Sharif Al-Ruzzeh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Sharif Al-Ruzzeh has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Mohamed Amrani
National Heart and Lung Institute, Heart Science Centre, Harefield Hospital, Harefield , Middlesex UB9 6JH, UK
4 shared publications Charles Ilsley
The National Heart and Lung Institute, Imperial College of Science, Technology and Medicine, Harefield Hospital, Middlesex, United Kingdom
3 shared publicationsMohamed Amrani
The National Heart and Lung Institute, Imperial College of Science, Technology and Medicine, Harefield Hospital, Middlesex, United Kingdom
3 shared publicationsChristophe Decoene
Service d'anesthésie-réanimation cardiologique, Hopital cardiologique, CHRU de Lille, France
2 shared publicationsKoki Nakamura
The National Heart and Lung Institute, Imperial College of Science, Technology and Medicine, Harefield Hospital, Middlesex, UK
2 shared publicationsNandor Marczin
Imperial College London
2 shared publications
Latest Publications
- 1 June 2011
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 25 (3) , S19
O-44 Release of heparin binding protein during cardiac surgery: a new mediator of systemic inflammatory response?
- 1 June 2011
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 25 (3) , S19
O-44 Release of heparin binding protein during cardiac surgery: a new mediator of systemic inflammatory response?
- 22 September 2009
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 209 (5) , 659-667
The “Off-Label” Role of Recombinant Factor VIIa in Surgery: Is the Problem Deficient Evidence or Defective Concept?
- 22 September 2009
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 209 (5) , 659-667
The “Off-Label” Role of Recombinant Factor VIIa in Surgery: Is the Problem Deficient Evidence or Defective Concept?
- Open Access
- 19 May 2009
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 9 (2) , 203-208
The first Latin-American risk stratification system for cardiac surgery: can be used as a graphic pocket-card score
This study aims to develop the first Latin-American risk model that can be used as a simple, pocket-card graphic score at bedside. The risk model was developed on 2903 patients who underwent cardiac surgery at the Spanish Hospital of Buenos Aires, Argentina, between June 1994 and December 1999. Internal validation was performed on 708 patients between January 2000 and June 2001 at the same center. External validation was performed on 1087 patients between February 2000 and January 2007 at three other centers in Argentina. In the development dataset the area under receiver operating characteristics (ROC) curve was 0.73 and the Hosmer–Lemeshow (HL) test was P=0.88. In the internal validation ROC curve was 0.77. In the external validation ROC curve was 0.81, but imperfect calibration was detected because the observed in-hospital mortality (3.96%) was significantly lower than the development dataset (8.20%) (PP=0.92). This is the first risk model for cardiac surgery developed in a population of Latin-America with both internal and external validation. A simple graphic pocket-card score allows an easy bedside application with acceptable statistic precision.
- 19 May 2009
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 9 (2) , 203-208
Open AccessThe first Latin-American risk stratification system for cardiac surgery: can be used as a graphic pocket-card score
This study aims to develop the first Latin-American risk model that can be used as a simple, pocket-card graphic score at bedside. The risk model was developed on 2903 patients who underwent cardiac surgery at the Spanish Hospital of Buenos Aires, Argentina, between June 1994 and December 1999. Internal validation was performed on 708 patients between January 2000 and June 2001 at the same center. External validation was performed on 1087 patients between February 2000 and January 2007 at three other centers in Argentina. In the development dataset the area under receiver operating characteristics (ROC) curve was 0.73 and the Hosmer–Lemeshow (HL) test was P=0.88. In the internal validation ROC curve was 0.77. In the external validation ROC curve was 0.81, but imperfect calibration was detected because the observed in-hospital mortality (3.96%) was significantly lower than the development dataset (8.20%) (PP=0.92). This is the first risk model for cardiac surgery developed in a population of Latin-America with both internal and external validation. A simple graphic pocket-card score allows an easy bedside application with acceptable statistic precision.
