Hans Jürgen Hoffmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Hans Jürgen Hoffmann has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Lars Peter Nielsen
Department of Clinical Pharmacology, Aarhus University Hospital, Aarhus, Denmark
4 shared publications - Ronald Dahl
Department of Health, Clinical Institute, Aarhus University, Skejby, Denmark
4 shared publications Martin Iversen
3 shared publications- Torben Sigsgaard
Department of Public Health, Aarhus University, Aarhus, Denmark; Danish Big Data Centre for Environment and Health (BERTHA), Aarhus University, Aarhus, Denmark
3 shared publications Øyvind Omland
3 shared publicationsHisamitsu Takai
2 shared publications
Latest Publications
- Open Access
- 28 June 2008
- Published by Wiley in Scandinavian Journal of Immunology
- Vol. 59 (6) , 623-624
Decrease in Fine T-cell Subset ratio MT2/MT1 During Steroid Reduction of Asthmatic Patients
- 28 June 2008
- Published by Wiley in Scandinavian Journal of Immunology
- Vol. 59 (6) , 623-624
Open AccessDecrease in Fine T-cell Subset ratio MT2/MT1 During Steroid Reduction of Asthmatic Patients
- 22 February 2008
- Published by Wiley in The Clinical Respiratory Journal
- Vol. 2 (3) , 149-157
Asthmatics able to step down from inhaled corticosteroid treatment without loss of asthma control have low serum eotaxin/CCL11
The addition of a long-acting beta2 agonist (LABA) to inhaled corticosteroid (ICS) may control asthma better than ICS alone. Eosinophil markers may predict symptom severity in asthma. The effect of combination treatment on moderate to severe asthmatics not selected to respond rapidly to steroid deprivation was compared with monotherapy. The ability of serum markers to predict symptom severity was assessed. Asthmatics treated adequately with ICS (750-1000 mcg ICS daily) were randomised to receive ICS (fluticasone propionate) + LABA (salmeterol) (500 mcg/50 mcg bd) or ICS alone (500 mcg bd). If asthma was controlled at clinic visits every 6 weeks, ICS dose was tapered until asthma exacerbated (hospitalisation, ICS above study medication, peak flow variation, decline in forced expiratory volume in 1 s and/or use of rescue medication), or placebo was maintained for 6 weeks. Efficacy of the treatments was compared. Serum cytokines and chemokines were compared among the groups reporting severe, mild or no symptoms. There was no difference between the treatment arms in the clinical analysis. Nine patients could be maintained on placebo for 6 weeks, 36 developed mild symptoms and 16 developed severe symptoms. Patients on placebo for 6 weeks had significantly lower serum eotaxin at baseline than patients with symptoms. Patients with mild symptoms had intermediate serum eotaxin concentrations. Patients with asthma controlled on ICS respond heterogeneously to ICS tapering. Serum eotaxin/CCL11 may be useful in predicting the severity of symptoms patients develop during steroid tapering and should be evaluated in guiding asthma treatment.
- 22 February 2008
- Published by Wiley in The Clinical Respiratory Journal
- Vol. 2 (3) , 149-157
Asthmatics able to step down from inhaled corticosteroid treatment without loss of asthma control have low serum eotaxin/CCL11
The addition of a long-acting beta2 agonist (LABA) to inhaled corticosteroid (ICS) may control asthma better than ICS alone. Eosinophil markers may predict symptom severity in asthma. The effect of combination treatment on moderate to severe asthmatics not selected to respond rapidly to steroid deprivation was compared with monotherapy. The ability of serum markers to predict symptom severity was assessed. Asthmatics treated adequately with ICS (750-1000 mcg ICS daily) were randomised to receive ICS (fluticasone propionate) + LABA (salmeterol) (500 mcg/50 mcg bd) or ICS alone (500 mcg bd). If asthma was controlled at clinic visits every 6 weeks, ICS dose was tapered until asthma exacerbated (hospitalisation, ICS above study medication, peak flow variation, decline in forced expiratory volume in 1 s and/or use of rescue medication), or placebo was maintained for 6 weeks. Efficacy of the treatments was compared. Serum cytokines and chemokines were compared among the groups reporting severe, mild or no symptoms. There was no difference between the treatment arms in the clinical analysis. Nine patients could be maintained on placebo for 6 weeks, 36 developed mild symptoms and 16 developed severe symptoms. Patients on placebo for 6 weeks had significantly lower serum eotaxin at baseline than patients with symptoms. Patients with mild symptoms had intermediate serum eotaxin concentrations. Patients with asthma controlled on ICS respond heterogeneously to ICS tapering. Serum eotaxin/CCL11 may be useful in predicting the severity of symptoms patients develop during steroid tapering and should be evaluated in guiding asthma treatment.
