EMElysia Moschos

Elysia Moschos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Elysia Moschos has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Biometric Sonographic Findings of Abnormally Adherent Trophoblastic Implantations on Cesarean Delivery Scars

    by Elysia Moschos, C. Edward Wells, Diane M. Twickler

    Objectives: The purpose of this study was to review first‐trimester transvaginal sonograms of patients with cervicoisthmic implantations and prior cesarean deliveries to determine whether sonographic biometric measurements can distinguish between abnormally adherent trophoblastic implantations and normally implanted pregnancies.Methods: Our database was reviewed from October 2006 through December 2011 for patients with first‐trimester sonographic diagnoses of cervicoisthmic implantations and previous cesarean deliveries. Biometric measurements of the smallest distance from the anterior trophoblastic border to the uterine serosa were performed on transvaginal sagittal images of the uterus. Outcomes were classified into 5 categories: cesarean scar pregnancy, placental invasion (accreta/increta/percreta), previa without invasion, spontaneous abortion, and delivered intrauterine pregnancy. Statistical methods included analysis of variance with the Tukey range test and Student t test.Results: Of 77 studies, outcome data were available for 56 patients. The mean gestational age was 8.8 weeks (minimum, 2.0 weeks; maximum, 14.9 weeks). The anterior trophoblastic border distances from the uterine serosa were significantly smaller in cesarean scar pregnancies (mean, 1.6 mm; SD, 0.6 mm) and placental invasion pregnancies (mean, 2.2 mm; SD, 1.0 mm) than the normally implanted groups (mean, 7.9 mm, SD, 3.3 mm; P < .0001).Conclusions: Smaller trophoblastic border distances to the anterior uterine serosa are seen in abnormally adherent trophoblastic implantations, and these distances distinguish them from other pregnancy outcomes.


  • Does the Type of Intrauterine Device Affect Conspicuity on 2D and 3D Ultrasound?

    by Elysia Moschos, Diane M. Twickler

    OBJECTIVE. The objective of our study was to assess the conspicuity and position evaluation of intrauterine devices (IUDs) on 2D ultrasound and 3D ultrasound in nongravid patients. MATERIALS AND METHODS. Review of the ultrasound database for the period from July 2008 through June 2009 was performed for identification of patients with IUDs, of the type and position of the IUD, and of the patient's presenting symptoms. The conspicuity of the IUD on 2D sagittal and transverse planes and 3D coronal views was scored according to a 7-point scale. Data analysis was performed using the Student t test and the Pearson chi-square test. RESULTS. Of the 269 patients with IUDs who had undergone ultrasound during the study period, 180 patients had a copper IUD; 59, a levonorgestrel-releasing device; and three, a Lippes loop. Twenty-seven IUDs were excluded because they were not seen on ultrasound (n = 15) or the type of IUD was not identifiable (n = 12). Of the 239 IUDs identified, the conspicuity score for copper IUDs ...


  • Saline-Infusion Sonography Endometrial Sampling Compared With Endometrial Biopsy in Diagnosing Endometrial Pathology

    by Elysia Moschos, Rahella Ashfaq, Donald D. McIntire, Bienviendo Liriano, Diane M. Twickler

    To evaluate prospectively whether saline-infusion sonography endometrial sampling will improve diagnosis of benign and malignant endometrial disease compared with blind endometrial biopsy in perimenopausal and postmenopausal women with abnormal uterine bleeding. After initial assessments and endometrial biopsies, women aged 40 or older with abnormal uterine bleeding were referred for transvaginal ultrasonography. Patients with abnormal endometrial evaluations were offered sonohysterography and invited to enter the saline-infusion sonography endometrial sampling study. Saline-infusion sonography endometrial sampling was performed at the end of sonohysterography using an endometrial sampling curette at the sight of the endometrial abnormality or at a representative site in the endometrial cavity if the cavity was normal. Histopathologic diagnoses of blind endometrial biopsy and saline-infusion sonography endometrial sampling were compared with final outcomes. Kappa values for the two sampling techniques were calculated for diagnostic accuracy. A total of 88 saline-infusion sonography endometrial samples were obtained; final outcomes were attained in 80 cases. When comparing saline-infusion sonography endometrial sampling with final outcomes, saline-infusion sonography endometrial sampling provided a diagnosis 89% of the time (95% confidence interval [CI] 82–95%) compared with endometrial biopsy at 52% (95% CI 42–62%). Forty-five patients with endometrial biopsies had final outcomes. When comparing endometrial biopsy with final outcomes, endometrial biopsy underestimated the incidence of pathology, especially when focal lesions and malignancy were present. This difference was statistically significant (P<.005). Saline-infusion sonography endometrial sampling is superior to endometrial biopsy in diagnosing endometrial pathology in perimenopausal and postmenopausal women with abnormal uterine bleeding. II


  • Open Access

    Endometrial thickness predicts intrauterine pregnancy in patients with pregnancy of unknown location

    by E. Moschos, D. M. Twickler

    Objective: To determine whether endometrial thickness and other parameters are useful predictors of normal intrauterine pregnancy (IUP) in the setting of vaginal bleeding and sonographic diagnosis of pregnancy of unknown location (PUL).Methods: We reviewed the clinical and sonographic records of all 591 patients with vaginal bleeding and a sonographic diagnosis of PUL between 1 July 2005 and 30 June 2006. Data on maternal age, gravidity, parity, estimated gestational age by last menstrual period (EGA by LMP), endometrial thickness and serum β‐human chorionic gonadotropin (β‐hCG) were collected. Complete data were available for 517 patients, 40 (7.7%) of whom ultimately had normal IUPs. A logistic regression model was constructed using a stepwise procedure to identify variables significantly associated with the outcome of normal IUP. The validity of the model was assessed by receiver–operating characteristics (ROC) curve and Hosmer–Lemeshow Chi‐square analysis.Results: Four variables (maternal age, EGA by LMP, endometrial thickness and serum β‐hCG) were significant in the prediction of normal IUP (area under the ROC curve = 0.86). As maternal age, EGA by LMP and β‐hCG increased, the likelihood of a normal IUP decreased, while as the endometrial thickness increased, the likelihood of a normal IUP increased. For each millimeter increase in endometrial thickness, the odds increased by 27% that the patient would have a normal IUP. No normal IUP had an endometrial thickness < 8 mm.Conclusion: Increased endometrial thickness predicts normal IUP in patients who present with vaginal bleeding and PUL. Copyright © 2008 ISUOG. Published by John Wiley & Sons, Ltd.


  • First‐trimester diagnosis of cesarean scar ectopic pregnancy

    by Elysia Moschos, Sreedevi Sreenarasimhaiah, Diane M. Twickler

    Once considered extremely rare, implantation of a pregnancy within the scar of a previous cesarean section is becoming more common. In fact, its incidence is now higher than that of cervical ectopic pregnancies. We identified 5 cases of ectopic pregnancy implanted in a prior cesarean section scar at our institution since 2004. We outline the criteria for the first‐trimester sonographic diagnosis of cesarean scar ectopic pregnancy, including a new sign of lower uterine segment ballooning, which has previously not been reported. Clinicians must have a heightened awareness of this serious and potentially fatal pregnancy complication. © 2008 Wiley Periodicals, Inc. J Clin Ultrasound, 2008.