- 1 October 2008
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 22 (5) , 783-785
Con: The Role of Recombinant Factor VIIa in the Control of Bleeding After Cardiac Surgery
- 1 October 2008
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 22 (5) , 783-785
Con: The Role of Recombinant Factor VIIa in the Control of Bleeding After Cardiac Surgery
- Open Access
- 1 January 2007
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 83 (1) , 355-6
Caution With the Use of Recombinant Activated Factor VII in Treating Postoperative Hemorrhage in Cardiac Surgery
- 1 January 2007
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 83 (1) , 355-6
Open AccessCaution With the Use of Recombinant Activated Factor VII in Treating Postoperative Hemorrhage in Cardiac Surgery
- 1 April 2006
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 14 (2) , 155-157
A Technical Failure Changes a Y-graft into a C-conduit Causing Steal Syndrome
Y-grafting is a common coronary grafting technique for performing composite coronary grafts. The outcome and efficacy of this technique have not been studied in detail in the literature. We report a case of an occlusion in the proximal limb of a Y-graft, changing it into a C-shaped conduit and causing a steal syndrome. Our aim is to raise the level of caution when performing this type of composite graft and to suggest how this complication can be managed postoperatively.
- 1 April 2006
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 14 (2) , 155-157
A Technical Failure Changes a Y-graft into a C-conduit Causing Steal Syndrome
Y-grafting is a common coronary grafting technique for performing composite coronary grafts. The outcome and efficacy of this technique have not been studied in detail in the literature. We report a case of an occlusion in the proximal limb of a Y-graft, changing it into a C-shaped conduit and causing a steal syndrome. Our aim is to raise the level of caution when performing this type of composite graft and to suggest how this complication can be managed postoperatively.
- Open Access
Predictors of poor mid-term health related quality of life after primary isolated coronary artery bypass grafting surgery
Objective: To assess the determinants of poor mid-term health related quality of life (HRQoL) at one year after primary isolated coronary artery bypass grafting (CABG). Methods: 463 patients who underwent primary isolated CABG for multivessel disease and came for their annual follow up at the outpatient clinic during one year at Harefield Hospital, Middlesex, were approached to participate in the present study. Prospective clinical data were collected as part of the clinical care of the patients and were retrospectively analysed when the patients consented to participate in the study at their outpatient visit. After their consent they were given three HRQoL assessment questionnaires. Scores, together with clinical data, were analysed by both univariate and multivariate analyses with regard to poor HRQoL outcome. Results: 437 (94.4%) patients consented to participate in the study and filled in the HRQoL questionnaires. Ten variables were identified in the univariate analysis as potential predictors of poor scores of the physical element of HRQoL; however, only three variables—gastrointestinal problems, congestive heart failure, and type D personality trait—predicted poor physical scores independently. Eleven variables were identified in the univariate analysis as potential predictors of poor scores of the mental element of HRQoL; however, only three variables—peripheral vascular disease, infective complications, and type D personality trait—predicted poor physical scores independently. Conclusion: Preoperative gastrointestinal problems, preoperative congestive heart failure, and type D personality trait were independent predictors of the poor physical component of HRQoL. Peripheral vascular disease, infective complications, and type D personality trait were independent predictors of the poor mental component of HRQoL. Interestingly, patients with type D personality were more than twice as likely to have poor physical HRQoL and more than five times as likely to have poor mental HRQoL.
Open AccessPredictors of poor mid-term health related quality of life after primary isolated coronary artery bypass grafting surgery
Objective: To assess the determinants of poor mid-term health related quality of life (HRQoL) at one year after primary isolated coronary artery bypass grafting (CABG). Methods: 463 patients who underwent primary isolated CABG for multivessel disease and came for their annual follow up at the outpatient clinic during one year at Harefield Hospital, Middlesex, were approached to participate in the present study. Prospective clinical data were collected as part of the clinical care of the patients and were retrospectively analysed when the patients consented to participate in the study at their outpatient visit. After their consent they were given three HRQoL assessment questionnaires. Scores, together with clinical data, were analysed by both univariate and multivariate analyses with regard to poor HRQoL outcome. Results: 437 (94.4%) patients consented to participate in the study and filled in the HRQoL questionnaires. Ten variables were identified in the univariate analysis as potential predictors of poor scores of the physical element of HRQoL; however, only three variables—gastrointestinal problems, congestive heart failure, and type D personality trait—predicted poor physical scores independently. Eleven variables were identified in the univariate analysis as potential predictors of poor scores of the mental element of HRQoL; however, only three variables—peripheral vascular disease, infective complications, and type D personality trait—predicted poor physical scores independently. Conclusion: Preoperative gastrointestinal problems, preoperative congestive heart failure, and type D personality trait were independent predictors of the poor physical component of HRQoL. Peripheral vascular disease, infective complications, and type D personality trait were independent predictors of the poor mental component of HRQoL. Interestingly, patients with type D personality were more than twice as likely to have poor physical HRQoL and more than five times as likely to have poor mental HRQoL.