- 1 October 2005
- Published by S. Karger AG in International Archives of Allergy and Immunology
- Vol. 138 (2) , 121-126
A Single Exposure to Organic Dust of Non-Naïve Non-Exposed Volunteers Induces Long-Lasting Symptoms of Endotoxin Tolerance
Background: Work with occupational levels of organic dust is associated with a chronic inflammatory response that must somehow be controlled. Endotoxin tolerance has previously been described in vitro and animal studies as a mechanism that modifies the threshold at which response occurs. Objective: We investigated the response of non-naïve, currently non-exposed persons to a single exposure of organic dust in a swine confinement building. Methods: We exposed 16 non-naïve persons in a swine confinement building with low-to-moderate representative levels of organic dust and characterized their acute immune response. Results: Under work-like 3-hour exposure conditions, non-naïve volunteers developed an inflammatory response documented by an increase in interleukin-6 (IL-6) in bronchoalveolar lavage (BAL) from 3.1 to 6.1 pg/ml and visual indices of bronchial inflammation. Similarly, serum IL-6 increased with a peak 3 h after exposure. Tumor necrosis factor (TNF)-α was not detected in BAL, and serum TNF-α was reduced from 3.7 pg/ml at baseline to less than 2 pg/ml within 3 h after exposure, and remained decreased until 2 weeks after exposure. This is a cardinal marker for immune suppression which was confirmed by other markers: reduction in HLA-DR expression on alveolar macrophages and CD14 expression on blood monocytes. Conclusion: We report findings that suggest that long-lasting endotoxin tolerance and immune suppression may be induced by a brief exposure to organic dust concentrations in the medium-low range of occupational levels.
- 1 October 2005
- Published by S. Karger AG in International Archives of Allergy and Immunology
- Vol. 138 (2) , 121-126
A Single Exposure to Organic Dust of Non-Naïve Non-Exposed Volunteers Induces Long-Lasting Symptoms of Endotoxin Tolerance
Background: Work with occupational levels of organic dust is associated with a chronic inflammatory response that must somehow be controlled. Endotoxin tolerance has previously been described in vitro and animal studies as a mechanism that modifies the threshold at which response occurs. Objective: We investigated the response of non-naïve, currently non-exposed persons to a single exposure of organic dust in a swine confinement building. Methods: We exposed 16 non-naïve persons in a swine confinement building with low-to-moderate representative levels of organic dust and characterized their acute immune response. Results: Under work-like 3-hour exposure conditions, non-naïve volunteers developed an inflammatory response documented by an increase in interleukin-6 (IL-6) in bronchoalveolar lavage (BAL) from 3.1 to 6.1 pg/ml and visual indices of bronchial inflammation. Similarly, serum IL-6 increased with a peak 3 h after exposure. Tumor necrosis factor (TNF)-α was not detected in BAL, and serum TNF-α was reduced from 3.7 pg/ml at baseline to less than 2 pg/ml within 3 h after exposure, and remained decreased until 2 weeks after exposure. This is a cardinal marker for immune suppression which was confirmed by other markers: reduction in HLA-DR expression on alveolar macrophages and CD14 expression on blood monocytes. Conclusion: We report findings that suggest that long-lasting endotoxin tolerance and immune suppression may be induced by a brief exposure to organic dust concentrations in the medium-low range of occupational levels.
