent sensitivity and broad assay range for the Imperacer platform. As only one assay is required for >5 orders of magnitude target concentration, the need for multiple quantification windows in different technologies is circumvented. This significantly reduces bioanalytical sample testing time and effort during all phases in the development of Biologics. Assay optimization is still in progress and will be adapted towards further study requirements prior to method validation.

  • Open Access

    Highly sensitive ligand-binding assays in pre-clinical and clinical applications: immuno-PCR and other emerging techniques

    by Mark Spengler, Michael Adler, Christof M. Niemeyer

    Emerging state-of-the-art ligand-binding assay technologies for pharmaceutical sample testing are surveyed, which reveal enhanced analytical sensitivity over classical ELISA formats.


  • Immuno-PCR assays for immunogenicity testing

    by Mark Spengler, Michael Adler, Andreas Jonas, Christof M. Niemeyer


  • Open Access

    Cover Picture: Screening for Cytochrome P450 Reactivity by Harnessing Catalase as Reporter Enzyme (ChemBioChem 4/2009)

    by Kersten S. Rabe, Mark Spengler, Michael Erkelenz, Joachim Müller, Valerie J. Gandubert, Heiko Hayen, Christof M. Niemeyer