- 9 August 2005
- Published by Hindawi Limited in Journal of Cardiac Surgery
- Vol. 20 (6) , 507-511
Acute Effect of Cerivastatin on Cardiac Regional Ischemia in a Rat Model Mimicking Off-Pump Coronary Surgery
Background: Although the off‐pump technique is becoming widely used in coronary bypass surgery, there has been no experimental rat heart model of regional reversible ischemia. The aims of this study were to investigate the optimal duration of coronary occlusion for making reversible ischemia and to examine whether cerivastatin increases myocardial tolerance against prolonged coronary occlusion. Methods: Study 1—Male Sprague‐Dawley rats (350 to 450 g) underwent temporary occlusion of either left anterior descending artery (LAD; for 3, 5, 7.5, 10, 12.5, 15, or 20 min) or circumflex artery (CX; for 5, 10, or 15 min). Study 2—Rats were divided into two groups, control and cerivastatin groups, which had 0.1 mg/kg cerivastatin intravenously after anesthesia. LAD was occluded for 10, 15, or 20 minutes. In the both studies, hearts were stained to determine the area at risk (AR) and infarcted (IF) area 24 hours after reperfusion. Results: In LAD occlusion, IF/AR increased in a time dependent manner: 4.5 ± 3.2%, 9.7 ± 5.2%, 17.2 ± 3.0%, 16.8 ± 2.7%, 23.9 ± 9.5% (p < 0.01 vs. 3 min), 62.4 ± 2.9% (p < 0.0001), and 63.4 ± 2.9% (p < 0.0001) at 3, 5, 7.5, 10, 12.5, 15, and 20 min, respectively. Also in CX, IF/AR increased with time: 14.3 ± 2.3%, 25.9 ± 2.1%, and 40.9 ± 6.2% (p < 0.001 vs. 5 min) at 5, 10, and 15 min, respectively. Cerivastatin significantly reduced IF/AR at 15 minutes (43.7 ± 6.2%) and at 20 minutes (44.6 ± 5.3%) compared to control (62.4 ± 2.9% and 60.6 ± 2.5%, respectively, p < 0.05). Conclusion: Cerivastatin increased myocardial tolerance after prolonged coronary occlusion over 10 minutes, which was considered to be the upper limit for creating a regional reversible ischemia in rats.
- 9 August 2005
- Published by Hindawi Limited in Journal of Cardiac Surgery
- Vol. 20 (6) , 507-511
Acute Effect of Cerivastatin on Cardiac Regional Ischemia in a Rat Model Mimicking Off-Pump Coronary Surgery
Background: Although the off‐pump technique is becoming widely used in coronary bypass surgery, there has been no experimental rat heart model of regional reversible ischemia. The aims of this study were to investigate the optimal duration of coronary occlusion for making reversible ischemia and to examine whether cerivastatin increases myocardial tolerance against prolonged coronary occlusion. Methods: Study 1—Male Sprague‐Dawley rats (350 to 450 g) underwent temporary occlusion of either left anterior descending artery (LAD; for 3, 5, 7.5, 10, 12.5, 15, or 20 min) or circumflex artery (CX; for 5, 10, or 15 min). Study 2—Rats were divided into two groups, control and cerivastatin groups, which had 0.1 mg/kg cerivastatin intravenously after anesthesia. LAD was occluded for 10, 15, or 20 minutes. In the both studies, hearts were stained to determine the area at risk (AR) and infarcted (IF) area 24 hours after reperfusion. Results: In LAD occlusion, IF/AR increased in a time dependent manner: 4.5 ± 3.2%, 9.7 ± 5.2%, 17.2 ± 3.0%, 16.8 ± 2.7%, 23.9 ± 9.5% (p < 0.01 vs. 3 min), 62.4 ± 2.9% (p < 0.0001), and 63.4 ± 2.9% (p < 0.0001) at 3, 5, 7.5, 10, 12.5, 15, and 20 min, respectively. Also in CX, IF/AR increased with time: 14.3 ± 2.3%, 25.9 ± 2.1%, and 40.9 ± 6.2% (p < 0.001 vs. 5 min) at 5, 10, and 15 min, respectively. Cerivastatin significantly reduced IF/AR at 15 minutes (43.7 ± 6.2%) and at 20 minutes (44.6 ± 5.3%) compared to control (62.4 ± 2.9% and 60.6 ± 2.5%, respectively, p < 0.05). Conclusion: Cerivastatin increased myocardial tolerance after prolonged coronary occlusion over 10 minutes, which was considered to be the upper limit for creating a regional reversible ischemia in rats.