- Open Access
- 4 July 2005
- Published by Springer Nature in Clinical and Molecular Allergy
- Vol. 3 (1) , 10-9
Lysis with Saponin improves detection of the response through CD203c and CD63 in the basophil activation test after crosslinking of the high affinity IgE receptor FcεRI
Background The basophil activation test (BAT), in which translocation of markers to the surface of blood basophils is measured in response to allergen by flow cytometry, is a rapid assay that is gaining popularity. Two markers are currently being evaluated for the BAT; CD63 and the lineage-specific CD203c. In a recent report, detection of CD203c after lysis with Saponin was shown to be superior to detection of CD63 after lysis with formic acid. We wanted to compare a) lysis with formic acid and lysis with Saponin, b) the response through CD203c and CD63, and c) the definition 10% activated cells above background with the probability binning metric T(χ) > 4, on sets of data generated with blood basophils stimulated with varying concentrations of anti-FcεRI antibody. Methods Blood from volunteers was incubated with serial logarithmic dilutions of anti-FcεRI and subsequently with antibodies to CD203c PE and CD63 FITC. Sets of samples set up in parallel were lysed with either Saponin based Whole Blood Lysing reagent or with formic acid based Immunoprep/Q-prep. Samples were acquired on a FACS Calibur, but were compensated and analysed offline. Responders were defined as persons who had 10% or more activated basophils above background, or a T(χ) > 4, for two consecutive dilutions of anti-FcεRI antibody. Results More basophils (median 1164 vs. median 397) and better discrimination of upregulated CD203c and CD63 amongst responders were obtained after lysis with Saponin than after lysis with formic acid. We suggest that CD203c may be a more sensitive marker for the BAT than CD63, as 6/11 responders were found with CD203c, compared with 3/11 with CD63. Most responders (7/11) were identified with probability binning. Conclusion A combination of lysis with Saponin and the markers CD203c and CD63 computed by probability binning may be the most sensitive method of detecting activation of basophils after stimulation through FcεRI.
- 4 July 2005
- Published by Springer Nature in Clinical and Molecular Allergy
- Vol. 3 (1) , 10-9
Open AccessLysis with Saponin improves detection of the response through CD203c and CD63 in the basophil activation test after crosslinking of the high affinity IgE receptor FcεRI
Background The basophil activation test (BAT), in which translocation of markers to the surface of blood basophils is measured in response to allergen by flow cytometry, is a rapid assay that is gaining popularity. Two markers are currently being evaluated for the BAT; CD63 and the lineage-specific CD203c. In a recent report, detection of CD203c after lysis with Saponin was shown to be superior to detection of CD63 after lysis with formic acid. We wanted to compare a) lysis with formic acid and lysis with Saponin, b) the response through CD203c and CD63, and c) the definition 10% activated cells above background with the probability binning metric T(χ) > 4, on sets of data generated with blood basophils stimulated with varying concentrations of anti-FcεRI antibody. Methods Blood from volunteers was incubated with serial logarithmic dilutions of anti-FcεRI and subsequently with antibodies to CD203c PE and CD63 FITC. Sets of samples set up in parallel were lysed with either Saponin based Whole Blood Lysing reagent or with formic acid based Immunoprep/Q-prep. Samples were acquired on a FACS Calibur, but were compensated and analysed offline. Responders were defined as persons who had 10% or more activated basophils above background, or a T(χ) > 4, for two consecutive dilutions of anti-FcεRI antibody. Results More basophils (median 1164 vs. median 397) and better discrimination of upregulated CD203c and CD63 amongst responders were obtained after lysis with Saponin than after lysis with formic acid. We suggest that CD203c may be a more sensitive marker for the BAT than CD63, as 6/11 responders were found with CD203c, compared with 3/11 with CD63. Most responders (7/11) were identified with probability binning. Conclusion A combination of lysis with Saponin and the markers CD203c and CD63 computed by probability binning may be the most sensitive method of detecting activation of basophils after stimulation through FcεRI.
