Thomas Neumann
Research Subjects
Thomas Neumann has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Michael Meyer
4 shared publicationsAlan C. Nelson
VisionGate, Inc, Gig Harbor, Washington
2 shared publicationsChris Presley
2 shared publicationsDavid Wilbur
2 shared publicationsJon Hayenga
2 shared publicationsRahul Katdare
2 shared publications
Latest Publications
- 1 September 2014
- Published by Elsevier in Journal of the American Society of Cytopathology
- Vol. 3 (5) , S3-S4
Lung Cancer Detection with LuCED, a Novel Test Based on 3D Cytometry of Sputum Cells
- 1 September 2014
- Published by Elsevier in Journal of the American Society of Cytopathology
- Vol. 3 (5) , S3-S4
Lung Cancer Detection with LuCED, a Novel Test Based on 3D Cytometry of Sputum Cells
- 20 May 2014
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 32 (15_suppl) , 7547
Early detection of lung cancer based on three-dimensional, morphometric analysis of cells from sputum.
7547 Background: Utilizing a new 3D morphometric analytical device called Cell-CT, we analyzed cells from sputum to detect lung cancer in patients with malignant nodules found using low-dose x-ray CT (LDCT). This study assesses the sensitivity and specificity of the Cell-CT analysis for lung cancer in this context. Methods: Case sensitivity was assessed by analyzing sputum from patients with biopsy-confirmed non-small cell lung cancer (NSCLC) and small cell lung cancer (SCLC). Spontaneously produced sputum was collected over three consecutive days and fixed. Specimens were then enriched for epithelial cells and stained with hematoxylin. These cells were imaged using VisionGate’s Cell-CT system that computes 3D cell images with isometric, sub-micron resolution. Cell images were then automatically analyzed by a computer classifier to identify abnormal cells. Of the 800 measured features, the strongest 25 were used in the classifier. The diagnosis for these cells was computer-generated and manually confirmed by a cytotechnologist. Specificity was assessed by analyzing cells in sputum from normal patients who were at high risk for lung cancer. Bronchial epithelial cells were counted to determine specimen adequacy. Results: 26 NSCLC and 4 SCLC, or 30 total cases were processed that met the criteria for adequacy. Moderate/severe dysplasia or cancer cells were found in 28 of the 30 cases. In 26 of the 28 cases, cancer cells were present. Cancer and dysplastic cells were detected by the Cell-CT for an overall case sensitivity of 93.3%. 15 of 30 cases were either stage I or stage II lung cancer, and 14 of these 15 cases (or 93.3%) were detected. 5,146 sputum cells from 17 normal patients at high risk for lung cancer were processed with zero false positive indications. The lower 95% confidence bound for specificity is 99.8%. Conclusions: With a sensitivity of 93.3% to early stage lung cancers and a lower limit to specificity of 99.8% based on a non-invasive sputum analysis, the Cell-CT platform could be deployed to help eliminate false positives from LDCT. Further studies will establish the Cell-CT performance across a broader range of clinical conditions to evaluate the potential use of the Cell-CT as a primary screener for lung cancer.
- 20 May 2014
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 32 (15_suppl) , 7547
Early detection of lung cancer based on three-dimensional, morphometric analysis of cells from sputum.
7547 Background: Utilizing a new 3D morphometric analytical device called Cell-CT, we analyzed cells from sputum to detect lung cancer in patients with malignant nodules found using low-dose x-ray CT (LDCT). This study assesses the sensitivity and specificity of the Cell-CT analysis for lung cancer in this context. Methods: Case sensitivity was assessed by analyzing sputum from patients with biopsy-confirmed non-small cell lung cancer (NSCLC) and small cell lung cancer (SCLC). Spontaneously produced sputum was collected over three consecutive days and fixed. Specimens were then enriched for epithelial cells and stained with hematoxylin. These cells were imaged using VisionGate’s Cell-CT system that computes 3D cell images with isometric, sub-micron resolution. Cell images were then automatically analyzed by a computer classifier to identify abnormal cells. Of the 800 measured features, the strongest 25 were used in the classifier. The diagnosis for these cells was computer-generated and manually confirmed by a cytotechnologist. Specificity was assessed by analyzing cells in sputum from normal patients who were at high risk for lung cancer. Bronchial epithelial cells were counted to determine specimen adequacy. Results: 26 NSCLC and 4 SCLC, or 30 total cases were processed that met the criteria for adequacy. Moderate/severe dysplasia or cancer cells were found in 28 of the 30 cases. In 26 of the 28 cases, cancer cells were present. Cancer and dysplastic cells were detected by the Cell-CT for an overall case sensitivity of 93.3%. 15 of 30 cases were either stage I or stage II lung cancer, and 14 of these 15 cases (or 93.3%) were detected. 5,146 sputum cells from 17 normal patients at high risk for lung cancer were processed with zero false positive indications. The lower 95% confidence bound for specificity is 99.8%. Conclusions: With a sensitivity of 93.3% to early stage lung cancers and a lower limit to specificity of 99.8% based on a non-invasive sputum analysis, the Cell-CT platform could be deployed to help eliminate false positives from LDCT. Further studies will establish the Cell-CT performance across a broader range of clinical conditions to evaluate the potential use of the Cell-CT as a primary screener for lung cancer.