- 10 January 2005
- Published by Hindawi Limited in Journal of Cardiac Surgery
- Vol. 20 (1) , 22-28
Differential Effect of Cerivastatin and L-Arginine on the Vascular Function of Human Radial and Left Internal Thoracic Arteries
Background: There are a number of strategies to restore/preserve endothelial function. We have compared the effects of Cerivastatin (CS) to those of L‐arginine (L‐ARG) supplementation on the endothelial function of human arterial grafts. Methods: During coronary artery bypass grafting, specimens of radial artery (RA) and left internal thoracic artery (LITA) were obtained. Specimens were divided into vascular rings, which were incubated with either 10−6 mol/L CS, 10−3 mol/L L‐ARG, or vehicle (control) for 2 or 24 hours. Endothelial function was examined with acethylcholine (10−9 to 10−5 mol/L) following contraction by 3 × 10−8 mol/L endothelin‐1. Results: Although no significant differences were observed in the RA at 2 hours, after 24 hours incubation, endothelium‐dependent vasodilatation was significantly higher in CS group (68.4 ± 5.0%; n = 6) compared to L‐ARG group (49.9 ± 5.4%; n = 7, p < 0.05) and control group (33.8 ± 2.9%; n = 13, p < 0.0001). In addition, there was a significant increase in L‐ARG group compared to control (p < 0.01). After 2 hours incubation of the LITA, CS failed to enhance endothelium‐dependent vasodilatation compared to control (44.1 ± 4.9%; n = 9, vs. 40.0 ± 5.2%; n = 16, respectively, NS), while L‐ARG increased it (64.7 ± 4.9%; n = 7, p < 0.05 vs. CS and p < 0.01 vs. control). However, this increase disapeared at 24 hours although there was a higher trend of endothelium‐dependent vasodilatation in CS group (30.3 ± 3.7%; n = 8 in L‐ARG, 56.5 ± 8.8%; n = 9 in CS and 41.0 ± 5.5%; n = 18 in control). Conclusions: CS preserved endothelium‐dependent vasodilatation of RA greater than L‐ARG. These findings suggest that the use of statins may be an effective therapeutic strategy to preserve endothelial function in the RA grafts, and could have important implications in the clinical practice.
- 10 January 2005
- Published by Hindawi Limited in Journal of Cardiac Surgery
- Vol. 20 (1) , 22-28
Differential Effect of Cerivastatin and L-Arginine on the Vascular Function of Human Radial and Left Internal Thoracic Arteries
Background: There are a number of strategies to restore/preserve endothelial function. We have compared the effects of Cerivastatin (CS) to those of L‐arginine (L‐ARG) supplementation on the endothelial function of human arterial grafts. Methods: During coronary artery bypass grafting, specimens of radial artery (RA) and left internal thoracic artery (LITA) were obtained. Specimens were divided into vascular rings, which were incubated with either 10−6 mol/L CS, 10−3 mol/L L‐ARG, or vehicle (control) for 2 or 24 hours. Endothelial function was examined with acethylcholine (10−9 to 10−5 mol/L) following contraction by 3 × 10−8 mol/L endothelin‐1. Results: Although no significant differences were observed in the RA at 2 hours, after 24 hours incubation, endothelium‐dependent vasodilatation was significantly higher in CS group (68.4 ± 5.0%; n = 6) compared to L‐ARG group (49.9 ± 5.4%; n = 7, p < 0.05) and control group (33.8 ± 2.9%; n = 13, p < 0.0001). In addition, there was a significant increase in L‐ARG group compared to control (p < 0.01). After 2 hours incubation of the LITA, CS failed to enhance endothelium‐dependent vasodilatation compared to control (44.1 ± 4.9%; n = 9, vs. 40.0 ± 5.2%; n = 16, respectively, NS), while L‐ARG increased it (64.7 ± 4.9%; n = 7, p < 0.05 vs. CS and p < 0.01 vs. control). However, this increase disapeared at 24 hours although there was a higher trend of endothelium‐dependent vasodilatation in CS group (30.3 ± 3.7%; n = 8 in L‐ARG, 56.5 ± 8.8%; n = 9 in CS and 41.0 ± 5.5%; n = 18 in control). Conclusions: CS preserved endothelium‐dependent vasodilatation of RA greater than L‐ARG. These findings suggest that the use of statins may be an effective therapeutic strategy to preserve endothelial function in the RA grafts, and could have important implications in the clinical practice.