- 16 September 2004
- Published by Wiley in American Journal of Industrial Medicine
- Vol. 46 (4) , 378-380
Exposure to work-related levels of swine dust up-regulates CD106 on human alveolar macrophages
- 16 September 2004
- Published by Wiley in American Journal of Industrial Medicine
- Vol. 46 (4) , 378-380
Exposure to work-related levels of swine dust up-regulates CD106 on human alveolar macrophages
- 20 September 2003
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 22 (44 suppl) , 1s-3s
Basic mechanisms of lung inflammation: executive summary of the first Lung Science Meeting of the European Respiratory Society at Taormina, Italy in 2003: 1
- 20 September 2003
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 22 (44 suppl) , 1s-3s
Basic mechanisms of lung inflammation: executive summary of the first Lung Science Meeting of the European Respiratory Society at Taormina, Italy in 2003: 1
- 15 July 2003
- Published by Wiley in Clinical & Experimental Allergy
- Vol. 33 (7) , 930-935
Lectins interact differentially with purified human eosinophils, cultured cord blood‐derived mast cells and the myeloid leukaemic cell line AML14.3D10: induction of interleukin‐4 secretion is conserved among granulocytes, but is not proportional to agglutination or lectin–glycoprotein interaction
Summary: Background Atopy is closely associated with the cellular T helper type‐2 (Th2) phenotype, that is dominated by the pleiotrophic cytokine IL‐4. The cellular source of IL‐4 has yet to be determined, although basophils have been proposed. Eosinophils and mast cells are likely contenders investigated here, and the eosinophil‐like leukaemia line AML14.3D10 is compared to eosinophils as an in vitro culturable model for eosinophils. Lectins can cross‐link‐specific surface glycoproteins and are found in the ingested (processed foods) and inhaled (airborne pollen grains) human environment. Therefore it is of interest to determine whether lectins can elicit the release of IL‐4 from Th2‐associated granulocytes other than basophils.Method This study investigated the ability of eosinophils, AML14.3D10 and mast cells to secrete preformed IL‐4 in response to stimulation with lectins, and explored molecular mechanisms underlying the interaction.Results Purified eosinophils and basophils, and cultured mast cells and AML14.3D10 cells were incubated with 1 µm lectin. Agglutination was scored by microscopy. IL‐4 secretion was measured by enayme‐linked immunosorbent assay. Biotinylated lectins were used to determine binding to cells by flow cytometry and in lectin blots of sodium dodecyl sulphate (SDS) gels.Discussion Purified human eosinophils, AML14.3D10 cells and cultured mast cells secrete IL‐4 with a pattern similar to that found in basophils when stimulated with a panel of reactive and unreactive lectins. The lectin SNA induces IL‐4 secretion from mast cells and basophils, but not from eosinophils or AML14.3D10. Eosinophils appear to secrete only pre‐formed IL‐4, whereas mast cells may synthesize IL‐4 on ligation with the lectin LCA. Lectins that agglutinate the granulocytes investigated do not necessarily induce secretion of IL‐4. Lectins that elicit secretion of IL‐4 bind more to eosinophils than unreactive lectins as determined by flow cytometry and lectin blotting of SDS gels.Conclusion As granulocytes with functions related to that of basophils, eosinophils, AML14.3D10 and cultured mast cells respond to stimulation with lectins similarly to basophils. This emphasizes the possibility that eosinophils and mast cells may be linked in their cellular heritage as the cellular partners, and lectins as ligands, may contribute to the maintenance of a Th2‐favoured microenvironment that is thought to underlie the allergic march.
- 15 July 2003
- Published by Wiley in Clinical & Experimental Allergy
- Vol. 33 (7) , 930-935
Lectins interact differentially with purified human eosinophils, cultured cord blood‐derived mast cells and the myeloid leukaemic cell line AML14.3D10: induction of interleukin‐4 secretion is conserved among granulocytes, but is not proportional to agglutination or lectin–glycoprotein interaction
Summary: Background Atopy is closely associated with the cellular T helper type‐2 (Th2) phenotype, that is dominated by the pleiotrophic cytokine IL‐4. The cellular source of IL‐4 has yet to be determined, although basophils have been proposed. Eosinophils and mast cells are likely contenders investigated here, and the eosinophil‐like leukaemia line AML14.3D10 is compared to eosinophils as an in vitro culturable model for eosinophils. Lectins can cross‐link‐specific surface glycoproteins and are found in the ingested (processed foods) and inhaled (airborne pollen grains) human environment. Therefore it is of interest to determine whether lectins can elicit the release of IL‐4 from Th2‐associated granulocytes other than basophils.Method This study investigated the ability of eosinophils, AML14.3D10 and mast cells to secrete preformed IL‐4 in response to stimulation with lectins, and explored molecular mechanisms underlying the interaction.Results Purified eosinophils and basophils, and cultured mast cells and AML14.3D10 cells were incubated with 1 µm lectin. Agglutination was scored by microscopy. IL‐4 secretion was measured by enayme‐linked immunosorbent assay. Biotinylated lectins were used to determine binding to cells by flow cytometry and in lectin blots of sodium dodecyl sulphate (SDS) gels.Discussion Purified human eosinophils, AML14.3D10 cells and cultured mast cells secrete IL‐4 with a pattern similar to that found in basophils when stimulated with a panel of reactive and unreactive lectins. The lectin SNA induces IL‐4 secretion from mast cells and basophils, but not from eosinophils or AML14.3D10. Eosinophils appear to secrete only pre‐formed IL‐4, whereas mast cells may synthesize IL‐4 on ligation with the lectin LCA. Lectins that agglutinate the granulocytes investigated do not necessarily induce secretion of IL‐4. Lectins that elicit secretion of IL‐4 bind more to eosinophils than unreactive lectins as determined by flow cytometry and lectin blotting of SDS gels.Conclusion As granulocytes with functions related to that of basophils, eosinophils, AML14.3D10 and cultured mast cells respond to stimulation with lectins similarly to basophils. This emphasizes the possibility that eosinophils and mast cells may be linked in their cellular heritage as the cellular partners, and lectins as ligands, may contribute to the maintenance of a Th2‐favoured microenvironment that is thought to underlie the allergic march.