- 22 October 2009
- Published by Wiley in Cancer Cytopathology
- Vol. 117 (6) , 473-481
Premalignant and malignant cells in sputum from lung cancer patients
BACKGROUND: The objective of this study was to assess the frequency of premalignant and malignant cells in sputum from patients with lung cancer and to measure the dependence of these cells on cancer stage, histologic type, tumor size, and tumor location.METHODS: This analysis included 444 patients with lung cancer. First, all patients were asked to produce sputum spontaneously; then, they underwent sputum induction. Slide preparations of the sputa were screened for the presence of abnormal cells.RESULTS: Of all patients with lung cancer who had produced adequate specimens, 74.6% had sputum that was positive for premalignant or worse cells, whereas 48.7% had sputum that was positive for malignant cells alone. Surprisingly, the presence of premalignant or worse cells in sputum depended only moderately on disease stage (82.9% of stage IV cancers vs 65.9% of stage I cancers), tumor size (78.6% of tumors >2 cm vs 64.7% of tumors ≤2 cm), and location (83.3% of central lesions vs 68% of peripheral lesions) and was found to be independent of histologic tumor type (78.4% of squamous cell carcinomas vs 71.5% of adenocarcinomas, 74.5% of small cell carcinomas, and 75% of large cell carcinomas).CONCLUSIONS: The findings of the current study suggested the important potential of sputum cytology for lung cancer detection and risk assessment across all stages, histologic types, tumor sizes, and locations. However, the high sensitivities in this study were achieved with a level of scrutiny not feasible in the laboratory routine. The diagnostic potential of sputum cytology may be exploited better through the standardization and automation of sputum preparation and analysis. Cancer (Cancer Cytopathol) 2009. © 2009 American Cancer Society.
- 22 October 2009
- Published by Wiley in Cancer Cytopathology
- Vol. 117 (6) , 473-481
Premalignant and malignant cells in sputum from lung cancer patients
BACKGROUND: The objective of this study was to assess the frequency of premalignant and malignant cells in sputum from patients with lung cancer and to measure the dependence of these cells on cancer stage, histologic type, tumor size, and tumor location.METHODS: This analysis included 444 patients with lung cancer. First, all patients were asked to produce sputum spontaneously; then, they underwent sputum induction. Slide preparations of the sputa were screened for the presence of abnormal cells.RESULTS: Of all patients with lung cancer who had produced adequate specimens, 74.6% had sputum that was positive for premalignant or worse cells, whereas 48.7% had sputum that was positive for malignant cells alone. Surprisingly, the presence of premalignant or worse cells in sputum depended only moderately on disease stage (82.9% of stage IV cancers vs 65.9% of stage I cancers), tumor size (78.6% of tumors >2 cm vs 64.7% of tumors ≤2 cm), and location (83.3% of central lesions vs 68% of peripheral lesions) and was found to be independent of histologic tumor type (78.4% of squamous cell carcinomas vs 71.5% of adenocarcinomas, 74.5% of small cell carcinomas, and 75% of large cell carcinomas).CONCLUSIONS: The findings of the current study suggested the important potential of sputum cytology for lung cancer detection and risk assessment across all stages, histologic types, tumor sizes, and locations. However, the high sensitivities in this study were achieved with a level of scrutiny not feasible in the laboratory routine. The diagnostic potential of sputum cytology may be exploited better through the standardization and automation of sputum preparation and analysis. Cancer (Cancer Cytopathol) 2009. © 2009 American Cancer Society.
- 1 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 379-381
Simultaneous 3D imaging of morphology and nanoparticle distribution in single cells with the Cell-CT™ technology
The Cell-CT™ is an optical projection tomography microscope (OPTM) developed for high resolution 3D imaging of single cells based on absorption stains and brightfield microscopy. In this study we demonstrate the use of the Cell-CT™ in multi-color mode for simultaneous imaging of cellular 3D morphology and the 3D distribution of nanoparticle clusters in the cytoplasm. The ability to image cellular processes in relation to cellular compartments with a non-fluorescence 3D technology opens new perspectives for molecular research.
- 1 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 379-381
Simultaneous 3D imaging of morphology and nanoparticle distribution in single cells with the Cell-CT™ technology
The Cell-CT™ is an optical projection tomography microscope (OPTM) developed for high resolution 3D imaging of single cells based on absorption stains and brightfield microscopy. In this study we demonstrate the use of the Cell-CT™ in multi-color mode for simultaneous imaging of cellular 3D morphology and the 3D distribution of nanoparticle clusters in the cytoplasm. The ability to image cellular processes in relation to cellular compartments with a non-fluorescence 3D technology opens new perspectives for molecular research.