- Open Access
- 1 January 2004
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 25 (1) , 26-34
Analysis of thoracic aortic blood flow during off-pump coronary artery bypass surgery.
Objectives: The non-invasive monitoring of thoracic aortic blood flow (TABF) during off-pump coronary artery bypass (OPCAB) surgery is becoming more commonly used and proved to be invaluable in the early detection of haemodynamic compromise due to heart displacement. The aim of this study was to analyze the changes in the TABF during OPCAB using transoesophageal Doppler and compare them with the changes observed by other monitoring methods as cardiac output, invasive pulmonary and radial pressures and mixed venous oxygen saturation. Methods: The measurements obtained from classic haemodynamic monitoring methods including the radial artery line and the pulmonary artery catheter with continuous monitoring of the cardiac output and mixed venous blood oxygen saturation were compared to the measurements of TABF obtained from a transoesophageal Doppler probe in 15 consecutive patients who underwent OPCAB surgery. Results: The TABF decreased significantly during the construction of coronary anastomoses from 3.42±0.94 l/min (baseline) to 2.2±0.8 l/min during the first coronary anastomosis and then to 2.14±1.12 l/min during the second coronary anastomosis (F=4.29, P=0.008). TABF returned to the baseline values (2.85±1.19 l/min) at chest closure. The cardiac output measurement showed no significant decrease compared to baseline. Conclusions: Low TABF occurred without significant changes in the measurements obtained from classic haemodynamic monitoring methods during OPCAB surgery. This finding could be of vital importance in helping improve the monitoring and consequently the management of patients undergoing OPCAB surgery.
- 1 January 2004
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 25 (1) , 26-34
Open AccessAnalysis of thoracic aortic blood flow during off-pump coronary artery bypass surgery.
Objectives: The non-invasive monitoring of thoracic aortic blood flow (TABF) during off-pump coronary artery bypass (OPCAB) surgery is becoming more commonly used and proved to be invaluable in the early detection of haemodynamic compromise due to heart displacement. The aim of this study was to analyze the changes in the TABF during OPCAB using transoesophageal Doppler and compare them with the changes observed by other monitoring methods as cardiac output, invasive pulmonary and radial pressures and mixed venous oxygen saturation. Methods: The measurements obtained from classic haemodynamic monitoring methods including the radial artery line and the pulmonary artery catheter with continuous monitoring of the cardiac output and mixed venous blood oxygen saturation were compared to the measurements of TABF obtained from a transoesophageal Doppler probe in 15 consecutive patients who underwent OPCAB surgery. Results: The TABF decreased significantly during the construction of coronary anastomoses from 3.42±0.94 l/min (baseline) to 2.2±0.8 l/min during the first coronary anastomosis and then to 2.14±1.12 l/min during the second coronary anastomosis (F=4.29, P=0.008). TABF returned to the baseline values (2.85±1.19 l/min) at chest closure. The cardiac output measurement showed no significant decrease compared to baseline. Conclusions: Low TABF occurred without significant changes in the measurements obtained from classic haemodynamic monitoring methods during OPCAB surgery. This finding could be of vital importance in helping improve the monitoring and consequently the management of patients undergoing OPCAB surgery.