- 1 January 2003
- Vol. 10 (1) , 53-60
Plasma C3d levels of young farmers correlate with respirable dust exposure levels during normal work in swine confinement buildings.
Work in swine confinement buildings leads to an inflammatory response and may be associated with increased levels of acute phase proteins. We compared the inflammatory response of a control group of young former farm workers with age-matched former farm workers who had previously developed the lower airway symptoms of wheeze, cough, tightness of the chest during work in swine confinement buildings, and because of these symptoms had stopped work. Both groups were subjected to an experimental exposure in a swine confinement building for 3 hours. Complement activation and acute phase proteins were measured in blood samples and broncho-alveolar lavage. Plasma C3d levels correlated with respirable dust, significantly so for individual cases and for the whole cohort. Plasma C3, fibrinogen and alpha (1) -acid glycoprotein peaked 1 and 6 h after exposure start, mannan-binding lectin, C-reactive protein and alpha(1)-antitrypsin peaked after 2 h. Surfactant protein D (SP-D) and alpha (2) -macroglobulin were downregulated. In lavage, only SP-D, alpha (2)-macroglobulin and fibronectin were detected. FEV(1), FVC, TLC and FEV(25-75) did not vary during exposure. There was complement activation in response to respiratory dust, more so amongst cases than in the control group. Acute exposure, with work related levels of organic dust containing endotoxin, leads to a weak systemic inflammatory response.
- 1 January 2003
- Vol. 10 (1) , 53-60
Plasma C3d levels of young farmers correlate with respirable dust exposure levels during normal work in swine confinement buildings.
Work in swine confinement buildings leads to an inflammatory response and may be associated with increased levels of acute phase proteins. We compared the inflammatory response of a control group of young former farm workers with age-matched former farm workers who had previously developed the lower airway symptoms of wheeze, cough, tightness of the chest during work in swine confinement buildings, and because of these symptoms had stopped work. Both groups were subjected to an experimental exposure in a swine confinement building for 3 hours. Complement activation and acute phase proteins were measured in blood samples and broncho-alveolar lavage. Plasma C3d levels correlated with respirable dust, significantly so for individual cases and for the whole cohort. Plasma C3, fibrinogen and alpha (1) -acid glycoprotein peaked 1 and 6 h after exposure start, mannan-binding lectin, C-reactive protein and alpha(1)-antitrypsin peaked after 2 h. Surfactant protein D (SP-D) and alpha (2) -macroglobulin were downregulated. In lavage, only SP-D, alpha (2)-macroglobulin and fibronectin were detected. FEV(1), FVC, TLC and FEV(25-75) did not vary during exposure. There was complement activation in response to respiratory dust, more so amongst cases than in the control group. Acute exposure, with work related levels of organic dust containing endotoxin, leads to a weak systemic inflammatory response.
- 1 July 2001
- Published by Elsevier in Biochemical and Biophysical Research Communications
- Vol. 285 (2) , 320-327
Identification of Three New Splice Variants of the SNARE Protein SNAP-23
- 1 July 2001
- Published by Elsevier in Biochemical and Biophysical Research Communications
- Vol. 285 (2) , 320-327
Identification of Three New Splice Variants of the SNARE Protein SNAP-23
- 1 January 1999
- Published by Hogrefe Publishing Group in Allergy & Clinical Immunology International - Journal of the World Allergy Organization
- Vol. 11 (1) , 0004-0010
Intranasal Corticosteroids, Inflammation, and Symptoms in Allergic Rhinitis
- 1 January 1999
- Published by Hogrefe Publishing Group in Allergy & Clinical Immunology International - Journal of the World Allergy Organization
- Vol. 11 (1) , 0004-0010
Intranasal Corticosteroids, Inflammation, and Symptoms in Allergic Rhinitis